972 resultados para colorimetric


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A photonic system has been developed that enables sensitive quantitative determination of reactive oxygen species (ROS) - mainly hydrogen peroxide (H2O2) - in aerosol samples such as airborne nanoparticles and exhaled air from patients. The detection principle relies on the amplification of the absorbance under multiple scattering conditions due to optical path lengthening [1] and [2]. In this study, the presence of cellulose membrane that acts as random medium into the glass optical cell considerably improved the sensitivity of the detection based on colorimetric FOX assay (FeII/orange xylenol). Despite the loss of assay volume (cellulose occupies 75% of cell volume) the limit of detection is enhanced by one order of magnitude reaching the value of 9 nM (H2O2 equivalents). Spectral analysis is performed automatically with a periodicity of 5 to 15 s, giving rise to real-time ROS measurements. Moreover, the elution of air sample into the collection chamber via a micro-diffuser (impinger) enables quantitative determination of ROS contained in or generated from airborne samples. As proof-of-concept the photonic ROS detection system was used in the determination of both ROS generated from traffic pollution and ROS contained in the exhaled breath as lung inflammation biomarkers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The determination of zirconium-hafnium mixtures is one of the most critical problem of the analytical chemistry, on account of the close similarity of their chemical properties. The spectrophotometric determination proposed by Yagodin et al. show not many practical applications due to the significant spectral interference on the 200-220 nm region. In this work we propound the use of a multivariate calibration method called partial least squares ( PLS ) for colorimetric determination of these mixtures. By using PLS and 16 calibration mixtures we obtained a model which permits determination of zirconium and hafnium with accuracy of about 1-2% and 10-20%, respectively. Using conventional univariate calibration the inaccuracy of the determination is about 10-25% for zirconium and above 57% for hafnium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tannins are compounds of great interest in chemistry and ecology. They have various effects on food digestibility and the performance of animals. In this work, the chemistry, the biological activity and the ecology of tannins are examined. A brief discussion of several analytical methods for the determination of tannins is presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hydrogen peroxide bleaching of sodium alginate from seaweeds oh the Sargassum genus was studied. The influence of H2O2 concentration (percentage of H2O2 on a dry weight alginate basis, w/w) and NaOH/H2O2 ratio (% NaOH/% H2O2, both referred to a dry weight alginate basis, w/w) on the molecular weight, color removal and content of Fe3+ ions of bleached alginate samples was investigated by UV and IR spectroscopies, colorimetric determination of Fe3+ ions and vapor pressure osmometry. Higher yield, purity and molecular weight of alginate were obtained using 3% (or less) of hydrogen peroxide and a NaOH/H2O2 ratio of 1.2 for bleaching.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work describes the establishment of the concept of pH and the evolution of its measurement. The origin of the pH definition can be found in the development of the chemistry of aqueous solutions during the XIXth century. The electrolytic dissociation theory by Svante Arrhenius played a central role. After the proposal of the pH scale by Sörensen, many years were necessary for the acceptance of this new parameter among chemists in general. Its importance was first recognized in biochemistry and related areas. Twenty years after, its importance had been recognized in many industrial and laboratorial practices. The previous methods were based on colorimetric and electrometric methods, but both suffered from many problems. Acceptance of pH in Chemistry was only possible after the development of experimental trustable measurements. The invention of the pH meter was the primordial step.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In terms of soil fertility, zinc is a micronutrient that is very important in the culture of soy, maize, rice and coffee, because it is a structural and functional component of a great number of enzymes. Therefore, diverse methods have been used to determine zinc in soil. In this work we use colorimetry as a methods of zinc determination in soil using two methodologies of sample digesting, H2SO4/H2O2 and HNO3/H2O2. In order to compare the results, atomic absorption spectrometry (AAS) was used. Results show that colorimetric methods can be used due to good sensitivity and reproducibility, since the zinc calibration curve showed good linearity. Comparing colorimetric methods with AAS we observed that the results were equivalent, as proven by the statistical values of the F and t of Student tests. Furthermore, both methods of soil digesting can be used, leading to a flexible methodology of low-cost for routine zinc analyses in soil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of an array of chemically-responsive dyes on a porous membrane and in its use as a general sensor for odors and volatile organic compounds (VOCs) is reviewed. These colorimetric sensor arrays (CSA) act as an "optoelectronic nose" by using an array of multiple dyes whose color changes are based on the full range of intermolecular interactions. The CSA is digitally imaged before and after exposure and the resulting difference map provides a digital fingerprint for any VOC or mixture of odorants. The result is an enormous increase in discriminatory power among odorants compared to prior electronic nose technologies. For the detection of biologically important analytes, including amines, carboxylic acids, and thiols, high sensitivities (ppbv) have been demonstrated. The array is essentially non-responsive to changes in humidity due to the hydrophobicity of the dyes and membrane.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pulp hemicelluloses can be extracted with NaOH and quantified by colorimetric and gravimetric techniques. However the most usual methods to measure eucalyptus pulp hemicelluloses have been through the pentosan method or through xylan analyses by GC or HPLC techniques. In this study a comparison was made between the more traditional methods and indirect method of NaOH 5% extraction followed by colorimetric analyses. It was observed that the content of NaOH 5% extract correlates very well with pulp xylan content and reasonably well with the pentosan content. It is concluded that the 5% NaOH solubility method can be used in replacement of the other two, since it is faster, simpler and less costly to carry out than the others.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of the present study was the evaluation of the presence of organic and inorganic contaminants in samples of aged cachaça from the South of the state of Minas Gerais. Furfural, methanol and copper were determined by colorimetric reactions, while the analyses of ethyl carbamate and acrolein were performed by GC/MS and HPLC, respectively. High levels of furfural and copper were obtained. All samples showed concentrations below the established by legislation for the ethyl carbamate, and for acrolein, only one sample showed higher levels. Methanol was not detected in the samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A method based on enzymatic activities was developed using three enzymes (glycerokinase, glycerol-3-phosphate oxidase and peroxidase) and colorimetric detection for the determination of glycerol in biodiesel. The enzymatic conversion of glycerol produces H2O2 that is eliminated by the action of peroxidase, an oxygen acceptor and 4- aminoantipirine, producing water and a colored compound, which was analyzed. This method showed good linear correlation coefficient (r = 0.9937) in the concentration range of 4.95 x 10-5 to 3.96 x 10-4% (w/w) and had experimental limits of detection and quantitation of 7.10 x 10-6 and 2.10 x 10-5% (w/w), respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Marijuana (Cannabis sativa L.) is the most cultivated, trafficked and consumed illicit drug worldwide. Estimates indicate 10% of individuals experiencing marijuana become daily users, and 20-30% use it weekly. Around 489 natural compounds have been identified in this plant, of which 70 are cannabinoids, responsible for psychic effects. The most relevant cannabinoid is Δ9-THC, recognized as the main chemical substance with psychoactive effects. The aims of this work was to investigate whether other drugs interfere with the colorimetric tests Fast Blue B and Duquenois-Levine, widely used for marijuana screening in forensic chemistry laboratories.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The efficiency of the chemiluminescence luminol method and colorimetric DPPH and ABTS methods in evaluating the antiradical capacity of pure compounds and plant extracts with antioxidant potential is compared. In case of pure compounds, the values of parameter 'n' (number of radicals quenched per molecule of antiradical) for ascorbic acid, p-hydroquinone, catechol, quercetin, and rutin are similar when measured by colorimetric assays; however, considerably lower values of n are obtained with the luminol assay. The antiradical activity of extracts from male and female individuals of Baccharis burchelli and Baccharis crispa were determined by the luminol assay and expressed using the new Trolox® percentage (%Trolox®) parameter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Capsaicinoids (CAPS) are substances responsible for pungency in Capsicum. It is important to quantify these types of compounds owing to their broad application in food, pharmaceuticals, cosmetics and chemical weapons. In this work, we developed an indirect spectrophotometric method based on the colorimetric reaction between CAPS, Co(II) 3.10×10-5 mol L-1 and 4-(2-pyridylazo) resorcinol (PAR) 6.23×10-5 and, in cachaça:water 92:8v/v solutions, for quantification of total CAPS in Capsicum peppers. The product of the reaction is CoPAR2CAPS2 and its absorption in aquo-ethanolic solution at 510 nm is proportional to the total CAPS concentration from 0.60 to 17.94 mg L-1. The values of limit of detection and limit of quantification were 0.0004 and 0.001 mg of CAPS/g of pepper, respectively, with 4% relative standard deviation. The developed method yielded similar results to those obtained from high performance liquid chromatography, with 95% of confidence.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This review deals with the basis and novel trends in electrochromism, describing the basic aspects and methodologies employed for the construction and analyses of different modified electrodes. The work presents the classic materials used for the construction of electrochromic electrodes, such as WO3 and a view on the basic concepts of chromaticity as a useful approach for analyzing colorimetric results. The report also addresses how the incorporation of nanomaterials and the consequent novel modification of electrodes have furthered this area of science, producing electrochromic electrodes with high performance, high efficiency and low response times.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cocaine is usually seized mixed with a wide variety of adulterants such as benzocaine, lidocaine, caffeine, and procaine. The forensic identification of cocaine in these street drug mixtures is normally performed using colorimetric testing kits, but these tests may suffer from interferences, producing false-positive results. Here, we describe the use of analytical techniques including attenuated total reflection Fourier transform infrared (ATR-FTIR) and ultraviolet-visible (UV-VIS) spectroscopies to distinguish between cocaine and other adulterants (lidocaine, promethazine, powdered milk and yeast) that yield positive results on the Scott test using the thiocyanate cobalt reagent. A further 13 substances were also analyzed using the Scott test.