965 resultados para central venous pressure
Resumo:
BACKGROUND The function of naturally existing internal mammary (IMA)-to-coronary artery bypasses and their quantitative effect on myocardial ischemia are unknown. METHODS AND RESULTS The primary end point of this study was collateral flow index (CFI) obtained during two 1-minute coronary artery balloon occlusions, the first with and the second without simultaneous distal IMA occlusion. The secondary study end point was the quantitatively determined intracoronary ECG ST-segment elevation. CFI is the ratio of simultaneously recorded mean coronary occlusive pressure divided by mean aortic pressure both subtracted by mean central venous pressure. A total of 180 pairs of CFI measurements were performed among 120 patients. With and without IMA occlusion, CFI was 0.110±0.074 and 0.096±0.072, respectively (P<0.0001). The difference of CFI obtained in the presence minus CFI obtained in the absence of IMA occlusion was highest and most consistently positive during left IMA with left anterior descending artery occlusion and during right IMA with right coronary artery occlusion (ipsilateral occlusions): 0.033±0.044 and 0.025±0.027, respectively. This CFI difference was absent during right IMA with left anterior descending artery occlusion and during left IMA with right coronary artery occlusion (contralateral occlusions): -0.007±0.034 and 0.001±0.023, respectively (P=0.0002 versus ipsilateral occlusions). The respective CFI differences during either IMA with left circumflex artery occlusion were inconsistently positive. Intracoronary ECG ST-segment elevations were significantly reduced during ipsilateral IMA occlusions but not during contralateral or left circumflex artery occlusions. CONCLUSION There is a functional, ischemia-reducing extracardiac coronary artery supply via ipsilateral but not via contralateral natural IMA bypasses. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCTO1676207.
Resumo:
This article describes in short sections the use and interpretation of indirect blood pressure measurements, central venous pressure, body temperature, pulse oximetry, end tidal CO2 measurements, pulse and heart rate, urine production and emergency laboratory values. Most of these parameters are directly or indirectly linked to the perfusion of the patient. Optimizing these values are one of the most important goals in emergency and critical care medicine.
Resumo:
OBJECTIVE In patients with aortic stenosis, left ventricular systolic torsion (pT) is increased to overcome excessive afterload. This study assessed left ventricular torsion before and immediately after surgical valve replacement and tested the instant effect of fluid loading. DESIGN Prospective, clinical single-center study. SETTING Intensive care unit of a university hospital. PARTICIPANTS 12 patients undergoing elective aortic valve replacement for aortic stenosis. INTERVENTIONS Echocardiography was performed on the day before surgery, within 18 hours after surgery including a fluid challenge, and after 2.5 years. MEASUREMENTS AND MAIN RESULTS pT decreased early postoperatively by 21.2% (23.4° ± 5.6° to 18.4° ± 6.9°; p = 0.012) and reached preoperative values at 2.5 years follow-up (24 ± 7). Peak diastolic untwisting velocity occurred later early postoperatively (13% ± 8% to 21% ± 9.4%; p = 0.019) and returned toward preoperative values at follow-up (10.2 ± 4.7°). The fluid challenge increased central venous pressure (8 ± 4 mmHg to 11 ± 4 mmHg; p = 0.003) and reduced peak systolic torsion velocity (138.7 ± 37.6/s to 121.3 ± 32/s; p = 0.032). pT decreased in 3 and increased in 8 patients after fluid loading. Patients whose pT increased had higher early mitral inflow velocity postoperatively (p = 0.04) than those with decreasing pT. Patients with reduced pT after fluid loading received more fluids (p = 0.04) and had a higher positive fluid balance during the intensive care unit stay (p = 0.03). Torsion after fluid loading correlated with total fluid input (p = 0.001) and cumulative fluid balance (p = 0.002). CONCLUSIONS pT decreased early after aortic valve replacement but remained elevated despite elimination of aortic stenosis. After 2.5 years, torsion had returned to preoperative levels.
Resumo:
BACKGROUND: Fluid resuscitation is a cornerstone of intensive care treatment, yet there is a lack of agreement on how various types of fluids should be used in critically ill patients with different disease states. Therefore, our goal was to investigate the practice patterns of fluid utilization for resuscitation of adult patients in intensive care units (ICUs) within the USA. METHODS: We conducted a cross-sectional online survey of 502 physicians practicing in medical and surgical ICUs. Survey questions were designed to assess clinical decision-making processes for 3 types of patients who need volume expansion: (1) not bleeding and not septic, (2) bleeding but not septic, (3) requiring resuscitation for sepsis. First-choice fluid used in fluid boluses for these 3 patient types was requested from the respondents. Descriptive statistics were performed using a Kruskal-Wallis test to evaluate differences among the physician groups. Follow-up tests, including t tests, were conducted to evaluate differences between ICU types, hospital settings, and bolus volume. RESULTS: Fluid resuscitation varied with respect to preferences for the factors to determine volume status and preferences for fluid types. The 3 most frequently preferred volume indicators were blood pressure, urine output, and central venous pressure. Regardless of the patient type, the most preferred fluid type was crystalloid, followed by 5 % albumin and then 6 % hydroxyethyl starches (HES) 450/0.70 and 6 % HES 600/0.75. Surprisingly, up to 10 % of physicians still chose HES as the first choice of fluid for resuscitation in sepsis. The clinical specialty and the practice setting of the treating physicians also influenced fluid choices. CONCLUSIONS: Practice patterns of fluid resuscitation varied in the USA, depending on patient characteristics, clinical specialties, and practice settings of the treating physicians.
Resumo:
Introducción: El monitoreo hemodinámico es una herramienta para diagnosticar el choque cardiogénico y monitorear la respuesta al tratamiento; puede ser invasivo, mínimamente invasivo o no invasivo. Se realiza rutinariamente con catéter de arteria pulmonar (CAP) o catéter de Swan Ganz; nuevas técnicas de monitoreo hemodinámico mínimamente invasivo tienen menor tasa de complicaciones. Actualmente se desconoce cuál técnica de monitoreo cuenta con mayor seguridad en el paciente con choque cardiogénico. Objetivo: Evaluar la seguridad del monitoreo hemodinámico invasivo comparado con el mínimamente invasivo en pacientes con choque cardiogénico en cuidado intensivo adultos. Diseño: Revisión sistemática de la literatura. Búsqueda en Pubmed, EMBASE, OVID - Cochrane Library, Lilacs, Scielo, registros de ensayos clínicos, actas de conferencias, repositorios, búsqueda de literatura gris en Google Scholar, Teseo y Open Grey hasta agosto de 2016, publicados en inglés y español. Resultados: Se identificó un único estudio con 331 pacientes críticamente enfermos que comparó el monitoreo hemodinámico con CAP versus PiCCO que concluyó que después de la corrección de los factores de confusión, la elección del tipo de monitoreo no influyó en los resultados clínicos más importantes en términos de complicaciones y mortalidad. Dado que se incluyeron otros diagnósticos, no es posible extrapolar los resultados sólo a choque cardiogénico. Conclusión: En la literatura disponible no hay evidencia de que el monitoreo hemodinámico invasivo comparado con el mínimamente invasivo, en pacientes adultos críticamente enfermos con choque cardiogénico, tenga diferencias en cuanto a complicaciones y mortalidad.
Resumo:
Introduzione: L’intervento di Fontan comporta un aumento istantaneo della pressione venosa centrale che causa, nel medio-lungo termine, una forma di epatopatia specifica detta FALD. Il monitoraggio della FALD è complesso ma potrebbe consentire di bloccarne o rallentarne l’insorgenza. Lo studio ha valutato l’efficacia delle modalità di monitoraggio non invasivo. Materiale e metodi: Sei pazienti (età media 24 anni) operati presso l’IRCCS Azienda Ospedaliero Universitaria di Bologna sono stati sottoposti a RMN 4D-Flow e ad Ecodoppler epatico. Sono stati raccolti i dati anagrafici, morfologici, anamnestici e i markers sierologici per il calcolo degli scores MELD-XI, APRI, FIB4, i valori di Shear Stress assiale e circonferenziale e gli indici di pulsatilità e resistenza delle arterie epatica e renale. Risultati: Il tempo trascorso tra la Fontan e lo studio è stato di 17,8 anni. Età media alla Fontan 6,8 anni. Tutti i pazienti avevano un quadro compatibile con epatopatia. I markers sierologici e gli scores MELD-XI,APRI e FIB4 si sono dimostrati di scarsa utilità. All’ecografia tutti i pazienti avevano ecostruttura irregolare, splenomegalia e valori elevati di pulsatilità e resistenza dell’arteria epatica e splenica. La rigidità epatica media è stata di 12,4 Kpa. Alla RMN 4DF lo Shear stress assiale è stato massimo a livello del condotto (0,16 Pa) e minimo a livello delle vene sovra epatiche (0,05 Pa). Lo Shear Stress si è mostrato massimo nei pazienti con emodinamica sfavorevole e peggior quadro ecografico addominale, evidenziando aree di inefficienza energetica. Conclusioni: La combinazione delle diagnostiche di imaging non invasive potrebbe rivelarsi adeguata per il monitoraggio della FALD. In particolare, la RMN 4D Flow potrebbe rivelare aree di inefficienza energetica predisponenti alla FALD. Questo potrebbe indirizzare in modo specifico la terapia dei pazienti operati o addirittura indurre la modifica del disegno della Fontan verso forme più efficienti.
Resumo:
Cannula design is of prime importance for venous drainage during cardiopulmonary bypass (CPB). To evaluate cannulas intended for CPB, an in vitro circuit was set up with silicone tubing between the test cannula encased in a movable preload reservoir and another static reservoir. The pressure-drop (DeltaP) value (P-drainage - P-preload) was measured using Millar pressure transducers. Flow rate (Q) was measured using an ultrasound flowmeter. Data display and data recording were controlled using a LabView application, custom made particularly for our experiments. Our results demonstrated that DeltaP, Q, and cannula resistance (DeltaP/Q) values were significantly decreased when the cannula diameter was increased for Smart and Medtronic cannulas. Smartcanula showed 36% and 43% less resistance compared to Medtronic venous and Medtronic femoral cannulas, respectively. The cannula shape (straight- or curved-tips) did not affect the DLP cannula resistance. Out of five cannulas tested, the Smartcanula outperforms the other commercially available cannulas. The mean (DeltaP/Q) values were 3.3 +/- 0.08, 4.07 +/- 0.08, 5.58 +/- 0.10, 5.74 +/- 0.15, and 6.45 +/- 0.15 for Smart, Medtronic, Edwards, Sarns, and Gambro cannulas, respectively (two-way ANOVA, p < 0.0001). In conclusion, the present assay allows discrimination between different forms of cannula with high or low lumen resistance.
Resumo:
Synbranchus marmoratus is a facultative air-breathing fish, which uses its buccal cavity as well as its gills for air-breathing. S. marmoratus shows a very pronounced tachycardia when it surfaces to air-breathe. An elevation of heart rate decreases cardiac filling time and therefore may cause a decline in stroke volume (VS), but this can be compensated for by an increase in venous tone to maintain stroke volume. Thus, the study on S. marmoratus was undertaken to investigate how stroke volume and venous function are affected during air-breathing. To this end we measured cardiac output (Q), heart rate (fH), central venous blood pressure (PCV), mean circulatory filling pressure (MCFP), and dorsal aortic blood pressures (PDA) in S. marmoratus. Measurements were performed in aerated water (P-O2 > 130 mmHg), when the fish alternated between gill ventilation and prolonged periods of apnoeas, as well as during hypoxia (P-O2 <= 50 mmHg), when the fish changed from gill ventilation to air-breathing. Q increased significantly during gill ventilation compared to apnoea in aerated water through a significant increase in both fH and VS. PCV and MCFP also increased significantly. During hypoxia, when the animals surface to ventilate air, we found a marked rise in fH, PCV, MCFP, Q and VS, whereas PDA decreased significantly. Simultaneous increases in PCV and MCFP in aerated, as well as in hypoxic water, suggests that the venous system plays an important regulatory role for cardiac filling and VS in this species. In addition, we investigated adrenergic regulation of the venous system through bolus infusions of adrenergic agonists (adrenaline, phenylephrine and isoproterenol; 2 mu g kg(-1)). Adrenaline and phenylephrine caused a marked rise in PCV and MCFP, whereas isoproterenol led to a marked decrease in PCV, and tended to decrease MCFP. Thus, it is evident that stimulation of both alpha- and beta-adrenoreceptors affects venous tone in S. marmoratus.
Resumo:
An increase in left ventricular mass (LVM) occurs in the presence of type 2 diabetes, apparently independent of hypertension (1), but the determinants of this process are unknown. Brachial blood pressure is not representative of that at the ascending aorta (2) because the pressure wave is amplified from central to peripheral arteries. Central blood pressure is probably more clinically important since local pulsatile pressure determines adverse arterial and myocardial remodeling (3,4). Thus, an inaccurate assessment of the contribution of arterial blood pressure to LVM may occur if only brachial blood pressure is taken into consideration. In this study we sought the contribution of central blood pressure (and other interactive factors known to affect wave reflection, e.g., glycemic control and total arterial compliance) to LVM in patients with type 2 diabetes.
Resumo:
Intermittent low-dose heparinised saline flushes were found to be efficacious for maintaining patency of indwelling peripheral and central intravenous catheters in diabetic dogs. The catheters were flushed with 1 mL of 1 U/mL heparinised saline every two hours immediately following blood sample collection, or every 12 hours when not being used for sampling. Central catheters were flushed with saline solution first to clear the line before instillation of the heparinised saline. Patency of 54/57 (95%) of the peripheral catheters and 30/32 (94%) of the central catheters was achieved for up to 36 hours and five days, respectively. No phlebitis, or local or systemic infections were observed and, in each case, catheter failure was attributable to obstruction or extravasation. It is unlikely that there will be any contraindications to this flushing technique and its introduction may improve intravenous catheter survival and reduce catheter-associated complications in hospitalised dogs.
Resumo:
Objectivo: Avaliar a incidência de complicações relacionadas com o cateterismo venoso central e a existência de eventuais factores de risco para a sua ocorrência. Material e métodos: Estudo retrospectivo de 305 catéteres venosos centrais colocados pelos médicos da Unidade de Cuidados Intensivos Pediátricos (UCIP) do Hospital Dona Estefânia, durante 5 anos. As variáveis estudadas foram: idade, peso, instituição de ventilação mecânica, alteração da coagulação, local de inserção, número de lúmens e tempo de utilização do catéter, número e tipo de complicações. Na análise estatística foram utilizados o teste do Quiquadrado, o teste exacto de Fisher e o t-teste de Student, considerando-se haver diferenças estatisticamente significativas para valores de p< 0,05. Resultados: Foram submetidos a cateterismo 296 crianças, com idades compreendidas entre 0.08 e 16.00 anos (média=3,6 anos) e pesos entre 2 e 85 Kg (média=16,2 Kg). Os locais de inserção foram, por ordem decrescente de utilização, a veia subclávia (63,3%), a veia femural (29,8%) e veia jugular (6,9%). Os catéteres de duplo lúmen foram os mais utilizados (61,9%), seguidos dos de mono (32,5%) e de triplo lúmen (5,6%). Ocorreram 46 (15,1%) complicações, mas não se verificaram óbitos directamente relacionados com o cateterismo. A remoção do catéter foi electiva em 98 (32,1%) casos, por óbito em 97 (31,8%), por complicações em 39 (12,8%) e por outras causas em 71 (23,2%). O tempo de utilização dos catéteres foi em média de 7,6 dias. Os catéteres com e sem sépsis tiveram uma duração média de utilização de 6,9 dias e 17,0 dias, respectivamente. Conclusões: Este estudo revelou um padrão de complicações do cateterismo venoso central semelhante ao descrito por outros autores, sendo que nenhuma das variáveis analisadas se revelou, por si só, como factor de risco de complicações, excepto o tempo de utilização do catéter na ocorrência de sépsis.
Resumo:
RESUMO - Introdução: As Infeções nosocomiais da corrente sanguínea associada a cateter venoso central (INCS-CVC) provocam um aumento das despesas hospitalares, traduzindo num aumento dos dias de internamento, consumo de antibióticos e de meios complementares de diagnóstico e terapêutica (MCDT). O presente estudo pretende avaliar os custos das INCS-CVC nos serviços de internamento do CHLO, no ano de 2012. Metodologia: Realizou-se um estudo retrospetivo de caso-controlo para determinar os custos adicionais inerentes às INCS-CVC. Foram identificados, em 2012, 32 doentes com infeção e 31 sem infeção. Os controlos foram extraídos da população tendo igual grupo diagnóstico Homogéneo (GDH), idade, sexo, serviço e duração de internamento e presença de CVC. As principais fontes de informação foram os registos da Comissão Controlo de Infeção (CCI) e do processo clinico eletrónico (PCE). A estimativa dos custos teve em consideração a duração de internamento, consumo de antibióticos e de MCDT. Resultados: A idade média dos casos e controlos foi de 66 e 69, respetivamente (p=0,432), 50% dos casos e 51,6% dos controlos eram do sexo masculino. Um total de 22 casos foi comparado com 22 controlos. A duração média de internamento dos casos e controlos foi de 70,8 e 36,6 dias, respetivamente (p=0,000). Em média o custo adicional por doente com antibióticos foi de 256€ (p=0,001). Nos casos o consumo de análises clinica foi 2,5 vezes superior e de exames imagiológicos 2 vezes superior aos controlos. O custo total médio adicional por doente foi de 20.737,6€. Conclusão: A ocorrência de INCS-CVC resultou num aumento significativo de utilização de recursos hospitalares e consequentemente num aumento dos custos hospitalares.
Resumo:
Introduction Vascular access in patients undergoing hemodialysis is considered a critical determinant of bloodstream infection (BSI) and is associated with high morbidity and mortality. The purpose of this study was to investigate the occurrence of BSI in patients with end-stage renal disease using central venous catheters for hemodialysis. Methods A cohort study was conducted in a public teaching hospital in central-western Brazil from April 2010 to December 2011. For every patient, we noted the presence of hyperemia/exudation upon catheter insertion, as well as fever, shivering, and chills during hemodialysis. Results Fifty-nine patients were evaluated. Thirty-five (59.3%) patients started dialysis due to urgency, 37 (62.7%) had BSI, and 12 (20%) died. Hyperemia at the catheter insertion site (64.9%) was a significant clinical manifestation in patients with BSI. Statistical analysis revealed 1.7 times more cases of BSI in patients with hypoalbuminemia compared with patients with normal albumin levels. The principal infective agents identified in blood cultures and catheter-tip cultures were Staphylococcus species (24 cases), non-fermentative Gram-negative bacilli (7 cases of Stenotrophomonas maltophilia and 5 cases of Chryseobacterium indologenes), and Candida species (6). Among the Staphylococci identified, 77.7% were methicillin-resistant, coagulase-negative Staphylococci. Of the bacteria isolated, the most resistant were Chryseobacterium indologenes and Acinetobacter baumannii. Conclusions Blood culture was demonstrated to be an important diagnostic test and identified over 50% of positive BSI cases. The high frequency of BSI and the isolation of multiresistant bacteria were disturbing findings. Staphylococcus aureus was the most frequently isolated microorganism, although Gram-negative bacteria predominated overall. These results highlight the importance of infection prevention and control measures in dialysis units.
Resumo:
PURPOSE: Infection is the leading complication of long-term central venous catheters, and its incidence may vary according to catheter type. The objective of this study was to compare the frequency and probability of infection between two types of long-term intravenous devices. METHODS: Retrospective study in 96 onco-hematology patients with partially implanted catheters (n = 55) or completely implanted ones (n = 42). Demographic data and catheter care were similar in both groups. Infection incidence and infection-free survival were used for the comparison of the two devices. RESULTS: In a median follow-up time of 210 days, the catheter-related infection incidence was 0.2102/100 catheter-days for the partially implanted devices and 0.0045/100 catheter-days for the completely implanted devices; the infection incidence rate was 46.7 (CI 95% = 6.2 to 348.8). The 1-year first infection-free survival ratio was 45% versus 97%, and the 1-year removal due to infection-free survival ratio was 42% versus 97% for partially and totally implanted catheters, respectively (P <.001 for both comparisons). CONCLUSION: In the present study, the infection risk was lower in completely implanted devices than in partially implanted ones.