910 resultados para click-and-use software


Relevância:

100.00% 100.00%

Publicador:

Resumo:

A number of medicine selection methods have been used worldwide for formulary purposes. In Northern Ireland, integrated medicines management is being developed, and related projects have been carried out. This paper deals with the description of the STEPS (Safe Therapeutic Economic Pharmaceutical Selection) programme. The paper outlines the development of STEPS and its application as an element of a cost-effective medicines-management process in Northern Ireland.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The implementation of a new model for drug selection in Northern Ireland has improved the quality of prescribing, safety and reduced costs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports an approach by which laboratory based testing and numerical modelling can be combined to predict the long term performance of a range of concretes exposed to marine environments. Firstly, a critical review of the test methods for assessing the chloride penetration resistance of concrete is given. The repeatability of the different test results is also included. In addition to the test methods, a numerical simulation model is used to explore the test data further to obtain long-term chloride ingress trends. The combined use of testing and modelling is validated with the help of long-term chloride ingress data from a North Sea exposure site. In summary, the paper outlines a methodology for determining the long term performance of concrete in marine environments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Clinical Commissioning Groups (CCGs) are mandated to use research evidence effectively to ensure optimum use of resources by the National Health Service (NHS), both in accelerating innovation and in stopping the use of less effective practices and models of service delivery. We intend to evaluate whether access to a demand-led evidence service improves uptake and use of research evidence by NHS commissioners compared with less intensive and less targeted alternatives. 

Methods/design: This is a controlled before and after study involving CCGs in the North of England. Participating CCGs will receive one of three interventions to support the use of research evidence in their decision-making:1) consulting plus responsive push of tailored evidence; 2) consulting plus an unsolicited push of non-tailored evidence; or 3) standard service unsolicited push of non-tailored evidence. Our primary outcome will be changed at 12 months from baseline of a CCGs ability to acquire, assess, adapt and apply research evidence to support decision-making. Secondary outcomes will measure individual clinical leads and managers’ intentions to use research evidence in decision making. Documentary evidence of the use of the outputs of the service will be sought. A process evaluation will evaluate the nature and success of the interactions both within the sites and between commissioners and researchers delivering the service. 

Discussion: The proposed research will generate new knowledge of direct relevance and value to the NHS. The findings will help to clarify which elements of the service are of value in promoting the use of research evidence.Those involved in NHS commissioning will be able to use the results to inform how best to build the infrastructure they need to acquire, assess, adapt and apply research evidence to support decision-making and to fulfil their statutory duties under the Health and Social Care Act.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

(EN)Disclosed are a WC/CNT, WC/CNT/Pt composite material and a preparation process therefor and use thereof. The WC/CNT/Pt composite material comprises mesoporous spherical tungsten carbide with a diameter of 1-5 microns, carbon nanotubes and platinum nano particles, with the carbon nanotubes growing on the surface of the mesoporous spherical tungsten carbide and expanding outward, and the platinum nano particles growing on the surfaces of the mesoporous spherical tungsten carbide and carbon nanotubes. The WC/CNT composite material comprises mesoporous spherical tungsten carbide with a diameter of 1-5 microns, and carbon nanotubes, with the carbon nanotubes growing on the surface of the mesoporous spherical tungsten carbide and expanding outward. The WC/CNT/Pt composite material of the present invention can be used as an electro-catalyst in a methanol flue battery, significantly improving the catalytic conversion rate and the service life of the catalyst. The WC/CNT composite material can be used as an electro-catalyst in the electro-reduction of a nitro aromatic compound, significantly improving the efficiency of organic electro-synthesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Disclosed are a WC/CNT, WC/CNT/Pt composite material and a preparation process therefor and use thereof. The WC/CNT/Pt composite material comprises mesoporous spherical tungsten carbide with a diameter of 1-5 microns, carbon nanotubes and platinum nano particles, with the carbon nanotubes growing on the surface of the mesoporous spherical tungsten carbide and expanding outward, and the platinum nano particles growing on the surfaces of the mesoporous spherical tungsten carbide and carbon nanotubes. The WC/CNT composite material comprises mesoporous spherical tungsten carbide with a diameter of 1-5 microns, and carbon nanotubes, with the carbon nanotubes growing on the surface of the mesoporous spherical tungsten carbide and expanding outward. The WC/CNT/Pt composite material of the present invention can be used as an electro-catalyst in a methanol flue battery, significantly improving the catalytic conversion rate and the service life of the catalyst. The WC/CNT composite material can be used as an electro-catalyst in the electro-reduction of a nitro aromatic compound, significantly improving the efficiency of organic electro-synthesis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Evidence for osseous technologies has featured in excavation reports from Southeast Asia for almost a century and from archaeological deposits as old as 43,000 years BP. However, in contrast to the significance that is placed on this technology in other parts of the world, until recently, Southeast Asian assemblages have drawn only very limited attention. Concentrating on evidence from Malaysia, the current paper examines one element of this inventory of tools: the deliberate modification of pig canines and the means by which such alteration can be distinguished from patterns of natural tooth wear. Particular attention is paid to the bearded pig (Sus barbatus), as it is one of the two species of wild boar in Malaysia whose tusks are most likely to have been used by prehistoric toolmakers. Reference is also made to wider, regional ethnographic examples of known tusk implements and their accredited uses to further assist in the identification process. Distinguishing criteria for worked tusk are formulated according to the type and extent of modification. These criteria are then applied to archaeological specimens recovered from two prehistoric cave sites in Malaysia, Gua Bintong and Niah Cave.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To describe and evaluate a new method for measuring anterior chamber volume (ACV). DESIGN: Observational case series. METHODS: The authors measured ACV using the anterior chamber (AC) optical coherence tomographer (OCT) and applied image-processing software developed by them. Repeatability was evaluated. The ACV was measured in patient groups with normal ACs, shallow ACs, and deep ACs. The volume difference before and after laser peripheral iridotomy (LPI) was analyzed for the shallow and deep groups. RESULTS: Coefficients of repeatability for intraoperator, interoperator, and interimage measurements were 0.406%, 0.958%, and 0.851%, respectively. The limits of agreement for intraoperator and interoperator measurement were -0.911 microl to 1.343 microl and -7.875 microl to -2.463 microl, respectively. There were significant ACV differences in normal, shallow, and deep AC eyes (P < .001) and before and after LPI in shallow AC (P < .001) and deep AC (P = .008) eyes. CONCLUSIONS: The ACV values obtained by this method were repeatable and in accord with clinical observation.