938 resultados para Underflow diameter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND & AIMS Patients with cirrhosis and variceal hemorrhage have a high risk of rebleeding. We performed a prospective randomized trial to compare the prevention of rebleeding in patients given a small-diameter covered stent vs those given hepatic venous pressure gradient (HVPG)-based medical therapy prophylaxis. METHODS We performed an open-label study of patients with cirrhosis (92% Child class A or B, 70% alcoholic) treated at 10 medical centers in Germany. Patients were assigned randomly more than 5 days after variceal hemorrhage to groups given a small covered transjugular intrahepatic portosystemic stent-shunt (TIPS) (8 mm; n = 90), or medical reduction of portal pressure (propranolol and isosorbide-5-mononitrate; n = 95). HVPG was determined at the time patients were assigned to groups (baseline) and 2 weeks later. In the medical group, patients with an adequate reduction in HVPG (responders) remained on the drugs whereas nonresponders underwent only variceal band ligation. The study was closed 10 months after the last patient was assigned to a group. The primary end point was variceal rebleeding. Survival, safety (adverse events), and quality of life (based on the Short Form-36 health survey) were secondary outcome measures. RESULTS A significantly smaller proportion of patients in the TIPS group had rebleeding within 2 years (7%) than in the medical group (26%) (P = .002). A slightly higher proportion of patients in the TIPS group experienced adverse events, including encephalopathy (18% vs 8% for medical treatment; P = .05). Rebleeding occurred in 6 of 23 patients (26%) receiving medical treatment before hemodynamic control was possible. Per-protocol analysis showed that rebleeding occurred in a smaller proportion of the 32 responders (18%) than in nonresponders who received variceal band ligation (31%) (P = .06). Fifteen patients from the medical group (16%) underwent TIPS placement during follow-up evaluation, mainly for refractory ascites. Survival time and quality of life did not differ between both randomized groups. CONCLUSIONS Placement of a small-diameter, covered TIPS was straightforward and prevented variceal rebleeding in patients with Child A or B cirrhosis more effectively than drugs, which often required step-by-step therapy. However, TIPS did not increase survival time or quality of life and produced slightly more adverse events. Clinical Trial no: ISRCTN 16334693.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND The aim of this study was to compare the 5-year survival and success rates of 3.3 mm dental implants either made from titanium-zirconium (TiZr) alloy or from Grade IV titanium (Ti Grade IV) in mandibular implant-based removable overdentures. METHODS The core study had a follow-up period of 36 months and was designed as a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann Bone Level implants (diameter 3.3 mm, SLActive®), one of TiZr (test) and one of Ti Grade IV (control), in the interforaminal region. This follow-up study recruited patients from the core study and evaluated the plaque and sulcus bleeding indices, radiographic crestal bone level, as well as implant survival and success 60 months after implant placement. RESULTS Of the 91 patients who initially received implants, 75 completed the 36 month follow-up and 49 were available for the 60 month examination. Two patients were excluded so that a total of 47 patients with an average age of 72 ± 8 years were analysed. The characteristics and 36-month performance of the present study cohort did not differ from the non-included initial participants (p > 0.05). In the period since the 36-month follow-up examination, no implant was lost. The cumulative implant survival rate was 98.9 % for the TiZr group and 97.8 % for the Ti Grade IV group. Crestal bone level changes at 60 months were not different in the test and control group (TiZr -0.60 ± 0.69 mm and Ti Grade IV -0.61 ± 0.83 mm; p = 0.96). The cumulative implant success rate after 60 months was 95.8 and 92.6 % for TiZr and Ti Grade IV, respectively. CONCLUSIONS After 60 months, the positive outcomes of the 36 month results for TiZr and Ti Grade IV implants were confirmed, with no significant differences with regard to crestal bone level change, clinical parameters and survival or success rates. TiZr implants performed equally well compared to conventional Ti Grade IV 3.3 mm diameter-reduced implants for mandibular removable overdentures. TRIAL REGISTRATION Registered on www.clinicaltrials.gov: NCT01878331.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE The aim of this study was to compare crestal bone-level changes, soft tissue parameters and implant success and survival between small-diameter implants made of titanium/zirconium (TiZr) alloy or of Grade IV titanium (Ti) in edentulous mandibles restored with removable overdentures. MATERIALS AND METHODS This was a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann bone-level implants (diameter 3.3 mm), one of Ti Grade IV (control) and one of TiZr (test), in the interforaminal region. Implants were loaded after 6-8 weeks and removable Locator-retained overdentures were placed within 2 weeks of loading. Modified plaque and sulcus bleeding indices, radiographic bone level, and implant survival and success were evaluated up to 36 months. RESULTS Of 91 treated patients, 75 completed the three-year follow-up. Three implants were lost (two control and one test implant). The survival rates were 98.7% and 97.3%, and the mean marginal bone level change was -0.78 ± 0.75 and -0.60 ± 0.71 mm for TiZr and Ti Grade IV implants. Most patients had a plaque score of 0 or 1 (54% for test and 51.7% for control), and a sulcus bleeding score of 0 (46.1% for test and 44.9% for control). No significant differences were found between the two implant types for bone-level change, soft tissue parameters, survival and success. CONCLUSIONS After 36 months, similar outcomes were found between Ti Grade IV and TiZr implants. The results confirm that the results seen at 12 months continue over time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For over 3 centuries, diameter-limit harvesting has been a predominant logging method in the northeastern United States. Silvicultural theory asserts that such intensively selective harvesting can lead to genetic degradation. A decrease in softwood productivity has recently been reported in Maine - has a long history of dysgenic selection degraded the genetic resources of Maine softwoods, contributing to a decrease in growth and productivity? This study examines two aspects of potential implications of diameter-limit harvesting: effects on residual phenotypes of red spruce and impacts on genetic diversity of white pine. Radial growth of residual red spruce trees in stands experiencing 50 years of fixed diameter-limit harvesting was measured using annual increment rings and compared with residual red spruce trees in positive selection stands. Trees remaiaing after several rounds of diameter-limit harvesting exhibited sigdicantl y smaller radial sizes throughout their lives, and displayed significantly slower growth rates for the first 80 years of measured growth. These results strongly suggest that the largest and fastest-growing genotypes and their respective gene complexes determining good radial growth have been removed from the diameter-limit stand. Dysgenic selection can be observed in fixed diarneter-limit stands, resulting in a diminished genetic resource and decreased residual stand value. To examine more direct genetic implications of long-term diameter-limit harvesting, microsatellite DNA markers were implemented to study genetic diversity of eastern white pine in Maine. Three age groups of trees were studied: mature trees older than 200 years, juvenile trees 5-30 years old, and embryos. Trees were genotyped at 10 microsatellite loci. Overall genetic diversity levels of eastern white pine in Maine were extremely high, with an average observed heterozygosity of 0.762. Genetic differentiation was minimal among and between all three age groups, although an excess of heterozygotes was shown in the mature and juvenile groups that was not reflected in the embryo group, which actually had a slight heterozygote deficiency. Allele frequencies did not differ significantly between age groups, but did reveal more rare and low frequency alleles in the embryo groups than in the mature group. Overall, low frequency alleles comprise the largest portion of alleles in the sample population, with no common alleles evident overall. These results suggest that significant genetic degradation has either not occurred for white pine, or that the results of dysgenic selection have not yet emerged. It is clear, however, that selective harvesting could result in a loss of low frequency alleles, which are a primary reserve of evolutionary potential in a species. Implications of these studies affect industrial forestry, regional economics, and ecological concerns for the northeast. Long-term diameter-limit harvesting can lead to a degradation of residual phenotypes, and an overall decrease in stand quality. Potentially, a loss of low frequency, locally adapted alleles could result in a decrease of allelic richness and degradation of the regidnal genetic resource. Decreased genetic variation can lead to seriously limited evolutionary potential of species and ecosystems, particularly in rapidly changing environments. Based on these findings, I recommend a reassessment of any harvesting prescription that includes fixed diameter-limit removals, particularly for species that have low natural genetic diversity levels or a limited natural range, such as red spruce. Maintenance of a healthy genetic reserve can avoid effects of dysgenic harvesting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements of the diameter of O. universa carried out on 30 specimens from 39 samples covering a sediment thickness of 78 m and going back in time to approximately 750 000 y resulted in the construction of a curve of the mean diameter and a curve of the maximum diameter. Both curves, as well as those calculated with the running-averages technique, display cyclic fluctuations with durations of the order of 100 000 y and downwards decreasing amplitudes. These curves are compared with a carbonate curve (on bulk sediment) and an isotopic curve (on benthic foraminifers) obtained from the same set of samples. Correlations are fair to good, but a timelag is noticed between the isotopic curve and the faunal (O. universa mean diameter) curve, with the isotopic signal coming first, in the middle part of the Brunhes Epoch. Biostratigraphic calibration to the paleomagnetic record is provided by four datum planes (two based on calcareous nannofossils, two on diatoms) identified in the succession. Changes recorded in test porosity seem to be less meaningful than changes in test size.