997 resultados para Ultrasound extraction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dendrocalamus strictus and Bambusa arundinacea are monocarpic, gregariously flowering species of bamboo, common in the deciduous forests of the State of Karnataka in India. Their populations have significantly declined, especially since the last flowering. This decline parelleis increasing incidence of grazing, fire and extraction in recent decades. Results of an experiment in which the intensities of grazing and fire were varied, indicate that while grazing significantly depresses the survival of seedlings and the recruitment of new eulms of bamboo clumps, fire appeared to enhance seedling survival, presumably by reducing competition of lass fire-resistant species. New shoots of bamboo are destroyed by insects and a variety of herbivorous mammals. In areas of intense herbivore pressure, a bamboo clump initiates the production of a much larger number of new culrm, but results in many fewer and shorter intact culms. Extraction renders the new shoots more susceptible to herbivore pressure by removal of the protective covering of branches at the base of a bamboo clump. Hence, regular and extensive extraction by the paper mills in conjuction with intense grazing pressure strongly depresses the addition of new culms to bamboo clumps. Regulation of grazing in the forest by domestic livestock along with maintenance of the cover at the base of the clumps by extracting the culms at a higher level should reduce the rate of decline of the bamboo stocks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Considering ultrasound propagation through complex composite media as an array of parallel sonic rays, a comparison of computer simulated prediction with experimental data has previously been reported for transmission mode (where one transducer serves as transmitter, the other as receiver) in a series of ten acrylic step-wedge samples, immersed in water, exhibiting varying degrees of transit time inhomogeneity. In this study, the same samples were used but in pulse-echo mode, where the same ultrasound transducer served as both transmitter and receiver, detecting both ‘primary’ (internal sample interface) and ‘secondary’ (external sample interface) echoes. A transit time spectrum (TTS) was derived, describing the proportion of sonic rays with a particular transit time. A computer simulation was performed to predict the transit time and amplitude of various echoes created, and compared with experimental data. Applying an amplitude-tolerance analysis, 91.7±3.7% of the simulated data was within ±1 standard deviation (STD) of the experimentally measured amplitude-time data. Correlation of predicted and experimental transit time spectra provided coefficients of determination (R2) ranging from 100.0% to 96.8% for the various samples tested. The results acquired from this study provide good evidence for the concept of parallel sonic rays. Further, deconvolution of experimental input and output signals has been shown to provide an effective method to identify echoes otherwise lost due to phase cancellation. Potential applications of pulse-echo ultrasound transit time spectroscopy (PE-UTTS) include improvement of ultrasound image fidelity by improving spatial resolution and reducing phase interference artefacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The acceptance of broadband ultrasound attenuation (BUA) for the assessment of osteoporosis suffers from a limited understanding of both ultrasound wave propagation through cancellous bone and its exact dependence upon the material and structural properties. It has recently been proposed that ultrasound wave propagation in cancellous bone may be described by a concept of parallel sonic rays; the transit time of each ray defined by the proportion of bone and marrow propagated. A Transit Time Spectrum (TTS) describes the proportion of sonic rays having a particular transit time, effectively describing the lateral inhomogeneity of transit times over the surface aperture of the receive ultrasound transducer. The aim of this study was to test the hypothesis that the solid volume fraction (SVF) of simplified bone:marrow replica models may be reliably estimated from the corresponding ultrasound transit time spectrum. Transit time spectra were derived via digital deconvolution of the experimentally measured input and output ultrasonic signals, and compared to predicted TTS based on the parallel sonic ray concept, demonstrating agreement in both position and amplitude of spectral peaks. Solid volume fraction was calculated from the TTS; agreement between true (geometric calculation) with predicted (computer simulation) and experimentally-derived values were R2=99.9% and R2=97.3% respectively. It is therefore envisaged that ultrasound transit time spectroscopy (UTTS) offers the potential to reliably estimate bone mineral density and hence the established T-score parameter for clinical osteoporosis assessment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quality of ultrasound computed tomography imaging is primarily determined by the accuracy of ultrasound transit time measurement. A major problem in analysis is the overlap of signals making it difficult to detect the correct transit time. The current standard is to apply a matched-filtering approach to the input and output signals. This study compares the matched-filtering technique with active set deconvolution to derive a transit time spectrum from a coded excitation chirp signal and the measured output signal. The ultrasound wave travels in a direct and a reflected path to the receiver, resulting in an overlap in the recorded output signal. The matched-filtering and deconvolution techniques were applied to determine the transit times associated with the two signal paths. Both techniques were able to detect the two different transit times; while matched-filtering has a better accuracy (0.13 μs vs. 0.18 μs standard deviation), deconvolution has a 3.5 times improved side-lobe to main-lobe ratio. A higher side-lobe suppression is important to further improve image fidelity. These results suggest that a future combination of both techniques would provide improved signal detection and hence improved image fidelity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigates the use of unsupervised features derived from word embedding approaches and novel sequence representation approaches for improving clinical information extraction systems. Our results corroborate previous findings that indicate that the use of word embeddings significantly improve the effectiveness of concept extraction models; however, we further determine the influence that the corpora used to generate such features have. We also demonstrate the promise of sequence-based unsupervised features for further improving concept extraction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method of ion extraction from plasmas is reported in which the interference of field lines due to the extraction system in the plasma region is avoided by proper shaping of the extractor electrode and is supported by field plots.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effective processing of powdered particles can facilitate powder handling and result in better drug product performance, which is of great importance in the pharmaceutical industry where the majority of active pharmaceutical ingredients (APIs) are delivered as solid dosage forms. The purpose of this work was to develop a new ultrasound-assisted method for particle surface modification and thin-coating of pharmaceutical powders. The ultrasound was used to produce an aqueous mist with or without a coating agent. By using the proposed technique, it was possible to decrease the interparticular interactions and improve rheological properties of poorly-flowing water-soluble powders by aqueous smoothing of the rough surfaces of irregular particles. In turn, hydrophilic polymer thin-coating of a hydrophobic substance diminished the triboelectrostatic charge transfer and improved the flowability of highly cohesive powder. To determine the coating efficiency of the technique, the bioactive molecule β-galactosidase was layered onto the surface of powdered lactose particles. Enzyme-treated materials were analysed by assaying the quantity of the reaction product generated during enzymatic cleavage of the milk sugar. A near-linear increase in the thickness of the drug layer was obtained during progressive treatment. Using the enzyme coating procedure, it was confirmed that the ultrasound-assisted technique is suitable for processing labile protein materials. In addition, this pre-treatment of milk sugar could be used to improve utilization of lactose-containing formulations for populations suffering from severe lactose intolerance. Furthermore, the applicability of the thin-coating technique for improving homogeneity of low-dose solid dosage forms was shown. The carrier particles coated with API gave rise to uniform distribution of the drug within the powder. The mixture remained homogeneous during further tabletting, whereas the reference physical powder mixture was subject to segregation. In conclusion, ultrasound-assisted surface engineering of pharmaceutical powders can be effective technology for improving formulation and performance of solid dosage forms such as dry powder inhalers (DPI) and direct compression products.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis discusses the use of sub- and supercritical fluids as the medium in extraction and chromatography. Super- and subcritical extraction was used to separate essential oils from herbal plant Angelica archangelica. The effect of extraction parameters was studied and sensory analyses of the extracts were done by an expert panel. The results of the sensory analyses were compared to the analytically determined contents of the extracts. Sub- and supercritical fluid chromatography (SFC) was used to separate and purify high-value pharmaceuticals. Chiral SFC was used to separate the enantiomers of racemic mixtures of pharmaceutical compounds. Very low (cryogenic) temperatures were applied to substantially enhance the separation efficiency of chiral SFC. The thermodynamic aspects affecting the resolving ability of chiral stationary phases are briefly reviewed. The process production rate which is a key factor in industrial chromatography was optimized by empirical multivariate methods. General linear model was used to optimize the separation of omega-3 fatty acid ethyl esters from esterized fish oil by using reversed-phase SFC. Chiral separation of racemic mixtures of guaifenesin and ferulic acid dimer ethyl ester was optimized by using response surface method with three variables per time. It was found that by optimizing four variables (temperature, load, flowate and modifier content) the production rate of the chiral resolution of racemic guaifenesin by cryogenic SFC could be increased severalfold compared to published results of similar application. A novel pressure-compensated design of industrial high pressure chromatographic column was introduced, using the technology developed in building the deep-sea submersibles (Mir 1 and 2). A demonstration SFC plant was built and the immunosuppressant drug cyclosporine A was purified to meet the requirements of US Pharmacopoeia. A smaller semi-pilot size column with similar design was used for cryogenic chiral separation of aromatase inhibitor Finrozole for use in its development phase 2.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurement of loading patterns of the patellar tendon during activity is important in understanding tendon injury. We used transmission-mode ultrasonography to investigate patellar tendon loading during squatting in adults with and without tendinopathy. It was hypothesized that axial ultrasonic velocity, a surrogate measure of the elastic modulus of tendon, would be lower in tendinopathy. Ultrasound velocity was measured in both patellar tendons of adults with unilateral patellar tendinopathy (n=9) and in healthy controls (n=16) during a bilateral squat manoeuvre. Sagittal knee movement was measured simultaneously with an electrogoniometer. Statistical comparisons between healthy and injured tendons were made using 2–way mixed–design ANOVAs. Axial ultrasound velocity in both symptomatic and asymptomatic patellar tendons in tendinopathy was approximately 15% higher than in healthy tendons at the commencement (F1,23=5.2, P<.05) and completion (F1,23=4.5, P<.05) of the squat. While peak velocity was ≈5% higher during both flexion (F1,23=5.4, P<.05) and extension (F1,23=5.3, P<.05) phases, there was no significant between–group difference at the mid–point of the movement. There were no significant differences in the rate and magnitude of knee movement between groups. Although further research is required, these findings suggest enhanced baseline muscle activity in patellar tendinopathy and highlight fresh avenues for its clinical management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An apparatus is described that facilitates the determination of incorporation levels of isotope labelled, gaseous precursors into volatile insect-derived metabolites. Atmospheres of varying gas compositions can be generated by evacuation of a working chamber followed by admission of the required levels of component gases, using a precision, digitised pressure read-out system. Insects such as fruit-flies are located initially in a small introduction chamber, from which migration can occur downwards into the working chamber. The level of incorporation of labelled precursors is continuously assayed by the Solid Phase Micro Extraction (SPME) technique and GC-MS analyses. Experiments with both Bactrocera species (fruit-flies) and a parasitoid wasp, Megarhyssa nortoni nortoni (Cresson) and oxygen-18 labelled dioxygen illustrate the utility of this system. The isotope effects of oxygen-18 on the carbon-13 NMR spectra of 1,7- dioxaspiro[5,5]undecane are also described.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasound screening is now a routine procedure which forms part of antenatal care provision. Within this routine context ultrasound technology has been found to be generally acceptable and indeed is positively demanded by many women. This paper raises the question whether the routine presentation of ultrasound implicitly conveys the message that is use in antenatal care is both valuable and safe. It examines women's views of ultrasound technology beyond a routine context. In a study designed to examine women's reactions to cerebral ultrasound on their normal term infants mothers were asked their views and knowledge of ultrasound and a comparison with their antenatal experience of ultrasound was elicited. A generalized concern about ultrasound techniques was found to underlie many of the women's comments. This raised questions concerning the current practice in the presentation of ultrasound to women attending for antenatal care.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is shown that lithium can be oxidatively extracted from Li2MoO3 at room temperature using Br2 in CHCl3. The delithiated oxides, Li2â��xMoO3 (0 < x â�¤ 1.5) retain the parent ordered rocksalt structure. Complete removal of lithium from Li2MoO3 using Br2 in CH3CN results in a poorly crystalline MoO3 that transforms to the stable structure at 280�°C. Li2MoO3 undergoes topotactic ion-exchange in aqueous H2SO4 to yield a new protonated oxide, H2MoO3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Salinity, sodicity, acidity, and phytotoxic levels of chloride (Cl) in subsoils are major constraints to crop production in many soils of north-eastern Australia because they reduce the ability of crop roots to extract water and nutrients from the soil. The complex interactions and correlations among soil properties result in multi-colinearity between soil properties and crop yield that makes it difficult to determine which constraint is the major limitation. We used ridge-regression analysis to overcome colinearity to evaluate the contribution of soil factors and water supply to the variation in the yields of 5 winter crops on soils with various levels and combinations of subsoil constraints in the region. Subsoil constraints measured were soil Cl, electrical conductivity of the saturation extract (ECse), and exchangeable sodium percentage (ESP). The ridge regression procedure selected several of the variables used in a descriptive model, which included in-crop rainfall, plant-available soil water at sowing in the 0.90-1.10 m soil layer, and soil Cl in the 0.90-1.10 m soil layer, and accounted for 77-85% of the variation in the grain yields of the 5 winter crops. Inclusion of ESP of the top soil (0.0-0.10 m soil layer) marginally increased the descriptive capability of the models for bread wheat, barley and durum wheat. Subsoil Cl concentration was found to be an effective substitute for subsoil water extraction. The estimates of the critical levels of subsoil Cl for a 10% reduction in the grain yield were 492 mg cl/kg for chickpea, 662 mg Cl/kg for durum wheat, 854 mg Cl/kg for bread wheat, 980 mg Cl/kg for canola, and 1012 mg Cl/kg for barley, thus suggesting that chickpea and durum wheat were more sensitive to subsoil Cl than bread wheat, barley, and canola.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To maximize the information commonly collected from otoliths, the effect of DNA extraction on the estimation of age with otoliths was evaluated by comparing sagittal otolith samples from common coral trout (Plectropomus leopardus) for clarity and ageing discrepancies in DNA-extracted and untreated control otoliths. The DNA extraction process had no significant effect, indicating that archived otoliths can be used as a source of DNA while retaining their utility for age estimation.