989 resultados para adaptation capacity
Resumo:
An adaptation of the standard battery of Woodcock-Johnson III Tests of Cognitive Abilities (WJ-III) for Brazilian children and youth was investigated. The sample was composed of 1094 students (54 percent girls), ages 7-17, living in Sao Paulo state (91 percent). Items from Brazilian school books as well as from the WJ-III Spanish version (Bateria-R) were added to comprehension-knowledge tests. Brazilian words were adapted to the auditory tests according to syllabic division and stressed syllables. Items were examined through IRT and age differences through analysis of variance. Results indicated the need to remove items from all WJ-III subtests with the exception of the visual learning test. Analysis of Variance indicated significant age differences (p <= 0.001) for all tests. Thus, the importance of a Brazilian adaptation for the WJ-III was confirmed.
Resumo:
Overcommitment of development capacity or development resource deficiencies are important problems in new product development (NPD). Existing approaches to development resource planning have largely neglected the issue of resource magnitude required for NPD. This research aims to fill the void by developing a simple higher-level aggregate model based on an intuitive idea: The number of new product families that a firm can effectively undertake is bound by the complexity of its products or systems and the total amount of resources allocated to NPD. This study examines three manufacturing companies to verify the proposed model. The empirical results confirm the study`s initial hypothesis: The more complex the product family, the smaller the number of product families that are launched per unit of revenue. Several suggestions and implications for managing NPD resources are discussed, such as how this study`s model can establish an upper limit for the capacity to develop and launch new product families.
Resumo:
The aim of the present work was to characterize the egg production of Loxopagurus loxochelis. A total of 71 ovigerous females were obtained, 28% of which were simultaneously incubating eggs at different developmental stages. This phenomenon can be the result of incomplete fertilization, or may represent a rapid gonadal cycle by this species in this area, which is, to our understanding, the best explanation of this phenomenon. Egg volume decreased 25.6% during the incubation period. The reproductive output based on dry and wet weight was 6.8 and 19.3%, respectively. Water was the prevailing component of the eggs, representing 86.0% of the total weight at initial stage, increasing to 95.1% at the final stage. Ash content increased at the same time as a decrease in the organic content occurred, indicating the consumption of yolk and absorption of salts from the water medium. In conclusion, we hypothesized that this population has the capacity to copulate and deposit another brood even before the release of the larvae from the previous one, intensifying the reproductive effort of these hermit crabs as a strategy of adaptation in a region considered the northern limit of the geographical distribution of this species.
Resumo:
Polybia scutellaris constructs huge nests characterized by numerous spinal projections on the surface. We investigated the thermal characteristics of P scutellaris nests in order to determine whether their nest temperature is homeothermically maintained and whether the spines play a role in the thermoregulation of the nests. In order to examine these hypotheses, we measured the nest temperature in a active nest and in an abandoned nest. The temperature in the active nest was almost stable at 27 degrees C, whereas that of the abandoned nest varied with changes in the ambient temperature, suggesting that nest temperature was maintained by the thermogenesis of colony individuals. In order to predict the thermal properties of the spines, a numerical simulation was employed. To construct a 3D-model of a P scutellaris nest, the nest architecture was simplified into an outer envelope and the surface spines, for both of which the initial temperature was set at 27 degrees C. The physical properties of the simulated nest were regarded to be those of wood since the nest of this species is constructed from plant materials. When the model was exposed to cool air (12 degrees C), the temperature was lower in the models with more spines. On the other hand, when the nest was heated (42 degrees C), the temperature increase was smaller in models with more spines. It is suggested that the spines act as a heat radiator, not as an insulator, against the changes in ambient temperature.
Resumo:
This paper seeks to understand how software systems and organisations co-evolve in practice and how order emerges in the overall environment. Using a metaphor of timetable as a commons, we analyse the introduction of a novel academic scheduling system to demonstrate how Complex Adaptive Systems theory provides insight into the adaptive behaviour of the various actors and how their action is both a response to and a driver of co-evolution within the engagement.
Resumo:
Background Pulmonary function tests (PFT), particularly spirometry and lung diffusing capacity for carbon monoxide (DL(CO)), have been considered useful methods for the detection of the progression of interstitial asbestos abnormalities as indicated by high-resolution computed tomography (HRCT). However, it is currently unknown which of these two tests correlates best with anatomical changes over time. Methods In this study, we contrasted longitudinal changes (3-9 years follow-up) in PFTs at rest and during exercise with interstitial abnormalities evaluated by HRCT in 63 ex-workers with mild-to-moderate asbestosis. Results At baseline, patients presented with low-grade asbestosis (Huuskonen classes I-II), and most PFT results were within the limits of normality. In the follow-up, most subjects had normal spirometry, static lung volumes and arterial blood gases. In contrast, frequency of DL(CO) abnormalities almost doubled (P < 0.05). Twenty-three (36.5%) subjects increased the interstitial marks on HRCT. These had significantly larger declines in DL(CO) compared to patients who remained stable (0.88 vs. 0.31 ml/min/mm Hg/year and 3.5 vs. 1.2%/year, respectively; P < 0.05). In contrast, no between-group differences were found for the other functional tests, including spirometry (P > 0.05). Conclusions These data demonstrate that the functional consequences of progression of HRCT abnormalities in mild-to-moderate asbestosis are better reflected by decrements in DL(CO) than by spirometric changes. These results might have important practical implications for medico-legal evaluation of this patient population. Am. J. Ind. Med. 54:185-193, 2011. (c) 2010 Wiley-Liss, Inc.
Resumo:
Background: A previous study associated CD34(+) levels with NYHA functional class in heart failure patients. The aim of this study was to correlate CD34(+) levels to exercise capacity, functional class, quality of life and norepinephrine in heart failure patients. Methods: Twenty three sedentary patients (52 +/- 7 years, 78% male) answered the Minnesota Living with Heart Failure Questionnaire and rested for 20 minutes before an investigator collect a blood sample. After this, patients performed a cardiopulmonary exercise test to determine the heart rate at anaerobic and ventilatory threshold and oxygen consumption at peak effort, at anaerobic and ventilatory threshold. One other blood sample was collected during the peak effort to investigate the norepinephrine and CD34(+) levels. Results: Rest percentage of CD34(+) did not show correlation with: left ventricle ejection fraction (r = 0.03, p = 0.888), peakVO(2) (r = 0.32, p = 0.13), VO(2) at anaerobic threshold (VO(2)AT) (r = 0.03, p = 0.86), VO(2) at ventilatory threshold (VO(2)VT) (r = 0.36, p = 0.08), NYHA functional class (r = -0.2, p = 0.35), quality of life (Minnesota) (r = -0.17, p = 0.42). CD34(+) did not show correlation, either, with: peak VO(2) (r = 0.38, p = 0.06), VO(2)AT (r = 0.09, p = 0.65), VO(2)VT (r = 0.43, p = 0.4), NYHA functional class (r = -0.13, p = 0.54), quality of life (r = 0.00, p = 0.99). Conclusions: CD34(+) levels did not correlate with exercise capacity, functional class, quality of life and norepinephrine. Percentage of CD34(+) levels did not increase during the cardiopulmonary exercise test in heart failure patients. (Cardiol J 2009; 16, 5: 426-431)
Resumo:
Endomyocardial fibrosis (EMF) is a restrictive cardiomyopathy manifested mainly by diastolic heart failure. It is recognized that diastole is an important determinant of exercise capacity. The purpose of this study was to determine whether resting echocardiographic parameters might predict oxygen consumption (VO(2p)) by ergoespirometry and the prognostic role of functional capacity in EMF patients. A total of 32 patients with biventricular EMF (29 women, 55.3 +/- 11.4 years) were studied by echocardiography and ergoespirometry. The relationship between the echocardiographic indexes and the percentage of predicted VO(2p) (%VO(2p)) was investigated by the `stepwise` linear regression analysis. The median VO(2p) was 11 +/- 3 mL/kg/min and the %VO(2p) was 53 +/- 9%. There was a correlation of %VO(2p) with an average of A` at four sites of the mitral annulus (A` peak, r = 0.471, P = 0.023), E`/A` of the inferior mitral annulus (r = -0.433, P = 0.044), and myocardial performance index (r = -0.352, P = 0.048). On multiple regression analysis, only A` peak was an independent predictor of %VO(2p) (%VO(2p)= 26.34 + 332.44 x A` peak). EMF patients with %VO(2p)< 53% had an increased mortality rate with a relative risk of 8.47. In EMF patients, diastolic function plays an important role in determining the limitations to exercise and %VO(2p) has a prognostic value.
Resumo:
Background and objective: Hyperinflation with a decrease in inspiratory capacity (IC) is a common presentation for both unstable and stable COPD patients. As CPAP can reduce inspiratory load, possibly secondary to a reduction in hyperinflation, this study examined whether CPAP would increase IC in stable COPD patients. Methods: Twenty-one stable COPD patients (nine emphysema, 12 chronic bronchitis) received a trial of CPAP for 5 min at 4, 7 and 11 cmH(2)O. Fast and slow VC (SVC) were measured before and after each CPAP trial. In patients in whom all three CPAP levels resulted in a decreased IC, an additional trial of CPAP at 2 cmH(2)O was conducted. For each patient, a `best CPAP` level was defined as the one associated with the greatest IC. This pressure was then applied for an additional 10 min followed by spirometry. Results: Following application of the `best CPAP`, the IC and SVC increased in 15 patients (nine emphysema, six chronic bronchitis). The mean change in IC was 159 mL (95% CI: 80-237 mL) and the mean change in SVC was 240 mL (95% CI: 97-386 mL). Among these patients, those with emphysema demonstrated a mean increase in IC of 216 mL (95% CI: 94-337 mL). Six patients (all with chronic bronchitis) did not demonstrate any improvement in IC. Conclusions: The best individualized CPAP can increase inspiratory capacity in patients with stable COPD, especially in those with emphysema.
Resumo:
is study examined the social adaptation of children with mild intellectual disability who were either (a) partially integrated into regular primary school classes, or (b) full-time in separate classes, All of the children were integrated in sport and play activities with the whole school. Consistent with previous research, children with intellectual disability were less socially accepted than were a matched group of control children. Children in partially integrated classes received more play nominations than those in separate classes, brit there was no greater acceptance as a best friend. On teachers' reports, disabled children had higher levels of inappropriate social behaviours, but there was no significant difference in appropriate behaviours. Self-assessments by integrated children were more negative than those by children in separate classes, and their peer-relationship satisfaction was lower. Ratings by disabled children of their satisfaction with peer relationships were associated with ratings of appropriate social skills by themselves and their teachers, and with self-ratings of negative behaviour. The study confirmed that partial integration can have negative consequences for children with an intellectual disability.
Resumo:
Severe obesity has been associated with adverse effects on physical capacity. In a prospective study, the aerobic capacity of severely obese patients was measured in order to observe the physiological response to weight loss from bariatric surgery. Sixty-five consecutive patients (40.4 +/- 8.4 years old; 93.8% female; body mass index = 49.4 +/- 5.4 kg/m(2)) were evaluated before bariatric surgery and then 6 and 12 months after surgery. Aerobic capacity was assessed with a scientific treadmill to measure maximal oxygen consumption (VO(2max)), heart rate, blood pressure, time on the treadmill, and distance walked (modified Bruce test). For the three observational periods, VO(2max) was 25.4 +/- 9.3, 29.8 +/- 8.1, and 36.7 +/- 8.3 ml/kg/min; time on the treadmill was 5.4 +/- 1.4, 6.4 +/- 1.6, and 8.8 +/- 1.0 min; and distance walked was 401.8 +/- 139.1, 513.4 +/- 159.9, and 690.5 +/- 76.2 m. For these variables, significant results (p = 0.0000) were observed for the two postoperative periods in relation to the preoperative period. Severely obese individuals increased their aerobic capacity after successful bariatric surgery. The data also suggests that a positive and progressive relationship between weight loss and improvement in fitness as a moderate loss of weight 6 months after surgery already showed some benefit and an additional reduction in weight was associated with a better performance in the aerobic capacity tests at the 12-month follow-up.
Resumo:
Background: The 6-minute walk test (6MWT) is a well-known instrument for assessing the functional capacity of a variety of groups, including the obese. It is a simple, low-cost and easily applied method to objectively assess the level of exercise capacity. The aim of the present study was to study the functional capacity of a severely obese population before and after bariatric surgery. Methods: A total of 51 patients were studied. Of the 51 patients, 86.2% were women, and the mean age was 40.9 +/- 9.2 years. All 51 patients were evaluated preoperatively and 49 were evaluated 7-12 months postoperatively. The initial body mass index was 51.1 +/- 9.2 kg/m(2), and the final body mass index was 28.2 +/- 8.1 kg/m(2). All patients underwent Roux-en-Y gastric bypass. The 6MWT was performed in a hospital corridor, with patients attempting to cover as much distance as they could, walking back and forth for as long as possible within 6 minutes at their regular pace. The total distance, Borg Scale of perceived exhaustion, modified Borg dyspnea scale for shortness of breath, and physical complaints at the end of the test were recorded. In addition, the heart rate and respiratory frequency were assessed before and after the test. Results: The tolerance was good, and no injuries occurred at either evaluation. The patients` mean distance for the 6MWT was 381.9 +/- 49.3 m before surgery and 467.8 +/- 40.3 m after surgery (p < .0001). Similar results were observed for the other parameters assessed. Conclusion: The 6MWT provided useful information about the functional status of the obese patients undergoing bariatric surgery. A simple, safe, and powerful method to assess functional capacity of severely obese patients, the 6MWT is an objective test that might replace the conventional treadmill test for these types of patients. (Surg Obes Relat Dis 2009;5:540-543.) (C) 2009 American Society for Metabolic and Bariatric Surgery. All rights reserved.
Resumo:
The objective of this prospective study was to perform a cross-cultural adaptation of the Functional Assessment Measure (FAM) into Brazilian Portuguese, and to assess the test-retest reliability. The instrument was translated, back-translated, pretested, and reviewed by a committee. The Brazilian version was assessed in 61 brain-injury patients. Intrarater and interrater reliability was verified by a test-retest procedure (intraclass correlation). Intrarater reliability was moderate-to-excellent; interrater reliability was moderate-to-excellent, with the exception of one item. The Brazilian version of the FAM has acceptable test-retest reliability. Results suggest the use of the Brazilian version of the FAM in the Brazilian population, for disability evaluation and outcome assessment. Further research is required to evaluate the psychometric properties of the scale. International Journal of Rehabilitation Research 34:89-91 (C) 2011 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.
Resumo:
Background:The Nasal Obstruction Symptom Evaluation (NOSE) instrument is a disease-specific questionnaire for assessing the outcome of an intervention in nasal obstruction in trials. This instrument is only available in the English language and cross-culturally valid questionnaires are very important for all research, including nasal obstruction. The aim of the current study was to reproduce the cross-cultural adaptation process for the NOSE questionnaire in the Portuguese language (NOSE-p). Methodology: Cross-cultural adaptation and validation of the instrument were divided into two stages. Stage I involved four bilingual professionals, an expert committee and the author of the original instrument. In Stage 2, the NOSE-p was tested on 33 patients undergoing septoplasty for internal consistency, test-retest reliability, construct validity. discriminant validity, criterion validity, and response sensitivity. Results: The cross-cultural adaptation process was completed and the NOSE-p was demonstrated to be a valid instrument with satisfactory construct validity. It showed an adequate internal consistency reliability and adequate test-retest reliability. It could discriminate between patients with and without nasal obstruction and it has a high response sensitivity to change. Conclusions: The cross-cultural adaptation and validation process demonstrated to be valid and the NOSE-p proved to be applicable in Brazil.