195 resultados para Vest


Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES This study prospectively evaluated the role of a novel 3-dimensional, noninvasive, beat-by-beat mapping system, Electrocardiographic Mapping (ECM), in facilitating the diagnosis of atrial tachycardias (AT). BACKGROUND Conventional 12-lead electrocardiogram, a widely used noninvasive tool in clinical arrhythmia practice, has diagnostic limitations. METHODS Various AT (de novo and post-atrial fibrillation ablation) were mapped using ECM followed by standard-of-care electrophysiological mapping and ablation in 52 patients. The ECM consisted of recording body surface electrograms from a 252-electrode-vest placed on the torso combined with computed tomography-scan-based biatrial anatomy (CardioInsight Inc., Cleveland, Ohio). We evaluated the feasibility of this system in defining the mechanism of AT-macro-re-entrant (perimitral, cavotricuspid isthmus-dependent, and roof-dependent circuits) versus centrifugal (focal-source) activation-and the location of arrhythmia in centrifugal AT. The accuracy of the noninvasive diagnosis and detection of ablation targets was evaluated vis-à-vis subsequent invasive mapping and successful ablation. RESULTS Comparison between ECM and electrophysiological diagnosis could be accomplished in 48 patients (48 AT) but was not possible in 4 patients where the AT mechanism changed to another AT (n = 1), atrial fibrillation (n = 1), or sinus rhythm (n = 2) during the electrophysiological procedure. ECM correctly diagnosed AT mechanisms in 44 of 48 (92%) AT: macro-re-entry in 23 of 27; and focal-onset with centrifugal activation in 21 of 21. The region of interest for focal AT perfectly matched in 21 of 21 (100%) AT. The 2:1 ventricular conduction and low-amplitude P waves challenged the diagnosis of 4 of 27 macro-re-entrant (perimitral) AT that can be overcome by injecting atrioventricular node blockers and signal averaging, respectively. CONCLUSIONS This prospective multicenter series shows a high success rate of ECM in accurately diagnosing the mechanism of AT and the location of focal arrhythmia. Intraprocedural use of the system and its application to atrial fibrillation mapping is under way.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Body weight (BW) and blood pressure (BP) have a close relationship, which has been accounted for by hormonal changes. No previous study has evaluated the effect of wearing an external weight vest on BP to determine whether there is a simple mechanism between BW and BP. Seventeen healthy volunteers underwent weight reduction (WR) through caloric restriction. Before and after WR, BW, body fat percentage and BP at rest and during exercise were measured. Before and after WR, exercise testing was performed twice with the random allocation of a weight vest (10 kg) during one of the tests. Linear regression was used to detect independent associations between BP and the weight vest, BW and body fat percentage. BW decreased from 89.4 ± 15.4 kg to 79.1 ± 14.0 kg following WR (P<0.001). WR led to significant decreases in BP at rest (from 130.0/85.9 mm Hg to 112.5/77.8 mm Hg, P<0.001 for systolic and diastolic BPs) and during exercise. The weight vest significantly increased BP at rest (to 136.1/90.7 mm Hg before and 125.8/84.6 mm Hg after WR) and during exercise. Linear regression analysis identified an independent association between the weight vest and BP (P=0.006 for systolic BP and P=0.009 for diastolic BP at rest). This study demonstrates that wearing an external weight vest has immediate effects on BP at rest and during exercise independent of BW or body fat. More research is needed to understand the physiological mechanisms between weight and BP.