935 resultados para anterior segment length


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purtscher-like retinopathy is associated with retinal hemorrhages and ischaemia probably due to the complement-mediated leukoembolization. It is a rare and severe angiopathy found in conditions such as acute pancreatitis. Case. We present a case of a 53-year-old man who presented with a Purtscher-like retinopathy associated with the development of acute pancreatitis in the context of a Klatskin tumour (a hilar cholangiocarcinoma). The ophthalmologic evaluation revealed the best corrected visual acuity (BCVA) of 20/32 in the right eye (RE) and of 20/40 in the left eye (LE); biomicroscopy of anterior segment showed scleral icterus and fundoscopy revealed peripapillary cotton-wool spots, optic disc edema, and RPE hypo- and hyperpigmentation in the middle peripheral retina in both eyes with an intraretinal hemorrhage in the LE. 15 months after the initial presentation, without ophthalmological treatment, there was an improvement of BCVA to 20/20 in both eyes and optical coherence tomography (OCT) revealed areas of reduction of retinal nerve fiber layer thickness corresponding to the previous cotton-wool spots. Conclusion. Purtscher-like retinopathy should not be neglected in complex clinical contexts. Its unclear pathophysiology determines an uncertain treatment strategy, but a meticulous follow-up is compulsory in order to avoid its severe complications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This thesis describes the application of multispectral imaging to several novel oximetry applications. Chapter 1 motivates optical microvascular oximetry, outlines oxygen transport in the body, describes the theory of oximetry, and describes the challenges associated with in vivo oximetry, in particular imaging through tissue. Chapter 2 reviews various imaging techniques for quantitative in vivo oximetry of the microvasculature, including multispectral and hyperspectral imaging, photoacoustic imaging, optical coherence tomography, and laser speckle techniques. Chapter 3 describes a two-wavelength oximetry study of two microvascular beds in the anterior segment of the eye: the bulbar conjunctival and episcleral microvasculature. This study reveals previously unseen oxygen diffusion from ambient air into the bulbar conjunctival microvasculature, altering the oxygen saturation of the bulbar conjunctiva. The response of the bulbar conjunctival and episcleral microvascular beds to acute mild hypoxia is quantified and the rate at which oxygen diffuses into bulbar conjunctival vessels is measured. Chapter 4 describes the development and application of a highly novel non-invasive retinal angiography technique: Oximetric Ratio Contrast Angiography (ORCA). ORCA requires only multispectral imaging and a small perturbation of blood oxygen saturation to produce angiographic sequences. A pilot study of ORCA in human subjects was conducted. This study demonstrates that ORCA can produce angiographic sequences with features such as sequential vessel filling and laminar flow. The application and challenges of ORCA are discussed, with emphasis on comparison with other angiography techniques, such as fluorescein angiography. Chapter 5 describes the development of a multispectral microscope for oximetry in the spinal cord dorsal vein of rats. Measurements of blood oxygen saturation are made in the dorsal vein of both healthy rats, and in rats with the Experimental autoimmune encephalomyelitis (EAE) disease model of multiple sclerosis. The venous blood oxygen saturation of EAE disease model rats was found to be significantly lower than that of healthy controls, indicating increased oxygen uptake from blood in the EAE disease model of multiple sclerosis. Chapter 6 describes the development of video-rate red eye oximetry; a technique which could enable stand-off oximetry of the blood-supply of the eye with high temporal resolution. The various challenges associated with video-rate red eye oximetry are investigated and their influence quantified. The eventual aim of this research is to track circulating deoxygenation perturbations as they arrive in both eyes, which could provide a screening method for carotid artery stenosis, which is major risk-factor for stroke. However, due to time constraints, it was not possible to thoroughly investigate if video-rate red eye can detect such perturbations. Directions and recommendations for future research are outlined.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: This is a clinical study of our experience using pedicle perforator flaps to cover skin defects in the middle and distal segment of the leg. Design: Prospective study. Setting: University hospital. Patients/Intervention: Twenty-four patients underwent treatment of a skin defect in the middle or distal segment of the leg by means of pedicled flaps based on perforating arteries. The perforating arteries were located before the operation by means of echo-Doppler examination. The flaps were planned in propeller fashion (21 cases) and as advancement (three cases). Main Outcome Measurements: The results were evaluated according the origin of perforator flap, size of the flap, and donor area and viability of the flap. The success rate of the echo-Doppler to identify the location of perforator vessel was also evaluated. Results: In nine cases, the perforating vessels originated from the fibular artery, in 10 the posterior tibial artery, and in five the anterior tibial artery. The mean size of the flaps was 5 cm in width by 12 cm in length. The success rate using an echo-Doppler was 87%. The flaps were fully viable in 20 cases and partially viable in four cases. Conclusion: On the basis of these results, it is concluded that perforating flaps are a good choice of treatment for skin losses, especially in the distal segment of the leg, and could be an alternative option for the use of free microsurgical flaps.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To assess coronary stent placement in patients with multivessel coronary disease and involvement of the proximal portion of the anterior descending coronary artery. METHODS: We retrospectively analyzed the in-hospital and late evolution of 189 patients with multivessel coronary disease, who underwent percutaneous coronary stent placement. These patients were divided into 2 groups as follows: group I (GI) - 59 patients with involvement of the proximal segment of the anterior descending coronary artery; and group II (GII) - 130 patients without involvement of the proximal segment of the anterior descending coronary artery. RESULTS: No significant difference was observed in the success rate of the procedure (91.5% versus 97.6%, p=0.86), nor in the occurrence of major adverse cardiac events (5.1% versus 1.5%, p=0.38), nor in the occurrence of major vascular complications (1.7% versus 0%, p=0.69) in the in-hospital phase. In the late follow-up, the incidence of major adverse cardiac events (15.4% versus 13.7%, p=0.73) and the need for new revascularization (13.5% versus 10.3%, p=0.71) were similar for both groups. CONCLUSION: The in-hospital and late evolution of patients with multivessel coronary disease with and without involvement of the proximal segment of the anterior descending coronary artery treated with coronary stent placement did not differ. This suggests that this revascularization method is an effective procedure and a valuable option for treating these types of patients.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The ciliary body and iris are pigmented epithelial structures in the anterior eye segment that function to maintain correct intra-ocular pressure and regulate exposure of the internal eye structures to light, respectively. The cellular and molecular factors that mediate the development of the ciliary body and iris from the ocular pigmented epithelium remain to be fully elucidated. Here, we have investigated the role of Notch signaling during the development of the anterior pigmented epithelium by using genetic loss- and gain-of-function approaches. Loss of canonical Notch signaling results in normal iris development but absence of the ciliary body. This causes progressive hypotony and over time leads to phthisis bulbi, a condition characterized by shrinkage of the eye and loss of structure/function. Conversely, Notch gain-of-function results in aniridia and profound ciliary body hyperplasia, which causes ocular hypertension and glaucoma-like disease. Collectively, these data indicate that Notch signaling promotes ciliary body development at the expense of iris formation and reveals novel animal models of human ocular pathologies.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: This study evaluated the variations in the anterior cranial base (S-N), posterior cranial base (S-Ba) and deflection of the cranial base (SNBa) among three different facial patterns (Pattern I, II and III). Method: A sample of 60 lateral cephalometric radiographs of Brazilian Caucasian patients, both genders, between 8 and 17 years of age was selected. The sample was divided into 3 groups (Pattern I, II and III) of 20 individuals each. The inclusion criteria for each group were the ANB angle, Wits appraisal and the facial profile angle (G’.Sn.Pg’). To compare the mean values obtained from (SNBa, S-N, S-Ba) each group measures, the ANOVA test and Scheffé’s Post-Hoc test were applied. Results and Conclusions: There was no statistically significant difference for the deflection angle of the cranial base among the different facial patterns (Patterns I, II and III). There was no significant difference for the measures of the anterior and posterior cranial base between the facial Patterns I and II. The mean values for S-Ba were lower in facial Pattern III with statistically significant difference. The mean values of S-N in the facial Pattern III were also reduced, but without showing statistically significant difference. This trend of lower values in the cranial base measurements would explain the maxillary deficiency and/or mandibular prognathism features that characterize the facial Pattern III.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

We seek to examine the efficacy and safety of prereperfusion emergency medical services (EMS)–administered intravenous metoprolol in anterior ST-segment elevation myocardial infarction patients undergoing eventual primary angioplasty. This is a prespecified subgroup analysis of the Effect of Metoprolol in Cardioprotection During an Acute Myocardial Infarction trial population, who all eventually received oral metoprolol within 12 to 24 hours. We studied patients receiving intravenous metoprolol by EMS and compared them with others treated by EMS but not receiving intravenous metoprolol. Outcomes included infarct size and left ventricular ejection fraction on cardiac magnetic resonance imaging at 1 week, and safety by measuring the incidence of the predefined combined endpoint (composite of death, malignant ventricular arrhythmias, advanced atrioventricular block, cardiogenic shock, or reinfarction) within the first 24 hours. From the total population of the trial (N=270), 147 patients (54%) were recruited during out-of-hospital assistance and transferred to the primary angioplasty center (74 intravenous metoprolol and 73 controls). Infarct size was smaller in patients receiving intravenous metoprolol compared with controls (23.4 [SD 15.0] versus 34.0 [SD 23.7] g; adjusted difference –11.4; 95% confidence interval [CI] –18.6 to –4.3). Left ventricular ejection fraction was higher in the intravenous metoprolol group (48.1% [SD 8.4%] versus 43.1% [SD 10.2%]; adjusted difference 5.0; 95% CI 1.6 to 8.4). Metoprolol administration did not increase the incidence of the prespecified safety combined endpoint: 6.8% versus 17.8% in controls (risk difference –11.1; 95% CI –21.5 to –0.6). Out-of-hospital administration of intravenous metoprolol by EMS within 4.5 hours of symptom onset in our subjects reduced infarct size and improved left ventricular ejection fraction with no excess of adverse events during the first 24 hours.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Avaliar os efeitos da infiltração de dióxido de carbono em adipócitos presentes na parede abdominal. MÉTODOS: Quinze voluntárias foram submetidas a sessões de infusão de CO2 durante três semanas consecutivas (duas sessões por semana com intervalos de dois a três dias entre cada sessão). O volume de gás carbônico infundido por sessão, em pontos previamente demarcados, foi sempre calculado com base na superfície da área a ser tratada, com volume infundido fixo de 250 mL/100cm² de superfície tratada. Os pontos de infiltração foram demarcados respeitando-se o limite eqüidistante 2cm entre eles. Em cada ponto se injetou 10mL, por sessão, com fluxo de 80mL/min. Foram colhidos fragmentos de tecido celular subcutâneo da parede abdominal anterior antes e após o tratamento. O número e as alterações histomorfológicas dos adipócitos (diâmetro médio, perímetro, comprimento, largura e número de adipócitos por campos de observação) foram mensurados por citometria computadorizada. Os resultados foram analisados com o teste t de Student pareado, adotando-se nível de significância de 5% (p<0,05). RESULTADOS: Encontrou-se redução significativa no número de adipócitos da parede abdominal e na área, diâmetro, perímetro, comprimento e largura após o uso da hipercapnia (p=0,0001). CONCLUSÃO: A infiltração percutânea de CO2 reduz a população e modifica a morfologia dos adipócitos presentes na parede abdominal anterior.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To describe the microsurgical anatomy, branches, and anatomic relationships of the posterior cerebral artery (PCA) represented in three-dimensional images. METHODS: Seventy hemispheres of 35 brain specimens were studied. They were previously injected with red silicone and fixed in 10% formalin for at least 40 days. Four of the studied specimens were frozen at -10 degrees to -15 degrees C for 14 days, and additional dissection was done with the Klingler`s fiber dissection technique at x6 to x40 magnification. Each segment of the artery was measured and photographed to obtain three-dimensional stereoscopic images. RESULTS: The PCA origin was in the interpeduncular cistern at the pontomesencephalic junction level in 23 specimens (65.7%). The PCA was divided into four segments: P1 extends from the PCA origin to its junction with the posterior communicating artery with an average length of 7.7 mm; P2 was divided into an anterior and posterior segment. The P2A segment begins at the posterior communicating artery and ends at the most lateral aspect of the cerebral peduncle, with an average length of 23.6 mm, and the P2P segment extends from the most lateral aspect of the cerebral peduncle to the posterior edge of the lateral surface of the midbrain, with an average length of 16.4 mm; P3 extends from the posterior edge of the lateral surface of the midbrain and ends at the origin of the parieto-occipital sulcus along the calcarine fissure, with an average length of 19.8 mm; and the P4 segment corresponds to the parts of the PCA that run along or inside both the parieto-occipital sulcus and the distal part of the calcarine fissure. CONCLUSIONS: To standardize the neurosurgical practice and knowledge, surgical anatomic classifications should be used uniformly and further modified according to the neurosurgical experience gathered. The PCA classification proposed intends to correlate its anatomic segments with their required microneurosurgical approaches.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evidence that combined glucosamine sulfate and chondroitin sulfate (Gluchon) or isolated glucosamine (Glu) modifies joint damage in osteoarthritis (OA) is still lacking. We studied joint pain and cartilage damage using the anterior cruciate ligament transection (ACLT) model. Wistar rats were subjected to ACLT of the right knee ( OA) or sham operation. Groups received either Glu (500 mg/kg), Gluchon (500 mg/kg glucosamine +400 mg/kg chondroitin) or vehicle (non-treated-NT) per os starting 7 days prior to ACLT until sacrifice at 70 days. Joint pain was evaluated daily using the rat-knee joint articular incapacitation test. Structural joint damage was assessed using histology and biochemistry as the chondroitin sulfate ( CS) content of cartilage by densitometry (microgram per milligram dried cartilage), comparing to standard CS. The molar weight (Mw) of the CS samples, used as a qualitative biochemical parameter, was obtained by comparing their relative mobility on a polyacrylamide gel electrophoresis to standard CS. Gluchon, but not Glu, significantly reduced joint pain (P<0.05) compared to NT. There was an increase in CS content in the OA group (77.7 +/- 8.3 mu g/mg) compared to sham (53.5 +/- 11.2 mu g/mg) (P<0.05). The CS from OA samples had higher Mw (4:62 +/- 0:24 x 10(4) g/mol) compared to sham (4:18 +/- 0:19 x 10(4) g/mol) (P<0.05). Gluchon administration significantly reversed both the increases in CS content (54.4 +/- 12.1 mu g/mg) and Mw (4:18 +/- 0:2 x 104 g/mol) as compared to NT. Isolated Glu decreased CS content though not reaching statistical significance. Cartilage histology alterations were also significantly prevented by Gluchon administration. Gluchon provides clinical (analgesia) and structural benefits in the ACLT model. This is the first demonstration that biochemical alterations occurring in parallel to histological damage in OA are prevented by Gluchon administration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introdução: A correta avaliação das capacidades do idoso será fundamental na diminuição do risco de queda inerente ao envelhecimento. Os Smartphones são uma boa ferramenta para a avaliação das capacidades em idosos. Objetivo: Verificar se o smartphone é uma ferramenta de avaliação do ângulo de dorsiflexão ativa da tibiotársica (Dors. TT) e em diferentes parâmetros relacionados com a marcha. ; Métodos: Estudo transversal correlacional, com amostra composta por 27 indivíduos com mais de 60 anos. Procedeu-se à recolha de dados através de um sistema de análise cinemática em 3D com conexão a uma plataforma de forças e de uma aplicação para Smartphone (Fraunhofer®, Porto, Portugal), de forma a verificar a funcionalidade desta última. As variáveis medidas foram a Dors. TT; e todas a variáveis relacionadas com a marcha. Resultados: A dors. TT apresentou uma correlação forte positiva (rs=0,8; p<0,001) entre os dados dos dois instrumentos, assim como no balanço pélvico (rp=0,8; p<0,001), na velocidade na marcha (rp=0,7; p<0,001) e no nº de passos posteriores (rs=0,8; p<0,001). Observou-se uma correlação moderada positiva na duração do passo direito, na duração do passo, na duração da passada, na cadência, no comprimento do passo esq., no comprimento do passo e no deslocamento lateral da pélvis (rp=0,6; p≤0.008). Na percentagem da fase de apoio (%FA) (rs =-0.6; p= 0.007) e na medição da cadência lateral (rs =-0.4; p= 0.042) observou-se uma correlação moderada negativa e na cad. post. (rs=-0,7; p<0,001) uma correlação forte negativa. Conclusão: A aplicação para Smartphone parece ser uma ferramenta útil para avaliar corretamente o ângulo de dorsiflexão da tibiotársica, a contagem do número de passos no sentido posterior, o balanço pélvico e a velocidade. Contudo, necessita ser reajustada para as outras variáveis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In cataract surgery, the eye’s natural lens is removed because it has gone opaque and doesn’t allow clear vision any longer. To maintain the eye’s optical power, a new artificial lens must be inserted. Called Intraocular Lens (IOL), it needs to be modelled in order to have the correct refractive power to substitute the natural lens. Calculating the refractive power of this substitution lens requires precise anterior eye chamber measurements. An interferometry equipment, the AC Master from Zeiss Meditec, AG, was in use for half a year to perform these measurements. A Low Coherence Interferometry (LCI) measurement beam is aligned with the eye’s optical axis, for precise measurements of anterior eye chamber distances. The eye follows a fixation target in order to make the visual axis align with the optical axis. Performance problems occurred, however, at this step. Therefore, there was a necessity to develop a new procedure that ensures better alignment between the eye’s visual and optical axes, allowing a more user friendly and versatile procedure, and eventually automatizing the whole process. With this instrument, the alignment between the eye’s optical and visual axes is detected when Purkinje reflections I and III are overlapped, as the eye follows a fixation target. In this project, image analysis is used to detect these Purkinje reflections’ positions, eventually automatically detecting when they overlap. Automatic detection of the third Purkinje reflection of an eye following a fixation target is possible with some restrictions. Each pair of detected third Purkinje reflections is used in automatically calculating an acceptable starting position for the fixation target, required for precise measurements of anterior eye chamber distances.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To analyze the relationship between myocardial bridges and the anterior interventricular branch (anterior descending) of the left coronary artery. METHODS: The study was carried out with postmortem material, and methods of dissection and observation were used. We assessed the perimeter of the anterior interventricular branch of the left coronary artery using a pachymeter, calculated its proximal and distal diameters in relation to the myocardial bridge, and also its diameter under the myocardial bridge in 30 hearts. We also observed the position of the myocardial bridge in relation to the origin of the anterior interventricular branch. RESULTS: The diameters of the anterior interventricular branch were as follows: the mean proximal diameter was 2.76±0.76 mm; the mean diameter under the myocardial bridge was 2.08±0.54 mm; and the mean distal diameter was 1.98±0.59 mm. In 33.33% (10/30) of the cases, the diameter of the anterior interventricular branch under the myocardial bridge was lower than the diameter of the anterior interventricular branch distal to the myocardial bridge. In 3.33% (1/30) of the cases, an atherosclerotic plaque was found in the segment under the myocardial bridge. The myocardial bridge was located in the middle third of the anterior interventricular branch in 86.66% (26/30) of the cases. CONCLUSION: Myocardial bridges are more frequently found in the middle third of the anterior interventricular branch of the left coronary artery. The diameter of the anterior interventricular branch of the left coronary artery under the myocardial bridge may be smaller than after the bridge. Myocardial bridges may not provide protection against the formation of atherosclerotic plaque inside the anterior interventricular branch of the left coronary artery.