948 resultados para coefficient of variance


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives This study established the value of the 6-sulfatoxymelatonin (aMT6s) urine concentration as a predictor of the therapeutic response to noradrenaline reuptake inhibitors in depressive patients. Methods Twenty-two women aged 18-60 years were selected. Depressive symptoms were assessed by using the Hamilton Depression Scale. Urine samples were collected at 0600-1200 h, 1200-1800 h, 1800-2400 h, and 2400-0600 h intervals, 1 day before and 1 day after starting on the nortriptyline treatment. Urine aMT6s concentration was analyzed by a one-way analysis of variance/Bonferroni test. Spearman`s rank correlation coefficient was used to analyze the correlation between depressive symptoms after 2 weeks of antidepressant treatment and the increase in aMT6s urine concentration. Results Higher and lower size effect groups were compared by independent Student`s t-tests. At baseline, the 2400- to 0600-h interval differed from all other intervals presenting a significantly higher aMT6s urine concentration. A significant difference in aMT6s urine concentrations was found 1 day after treatment in all four intervals. Higher size effect group had lower levels of depressive symptoms 2 weeks after the treatment. A positive correlation between depressive symptoms and the delta of aMT6s in the 2400-0600h interval was observed. Conclusion Our results reinforce the hypothesis that aMT6s excretion is a predictor of clinical outcome in depression, especially in regard to noradrenaline reuptake inhibitors. Copyright (C) 2011 John Wiley & Sons, Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Canalization is defined as the stability of a genotype against minor variations in both environment and genetics. Genetic variation in degree of canalization causes heterogeneity of within-family variance. The aims of this study are twofold: (1) quantify genetic heterogeneity of (within-family) residual variance in Atlantic salmon and (2) test whether the observed heterogeneity of (within-family) residual variance can be explained by simple scaling effects. RESULTS: Analysis of body weight in Atlantic salmon using a double hierarchical generalized linear model (DHGLM) revealed substantial heterogeneity of within-family variance. The 95% prediction interval for within-family variance ranged from ~0.4 to 1.2 kg2, implying that the within-family variance of the most extreme high families is expected to be approximately three times larger than the extreme low families. For cross-sectional data, DHGLM with an animal mean sub-model resulted in severe bias, while a corresponding sire-dam model was appropriate. Heterogeneity of variance was not sensitive to Box-Cox transformations of phenotypes, which implies that heterogeneity of variance exists beyond what would be expected from simple scaling effects. CONCLUSIONS: Substantial heterogeneity of within-family variance was found for body weight in Atlantic salmon. A tendency towards higher variance with higher means (scaling effects) was observed, but heterogeneity of within-family variance existed beyond what could be explained by simple scaling effects. For cross-sectional data, using the animal mean sub-model in the DHGLM resulted in biased estimates of variance components, which differed substantially both from a standard linear mean animal model and a sire-dam DHGLM model. Although genetic differences in canalization were observed, selection for increased canalization is difficult, because there is limited individual information for the variance sub-model, especially when based on cross-sectional data. Furthermore, potential macro-environmental changes (diet, climatic region, etc.) may make genetic heterogeneity of variance a less stable trait over time and space.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

P>AimTo compare the efficacy of different digital radiographic imaging systems for determining the length of endodontic files.MethodologyK-type endodontic files were introduced into the canals of 40 extracted human permanent single-rooted teeth and fixed in place at random lengths. The teeth were radiographed using Digora Optime (R), CygnusRay MPS (R) and CDR Wireless (R) digital imaging systems. Six observers measured every file length in all the images and repeated this procedure in 50% of the image samples, and assigned a score to the level of difficulty found. Analysis of variance for differences between digital systems and Tukey's test were performed. The level of intraobserver agreement was measured by intraclass correlation. The assigned scores were evaluated by Kruskal-Wallis and Dunn's tests.ResultsThe CDR Wireless values did not differ significantly from the actual lengths and the CygnusRay MPS values. The Digora Optime system was significantly different from the others and overestimated the values (P < 0.05). The Digora Optime was significantly easier to use for taking measurements and the CygnusRay MPS the most difficult (P < 0.05). All digital radiographic imaging systems showed excellent agreement with the Intraclass Correlation Coefficient > 0.95.ConclusionsThe three digital radiographic imaging systems were precise. The CDR Wireless system was significantly more accurate in determining endodontic file lengths, and similarly to Digora Optime, was considered the least difficult to use when assessing endodontic file lengths.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Geographic differentiation and sexual dimorphism in eighteen morphometric characters of Lutosa brasiliensis (Orthoptera: Henicidae) collected in eight localities of the State of São Paulo (Brazil) were analysed. A two-way Multivariate Analysis of Variance (MONOVA) was used to assess simultaneously the effects of sex and geographic location (plus their interaction) on morphometric variability. The spatial patterns of variation were analysed by Factor and Spatial Autocorrelation Analyses (Moran's I coefficient in four distance classes). Both indicate that the main direction of variation is, for males and females, a north-south cline in overall body size. In females, however, ovipositor length is not correlated with overall body size and displays a different pattern of variation over geographic space, indicating that distinct evolutionary forces produced the geographic differentiation in the species.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three procedures (line transect, point intercept and quadrat) for estimating abundance of macroscopic components of periphyton (macroalgae and bryophytes) were compared in two bedrock streams from southeastern Brazil on the basis of frequency and percent cover. In addition, two quadrat sizes (25 and 50 cm) were tested for best size. Samplings were all made within a 10 m length stream reach. Differences were tested by means of analysis of variance, ANOVA - one way, Student's t test and Chi-square test, whereas associations among them were evaluated by Pearson's r correlation coefficient. Values of frequency and percent cover varied among the different techniques and periphyton species in both sites but ANOVA, t and Chi-square tests revealed no significant difference (p<0.05) for percent cover in the two sites. No consistent pattern was observed for the different procedures between sites. Values for quadrat (25 and 50 cm) percent cover were positively correlated among distinct periphyton species. Significant differences for frequency were found in only one site. Quadrats of 50 cm produced the highest frequency values, whereas point intercept the lowest in both sites. In terms of spatial variation within the stream segment, significant differences were generally observed among all procedures, except between quadrats. As a rule, highly significant correlations for percent cover were found among the different techniques along the stream reach. The strongest relationships were found for quadrats with the other procedures, whereas the weakest between Line and point. Pros and cons of the three techniques are fully discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new methodology for soluble oxalic acid determination in grass samples was developed using a two enzyme reactor in an FIA system. The reactor consisted of 3 U of oxalate oxidase and 100 U of peroxidase immobilized on Sorghum vulgare seeds activated with glutaraldehyde. The carbon dioxide was monitored spectrophotometrically, after reacting with an acid-base indicator (Bromocresol Purple) after it permeated through a PTFE membrane. A linear response range was observed between 0.25 and 1.00mmol l-1 of oxalic acid; the data was fit by the equation A=-0.8(±1.5)+ 57.2(±2.5)[oxalate], with a correlation coefficient of 0.9971 and a relative standard deviation of 2% for n=5. The variance for a 0.25 mmol l-1 oxalic acid standard solution was lower than 4% for 11 measurements. The FIA system allows analysis of 20 samples per hour without prior treatment. The proposed method showed a good correlation with that of the Sigma Kit.