191 resultados para calorimetric


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oxidative stress is related with physiopathology of diabetes mellitus type II and with its secondary complications, such as diabetic nephropathy. Thus, the purpose of this study was to examine the effects of n-acetylcysteine NAC, an antioxidant from Allium cepa, on oxidative stress, morphometrical and nutritional parameters and basal metabolism and energetic substrate utilization, serum glucose and oral glucose tolerance test (OGTT), and renal function of high-sucrose intake rats. Animals were initially divided into three groups. Rats in the control group (C; n=10) were given free access to a standard chow and water; (S; n=10) group received standard chow and 30% sucrose in its drinking water; (SN; n=5) group received standard chow and 2g/L NAC and 30% sucrose in its drinking water. After 25 days of treatments, rats were submitted to indirect calorimetry in fasted and feed states. After 30 days of treatments, rats from C and S groups were divided into four groups of five rats each. The (CC) and (SS) groups were given an intra-gastric dose 0,6mL saline (0,9%NaCl) and the (CNAC) and (SNAC) groups were treated with a intra-gastric dose of 0,6mL NAC (160g/day), and then everybody received a intra-gastric dose of glucose solution (20%) for the OGTT. Animals of S and SN groups have higher liquid consumption and lower food consumption than C group. Calorimetric analyses confirm that despite of the final body weight had not statistical difference among groups, S group have lower resting metabolic rate when compared to C and SN animals. Besides, S group has higher respiratory quotient, higher carbohydrate oxidation and lower lipid oxidation, both in fasted and feed states, than C and SN groups, evidencing the beneficial effect of NAC. Fasting plasma glucose is increased in SS and SNAC animals when compared to CC and CNAC, however SN group has glicemic level at 30 min before OGTT decreased when ...(Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is a great global concern about the depletion and the high cost of fossil fuel reserves exploitation, more than ever, it is necessary to make a profound study and take advantage of alternative sources that can be used as energy efficiency with an appropriate pricing and low environmental impact. Brazil, which has highlighted using alternative energy sources as the use of ethanol and, in recent years, has been encouraging the expansion of its energy matrix in which the biodiesel will have a strategic importance within the agrobusiness area. Biodiesel is a fuel that can replace the diesel, which is a petroleum derivative. It is an ester, produced in the transesterification reaction of vegetable oils and animal greases, in an alcohol with an additional catalyst, are converted into fatty acids and result in esters with glycerol as sub products. The objective of this study was to estimate the final energy balance for the process biodiesel production from oil chicken waste. The energy balance estimation was quantified in calorific value according to the energy expenditure by calorimetric bomb method. The relationship between input and output of energy was around 0.97. In a first evaluation, the procedures adopted should be improved enough, so the process can become energetic and economically viable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We compare experimental and predicted differential scanning calorimetry (DSC) curves for palm oil (PO), peanut oil (PeO) and grapeseed oil (GO). The predicted curves are computed from the solid-liquid equilibrium modelling and direct minimization of the Gibbs free energy. For PO, the lower the scan rate, the better the agreement. The temperature transitions of PeO and GO were predicted with an average deviation of -0.72 degrees C and -1.29 degrees C respectively, in relation to experimental data from literature. However, the predicted curves showed other peaks not reported experimentally, as computed DSC curves correspond to equilibrium hypothesis which is reached experimentally for an infinitely small scan rate. The results revealed that predicted transitions temperatures using equilibrium hypotheses can be useful in pre-experimental evaluation of vegetable oils formulations seeking for desired melting profiles. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ELECTROCHEMICAL AND CALORIMETRIC INVESTIGATION OF INTERACTION OF NOVEL BISCATIONIC ANTICANCER AGENTS WITH DNA. Biscationic amidines bind in the DNA minor groove and present biological activity against a range of infectious diseases. Two new biscationic compounds (bis-alpha,omega-S-thioureido, amino and sulfide analogues) were synthesized in good yields and fully characterized, and their interaction with DNA was also investigated. Isothermal titration calorimetry (ITC) was used to measure the thermodynamic properties of binding interactions between DNA and these ligands. A double stranded calf thymus DNA immobilized on an electrode surface was used to study the possible DNA-interacting abilities of these compounds towards dsDNA in situ. A remarkable interaction of these compounds with DNA was demonstrated and their potential application as anticancer agents was furthered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biscationic amidines bind in the DNA minor groove and present biological activity against a range of infectious diseases. Two new biscationic compounds (bis-α,ω-S-thioureido, amino and sulfide analogues) were synthesized in good yields and fully characterized, and their interaction with DNA was also investigated. Isothermal titration calorimetry (ITC) was used to measure the thermodynamic properties of binding interactions between DNA and these ligands. A double stranded calf thymus DNA immobilized on an electrode surface was used to study the possible DNA-interacting abilities of these compounds towards dsDNA in situ. A remarkable interaction of these compounds with DNA was demonstrated and their potential application as anticancer agents was furthered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Pierre Auger Observatory in Malargüe, Argentina, is designed to study the properties of ultra-high energy cosmic rays with energies above 1018 eV. It is a hybrid facility that employs a Fluorescence Detector to perform nearly calorimetric measurements of Extensive Air Shower energies. To obtain reliable calorimetric information from the FD, the atmospheric conditions at the observatory need to be continuously monitored during data acquisition. In particular, light attenuation due to aerosols is an important atmospheric correction. The aerosol concentration is highly variable, so that the aerosol attenuation needs to be evaluated hourly. We use light from the Central Laser Facility, located near the center of the observatory site, having an optical signature comparable to that of the highest energy showers detected by the FD. This paper presents two procedures developed to retrieve the aerosol attenuation of fluorescence light from CLF laser shots. Cross checks between the two methods demonstrate that results from both analyses are compatible, and that the uncertainties are well understood. The measurements of the aerosol attenuation provided by the two procedures are currently used at the Pierre Auger Observatory to reconstruct air shower data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

[EN] The correct determination of the energy generated or absorbed in the sample cell of an Isothermal Titration Calorimeter (ITC) requires a thorough analysis of the calorimetric signal. This means the identification and quantification of any thermal effect inherent to the working method. In this work, it is carried out a review on several thermal effects, studied by us in previous work, and which appear when an ITC is used for measuring the heats of mixing of liquids in a continuous mode. These effects are due to: (i) the difference between the temperature of the injected liquid and the temperature of the mixture during the mixing process, (ii) the increase of the liquid volume located in the mixing cell and (iii) the stirring velocity. Besides, methods for the identification and quantification of the mentioned effects are suggested.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Im Rahmen der vorliegenden Arbeit wurden zum ersten Mal kalorimetrische Tieftemperatur-Detektoren in der Beschleuniger-Massenspektrometrie (Accelerator Mass Spectrometry AMS), einer Standard-Methode zur Bestimmung kleinster Isotopenverhältnisse, eingesetzt, um das Isotopenverhältnis von 236U zu 238U zu bestimmen. Das Uran-Isotop 236U entsteht in der Neutroneneinfang-Reaktion 235U(n,gamma)236U und kann daher als Monitor-Nuklid für Neutronenflüsse verwendet werden. Die Detektoren bestehen aus einem Saphir-Absorber, auf den ein supraleitender Aluminium-Film aufgedampft ist, der als Thermistor dient. Ein energetisches Schwerion deponiert seine kinetische Energie als Wärme im Absorber, dessen Temperaturänderung durch die Widerstandsänderung des Supraleiters nachgewiesen wird. Mit solchen Detektoren konnte in vorhergehenden Experimenten bei GSI in einem Energiebereich von E = 5 - 300 MeV/amu für eine Vielzahl von Ionen von Neon bis Uran eine relative Energieauflösung von (1 - 4) E-3 erreicht werden. Der für die Beschleuniger-Massenspektrometrie typische Energiebereich liegt bei E = 0.1 - 1 MeV/amu. Im ersten Schritt wurde daher die systematische Untersuchung der Detektoreigenschaften auf diesen Energiebereich ausgedehnt. Diese Untersuchungen sowie die AMS-Messungen wurden am Tandem-Beschleuniger VERA des Instituts für Isotopenforschung und Kernphysik der Universität Wien durchgeführt. In einem Energiebereich von 10 - 60 MeV konnte für verschiedene Ionen (13C, 197Au, 238U) zunächst eine relative Energieauflösung von DeltaE/E = 7 E-3 erreicht werden. Dies übertrifft die Auflösung konventioneller Ionisations-Detektoren um ca. eine Größenordnung. Durch eine Verbesserung thermischer und elektronischer Rauschbeiträge konnte in einem zweiten Experiment für Uran der Energie 17 MeV die Auflösung auf DeltaE/E = 4.6 E-3 verbessert werden. Die Energie-Response des Detektors war linear über den gesamten beobachteten Energiebereich und unabhängig von der Ionenmasse; bis auf ein Niveau von 0.1 % wurde kein Pulshöhendefekt beobachtet. Diese Ergebnisse zeigen, daß solche Detektoren ein wertvolles Werkzeug in der Schwerionenphysik im Bereich relativ niedriger Ionenenergien darstellen. Mit der erreichten Energieauflösung war es möglich, für mehrere Proben aus natürlichem Uran das Isotopenverhältnis 236U/238U zu bestimmen: Um einen Material-Standard für Uran in der AMS zu etablieren, wurde das Isotopenverhältnis 236U/238U für zwei Proben aus der Mine ''K.u.K. Joachimsthal'' möglichst präzise bestimmt. Die Ergebnisse in der vorliegenden Arbeit stimmen gut mit früheren Messungen überein, die mit einem konventionellen Detektorsystem durchgeführt wurden. Sowohl der statistische als auch der systematische Fehler konnten deutlich reduziert werden. Für eine weitere Probe, extrahiert aus dem Wasser einer Uran-haltigen Quelle in Bad Gastein, wurde ein Isotopenverhältnis von 6.1 E-12 gemessen. Dies stellt das kleinste bislang für 236U/238U gemessene Isotopenverhältnis dar und bedeutet eine Steigerung der Sensitivität um eine Größenordnung. Die erreichte Energieauflösung ermöglicht es außerdem, die Detektoren zur direkten Massenidentifikation von schweren Ionen mittels einer kombinierten Energie-Flugzeit-Messung einzusetzen. In ersten Test-Messungen im Rahmen der vorliegenden Arbeit wurde eine Massenauflösung von DeltaM/M = (8.5 - 11.0) E-3 erreicht. In einem ersten Test für den Einsatz dieser Detektoren zum Nachweis sog. ''superschwerer Elemente (Z >= 112)'' erlaubte der große dynamische Bereich, die Reaktionsprodukte und ihre nachfolgenden Alpha-Zerfälle mit hoher Energieauflösung simultan und zeitaufgelöst nachzuweisen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to investigate the evaporation dynamics of water microdrops deposited on atomic force microscope cantilevers, which were employed as sensitive stress, mass and temperature sensors with high time resolution. The technique has some advantages with respect to video-microscope imaging and ultra-precision weighting with electronic microbalances or quartz crystal microbalances, since it allows to measure more drop parameters simultaneously for smaller drop sizes. On hydrophobic surfaces a single measurement with a silicon cantilever provides data for the drop mass, contact angle and radius until very close to complete evaporation. On hydrophilic surfaces, it is as well possible to measure drop mass and inclination of the cantilever. The technique further allows to detect differences between water microdrops evaporating from clean hydrophilic and hydrophobic surfaces. On hydrophilic surfaces the cantilever inclination is negative at the end of the evaporation process. Negative inclination mostly occurs when drops are pinned. This effect can not be detected with any of the other well-established methods. The evidence arises that on the hydrophilic surface a thin water film forms, while this is not the case for the hydrophobic surface. Metal coated cantilevers can be used as thermometers, and allow to precisely measure the temperature of an evaporating microdrop. This can be relevant for further applications of cantilevers as calorimetric sensors for chemical reactions taking place in drops on their surface. The applicability of Young’s equation was verified for microdrops. It was shown that Young’s equation can not be applied to microscopic drops due to their fast evaporation. A study on evaporation of microdrops in saturated vapor atmosphere was performed to estimate evaporation times and compare them with a theory developed, which relates the initial drop volume with the overall evaporation time.