947 resultados para Uniaxial bianisotropic, Transverse transmission line method
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Pós-graduação em Engenharia Elétrica - FEIS
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
It is important to ensure smoothly operation of a transmission line, sending energy to the consumption centers with minimal interruptions and safer. With this necessity, the fault location techniques have grown, in order to mitigate the impact of the fault and its correction can be more quickly and accurately. This paper presents a comparison between two different techniques of fault location, the fault location by impedance method, which uses the line parameters, the impedance per distance, voltage and current signals, and the other is the traveling wave method, which uses only a very fast analysis of time, synchronization and length between the line ends, do not using voltage and current values, but the temporal perception of the fault. Using travelling waves fault detection makes the previous knowledge of line parameters obsolete, which helps a lot network technicians and engineers with a quick and easy analysis. The methods are simulated in ATP Draw software, so both algorithms can be evaluated for their effectively and accuracy
Resumo:
It is important to ensure smoothly operation of a transmission line, sending energy to the consumption centers with minimal interruptions and safer. With this necessity, the fault location techniques have grown, in order to mitigate the impact of the fault and its correction can be more quickly and accurately. This paper presents a comparison between two different techniques of fault location, the fault location by impedance method, which uses the line parameters, the impedance per distance, voltage and current signals, and the other is the traveling wave method, which uses only a very fast analysis of time, synchronization and length between the line ends, do not using voltage and current values, but the temporal perception of the fault. Using travelling waves fault detection makes the previous knowledge of line parameters obsolete, which helps a lot network technicians and engineers with a quick and easy analysis. The methods are simulated in ATP Draw software, so both algorithms can be evaluated for their effectively and accuracy
Resumo:
This paper presents an analysis of the impact of the lightning overvoltages on the operational performance of the energized shield wire line technology (SWL) implemented in two locations of the State of Rondonia, Brazil. The analysis covers the periods of 1996 to 2000 (SWL Jaru) and 1997 to 2002 (SWL Itapua do Oeste), and shows that lightning is responsible for most of the system outages. The paper describes the satisfactory results achieved with the system, showing that the isolation and energization of the shield wires does not deteriorate the lightning performance of the 230 kV transmission lines. Comparisons between the performances of the SWL technology, conventional 34.5 kV lines, and thermal power plants in operation in the same region are also presented. The results demonstrate the technical and economical viability of the SWL technology and show that its application can lead to a postponement of investments.
Resumo:
The need for increasing the loading capacity of transmission lines in a traditional way, by replacing or reinforcement of the structures and foundations on routes crossing areas considered of permanent environmental preservation, may require additional works that alter the environment. The present rigorous environmental legislation turns these changes and substitution unfeasible. One way to increase the capacity of these lines is the use of new conductor technology. The aim of this paper is to discuss the needs for upgrading a transmission line and minimize or eliminate the damage to the environment by using special conductors. Because the aluminum conductor composite reinforced technology is relatively new and considering the lack of information related to its effective performance in practical system, there is a need to verify the behavior of these conductors through monitoring procedures.
Resumo:
So far, the majority of reports on on-line measurement considered soil properties with direct spectral responses in near infrared spectroscopy (NIRS). This work reports on the results of on-line measurement of soil properties with indirect spectral responses, e.g. pH, cation exchange capacity (CEC), exchangeable calcium (Caex) and exchangeable magnesium (Mgex) in one field in Bedfordshire in the UK. The on-line sensor consisted of a subsoiler coupled with an AgroSpec mobile, fibre type, visible and near infrared (vis–NIR) spectrophotometer (tec5 Technology for Spectroscopy, Germany), with a measurement range 305–2200 nm to acquire soil spectra in diffuse reflectance mode. General calibration models for the studied soil properties were developed with a partial least squares regression (PLSR) with one-leave-out cross validation, using spectra measured under non-mobile laboratory conditions of 160 soil samples collected from different fields in four farms in Europe, namely, Czech Republic, Denmark, Netherland and UK. A group of 25 samples independent from the calibration set was used as independent validation set. Higher accuracy was obtained for laboratory scanning as compared to on-line scanning of the 25 independent samples. The prediction accuracy for the laboratory and on-line measurements was classified as excellent/very good for pH (RPD = 2.69 and 2.14 and r2 = 0.86 and 0.78, respectively), and moderately good for CEC (RPD = 1.77 and 1.61 and r2 = 0.68 and 0.62, respectively) and Mgex (RPD = 1.72 and 1.49 and r2 = 0.66 and 0.67, respectively). For Caex, very good accuracy was calculated for laboratory method (RPD = 2.19 and r2 = 0.86), as compared to the poor accuracy reported for the on-line method (RPD = 1.30 and r2 = 0.61). The ability of collecting large number of data points per field area (about 12,800 point per 21 ha) and the simultaneous analysis of several soil properties without direct spectral response in the NIR range at relatively high operational speed and appreciable accuracy, encourage the recommendation of the on-line measurement system for site specific fertilisation.
Resumo:
Esta Tesis Doctoral presenta las investigaciones y los trabajos desarrollados durante los años 2008 a 2012 para el análisis y diseño de un patrón primario de ruido térmico de banda ancha en tecnología coaxial. Para ubicar esta Tesis en su campo científico es necesario tomar conciencia de que la realización de mediciones fiables y trazables forma parte del sostenimiento del bienestar de una sociedad moderna y juega un papel crítico en apoyo de la competitividad económica, la fabricación y el comercio, así como de la calidad de vida. En el mundo moderno actual, una infraestructura de medición bien desarrollada genera confianza en muchas facetas de nuestra vida diaria, porque nos permite el desarrollo y fabricación de productos fiables, innovadores y de alta calidad; porque sustenta la competitividad de las industrias y su producción sostenible; además de contribuir a la eliminación de barreras técnicas y de dar soporte a un comercio justo, garantizar la seguridad y eficacia de la asistencia sanitaria, y por supuesto, dar respuesta a los grandes retos de la sociedad moderna en temas tan complicados como la energía y el medio ambiente. Con todo esto en mente se ha desarrollado un patrón primario de ruido térmico con el fin de aportar al sistema metrológico español un nuevo patrón primario de referencia capaz de ser usado para desarrollar mediciones fiables y trazables en el campo de la medida y calibración de dispositivos de ruido electromagnético de radiofrecuencia y microondas. Este patrón se ha planteado para que cumpla en el rango de 10 MHz a 26,5 GHz con las siguientes especificaciones: Salida nominal de temperatura de ruido aproximada de ~ 83 K. Incertidumbre de temperatura de ruido menor que ± 1 K en todo su rango de frecuencias. Coeficiente de reflexión en todo su ancho de banda de 0,01 a 26,5 GHz lo más bajo posible. Se ha divido esta Tesis Doctoral en tres partes claramente diferenciadas. La primera de ellas, que comprende los capítulos 1, 2, 3, 4 y 5, presenta todo el proceso de simulaciones y ajustes de los parámetros principales del dispositivo con el fin de dejar definidos los que resultan críticos en su construcción. A continuación viene una segunda parte compuesta por el capítulo 6 en donde se desarrollan los cálculos necesarios para obtener la temperatura de ruido a la salida del dispositivo. La tercera y última parte, capítulo 7, se dedica a la estimación de la incertidumbre de la temperatura de ruido del nuevo patrón primario de ruido obtenida en el capítulo anterior. Más concretamente tenemos que en el capítulo 1 se hace una exhaustiva introducción del entorno científico en donde se desarrolla este trabajo de investigación. Además se detallan los objetivos que se persiguen y se presenta la metodología utilizada para conseguirlos. El capítulo 2 describe la caracterización y selección del material dieléctrico para el anillo del interior de la línea de transmisión del patrón que ponga en contacto térmico los dos conductores del coaxial para igualar las temperaturas entre ambos y mantener la impedancia característica de todo el patrón primario de ruido. Además se estudian las propiedades dieléctricas del nitrógeno líquido para evaluar su influencia en la impedancia final de la línea de transmisión. En el capítulo 3 se analiza el comportamiento de dos cargas y una línea de aire comerciales trabajando en condiciones criogénicas. Se pretende con este estudio obtener la variación que se produce en el coeficiente de reflexión al pasar de temperatura ambiente a criogénica y comprobar si estos dispositivos resultan dañados por trabajar a temperaturas criogénicas; además se estudia si se modifica su comportamiento tras sucesivos ciclos de enfriamiento – calentamiento, obteniendo una cota de la variación para poder así seleccionar la carga que proporcione un menor coeficiente de reflexión y una menor variabilidad. En el capítulo 4 se parte del análisis de la estructura del anillo de material dieléctrico utilizada en la nota técnica NBS 1074 del NIST con el fin de obtener sus parámetros de dispersión que nos servirán para calcular el efecto que produce sobre el coeficiente de reflexión de la estructura coaxial completa. Además se realiza un estudio posterior con el fin de mejorar el diseño de la nota técnica NBS 1074 del NIST, donde se analiza el anillo de material dieléctrico, para posteriormente realizar modificaciones en la geometría de la zona donde se encuentra éste con el fin de reducir la reflexión que produce. Concretamente se estudia el ajuste del radio del conductor interior en la zona del anillo para que presente la misma impedancia característica que la línea. Y para finalizar se obtiene analíticamente la relación entre el radio del conductor interior y el radio de la transición de anillo térmico para garantizar en todo punto de esa transición la misma impedancia característica, manteniendo además criterios de robustez del dispositivo y de fabricación realistas. En el capítulo 5 se analiza el comportamiento térmico del patrón de ruido y su influencia en la conductividad de los materiales metálicos. Se plantean las posibilidades de que el nitrógeno líquido sea exterior a la línea o que éste penetre en su interior. En ambos casos, dada la simetría rotacional del problema, se ha simulado térmicamente una sección de la línea coaxial, es decir, se ha resuelto un problema bidimensional, aunque los resultados son aplicables a la estructura real tridimensional. Para la simulación térmica se ha empleado la herramienta PDE Toolbox de Matlab®. En el capítulo 6 se calcula la temperatura de ruido a la salida del dispositivo. Se parte del estudio de la aportación a la temperatura de ruido final de cada sección que compone el patrón. Además se estudia la influencia de las variaciones de determinados parámetros de los elementos que conforman el patrón de ruido sobre las características fundamentales de éste, esto es, el coeficiente de reflexión a lo largo de todo el dispositivo. Una vez descrito el patrón de ruido electromagnético se procede, en el capítulo 7, a describir los pasos seguidos para estimar la incertidumbre de la temperatura de ruido electromagnético a su salida. Para ello se utilizan dos métodos, el clásico de la guía para la estimación de la incertidumbre [GUM95] y el método de simulación de Monte Carlo. En el capítulo 8 se describen las conclusiones y lo logros conseguidos. Durante el desarrollo de esta Tesis Doctoral se ha obtenido un dispositivo novedoso susceptible de ser patentado, que ha sido registrado en la Oficina Española de Patentes y Marcas (O.E.P.M.) en Madrid, de conformidad con lo establecido en el artículo 20 de la Ley 11/1986, de 20 de Marzo, de Patentes, con el título Patrón Primario de Ruido Térmico de Banda Ancha (Referencia P-101061) con fecha 7 de febrero de 2011. ABSTRACT This Ph. D. work describes a number of investigations that were performed along the years 2008 to 2011, as a preparation for the study and design of a coaxial cryogenic reference noise standard. Reliable and traceable measurement underpins the welfare of a modern society and plays a critical role in supporting economic competitiveness, manufacturing and trade as well as quality of life. In our modern world, a well developed measurement infrastructure gives confidence in many aspects of our daily life, for example by enabling the development and manufacturing of reliable, high quality and innovative products; by supporting industry to be competitive and sustainable in its production; by removing technical barriers to trade and supporting fair trade; by ensuring safety and effectiveness of healthcare; by giving response to the major challenges in key sectors such energy and environment, etc. With all this in mind we have developed a primary standard thermal noise with the aim of providing the Spanish metrology system with a new primary standard for noise reference. This standard will allow development of reliable and traceable measurements in the field of calibration and measurement of electromagnetic noise RF and microwave devices. This standard has been designed to work in the frequency range from 10 MHz to 26.5 GHz, meeting the following specifications: 1. Noise temperature output is to be nominally ~ 83 K. 2. Noise temperature uncertainty less than ± 1 K in the frequency range from 0.01 to 26.5 GHz. 3. Broadband performance requires as low a reflection coefficient as possible from 0.01 to 26.5 GHz. The present Ph. D. work is divided into three clearly differentiated parts. The first one, which comprises Chapters 1 to 5, presents the whole process of simulation and adjustment of the main parameters of the device in order to define those of them which are critical for the manufacturing of the device. Next, the second part consists of Chapter 6 where the necessary computations to obtain the output noise temperature of the device are carried out. The third and last part, Chapter 7, is devoted to the estimation of the uncertainty related to the noise temperature of the noise primary standard as obtained in the preceding chapter. More specifically, Chapter 1 provides a thorough introduction to the scientific and technological environment where this research takes place. It also details the objectives to be achieved and presents the methodology used to achieve them. Chapter 2 describes the characterization and selection of the bead dielectric material inside the transmission line, intended to connect the two coaxial conductors equalizing the temperature between the two of them and thus keeping the characteristic impedance constant for the whole standard. In addition the dielectric properties of liquid nitrogen are analyzed in order to assess their influence on the impedance of the transmission line. Chapter 3 analyzes the behavior of two different loads and of a commercial airline when subjected to cryogenic working conditions. This study is intended to obtain the variation in the reflection coefficient when the temperature changes from room to cryogenic temperature, and to check whether these devices can be damaged as a result of working at cryogenic temperatures. Also we try to see whether the load changes its behavior after successive cycles of cooling / heating, in order to obtain a bound for the allowed variation of the reflection coefficient of the load. Chapter 4 analyzes the ring structure of the dielectric material used in the NBS technical note 1074 of NIST, in order to obtain its scattering parameters that will be used for computation of its effect upon the reflection coefficient of the whole coaxial structure. Subsequently, we perform a further investigation with the aim of improving the design of NBS technical note 1074 of NIST, and modifications are introduced in the geometry of the transition area in order to reduce the reflection it produces. We first analyze the ring, specifically the influence of the radius of inner conductor of the bead, and then make changes in its geometry so that it presents the same characteristic impedance as that of the line. Finally we analytically obtain the relationship between the inner conductor radius and the radius of the transition from ring, in order to ensure the heat flow through the transition thus keeping the same reflection coefficient, and at the same time meeting the robustness requirements and the feasibility of manufacturing. Chapter 5 analyzes the thermal behavior of the noise standard and its influence on the conductivity of metallic materials. Both possibilities are raised that the liquid nitrogen is kept outside the line or that it penetrates inside. In both cases, given the rotational symmetry of the structure, we have simulated a section of coaxial line, i.e. the equivalent two-dimensional problem has been resolved, although the results are applicable to the actual three-dimensional structure. For thermal simulation Matlab™ PDE Toolbox has been used. In Chapter 6 we compute the output noise temperature of the device. The starting point is the analysis of the contribution to the overall noise temperature of each section making up the standard. Moreover the influence of the variations in the parameters of all elements of the standard is analyzed, specifically the variation of the reflection coefficient along the entire device. Once the electromagnetic noise standard has been described and analyzed, in Chapter 7 we describe the steps followed to estimate the uncertainty of the output electromagnetic noise temperature. This is done using two methods, the classic analytical approach following the Guide to the Estimation of Uncertainty [GUM95] and numerical simulations made with the Monte Carlo method. Chapter 8 discusses the conclusions and achievements. During the development of this thesis, a novel device was obtained which was potentially patentable, and which was finally registered through the Spanish Patent and Trademark Office (SPTO) in Madrid, in accordance with the provisions of Article 20 of Law 11/1986 about Patents, dated March 20th, 1986. It was registered under the denomination Broadband Thermal Noise Primary Standard (Reference P-101061) dated February 7th, 2011.
Resumo:
Maximizing energy autonomy is a consistent challenge when deploying mobile robots in ionizing radiation or other hazardous environments. Having a reliable robot system is essential for successful execution of missions and to avoid manual recovery of the robots in environments that are harmful to human beings. For deployment of robots missions at short notice, the ability to know beforehand the energy required for performing the task is essential. This paper presents a on-line method for predicting energy requirements based on the pre-determined power models for a mobile robot. A small mobile robot, Khepera III is used for the experimental study and the results are promising with high prediction accuracy. The applications of the energy prediction models in energy optimization and simulations are also discussed along with examples of significant energy savings.
Resumo:
This letter presents signal processing techniques to detect a passive thermal threshold detector based on a chipless time-domain ultrawideband (UWB) radio frequency identification (RFID) tag. The tag is composed by a UWB antenna connected to a transmission line, in turn loaded with a biomorphic thermal switch. The working principle consists of detecting the impedance change of the thermal switch. This change occurs when the temperature exceeds a threshold. A UWB radar is used as the reader. The difference between the actual time sample and a reference signal obtained from the averaging of previous samples is used to determine the switch transition and to mitigate the interferences derived from clutter reflections. A gain compensation function is applied to equalize the attenuation due to propagation loss. An improved method based on the continuous wavelet transform with Morlet wavelet is used to overcome detection problems associated to a low signal-to-noise ratio at the receiver. The average delay profile is used to detect the tag delay. Experimental measurements up to 5 m are obtained.
Resumo:
The authors study experimentally ~10 ps return-to-zero pulse propagation near the net dispersion zero of an optical fibre transmission line. Stable near-jitter-free propagation was observed over 70 Mm. Pulse stabilisation and ASE suppression were achieved through the saturable aborber mechanism of nonlinear polarisation rotation.
Resumo:
This thesis presents results of transmission experiments using optical solitons in a dispersion managed optical fibre recirculating loop. The basic concepts of pulse propagation in optical fibre are introduced before optical solitons and their use in optically amplified fibre systems are discussed. The role of dispersion management in such systems is then considered. The design, operation and limitations of the recirculating loop and soliton sources which were used and the experimental techniques are described before the experimental work is presented. The experimental work covers a number of areas all of which used dispersion management of the transmission line. A novel ultra-long distance propagation scheme which achieved low timing jitter by suppression of the amplifier noise and by working close to the zero dispersion wavelength has been discovered. The use of fibre Bragg gratings as wavelength filters to suppress noise and reduce timing jitter has been investigated. The performance of the fibre grating cornpared favourably with that of a bulk device and was in good agreement with theoretical predictions. The upgrade of existing standard fibre systems to higher bit rates is currently an important issue. The possibility of using solitons with dispersion compensation to allow an increase in data rate of existing standard fibre systems to 10Gbit/s over 5000km has been demonstrated. The applicability of this technique to longer distances, higher bit rates or longer amplifier spans is also investigated by optimisation of the dispersion management scheme. The use of fibre Bragg gratings as the dispersion compensating elements in such standard fibre transmission experiments has been examined and the main problem that these devices currently have, high polarisation mode dispersion, is discussed. The likely future direction of optical communications and what part solitons and dispersion management will play in this development is discussed in the thesis conclusions
Resumo:
A methodology is presented which can be used to produce the level of electromagnetic interference, in the form of conducted and radiated emissions, from variable speed drives, the drive that was modelled being a Eurotherm 583 drive. The conducted emissions are predicted using an accurate circuit model of the drive and its associated equipment. The circuit model was constructed from a number of different areas, these being: the power electronics of the drive, the line impedance stabilising network used during the experimental work to measure the conducted emissions, a model of an induction motor assuming near zero load, an accurate model of the shielded cable which connected the drive to the motor, and finally the parasitic capacitances that were present in the drive modelled. The conducted emissions were predicted with an error of +/-6dB over the frequency range 150kHz to 16MHz, which compares well with the limits set in the standards which specify a frequency range of 150kHz to 30MHz. The conducted emissions model was also used to predict the current and voltage sources which were used to predict the radiated emissions from the drive. Two methods for the prediction of the radiated emissions from the drive were investigated, the first being two-dimensional finite element analysis and the second three-dimensional transmission line matrix modelling. The finite element model took account of the features of the drive that were considered to produce the majority of the radiation, these features being the switching of the IGBT's in the inverter, the shielded cable which connected the drive to the motor as well as some of the cables that were present in the drive.The model also took account of the structure of the test rig used to measure the radiated emissions. It was found that the majority of the radiation produced came from the shielded cable and the common mode currents that were flowing in the shield, and that it was feasible to model the radiation from the drive by only modelling the shielded cable. The radiated emissions were correctly predicted in the frequency range 30MHz to 200MHz with an error of +10dB/-6dB. The transmission line matrix method modelled the shielded cable which connected the drive to the motor and also took account of the architecture of the test rig. Only limited simulations were performed using the transmission line matrix model as it was found to be a very slow method and not an ideal solution to the problem. However the limited results obtained were comparable, to within 5%, to the results obtained using the finite element model.