952 resultados para Underground excavation
Resumo:
In an earthquake, underground structures located in liquefiable soil deposits are susceptible to floatation following an earthquake event due to their lower unit weight relative to the surrounding saturated soil. The uplift displacement of an underground structure in liquefiable soil deposit can be affected by the buried depth and size of the structure. Dynamic centrifuge tests have been carried out to investigate the influence of these factors by measuring the uplift displacement of shallow model circular structures. Ratios for the buried depth and diameter effects of the structure are introduced to compare the uplift displacement in different soil and earthquake conditions. With the depth effect and diameter effect ratios, the uplift displacement of a buoyant structure in liquefiable soil can also be estimated based on performance of similar structures in comparable soil condition and subjected to a similar earthquake event. © 2012 Elsevier Ltd.
Resumo:
Advances in the development of computer vision, miniature Micro-Electro-Mechanical Systems (MEMS) and Wireless Sensor Network (WSN) offer intriguing possibilities that can radically alter the paradigms underlying existing methods of condition assessment and monitoring of ageing civil engineering infrastructure. This paper describes some of the outcomes of the European Science Foundation project "Micro-Measurement and Monitoring System for Ageing Underground Infrastructures (Underground M3)". The main aim of the project was to develop a system that uses a tiered approach to monitor the degree and rate of tunnel deterioration. The system comprises of (1) Tier 1: Micro-detection using advances in computer vision and (2) Tier 2: Micro-monitoring and communication using advances in MEMS and WSN. These potentially low-cost technologies will be able to reduce costs associated with end-of-life structures, which is essential to the viability of rehabilitation, repair and reuse. The paper describes the actual deployment and testing of these innovative monitoring tools in tunnels of London Underground, Prague Metro and Barcelona Metro. © 2012 Taylor & Francis Group.
Resumo:
Deep excavations and tunnelling can cause ground movements that affect buildings within their influence zone. The current approach for building damage assessment is based on tensile strains estimated from the deflection ratio and the horizontal strains at the building foundation. This paper examines the significance of horizontal strains in buildings on individual footings. The first part of the paper presents a case study of a framed building in Singapore which was subjected to the effects of bored tunnelling, where significant horizontal strains were observed. The second part of the paper suggests a method to relate the horizontal strains induced in a building to the stiffness of the frame structure. Using a combination of simplified structural analysis and finite element models, design guidance is proposed to estimate excavation-induced horizontal strains in frame buildings on individual footings. © 2012 Taylor & Francis Group.
Resumo:
The vibration response of piled foundations due to ground-borne vibration produced by an underground railway is a largely-neglected area in the field of structural dynamics. However, this continues to be an important aspect of research as it is expected that the presence of piled foundations can have a significant influence on the propagation and transmission of the wavefield produced by the underground railway. This paper presents a comparison of two methods that can be employed in calculating the vibration response of a piled foundation: an efficient semi-analytical model, and a Boundary Element model. The semi-analytical model uses a column or an Euler beam to model the pile, and the soil is modelled as a linear, elastic continuum that has the geometry of a thick-walled cylinder with an infinite outer radius and an inner radius equal to the radius of the pile. The boundary element model uses a constant-element BEM formulation for the halfspace, and a rectangular discretisation of the circular pile-soil interface. The piles are modelled as Timoshenko beams. Pile-soil-pile interactions are inherently accounted for in the BEM equations, whereas in the semi-analytical model these are quantified using the superposition of interaction factors. Both models use the method of joining subsystems to incorporate the incident wavefield generated by the underground railway into the pile model. Results are computed for a single pile subject to an inertial loading, pile-soil-pile interactions, and a pile group subjected to excitation from an underground railway. The two models are compared in terms of accuracy, computation time, versatility and applicability, and guidelines for future vibration prediction models involving piled foundations are proposed.
Resumo:
Ground vibration due to underground railways is a significant source of disturbance for people living or working near subways. Numerical models are commonly used to predict vibration levels; however, uncertainty inherent to these simulations must be understood to give confidence in the predictions. A semi-analytical approach is developed herein to investigate the effect of uncertainty in soil material properties on the surface vibration of layered halfspaces excited by an underground railway. The half-space is simulated using the thin-layer method coupled with the pipe-in-pipe (PiP) method for determining the load on the buried tunnel. The K-L expansion method is employed to smoothly vary the material properties throughout the soil by up to 10%. The simulation predicts a surface rms velocity variation of 5-10dB compared to a homogeneous, layered halfspace. These results suggest it may be prudent to include a 5dB error band on predicted vibration levels when simulating areas of varied material properties.
Resumo:
In an earthquake, underground structures located in liquefiable soil deposits are susceptible to floatation following an earthquake event due to their lower unit weight relative to the surrounding saturated soil. Such uplift response of the buoyant structure is influenced by the soil it is buried in. In the case of a liquefiable soil deposit, the soil can lose its shear strength significantly in the event of an earthquake. If the soil liquefies fully, the buoyant structure can float towards the soil surface. However, a partly liquefied soil deposit retains some of its initial shear strength and resists the uplift. This paper discusses the different soil conditions and their influence on the uplift response of buoyant structures. © 2012 World Scientific Publishing Company.
Resumo:
Underground structures located in liquefiable soil deposits are susceptible to floatation following an earthquake event due to their lower unit weight relative to the surrounding saturated soil. This inherent buoyancy may cause lightweight structures to float when the soil liquefies. Centrifuge tests have been carried out to study the excess pore pressure generation and dissipation in liquefiable soils. In these tests, near full liquefaction conditions were attained within a few cycles of the earthquake loading. In the case of high hydraulic conductivity sands, significant dissipation could take place even during the earthquake loading which inhibits full liquefaction from occurring. In the case of excess pore pressure generation and dissipation around a floating structure, the cyclic response of the structure may lead to the reduction in excess pore pressure near the face of the structure as compared to the far field. This reduction in excess pore pressure is due to shear-induced dilation and suction pressures arising from extensile stresses at the soil-structure interface. Given the lower excess pore pressure around the structure; the soil around the structure retains a portion of this shear strength which in turn can discourage significant uplift of the underground structure. Copyright © 2012, IGI Global.
Resumo:
The design and construction of deep excavations in urban environment is often governed by serviceability limit state related to the risk of damage to adjacent buildings. In current practice, the assessment of excavation-induced building damage has focused on a deterministic approach. This paper presents a component/system reliability analysis framework to assess the probability that specified threshold design criteria for multiple serviceability limit states are exceeded. A recently developed Bayesian probabilistic framework is used to update the predictions of ground movements in the later stages of excavation based on the recorded deformation measurements. An example is presented to show how the serviceability performance for excavation problems can be assessed based on the component/system reliability analysis. © 2011 ASCE.
Resumo:
The finite element method (FEM) is growing in popularity over the pressure diagram/hand calculation method for analysis of excavation systems in general and deep soil mixing excavations in particular. In this paper, a finite element analysis is used to study the behavior of a deep mixed excavation. Through the use of Plaxis (a FEM software program), the construction sequence is simulated by following the various construction phases allowing for deflections due to strut or anchor installation to be predicted. The numerical model used in this study simulates the soil cement columns as a continuous wall matching the bending stiffness of the actual wall. Input parameters based on laboratory tests and modeling assumptions are discussed. An example of the approach is illustrated using the Islais Creek Transport/Storage Project in San Francisco, California. Copyright ASCE 2006.
Resumo:
Deep mixing is effectively used in excavations both in conjunction with and in substitution of traditional techniques, where it results in more economical and convenient solutions for the stability of the system and the prevention of seepage. Deep mixed walls constructed as part of a soldier pile and tie-backs system act also as temporary support, prevent seepage like a sheet pile wall, but require a lower amount of steel. The deep mixed treatment can also contribute to the stability of the wall system against deep-seated failures. Although deep mixing is currently used for excavation control in numerous projects, no standard procedure has been developed and the different applications have not been evaluated. As this technique emerges as a more economical and effective alternative to traditional excavation shoring, there is a need for guidelines describing proven procedures for evaluation of design, analysis and construction. This paper presents comparisons in the design of excavation support using deep mixing and other traditional techniques. Issues important for design, analysis, and construction of deep mixed excavation walls are also discussed.
Resumo:
Underground structures located in liquefiable soil deposits are susceptible to floatation following an earthquake event due to their lower unit weight relative to the surrounding saturated soil. Centrifuge tests have been carried out to assess the effectiveness of existing remediation techniques in reducing the uplift of underground structures, namely in situ densification and the use of coarse sand backfill. The centrifuge test results showed that these methods do reduce the uplift displacement of buoyant structures. Their performance was thereafter linked to the theoretical mechanism of floatation of underground structures. Based on the understanding from preceding tests, a further improvement on the use of the coarse sand backfill was carried out, which produced a greater reduction in the uplift displacement of the structure. Each of these techniques, however, does pose issues when applied in the field, such as possible damage to surrounding structures, construction issues and maintenance problems.