912 resultados para ZigBee device
Resumo:
OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.
Resumo:
Summary
Resumo:
INTRODUCTION: Intraosseous access is increasingly recognised as an effective alternative vascular access to peripheral venous access. We aimed to prospectively study the patients receiving prehospital intraosseous access with the EZ-IO(®), and to compare our results with those of the available literature. METHODS: Every patient who required an intraosseous access with the EZ-IO from January 1st, 2009 to December 31st, 2011 was included. The main data collected were: age, sex, indication for intraosseous access, localisation of insertion, success rate, drugs and fluids administered, and complications. All published studies concerning the EZ-IO device were systematically searched and reviewed for comparison. RESULTS: Fifty-eight patients representing 60 EZ-IO procedures were included. Mean age was 47 years (range 0.5-91), and the success rate was 90%. The main indications were cardiorespiratory arrest (74%), major trauma (12%), and shock (5%). The anterior tibia was the main route. The main drugs administered were adrenaline (epinephrine), atropine and amiodarone. No complications were reported. We identified 30 heterogeneous studies representing 1603 EZ-IO insertions. The patients' characteristics and success rate were similar to our study. Complications were reported in 13 cases (1.3%). CONCLUSION: The EZ-IO provides an effective way to achieve vascular access in the pre-hospital setting. Our results were similar to the cumulative results of all studies involving the use of the EZ-IO, and that can be used for comparison for further studies.
Resumo:
We have designed and built an experimental device, which we called a "thermoelectric bridge." Its primary purpose is simultaneous measurement of the relative Peltier and Seebeck coefficients. The systematic errors for both coefficients are equal with this device and manipulation is not necessary between the measurement of one coefficient and the other. Thus, this device is especially suitable for verifying their linear relation postulated by Lord Kelvin. Also, simultaneous measurement of thermal conductivity is described in the text. A sample is made up of the couple nickel¿platinum, taking measurements in the range of ¿20¿60°C and establishing the dependence of each coefficient with temperature, with nearly equal random errors ±0.2%, and systematic errors estimated at ¿0.5%. The aforementioned Kelvin relation is verified in this range from these results, proving that the behavioral deviations are ¿0.3% contained in the uncertainty ±0.5% caused by the propagation of errors
Resumo:
As the list of states adopting the HWTD continues to grow, there is a need to evaluate how results are utilized. AASHTO T 324 does not standardize the analysis and reporting of test results. Furthermore, processing and reporting of the results among manufacturers is not uniform. This is partly due to the variation among agency reporting requirements. Some include only the midpoint rut depth, while others include the average across the entire length of the wheel track. To eliminate bias in reporting, statistical analysis was performed on over 150 test runs on gyratory specimens. Measurement location was found to be a source of significant variation in the HWTD. This is likely due to the nonuniform wheel speed across the specimen, geometry of the specimen, and air void profile. Eliminating this source of bias when reporting results is feasible though is dependent upon the average rut depth at the final pass. When reporting rut depth at the final pass, it is suggested for poor performing samples to average measurement locations near the interface of the adjoining gyratory specimens. This is necessary due to the wheel lipping on the mold. For all other samples it is reasonable to only eliminate the 3 locations furthest from the gear house. For multi‐wheel units, wheel side was also found to be significant for poor and good performing samples. After eliminating the suggested measurements from the analysis, the wheel was no longer a significant source of variation.
Resumo:
Objective: To determine the variation in prevalence of temporomandibular disorders (TMD), other side effects, and technical complications during 5 years of sleep apnea treatment with a mandibular advancement device. Materials and Methods: Forty patients diagnosed with obstructive sleep apnea received an adjustable appliance at 70% of the maximum protrusion. The protrusion was then progressively increased. TMD (diagnosed according to the Research Diagnostic Criteria for TMD), overjet, overbite, occlusal contacts, subjective side effects, and technical complications were recorded before and a mean of 14, 21, and 58 months after treatment and analyzed by the Wilcoxon test (P Less-than .05). Results: Fifteen patients still used the oral appliance at the 5-year follow-up, and no significant variation in TMD prevalence was observed. Subjective side effects were common, and a significant reduction was found in overjet, overbite, and in the number of occlusal contacts. Furthermore, the patients made a mean of 2.5 unscheduled dental visits per year and a mean of 0.8 appliance repairs/relines per year by a dental technician. The most frequent unscheduled visits were needed during the first year and were a result of acrylic breakage on the lateral telescopic attachment, poor retention, and other adjustments to improve comfort. Conclusions: Five-year oral appliance treatment does not affect TMD prevalence but is associated with permanent occlusal changes in most sleep apnea patients during the first 2 years. Patients seek several unscheduled visits, mainly because of technical complications.
Resumo:
The Iowa Department of Transportation research project HR-1013 is the evaluation of a prototype continuous monitoring nuclear density unit. The Unit, the Consolidation Monitoring Device (CMD), mounts on the rear of a slip-form paver and measures the density of the concrete while still in the plastic state. The evaluation performed determined the usefulness, accuracy, precision and reproducibility of the unit. The CMD was calibrated and tested in the laboratory for one week before field evaluation. The field evaluation consisted of monitoring at least 5 miles of paving and then correlating the CMD data with two conventional density methods. The two supplemental methods were density measurement with a Troxler nuclear gauge and densities obtained from core samples.
Resumo:
OBJECTIVE: The major source of hemolysis during cardiopulmonary bypass remains the cardiotomy suction and is primarily due to the interaction between air and blood. The Smart suction system involves an automatically controlled aspiration designed to avoid the mixture of blood with air. This study was set-up to compare this recently designed suction system to a Cell Saver system in order to investigate their effects on blood elements during prolonged intrathoracic aspiration. METHODS: In a calf model (n=10; mean weight, 69.3+/-4.5 kg), a standardized hole was created in the right atrium allowing a blood loss of 100 ml/min, with a suction cannula placed into the chest cavity into a fixed position during 6 h. The blood was continuously aspirated either with the Smart suction system (five animals) or the Cell Saver system (five animals). Blood samples were taken hourly for blood cell counts and biochemistry. RESULTS: In the Smart suction group, red cell count, plasma protein and free hemoglobin levels remained stable, while platelet count exhibited a significant drop from the fifth hour onwards (prebypass: 683+/-201*10(9)/l, 5 h: 280+/-142*10(9)/l, P=0.046). In the Cell Saver group, there was a significant drop of the red cell count from the third hour onwards (prebypass: 8.6+/-0.9*10(12)/l, 6 h: 6.3+/-0.4*10(12)/l, P=0.02), of the platelet count from the first hour onwards (prebypass: 630+/-97*10(9)/l, 1 h: 224+/-75*10(9)/l, P<0.01), and of the plasma protein level from the first hour onwards (prebypass: 61.7+/-0.6 g/l, 1 h: 29.3+/-9.1 g/l, P<0.01). CONCLUSIONS: In this experimental set-up, the Smart suction system avoids damage to red cells and affects platelet count less than the Cell Saver system which induces important blood cell destruction, as any suction device mixing air and blood, as well as severe hypoproteinemia with its metabolic, clotting and hemodynamic consequences.
Resumo:
BACKGROUND: Gastric banding still represents one of the most widely used bariatric procedures. It provides acceptable weight loss in many patients, but has frequent long-term complications. Because different types of bands may lead to different results, we designed a randomized study to compare the Lapband® with the SAGB®. We hereby report on the long-term results. METHODS: Between December 1998 and June 2002, 180 morbidly obese patients were randomized between Lapband® or SAGB®. Weight loss, long-term morbidity, and need for reoperation were evaluated. RESULTS: Long-term weight loss did not differ between the two bands. Patients who maintained their band had an acceptable long-term weight loss of between 50 and 60 % EBMIL. In both groups, about half the patients developed long-term complications, with about 50 % requiring major redo surgery. There was no difference in the overall rates of long-term complications or failures between the two groups, but patients who had a Lapband® were significantly more prone to develop band slippage/pouch dilatation (13.3 versus 0 %, p < 0,001). CONCLUSIONS: Although in the absence of complication, gastric banding leads to acceptable weight loss; the long-term complication and major reoperation rates are very high independently from the type of band used or on the operative technique. Gastric banding leads to relatively poor overall long-term results and therefore should not be considered the procedure of choice for the treatment of morbid obesity. Patients should be informed of the limited overall weight loss and the very high complication rates.
Resumo:
Accurate diagnosis of orthopedic device-associated infections can be challenging. Culture of tissue biopsy specimens is often considered the gold standard; however, there is currently no consensus on the ideal incubation time for specimens. The aim of our study was to assess the yield of a 14-day incubation protocol for tissue biopsy specimens from revision surgery (joint replacements and internal fixation devices) in a general orthopedic and trauma surgery setting. Medical records were reviewed retrospectively in order to identify cases of infection according to predefined diagnostic criteria. From August 2009 to March 2012, 499 tissue biopsy specimens were sampled from 117 cases. In 70 cases (59.8%), at least one sample showed microbiological growth. Among them, 58 cases (82.9%) were considered infections and 12 cases (17.1%) were classified as contaminations. The median time to positivity in the cases of infection was 1 day (range, 1 to 10 days), compared to 6 days (range, 1 to 11 days) in the cases of contamination (P < 0.001). Fifty-six (96.6%) of the infection cases were diagnosed within 7 days of incubation. In conclusion, the results of our study show that the incubation of tissue biopsy specimens beyond 7 days is not productive in a general orthopedic and trauma surgery setting. Prolonged 14-day incubation might be of interest in particular situations, however, in which the prevalence of slow-growing microorganisms and anaerobes is higher.
Resumo:
With inflation, there is no longer a completely adequate budget for highway construction and maintenance. Restricted budgets have generated development and implementation of pavement management programs. A need for management guidelines generated National Cooperative Highway Research Program Synthesis of Highway Practice 84, "Evaluation Criteria and Priority Setting for State Highway Programs". Traffic volumes and present conditions are two major factors in determining the priority of a proposed highway improvement. The Iowa DOT, Highway Division, Office of Materials has been conducting pavement condition inventory surveys on a three-year frequency since 1969 as input for pavement management. Development of substantial wheel rutting on paved roadways results in a potential hazard to highway safety. During periods of rain, these water-filled ruts may cause hydroplaning and loss of vehicle control. It is, therefore, imparitive that Iowa roadways be continually monitored for rut depths and further that this data be used in a pavement management program to determine priorities for rehabilitation or resurfacing.
Resumo:
The objective was to evaluate the usefulness, accuracy, precision, and reproducibility of the second generation CMD for PC concrete under production conditions.
Resumo:
In jointed portland cement concrete pavements, dowel bars are typically used to transfer loads between adjacent slabs. A common practice is for designers to place dowel bars at a certain, consistent spacing such that a sufficient number of dowels are available to effectively transfer anticipated loads. In many cases, however, the standards developed today for new highway construction simply do not reflect the design needs of low traffic volume, rural roads. The objective of this research was to evaluate the impact of the number of dowel bars and dowel location on joint performance and ultimately on pavement performance. For this research, test sections were designed, constructed, and tested in actual field service pavement. Test sections were developed to include areas with load transfer assemblies having three and four dowels in the outer wheel path only, areas with no joint reinforcement whatsoever, and full lane dowel basket assemblies as the control. Two adjacent paving projects provided both rural and urban settings and differing base materials. This report documents the approach to implementing the study and provides discussion and suggestions based on the results of the research. The research results indicate that the use of single three or four dowel basket assemblies in the outer wheel path is acceptable for use in low truck volume roads. In the case of roadways with relatively stiff bases such as asphalt treated or stabilized bases, the use of the three dowel bar pattern in the outside wheel path is expected to provide adequate performance over the design life of the pavement. In the case of untreated or granular bases, the results indicate that the use of the three or four dowel bar basket in both wheel paths provides the best long-term solution to load transfer and faulting measurements.