986 resultados para Underwater passive acoustic monitoring
Resumo:
During the last years, there has been much concern about learning management systems' (LMS) effectiveness when compared to traditional learning and about how to assess students' participation during the course. The tracking and monitoring capabilities of most recent LMS have made it possible to analyse every interaction in the system. The issues addressed on this study are: a) Is LMS student's interaction an indicator of academic performance?; b) Are different results in performance expected between distance and in-class LMS-supported education?; c) How can LMS interactions from logs be categorised?; d) May this categorisation detect 'learning witnesses'? To answer these questions, a set of interaction types from Moodle LMS activity record logs has been analysed during two years in online and in-class Master's degrees at the UPM. The results show partial or no evidence of influence between interaction indicators and academic performance, although the proposed categorisation may help detect learning witnesses.
Resumo:
This thesis investigates the acoustic properties of microperforated panels as an alternative to passive noise control. The first chapters are devoted to the review of analytical models to obtain the acoustic impedance and absorption coefficient of perforated panels. The use of panels perforated with circular holes or with slits is discussed. The theoretical models are presented and some modifications are proposed to improve the modeling of the physical phenomena occurring at the perforations of the panels. The absorption band is widened through the use of multiple layer microperforated panels and/or the combination of a millimetric panel with a porous layer that can be a fibrous material or a nylon mesh. A commercial micrometric mesh downstream a millimetric panel is proposed as a very efficient and low cost solution for controlling noise in reduced spaces. The simulated annealing algorithm is used in order to optimize the panel construction to provide a maximum of absorption in a determined wide band frequency range. Experiments are carried out at normal sound incidence and plane waves. One example is shown for a double layer microperforated panel subjected to grazing flow. A good agreement is achieved between the theory and the experiments. RESUMEN En esta tesis se investigan las propiedades acústicas de paneles micro perforados como una alternativa al control pasivo del ruido. Los primeros capítulos están dedicados a la revisión de los modelos de análisis para obtener la impedancia acústica y el coeficiente de absorción de los paneles perforados. El uso de paneles perforados con agujeros circulares o con ranuras es discutido. Se presentan diferentes modelos y se proponen algunas modificaciones para mejorar la modelización de los fenómenos físicos que ocurren en las perforaciones. La banda de absorción se ensancha a través del uso de capas múltiples de paneles micro perforados y/o la combinación de un panel de perforaciones milimétricas combinado con una capa porosa que puede ser un material fibroso o una malla de nylon. Se propone el uso de una malla micrométrica detrás de un panel milimétrico como una solución económica y eficiente para el control del ruido en espacios reducidos. El algoritmo de recocido simulado se utiliza con el fin de optimizar la construcción de paneles micro perforados para proporcionar un máximo de absorción en una banda determinada frecuencias. Los experimentos se llevan a cabo en la incidencia normal de sonido y ondas planas. Se muestra un ejemplo de panel micro perforado de doble capa sometido a flujo rasante. Se consigue un buen acuerdo entre la teoría y los experimentos.
Resumo:
Intraoral devices for bite-force sensing have several applications in odontology and maxillofacial surgery, as bite-force measurements provide additional information to help understand the characteristics of bruxism disorders and can also be of help for the evaluation of post-surgical evolution and for comparison of alternative treatments. A new system for measuring human bite forces is proposed in this work. This system has future applications for the monitoring of bruxism events and as a complement for its conventional diagnosis. Bruxism is a pathology consisting of grinding or tight clenching of the upper and lower teeth, which leads to several problems such as lesions to the teeth, headaches, orofacial pain and important disorders of the temporomandibular joint. The prototype uses a magnetic field communication scheme similar to low-frequency radio frequency identification (RFID) technology (NFC). The reader generates a low-frequency magnetic field that is used as the information carrier and powers the sensor. The system is notable because it uses an intra-mouth passive sensor and an external interrogator, which remotely records and processes information regarding a patient?s dental activity. This permits a quantitative assessment of bite-force, without requiring intra-mouth batteries, and can provide supplementary information to polysomnographic recordings, current most adequate early diagnostic method, so as to initiate corrective actions before irreversible dental wear appears. In addition to describing the system?s operational principles and the manufacture of personalized prototypes, this report will also demonstrate the feasibility of the system and results from the first in vitro and in vivo trials.
Resumo:
Tool wear detection is a key issue for tool condition monitoring. The maximization of useful tool life is frequently related with the optimization of machining processes. This paper presents two model-based approaches for tool wear monitoring on the basis of neuro-fuzzy techniques. The use of a neuro-fuzzy hybridization to design a tool wear monitoring system is aiming at exploiting the synergy of neural networks and fuzzy logic, by combining human reasoning with learning and connectionist structure. The turning process that is a well-known machining process is selected for this case study. A four-input (i.e., time, cutting forces, vibrations and acoustic emissions signals) single-output (tool wear rate) model is designed and implemented on the basis of three neuro-fuzzy approaches (inductive, transductive and evolving neuro-fuzzy systems). The tool wear model is then used for monitoring the turning process. The comparative study demonstrates that the transductive neuro-fuzzy model provides better error-based performance indices for detecting tool wear than the inductive neuro-fuzzy model and than the evolving neuro-fuzzy model.
Resumo:
This article investigates experimentally the application of health monitoring techniques to assess the damage on a particular kind of hysteretic (metallic) damper called web plastifying dampers, which are subjected to cyclic loading. In general terms, hysteretic dampers are increasingly used as passive control systems in advanced earthquake-resistant structures. Nonparametric statistical processing of the signals obtained from simple vibration tests of the web plastifying damper is used here to propose an area index damage. This area index damage is compared with an alternative energy-based index of damage proposed in past research that is based on the decomposition of the load?displacement curve experienced by the damper. Index of damage has been proven to accurately predict the level of damage and the proximity to failure of web plastifying damper, but obtaining the load?displacement curve for its direct calculation requires the use of costly instrumentation. For this reason, the aim of this study is to estimate index of damage indirectly from simple vibration tests, calling for much simpler and cheaper instrumentation, through an auxiliary index called area index damage. Web plastifying damper is a particular type of hysteretic damper that uses the out-of-plane plastic deformation of the web of I-section steel segments as a source of energy dissipation. Four I-section steel segments with similar geometry were subjected to the same pattern of cyclic loading, and the damage was evaluated with the index of damage and area index damage indexes at several stages of the loading process. A good correlation was found between area index damage and index of damage. Based on this correlation, simple formulae are proposed to estimate index of damage from the area index damage.
Resumo:
The study of the temperature gradients in cold stores and containers is a critical issue in the food industry for the quality assurance of products during transport and for minimising losses. This work presents an analysis of the temperatures during the refrigerated transport of 4,320 kg of blueberries in a reefer (set point temperature at ?1ºC) on a container ship from Montevideo (Uruguay) to Verona (Italy). The monitoring was performed by using semi-passive RFID loggers (TurboTag cards). The objective was to carry out a multi-distributed supervision using low-cost, wireless and autonomous sensors for the characterisation of the distribution and spatial gradients of temperatures during a long distance transport. Data analysis shows spatial (phase space) and temporal sequencing diagrams and reveals a significant heterogeneity of temperature at different locations in the container, which highlights the ineffectiveness of a temperature control system based on a single sensor, as is usually done.
Resumo:
The paper proposes a new application of non-parametric statistical processing of signals recorded from vibration tests for damage detection and evaluation on I-section steel segments. The steel segments investigated constitute the energy dissipating part of a new type of hysteretic damper that is used for passive control of buildings and civil engineering structures subjected to earthquake-type dynamic loadings. Two I-section steel segments with different levels of damage were instrumented with piezoceramic sensors and subjected to controlled white noise random vibrations. The signals recorded during the tests were processed using two non-parametric methods (the power spectral density method and the frequency response function method) that had never previously been applied to hysteretic dampers. The appropriateness of these methods for quantifying the level of damage on the I-shape steel segments is validated experimentally. Based on the results of the random vibrations, the paper proposes a new index that predicts the level of damage and the proximity of failure of the hysteretic damper
Resumo:
This paper presents the experimental results obtained by applying frequency-domain structural health monitoring techniques to assess the damage suffered on a special type of damper called Web Plastifying Damper (WPD). The WPD is a hysteretic type energy dissipator recently developed for the passive control of structures subjected to earthquakes. It consists of several I-section steel segments connected in parallel. The energy is dissipated through plastic deformations of the web of the I-sections, which constitute the dissipative parts of the damper. WPDs were subjected to successive histories of dynamically-imposed cyclic deformations of increasing magnitude with the shaking table of the University of Granada. To assess the damage to the web of the I-section steel segments after each history of loading, a new damage index called Area Index of Damage (AID) was obtained from simple vibration tests. The vibration signals were acquired by means of piezoelectric sensors attached on the I-sections, and non-parametric statistical methods were applied to calculate AID in terms of changes in frequency response functions. The damage index AID was correlated with another energy-based damage index-ID- which past research has proven to accurately characterize the level of mechanical damage. The ID is rooted in the decomposition of the load-displacement curve experienced by the damper into the so-called skeleton and Bauschinger parts. ID predicts the level of damage and the proximity to failure of the damper accurately, but it requires costly instrumentation. The experiments reported in this paper demonstrate a good correlation between AID and ID in a realistic seismic loading scenario consisting of dynamically applied arbitrary cyclic loads. Based on this correlation, it is possible to estimate ID indirectly from the AID, which calls for much simpler and less expensive instrumentation.
Resumo:
Two water quality monitoring strategies designed to sample hydrophobic organic contaminants have been applied and evaluated across an expected concentration gradient in PAHs in the Moreton region. Semipermeable membrane devices (SPMDs) that sequester contaminants via passive diffusion across a membrane were used to evaluate the concentration of PAHs at four and five sites in spring and summer 2001/2002, respectively. In addition, induction of hepatic cytochrome P4501, EROD activity, in yellowfin bream, Acanthopagrus australis, captured in the vicinity of SPMD sampling sites following deployment in summer was used as a biomarker of exposure to PAHs and related chemicals. SPMDs identified a clear and reproducible gradient in PAH contamination with levels increasing from east to west in Moreton Bay and upstream in the Brisbane River. The highest PAH concentrations expressed as B(a)P-toxicity equivalents (TEQs) were found in urban areas, which were also furthest upstream and experienced the least flushing. Cytochrome P4501 induction in A. australis was similar at all sites. The absence of clear trends in EROD activity may be attributable to factors not measured in this study or variable residency time of A. australis in contaminated areas. It is also possible that fish in the Moreton region are displaying enzymatic adaptation, which has been reported previously for fish subjected to chronic exposure to organic contaminants. These potential interferences complicate interpretation of EROD activity from feral biota. It is, therefore, suggested that future monitoring combine the two methods by applying passive sampler extracts to in vitro EROD assays. (C) 2004 Elsevier Ltd. All rights reserved.
Resumo:
The proximity of the Great Barrier Reef (GBR) Marine Park to areas of intensive agriculture and increasing urbanisation places the park under potential threat of contamination by land-based pollutants. Passive samplers were deployed at inshore reef and river mouth sites in the Wet Tropics region of the GBR during a dry and a wet season to measure levels of land-based organic pollutants in this environment. Two types of passive sampling devices were deployed: (i) a polar sampler, which can be used to monitor polar herbicides and (ii) semipermeable membrane devices (SPMDs) which sequester more hydrophobic compounds (e.g. PAHs, chlorpyrifos). Herbicides (diuron, simazine, atrazine, hexazinone and/or flumeturon) were detected at low concentrations (ng L-1) at all sites sampled and in both seasons. Chlorpyrifos was not detected while PAHs were present in SPMDs at levels below limits of detection. The results show that the GBR environment does contain low levels of organic pollutants and that passive sampling provides a sensitive monitoring tool for measuring waterborne organic pollutants. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Water-sampler equilibrium partitioning coefficients and aqueous boundary layer mass transfer coefficients for atrazine, diuron, hexazionone and fluometuron onto C18 and SDB-RPS Empore disk-based aquatic passive samplers have been determined experimentally under a laminar flow regime (Re = 5400). The method involved accelerating the time to equilibrium of the samplers by exposing them to three water concentrations, decreasing stepwise to 50% and then 25% of the original concentration. Assuming first-order Fickian kinetics across a rate-limiting aqueous boundary layer, both parameters are determined computationally by unconstrained nonlinear optimization. In addition, a method of estimation of mass transfer coefficients-therefore sampling rates-using the dimensionless Sherwood correlation developed for laminar flow over a flat plate is applied. For each of the herbicides, this correlation is validated to within 40% of the experimental data. The study demonstrates that for trace concentrations (sub 0.1 mu g/L) and these flow conditions, a naked Empore disk performs well as an integrative sampler over short deployments (up to 7 days) for the range of polar herbicides investigated. The SDB-RPS disk allows a longer integrative period than the C18 disk due to its higher sorbent mass and/or its more polar sorbent chemistry. This work also suggests that for certain passive sampler designs, empirical estimation of sampling rates may be possible using correlations that have been available in the chemical engineering literature for some time.
Resumo:
Semi-permeable membrane devices (SPMDs) were loaded with deuterated anthracene and pyrene as performance reference compounds (PRCs) and deployed at a test site in four different chambers (open and closed box chamber, bowl chamber and cage chamber) for 29 days. The losses of PRCs and the uptake of polyaromatic hydrocarbons (PAHs) from the ambient air were quantified. UV-B levels measured in each deployment chamber indicated that SPMDs would be exposed to the most UV-B in the cage chamber and open box chamber. Significantly less PAHs were quantified in SPMDs deployed in the cage chamber and open box chamber compared to samplers from the other two chambers, suggesting that photodegradation of PAHs had occurred. The loss of PRCs confirmed these results but also showed that photodegradation was occurring in the closed box chamber. The bowl chamber appears to provide the best protection from the influence of direct photodegradation. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
In this paper, we present experimental results for monitoring long distance WDM communication links using a line monitoring system suitable for legacy optically amplified long-haul undersea systems. This monitoring system is based on setting up a simple, passive, low cost high-loss optical loopback circuit at each repeater that provides a connection between the existing anti-directional undersea fibres, and can be used to define fault location. Fault location is achieved by transmitting a short pulse supervisory signal along with the WDM data signals where a portion of the overall signal is attenuated and returned to the transmit terminal by the loopback circuit. A special receiver is used at the terminal to extract the weakly returned supervisory signal where each supervisory signal is received at different times corresponding to different optical repeaters. Therefore, the degradation in any repeater appears on its corresponding supervisory signal level. We use a recirculating loop to simulate a 4600 km fibre link, on which a high-loss loopback supervisory system is implemented. Successful monitoring is accomplished through the production of an appropriate supervisory signal at the terminal that is detected and identified in a satisfactory time period after passing through up to 45 dB attenuation in the loopback circuit. © 2012 Elsevier B.V. All rights reserved.
Resumo:
An experimental investigation into the Acoustic Emission (AE) response of sand has been undertaken, and the use of AE as a method of yield point identification has been assessed. Dense, saturated samples of sand were tested in conventional triaxial apparatus. The measurements of stresses and strains were carried out according to current research practice. The AE monitoring system was integrated with the soil mechanics equipment in such a way that sample disturbance was minimised. During monotonically loaded, constant cell pressure tests the total number of events recorded was found to increase at an increasing rate in a manner which may be approximated by a power law. The AE response of the sand was found to be both stress level and stress path dependent. Undrained constant cell pressure tests showed that, unlike drained tests, the AE event rate increased at an increasing rate; this was shown to correlate with the mean effective stress variation. The stress path dependence was most noticeable in extension tests, where the number of events recorded was an order of magnitude less than that recorded in comparable compression tests. This stress path dependence was shown to be due to the differences in the work done by the external stresses. In constant cell pressure tests containing unload/reload cycles it was found that yield could be identified from a discontinuity in the event rate/time curve which occurred during reloading. Further tests involving complex stress paths showed that AE was a useful method of yield point identification. Some tests involving large stress reversals were carried out, and AE identified the inverse yield points more distinctly than conventional methods of yield point identification.