999 resultados para car spare part


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new ball mill scale-up procedure is developed. This procedure has been validated using seven sets of Ml-scale ball mil data. The largest ball mills in these data have diameters (inside liners) of 6.58m. The procedure can predict the 80% passing size of the circuit product to within +/-6% of the measured value, with a precision of +/-11% (one standard deviation); the re-circulating load to within +/-33% of the mass-balanced value (this error margin is within the uncertainty associated with the determination of the re-circulating load); and the mill power to within +/-5% of the measured value. This procedure is applicable for the design of ball mills which are preceded by autogenous (AG) mills, semi-autogenous (SAG) mills, crushers and flotation circuits. The new procedure is more precise and more accurate than Bond's method for ball mill scale-up. This procedure contains no efficiency correction which relates to the mill diameter. This suggests that, within the range of mill diameter studied, milling efficiency does not vary with mill diameter. This is in contrast with Bond's equation-Bond claimed that milling efficiency increases with mill diameter. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cost and risk associated with mineral exploration in Australia increases significantly as companies move into deeper regolith-covered terrain. The ability to map the bedrock and the depth of weathering within an area has the potential to decrease this risk and increase the effectiveness of exploration programs. This paper is the second in a trilogy concerning the Grant's Patch area of the Eastern Goldfields. The recent development of the VPmg potential field inversion program in conjunction with the acquisition of high-resolution gravity data over an area with extensive drilling provided an opportunity to evaluate three-dimensional gravity inversion as a bedrock and regolith mapping tool. An apparent density model of the study area was constructed, with the ground represented as adjoining 200 m by 200 m vertical rectangular prisms. During inversion VPmg incrementally adjusted the density of each prism until the free-air gravity response of the model replicated the observed data. For the Grant's Patch study area, this image of the apparent density values proved easier to interpret than the Bouguer gravity image. A regolith layer was introduced into the model and realistic fresh-rock densities assigned to each basement prism according to its interpreted lithology. With the basement and regolith densities fixed, the VPmg inversion algorithm adjusted the depth to fresh basement until the misfit between the calculated and observed gravity response was minimised. The resulting geometry of the bedrock/regolith contact largely replicated the base of weathering indicated by drilling with predicted depth of weathering values from gravity inversion typically within 15% of those logged during RAB and RC drilling.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research is part of a project whose scope was to investigate the engineering properties of new non-commercial alloy formulations based on the Cu rich corner of the Cu-Fe-Cr ternary system with the primary aim of exploring the development of a new cost-effective high-strength, high-conductivity copper alloy. The literature indicated that Cu rich Cu-Cr and Cu-Fe alloys have been thoroughly investigated. A number of commercial alloys have been developed and these are used for a variety of applications requiring combinations of high-strength, high-conductivity and resistance to softening. Little evidence was found in the literature that the Cu rich corner of the Cu-Fe-Cr system had previously been investigated for the purpose of developing high-strength, high-conductivity copper alloys resistant to softening. The aim of these present investigations was to explore the possibility that new alloys could be developed that combined the properties of both sets of alloys, ie large precipitation hardening response combined with the ability to stabilise cold worked microstructures to high temperatures while at the same maintain high electrical conductivity. To assess the feasibility of this goal the following alloys were chosen for investigation: Cu-0.7wt%Cr-0.3wt%Fe, Cu-0.7wt%Cr-0.8wt%Fe, Cu-0.7wt%Cr-2.0wt%Fe. This paper reports on the mechanical property investigation which indicated that the Cu-0.7wt%Cr-0.3wt%Fe, and Cu-0.7wt%Cr-2.0wt%Fe alloys were worthy of further investigation. (C) 2001 Kluwer Academic Publishers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research is part of a project whose scope was to investigate the engineering properties of new non-commercial alloy formulations based on the Cu rich corner of the Cu-Fe-Cr ternary system with the primary aim of exploring the development of a new cost-effective high-strength, high-conductivity copper alloy. Promising properties have been measured for the following alloys: Cu-0.7wt%Cr-0.3wt%Fe and Cu-0.7wt%Cr-2.0wt%Fe. This paper reports on the microstructural characterisation of these alloys and discusses the mechanical and electrical properties of these alloys in terms of their microstructure, particularly the formation of precipitates. These alloys have evinced properties that warrant further investigation. Cost modelling has shown that Cu-0.7wt%Cr-0.3wt%Fe is approximately 25% cheaper to produce than commercial Cu-1%Cr. It has also been shown to be more cost efficient on a yield stress and % IACS per dollar basis. The reason for the cost saving is that the Cu-0.7%Cr-0.3%Fe alloy can be made with low carbon ferro-chrome additions as the source of chromium rather than the more expensive Cu-Cr master-alloy. For applications in which cost is one of the primary materials selection criteria, it is envisaged that there would be numerous applications in both cast and wrought form, where the Cu-0.7%Cr-0.3%Fe alloy would be more suitable than Cu-1%Cr. (C) 2001 Kluwer Academic Publishers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To examine the feasibility and safety of a low anterior resection of the rectosigmoid plus adjacent pelvic tumour as part of primary cytoreduction for ovarian cancer. Methods. This study included 65 consecutive patients with primary ovarian cancer who had debulking surgery from 1996 through 2000. All patients underwent an en bloc resection of ovarian cancer and a rectosigmoid resection followed by an end-to-end anastomosis. Parameters for safety and efficacy were considered as primary statistical endpoints for the aim of this analysis. Results. Postoperative residual tumour was nil, 1 cm in 14, 34, and 14 patients, respectively. The median postoperative hospital stay was 11 days (range, 6 to 50 days). Intraoperative complications included an injury to the urinary bladder in one patient. Postoperative complications included wound complications (n=14, 21.5%), septicemia (n=9, 13.8%), cardiac complications (n=7, 10.8%), thromboembolic complications (n=5, 7.7%) ileus (n=2, 3.1%) anastomotic leak (n=2, 3.1%) and fistula (n=1, 1.5%). Reasons for a reoperation during the same admission included repair of an anastomotic leak (n=1), postoperative hemorrhage (n=1), and wound debridement (n=1). Wound complications, septicemia, and anastomotic leak formation were more frequent in patients who had a serum albumin level of less than or equal to 30 g/L preoperatively. There was one surgically related mortality in a patient who died from a cerebral vascular accident 2 days postoperatively. Conclusions. An en bloc resection as part of primary cytoreductive surgery for ovarian cancer is effective and its morbidity is acceptably low. (C) 2001 Academic Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To demonstrate that the combination of impression cytology and single cell DNA fingerprinting represents a powerful tool that is suitable for detecting transplanted cells after corneal limbal allografting. Methods, Fifty single cells were obtained by corneal impression cytology from 12 patients undergoing cataract surgery. Individual cells were isolated from samples by micromanipulation. Polymerase chain reaction and short tandem repeat profiling was used to obtain forensic standard DNA fingerprints from single cells. Blood samples taken at the time of impression cytology provided control fingerprints. Results, informative DNA fingerprints were obtained from all corneal samples and 66% (33 of 50 cells) of isolated single cells, Of all fingerprints obtained, most (91%, 30 of 33 fingerprints) corneal fingerprints matched corresponding blond sample fingerprints. At least one corneal fingerprint matched the corresponding blood sample fingerprint in 83% (10 of 12 patients) of the patients in the study, Conclusions. This extremely specific single cell DNA fingerprinting system permits accurate identification of individual corneal epithelial cells, allowing very reliable determination of their origin, which will enable host and donor cells to be distinguished from each other after keratolimbal allografting procedures. even if the host and donor are the same sex or siblings. These DNA fingerprinting methods allow assessment of quality and quantity of donor cell survival, as well as survival time. The extreme sensitivity and accuracy of the technique means that should contamination occur, it would be identified, thus ensuring meaningful results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An archaeological survey on Peel Island in Moreton Bay, southeast Queensland, was conducted to assist the conservation planning for the Peel Island Lazaret (PIL), one of a number of institutions housed on the island during the nineteenth and twentieth centuries. The survey revealed a patteming of artefacts across the island as well as landscape modification related to its Aboriginal and European institutional uses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: First, to assess the clinical effectiveness of hylan G-F 20 in an appropriate care treatment regimen (as defined by the American College of Rheumatology (ACR) 1995 guidelines) as measured by validated disease-specific outcomes and health-related quality of life endpoints for patients with osteoarthritis (OA) of the knee. Second, to utilize the measures of effectiveness and costs in an economic evaluation (see accompanying manuscript). Design: A total of 255 patients with OA of the knee were enrolled by rheumatologists or orthopedic surgeons into a prospective, randomized, open-label, 1-year, multi-centred trial, conducted in Canada. Patients were randomized to 'Appropriate care with hylan G-F 20' (AC+H) or 'Appropriate care without hylan G-F 20' (AC). Data were collected at clinic visits (baseline, 12 months) and by telephone (1, 2, 4, 6, 8, 10, and 12 months). Results: The AC+H group was superior to the AC group for all primary (% reduction in mean Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) pain scale: 38% vs 13%, P=0.0001) and secondary effectiveness outcome measures. These differences were all statistically significant and exceeded the 20% difference between groups seta priori by the investigators as the minimum clinically important difference. Health-related quality of life improvements in the AC+H group were statistically superior for the WOMAC pain, stiffness and physical function (all P