948 resultados para Voltage source converter


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Research for better performance materials in biomedical applications are constants. Thus recent studies aimed at the development of new techniques for modification of surfaces. The low pressure plasma has been highlighted for its versatility and for being environmentally friendly, achieving good results in the modification of physic chemical properties of materials. However, it is requires an expensive vacuum system and cannot able to generate superficial changes in specific regions. Furthermore, it is limits their use in polymeric materials and sensitive terms due to high process temperatures. Therefore, new techniques capable of generating cold plasma at atmospheric pressure (APPJ) were created. In order to perform surface treatments on biomaterials in specific regions was built a prototype capable of generating a cold plasma jet. The prototype plasma generator consists of a high voltage source, a support arm, sample port and a nozzle through which the ionized argon. The device was formed to a dielectric tube and two electrodes. This work was varied some parameters such as position between electrodes, voltage and electrical frequency to verify the behavior of glow discharges. The disc of titanium was polished and there was a surface modification. The power consumed, length, intensity and surface modifications of titanium were analyzed. The energy consumed during the discharges was observed by the Lissajous figure method. To check the length of the jets was realized with Image Pro Plus software. The modifications of the titanium surfaces were observed by optical microscopy (OM ) and atomic force microscopy (AFM ). The study showed that variations of the parameters such as voltage, frequency and geometric position between the electrodes influence the formation of the plasma jet. It was concluded that the plasma jet near room temperature and atmospheric pressure was able to cause modifications in titanium surface

Relevância:

80.00% 80.00%

Publicador:

Resumo:

E. coli,em caldo glicosado,foi submetida a campo eletromagnético de intensidade 5G, gerado por fonte de tensão alternada de 60 Hz . Os crescimento e consumo de glicose foram avaliados através do teste não-paramétrico de Mann-Whitney para comparação de dois grupos. Após 8 h de exposição encontraram-se menor valor da glicose residual e maior turbidez nos tubos expostos ao campo evidenciando efeito positivo deste. A causa deste efeito no consumo da glicose pode ser pela estimulação de sistema de transporte de glicose, como a Difusão Facilitada ou por um tipo de fenômeno chamado ressonância ciclotrônica. O aumento do crescimento pode ser pelo encurtamento da lag phase e estimulação da log phase.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The behaviors of an arc-shaped stator induction machine (the sector-motor) and a disc-secondary linear induction motor are analyzed in this work for different values of the frequency. Variable frequency is produced by a voltage source controlled-current inverter which keeps constant the r.m.s. value of the phase current, also assuring a sinusoidal waveform. For the simulations of the machine developed thrust, an equivalent circuit is used. It is obtained through the application of the one-dimensional theory to the modeling. The circuit parameters take into account the end effects, always present is these kind of machines. The phase current waveforms are analyzed for their harmonic contents. Experimental measurements were carried out in laboratory and are presented with the simulations, for comparison.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEB

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper presents a comparative study based on literature and examples in the literature, the two main technologies for the transmission of electricity at high voltage: alternate current transmission and direct current transmission. Inside the direct current transmission will be shown two technologies currently employed, transmission by current source and transmission by voltage source, contributing to a better understanding of them. The ultimate goal is to provide a text for consultation to identify key characteristics that influence the choice of future transmission lines

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work proposes the development of an Adaptive Neuro-fuzzy Inference System (ANFIS) estimator applied to speed control in a three-phase induction motor sensorless drive. Usually, ANFIS is used to replace the traditional PI controller in induction motor drives. The evaluation of the estimation capability of the ANFIS in a sensorless drive is one of the contributions of this work. The ANFIS speed estimator is validated in a magnetizing flux oriented control scheme, consisting in one more contribution. As an open-loop estimator, it is applied to moderate performance drives and it is not the proposal of this work to solve the low and zero speed estimation problems. Simulations to evaluate the performance of the estimator considering the vector drive system were done from the Matlab/Simulink(R) software. To determine the benefits of the proposed model, a practical system was implemented using a voltage source inverter (VSI) to drive the motor and the vector control including the ANFIS estimator, which is carried out by the Real Time Toolbox from Matlab/Simulink(R) software and a data acquisition card from National Instruments.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Research work carried out in focusing a novel multiphase-multilevel ac motor drive system much suitable for low-voltage high-current power applications. In specific, six-phase asymmetrical induction motor with open-end stator winding configuration, fed from four standard two-level three-phase voltage source inverters (VSIs). Proposed synchronous reference frame control algorithm shares the total dc source power among the 4 VSIs in each switching cycle with three degree of freedom. Precisely, first degree of freedom concerns with the current sharing between two three-phase stator windings. Based on modified multilevel space vector pulse width modulation shares the voltage between each single VSIs of two three-phase stator windings with second and third degree of freedom, having proper multilevel output waveforms. Complete model of whole ac motor drive based on three-phase space vector decomposition approach was developed in PLECS - numerical simulation software working in MATLAB environment. Proposed synchronous reference control algorithm was framed in MATLAB with modified multilevel space vector pulse width modulator. The effectiveness of the entire ac motor drives system was tested. Simulation results are given in detail to show symmetrical and asymmetrical, power sharing conditions. Furthermore, the three degree of freedom are exploited to investigate fault tolerant capabilities in post-fault conditions. Complete set of simulation results are provided when one, two and three VSIs are faulty. Hardware prototype model of quad-inverter was implemented with two passive three-phase open-winding loads using two TMS320F2812 DSP controllers. Developed McBSP (multi-channel buffered serial port) communication algorithm able to control the four VSIs for PWM communication and synchronization. Open-loop control scheme based on inverse three-phase decomposition approach was developed to control entire quad-inverter configuration and tested with balanced and unbalanced operating conditions with simplified PWM techniques. Both simulation and experimental results are always in good agreement with theoretical developments.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper fault detection and isolation (FDI) schemes are applied in the context of the surveillance of emerging faults in an electrical circuit. The FDI problem is studied on a noisy nonlinear circuit, where both abrupt and incipient faults in the voltage source are considered. A rigorous analysis of fault detectability precedes the application of the fault detection (FD) scheme; then, the fault isolation (FI) phase is accomplished with two alternative FI approaches, proposed as new extensions of that FD approach. Numerical simulations illustrate the applicability of the mentioned schemes.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The interest in LED lighting has been growing recently due to the high efficacy, lifelime and ruggedness that this technology offers. However the key element to guarantee those parameters with these new electronic devices is to keep under control the working temperature of the semiconductor crystal. This paper propases a LED lamp design that fulfils the requ irements of a PV lighting systems, whose main quality criteria is reliability. It uses directly as a power supply a non·stabilized constant voltage source, as batteries. An electronic control architecture is used to regulate the current applied to the LEO matri)( according to their temperature and the voltage output value of the batteries with two pulse modulation signals (PWM) signals. The first one connects and disconnects the LEOs to the power supply and the second one connects and disconnects several emitters to the electric circuit changing its overall impedance. A prototype of the LEO lamp has been implemented and tested at different temperaturas and battery voltages.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tecnologias HVDC que utilizam conversores do tipo fonte de tensão, o VSC-HVDC, ainda não são completamente difundidas e aplicadas no Brasil, em contraste com outros países que começaram a estudar e empregar este tipo de transmissão. Comparado com o HVDC tradicional, o VSC-HVDC é uma tecnologia de transmissão mais eficiente e pode superar deficiências encontradas na transmissão em corrente contínua convencional. O VSC-HVDC pode ser utilizado de maneira mais eficiente nas novas redes de energia, para alimentar ilhas, integração de geração eólica, renovação das linhas em centros urbanos, aplicações multiterminais e conexão com sistemas fracos. Por se tratar de uma tecnologia recente, o VSC-HVDC ainda não é amplamente adotado e uma das principais limitações da utilização destes sistemas é a sua fragilidade diante faltas na linha de corrente contínua. Neste contexto, limitadores de corrente de falta (LCF) podem ser utilizados para minimizar o impacto das faltas. A ação dos limitadores é benéfica ao sistema durante condições de falta, contudo, ainda assim é necessária a atuação do sistema de proteção para extinguir a condição faltosa. Portanto, este trabalho visa propor e avaliar um novo esquema de proteção que opere de maneira seletiva e confiável para sistemas VSC-HVDC na presença de LCF baseados em materiais supercondutores ou LCF indutivos. Para tanto, foram implementadas quatro funções de proteção tradicionais das linhas em CC, a saber: direcional de corrente, diferencial, sobrecorrente com restrição de tensão e ondas viajantes, e ainda, foi proposta uma nova função de proteção, a de condutância, a qual apresentou o menor tempo de identificação de falta, considerando as faltas mais severas. Adicionalmente, foi avaliado o comportamento destas funções quando o sistema apresenta os LCF em série com a linha. Foi demonstrado que é possível extrair os benefícios dos LCF sem deteriorar a qualidade dos resultados das funções de proteção, o que aumenta a segurança e confiabilidade dos sistemas VSC-HVDC, uma vez que os impactos das faltas são minimizados e as mesmas são identificadas em um curto intervalo de tempo.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work has concentrated on the testing of induction machines to determine their temperature rise at full-load without mechanically coupling to a load machine. The achievements of this work are outlined as follows. 1. Four distinct categories of mixed-frequency test using an inverter have been identified by the author. The simulation results of these tests as well as the conventional 2-supply test have been analysed in detail. 2. Experimental work on mixed-frequency tests has been done on a small (4 kW) squirrel cage induction machine using a voltage source PWM inverter. Two out of the four categories of test suggested have been tested and the temperature rise results were found to be similar to the results of a direct loading test. Further, one of the categories of test proposed has been performed on a 3.3 kW slip-ring induction machine for the conformation of the rotor values. 3. A low current supply mixed-frequency test-rig has been proposed. For this purpose, a resonant bank was connected to the DC link of the inverter in order to maintain the exchange of power between the test machine and the resonant bank instead of between the main supply and the test machine. The resonant bank was then replaced with a special electro-mechanical energy storage unit. The current of the main power supply was then reduced in amplitude. 4. A variable inertia test for full load temperature rise testing of induction machines has been introduced. This test is purely mechanical in nature and does not require any electrical connection of the test machine to any other machine. It has the advantage of drawing very little net power from the supply.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The application of high-power voltage-source converters (VSCs) to multiterminal dc networks is attracting research interest. The development of VSC-based dc networks is constrained by the lack of operational experience, the immaturity of appropriate protective devices, and the lack of appropriate fault analysis techniques. VSCs are vulnerable to dc-cable short-circuit and ground faults due to the high discharge current from the dc-link capacitance. However, faults occurring along the interconnecting dc cables are most likely to threaten system operation. In this paper, cable faults in VSC-based dc networks are analyzed in detail with the identification and definition of the most serious stages of the fault that need to be avoided. A fault location method is proposed because this is a prerequisite for an effective design of a fault protection scheme. It is demonstrated that it is relatively easy to evaluate the distance to a short-circuit fault using voltage reference comparison. For the more difficult challenge of locating ground faults, a method of estimating both the ground resistance and the distance to the fault is proposed by analyzing the initial stage of the fault transient. Analysis of the proposed method is provided and is based on simulation results, with a range of fault resistances, distances, and operational conditions considered.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This chapter discusses network protection of high-voltage direct current (HVDC) transmission systems for large-scale offshore wind farms where the HVDC system utilizes voltage-source converters. The multi-terminal HVDC network topology and protection allocation and configuration are discussed with DC circuit breaker and protection relay configurations studied for different fault conditions. A detailed protection scheme is designed with a solution that does not require relay communication. Advanced understanding of protection system design and operation is necessary for reliable and safe operation of the meshed HVDC system under fault conditions. Meshed-HVDC systems are important as they will be used to interconnect large-scale offshore wind generation projects. Offshore wind generation is growing rapidly and offers a means of securing energy supply and addressing emissions targets whilst minimising community impacts. There are ambitious plans concerning such projects in Europe and in the Asia-Pacific region which will all require a reliable yet economic system to generate, collect, and transmit electrical power from renewable resources. Collective offshore wind farms are efficient and have potential as a significant low-carbon energy source. However, this requires a reliable collection and transmission system. Offshore wind power generation is a relatively new area and lacks systematic analysis of faults and associated operational experience to enhance further development. Appropriate fault protection schemes are required and this chapter highlights the process of developing and assessing such schemes. The chapter illustrates the basic meshed topology, identifies the need for distance evaluation, and appropriate cable models, then details the design and operation of the protection scheme with simulation results used to illustrate operation. © Springer Science+Business Media Singapore 2014.