987 resultados para UV detection
Resumo:
Lysergic acid diethylamide (LSD) is a potent hallucinogen that is primarily metabolized to 2-oxo-3-hydroxy-LSD (O-H-LSD) and N-desmethyl-LSD (nor-LSD) by cytochrome P450 complex liver enzymes. Due to its extensive metabolism, there still is an interest in the identification of new metabolites and new routes of its metabolism in humans. In the present study, we investigated whether LSD could be a substrate for horseradish peroxidase or myeloperoxidase (MPO). Using liquid chromatography coupled to UV detection and electrospray ionization mass spectrometry (LC-UV-ESI-MS), we found that both peroxidases were capable of metabolizing LSD to the same compounds that have been observed in vivo (i.e., O-H-LSD and nor-LSD). In addition, we found another major metabolite, N,N-diethyl-7-formamido-4-methyl-6-oxo-2,3,4,4a,5,6-hexahydrobenzo[f]quinoline-2-carboxamide (FOMBK), which is an opened indolic ring compound. Hydrolysis of FOMBK led to the deformylated compound 7-amino-N,N-diethyl-4-methyl-6-oxo-2,3,4,4a,5,6-hexahydrobenzo[f]quinoline-2-carboxamide. The reactions of LSD with the peroxidases were chemiluminescent and sensitive to inhibition by reactive oxygen scavengers, which indicated that the classic peroxidase cycle is involved in this new alternative metabolic pathway. Considering that MPO is abundant in immune cells and also present in the central nervous system, the degradation pathway described in this study suggests a possible route of LSD metabolism that may occur concurrently with the in vivo reaction catalyzed by the cytochrome P450 system.
Resumo:
Hydroethanolic extracts of C. langsdorffii leaves have therapeutic potential. This work reports a validated chromatographic method for the quantification of polar compounds in the hydroethanolic extract of C. langsdorffii leaves. A reliable HPLC method was developed using two monolithic columns linked in series (100 x 4.6 mm - C-18), with nonlinear gradient elution, and UV detection set at 257 nm. A procedure for the extraction of flavonols was also developed, which involved the use of 70% aqueous ethanol and the addition of benzophenone as the internal standard. The developed method led to a good detection response as the values for linearity were between 10.3 and 1000 mu g/mL, and those for recovery between 84.2 and 111.1%. The detection limit ranged from 0.02 to 1.70 mu g/mL and the quantitation limit from 0.07 to 5.1 mu g/mL, with a maximum RSD of 5.24%. Five compounds, rutin, quercetin-3-O-alpha-L-rhamnopyranoside, kaempferol-3-O-alpha-L-rhamnopyranoside, quercetin and kaempferol, were quantified. This method could, therefore, be used for the quality control of hydroethanolic extracts of Copaifera leaves and their cosmetic and pharmaceutical products.
Resumo:
An high performance liquid chromatography (HPLC) method for the enantioselective determination of donepezil (DPZ), 5-O-desmethyl donepezil (5-ODD), and 6-O-desmethyl donepezil (6-ODD) in Czapek culture medium to be applied to biotransformation studies with fungi is described for the first time. The HPLC analysis was carried out using a Chiralpak AD-H column with hexane/ethanol/methanol (75:20:5, v/v/v) plus 0.3 % triethylamine as mobile phase and UV detection at 270 nm. Sample preparation was carried out by liquid-liquid extraction using ethyl acetate as extractor solvent. The method was linear over the concentration range of 100-10,000 ng mL(-1) for each enantiomer of DPZ (r a parts per thousand yenaEuro parts per thousand 0.9985) and of 100-5,000 ng mL(-1) for each enantiomer of 5-ODD (r a parts per thousand yenaEuro parts per thousand 0.9977) and 6-ODD (r a parts per thousand yenaEuro parts per thousand 0.9951). Within-day and between-day precision and accuracy evaluated by relative standard deviations and relative errors, respectively, were lower than 15 % for all analytes. The validated method was used to assess DPZ biotransformation by the fungi Beauveria bassiana American Type Culture Collection (ATCC) 7159 and Cunninghamella elegans ATCC 10028B. Using the fungus B. bassiana ATCC 7159, a predominant formation of (R)-5-ODD was observed while for the fungus C. elegans ATCC 10028B, DPZ was biotransformed to (R)-6-ODD with an enantiomeric excess of 100 %.
Resumo:
Tebuthiuron (TBH) is a herbicide widely used in different cultures and known for its toxic effects. Electrochemical methods are promising for removing pollutants such as pesticides. This study showed the degradation of TBH using a DSA® anode operated at current densities of 50 to 200 mA cm-2. Removal presented pseudo-first order kinetics while high-pressure liquid chromatography (UV detection) showed two peaks, ascribed to degradation intermediates. The maximum percentage of total organic carbon removed was 12.9%. Ion chromatography revealed that higher concentrations of nitrate and nitrite ions formed with increasing current density.
Resumo:
This PhD thesis has been proposed to validate and then apply innovative analytical methodologies for the determination of compounds with harmful impact on human health, such as biogenic amines and ochratoxin A in wines. Therefore, the influence of production technology (pH, amino acids precursor and use of different malolactic starters) on biogenic amines content in wines was evaluated. An HPLC method for simultaneous determination of amino acids and amines with precolumnderivatization with 9-Fluorenyl-methoxycarbonyl chloride (FMOC-Cl) and UV detection was developed. Initially, the influence of pH, time of derivatization, gradient profile were studied. In order to improve the separation of amino acids and amines and reduce the time of analysis, it was decided to study the influence of different flows and the use of different columns in the chromatographic method. Firstly, a C18 Luna column was used and later two monolithic columns Chromolith in series. It appeared to be suitable for an easy, precise and accurate determination of a relatively large number of amino acids and amines in wines. This method was then applied on different wines produced in the Emilia Romagna region. The investigation permitted to discriminate between red and white wines. Amino acids content is related to the winemaking process. Biogenic amines content in these wines does not represent a possible toxicological problem for human health. The results of the study of influence of technologies and wine composition demonstrated that pH of wines and amino acids content are the most important factors. Particularly wines with pH > 3,5 show higher concentration of biogenic amines than wines with lower pH. The enrichment of wines by nutrients also influences the content of some biogenic amines that are higher in wines added with amino acids precursors. In this study, amino acids and biogenic amines are not statistically affected by strain of lactic acid bacteria inoculated as a starter for malolactic fermentation. An evaluation of different clean-up (SPE-MycoSep; IACs and LLE) and determination methods (HPLC and ELISA) of ochratoxin A was carried out. The results obtained proved that the SPE clean-up are reliable at the same level while the LLE procedures shows lowest recovery. The ELISA method gave a lower determination and a low reproducibility than HPLC method.
Resumo:
Therapeutisches Drug Monitoring (TDM) umfasst die Messung von Medikamentenspiegeln im Blut und stellt die Ergebnisse in Zusammenhang mit dem klinischen Erscheinungsbild der Patienten. Dabei wird angenommen, dass die Konzentrationen im Blut besser mit der Wirkung korrelieren als die Dosis. Dies gilt auch für Antidepressiva. Voraussetzung für eine Therapiesteuerung durch TDM ist die Verfügbarkeit valider Messmethoden im Labor und die korrekte Anwendung des Verfahrens in der Klinik. Ziel dieser Arbeit war es, den Einsatz von TDM für die Depressionsbehandlung zu analysieren und zu verbessern. Im ersten Schritt wurde für das neu zugelassene Antidepressivum Duloxetin eine hochleistungsflüssig-chromatographische (HPLC) Methode mit Säulenschaltung und spektrophotometrischer Detektion etabliert und an Patienten für TDM angewandt. Durch Analyse von 280 Patientenproben wurde herausgefunden, dass Duloxetin-Konzentrationen von 60 bis 120 ng/ml mit gutem klinischen Ansprechen und einem geringen Risiko für Nebenwirkungen einhergingen. Bezüglich seines Interaktionspotentials erwies sich Duloxetin im Vergleich zu anderen Antidepressiva als schwacher Inhibitor des Cytochrom P450 (CYP) Isoenzyms 2D6. Es gab keinen Hinweis auf eine klinische Relevanz. Im zweiten Schritt sollte eine Methode entwickelt werden, mit der möglichst viele unterschiedliche Antidepressiva einschließlich deren Metaboliten messbar sind. Dazu wurde eine flüssigchromatographische Methode (HPLC) mit Ultraviolettspektroskopie (UV) entwickelt, mit der die quantitative Analyse von zehn antidepressiven und zusätzlich zwei antipsychotischen Substanzen innerhalb von 25 Minuten mit ausreichender Präzision und Richtigkeit (beide über 85%) und Sensitivität erlaubte. Durch Säulenschaltung war eine automatisierte Analyse von Blutplasma oder –serum möglich. Störende Matrixbestandteile konnten auf einer Vorsäule ohne vorherige Probenaufbereitung abgetrennt werden. Das kosten- und zeiteffektive Verfahren war eine deutliche Verbesserung für die Bewältigung von Proben im Laboralltag und damit für das TDM von Antidepressiva. Durch Analyse des klinischen Einsatzes von TDM wurden eine Reihe von Anwendungsfehlern identifiziert. Es wurde deshalb versucht, die klinische Anwendung des TDM von Antidepressiva durch die Umstellung von einer weitgehend händischen Dokumentation auf eine elektronische Bearbeitungsweise zu verbessern. Im Rahmen der Arbeit wurde untersucht, welchen Effekt man mit dieser Intervention erzielen konnte. Dazu wurde eine Labor-EDV eingeführt, mit der der Prozess vom Probeneingang bis zur Mitteilung der Messergebnisse auf die Stationen elektronisch erfolgte und die Anwendung von TDM vor und nach der Umstellung untersucht. Die Umstellung fand bei den behandelnden Ärzten gute Akzeptanz. Die Labor-EDV erlaubte eine kumulative Befundabfrage und eine Darstellung des Behandlungsverlaufs jedes einzelnen Patienten inklusive vorhergehender Klinikaufenthalte. Auf die Qualität der Anwendung von TDM hatte die Implementierung des Systems jedoch nur einen geringen Einfluss. Viele Anforderungen waren vor und nach der Einführung der EDV unverändert fehlerhaft, z.B. wurden häufig Messungen vor Erreichen des Steady State angefordert. Die Geschwindigkeit der Bearbeitung der Proben war im Vergleich zur vorher händischen Ausführung unverändert, ebenso die Qualität der Analysen bezüglich Richtigkeit und Präzision. Ausgesprochene Empfehlungen hinsichtlich der Dosierungsstrategie der angeforderten Substanzen wurden häufig nicht beachtet. Verkürzt wurde allerdings die mittlere Latenz, mit der eine Dosisanpassung nach Mitteilung des Laborbefundes erfolgte. Insgesamt ist es mit dieser Arbeit gelungen, einen Beitrag zur Verbesserung des Therapeutischen Drug Monitoring von Antidepressiva zu liefern. In der klinischen Anwendung sind allerdings Interventionen notwendig, um Anwendungsfehler beim TDM von Antidepressiva zu minimieren.
Resumo:
CZE coupled to sheath liquid-based electrospray ionization (ESI) and multiple-stage ion trap mass spectrometry (MS(n) ) was used for the confirmation analysis of ethyl glucuronide (EtG) and ethyl sulfate (EtS) in human serum and urine collected after intake of alcoholic beverages. Electrophoretic separations were performed in uncoated fused-silica capillaries using a pH 9.5 ammonium acetate background electrolyte and normal polarity. MS detection of EtG and EtS occurred after negative ionization using a spray liquid containing 0.5% v/v ammonia in isopropanol/water (60:40%, v/v). CZE-MS and CZE-MS² results obtained after injection of solid-phase extracts for EtG and EtS and of diluted urine confirmed the presence of EtG and EtS in samples whose levels were previously determined by CZE with indirect UV detection. Detection limits of each compound were estimated to be around 2.0 (injection of diluted urine) and 0.2 μg/mL (extracts).
Resumo:
A protein of a biological sample is usually quantified by immunological techniques based on antibodies. Mass spectrometry offers alternative approaches that are not dependent on antibody affinity and avidity, protein isoforms, quaternary structures, or steric hindrance of antibody-antigen recognition in case of multiprotein complexes. One approach is the use of stable isotope-labeled internal standards; another is the direct exploitation of mass spectrometric signals recorded by LC-MS/MS analysis of protein digests. Here we assessed the peptide match score summation index based on probabilistic peptide scores calculated by the PHENYX protein identification engine for absolute protein quantification in accordance with the protein abundance index as proposed by Mann and co-workers (Rappsilber, J., Ryder, U., Lamond, A. I., and Mann, M. (2002) Large-scale proteomic analysis of the human spliceosome. Genome Res. 12, 1231-1245). Using synthetic protein mixtures, we demonstrated that this approach works well, although proteins can have different response factors. Applied to high density lipoproteins (HDLs), this new approach compared favorably to alternative protein quantitation methods like UV detection of protein peaks separated by capillary electrophoresis or quantitation of protein spots on SDS-PAGE. We compared the protein composition of a well defined HDL density class isolated from plasma of seven hypercholesterolemia subjects having low or high HDL cholesterol with HDL from nine normolipidemia subjects. The quantitative protein patterns distinguished individuals according to the corresponding concentration and distribution of cholesterol from serum lipid measurements of the same samples and revealed that hypercholesterolemia in unrelated individuals is the result of different deficiencies. The presented approach is complementary to HDL lipid analysis; does not rely on complicated sample treatment, e.g. chemical reactions, or antibodies; and can be used for projective clinical studies of larger patient groups.
Resumo:
La presente tesis fue ideada con el objetivo principal de fabricar y caracterizar fotodiodos Schottky en capas de ZnMgO y en estructuras de pozo cuántico ZnMgO/ZnO para la detección de luz UV. La elección de este material semiconductor vino motivada por la posibilidad que ofrece de detectar y procesar señales simultáneamente, en un amplio margen de longitudes de onda, al igual que su más directo competidor el GaN. En esta memoria se da en primer lugar una visión general de las propiedades estructurales y ópticas del ZnO, prestando especial atención a su ternario ZnMgO y a las estructuras de pozo cuántico ZnMgO/ZnO. Además, se han desarrollado los conocimientos teóricos necesarios para una mejor compresión y discusión de los resultados alcanzados. En lo que respecta a los resultados de esta memoria, en esencia, estos se dividen en dos bloques. Fotodiodos desarrollados sobre capas delgadas de ZnMgO no-polar, y sobre estructuras de pozo cuántico de ZnMgO/ZnO no-polares y semipolares Fotodiodos de capas delgadas de ZnMgO. Es bien conocido que la adición de Mg a la estructura cristalina del ZnO desplaza el borde de absorción hacia energías mayores en el UV. Se ha aprovechado esto para fabricar fotodiodos Schottky sobre capas de ZnMgO crecidas por MOCVD y MBE, los cuales detecten en un ventana de energías comprendida entre 3.3 a 4.6 eV. Sobre las capas de ZnMgO, con diferentes contenidos de Mg(5.6-18.0 %), crecidas por MOCVD se han fabricado fotodiodos Schottky. Se han estudiado en detalle las curvas corrientevoltaje (I-V). Seguidamente, se ha realizado un análisis de la respuesta espectral bajo polarización inversa. Tanto los valores de responsividad obtenidos como el contraste UV/VIS están claramente aumentados por la presencia de ganancia. Paralelamente, se han realizado medidas de espectroscopia de niveles profundos (DLOS), identificándose la presencia de dos niveles profundos de carácter aceptor. El papel desempeñado por estos en la ganancia ha sido analizado meticulosamente. Se ha demostrado que cuando estos son fotoionizados son responsables directos del gran aumento de la corriente túnel que se produce a través de la barrera Schottky, dando lugar a la presencia de la ganancia observada, que además resulta ser función del flujo de fotones incidente. Para extender el rango detección hasta 4.6 eV se fabricaron fotodiodos sobre capas de ZnMgO de altísima calidad cristalina crecidas por MBE. Sobre estos se ha realizado un riguroso análisis de las curvas I-V y de las curvas capacidad-voltaje (CV), para posteriormente identificar los niveles profundos presentes en el material, mediante la técnica de DLOS. Así mismo se ha medido la respuesta espectral de los fotodetectores, la cual muestra un corte abrupto y un altísimo contraste UV/VIS. Además, se ha demostrado como estos son perfectos candidatos para la detección de luz en la región ciega al Sol. Por otra parte, se han fabricado fotodiodos MSM sobre estas mismas capas. Se han estudiado las principales figuras de mérito de estos, observándose unas corrientes bajas de oscuridad, un contraste UV/VIS de 103, y la presencia de fotocorriente persistente. Fotodiodos Schottky de pozos cuánticos de ZnO/ZnMgO. En el segundo bloque de esta memoria, con el objeto final de clarificar el impacto que tiene el tratamiento del H2O2 sobre las características optoelectrónicas de los dispositivos, se ha realizado un estudio detallado, en el que se han analizado por separado fotodiodos tratados y no tratados con H2O2, fabricados sobre pozos cuánticos de ZnMgO/ZnO. Se ha estudiado la respuesta espectral en ambos casos, observándose la presencia de ganancia en los dos. A través de un análisis meticuloso de las características electrónicas y optoeletrónicas de los fotodiodos, se han identificado dos mecanismos de ganancia internos diferentes en función de que la muestra sea tratada o no-tratada. Se han estudiado fotodetectores sensibles a la polarización de la luz (PSPDs) usando estructuras de pozo cuántico no-polares y semipolares sobre sustratos de zafiro y sustratos de ZnO. En lo que respecta a los PSPDs sobre zafiro, en los cuales el pozo presenta una tensión acumulada en el plano, se ha visto que el borde de absorción se desplaza _E _21 meV con respecto a luz linealmente polarizada perpendicular y paralela al eje-c, midiéndose un contraste (RE || c /RE c)max _ 6. Con respecto a los PSPDs crecidos sobre ZnO, los cuales tienen el pozo relajado, se ha obtenido un 4E _30-40, y 21 meV para las heteroestructuras no-polar y semipolar, respectivamente. Además el máximo contraste de responsividad fue de (RE || c /RE c)max _ 6 . Esta sensibilidad a la polarización de la luz ha sido explicada en términos de las transiciones excitónicas entre la banda de conducción y las tres bandas de valencia. ABSTRACT The main goal of the present thesis is the fabrication and characterization of Schottky photodiodes based on ZnMgO layers and ZnMgO / ZnO quantum wells (QWs) for the UV detection. The decision of choosing this semiconductor was mainly motivated by the possibility it offers of detecting and processing signals simultaneously in a wide range of wavelengths like its main competitor GaN. A general overview about the structural and optical properties of ZnO, ZnMgO layers and ZnMgO/ZnO QWs is given in the first part of this thesis. Besides, it is shown the necessary theoretical knowledge for a better understanding of the discussion presented here. The results of this thesis may be divided in two parts. On the one hand, the first part is based on studying non-polar ZnMgO photodiodes. On the other hand, the second part is focused on the characterization of non-polar and semipolar ZnMgO / ZnO QWs Schottky photodiodes. ZnMgO photodiodes. It is well known that the addition of Mg in the crystal structure of ZnO results in a strong blue-shift of the ZnO band-gap. Taking into account this fact Schottky photodiodes were fabricated on ZnMgO layers grown by MOCVD and MBE. Concerning ZnMgO layers grown by MOCVD, a series of Schottky photodiodes were fabricated, by varying the Mg content from 5.6% to 18 %. Firstly, it has been studied in detail the current-voltage curves. Subsequently, spectral response was analyzed at reverse bias voltage. Both the rejection ratio and the responsivity are shown to be largely enhanced by the presence of an internal gain mechanism. Simultaneously, measurements of deep level optical spectroscopy were carried out, identifying the presence of two acceptor-like deep levels. The role played for these in the gain observed was studied in detail. It has been demonstrated that when these are photoionized cause a large increase in the tunnel current through the Schottky barrier, yielding internal gains that are a function of the incident photon flux. In order to extend the detection range up to 4.6 eV, photodiodes ZnMgO grown by MBE were fabricated. An exhaustive analysis of the both I-V and CV characteristics was performed. Once again, deep levels were identified by using the technique DLOS. Furthermore, the spectral response was measured, observing sharp absorption edges and high UV/VIS rejections ratio. The results obtained have confirmed these photodiodes are excellent candidates for the light detection in the solar-blind region. In addition, MSM photodiodes have also been fabricated on the same layers. The main figures of merit have been studied, showing low dark currents, a large UV/VIS rejection ratio and persistent photocurrent. ZnMgO/ZnO QWs photodiodes. The second part was focused on ZnMgO/ ZnO QWs. In order to clarify the impact of the H2O2 treatment on the performance of the Schottky diodes, a comparative study using treated and untreated ZnMgO/ZnO photodiodes has been carried out. The spectral response in both cases has shown the presence of gain, under reverse bias. Finally, by means of the analysis of electronic and optoelectronic characteristics, two different internal gain mechanisms have been indentified in treated and non-treated material. Light polarization-sensitive UV photodetectors (PSPDs) using non-polar and semipolar ZnMgO/ZnO multiple quantum wells grown both on sapphire and ZnO substrates have been demonstrated. For the PSPDs grown on sapphire with anisotropic biaxial in-plain strain, the responsivity absorption edge shifts by _E _21 meV between light polarized perpendicular and parallel to the c-axis, and the maximum responsivity contrast is (RE || c /RE c)max _ 6 . For the PSPDs grown on ZnO, with strain-free quantum wells, 4E _30-40, and 21 meV for non-polar and semipolar heterostructures, and maximum (R /R||)max _10. for non-polar heterostructure was achieved. These light polarization sensitivities have been explained in terms of the excitonic transitions between the conduction and the three valence bands.
Resumo:
Biogenic amines were determined in Australian by-product meals including fish meals, poultry meals, meat meals, feather meals and blood meals. They were extracted with 0.1 mol/L HCl, derivatised with dansyl chloride and analysed using HPLC with UV detection at 254 nm. Median levels of putrescine, cadaverine and histamine were determined in the by-product meals, with the ranges being 13-102 mg/kg, 7-220 mg/kg and 4-570 mg/kg, respectively. High levels of biogenic amines were found particularly in fish meals. The results indicate that further studies are required to determine the maximum limits for biogenic amines in by-product meals that will not impair production when fed to poultry.
Resumo:
A simple method for the measurement of the active leflunomide metabolite A77 1726 in human plasma by HPLC is presented. The sample workup was simple, using acetonitrile for protein precipitation. Chromatographic separation of A77 1726 and the internal standard, alpha-phenylcinnamic acid, was achieved using a C-18 column with UV detection at 305 nm. The assay displayed reproducible linearity for A77 1726 with determination coefficients (r(2)) > 0.997 over the concentration range 0.5-60.0 mug/ml. The reproducibility (%CV) for intra- and inter-day assays of spiked controls was
Resumo:
Purpose: The use of PHMB as a disinfectant in contact lens multipurpose solutions has been at the centre of much debate in recent times, particularly in relation to the issue of solution induced corneal staining. Clinical studies have been carried out which suggest different effects with individual contact lens materials used in combination with specific PHMB containing care regimes. There does not appear to be, however, a reliable analytical technique that would detect and quantify with any degree of accuracy the specific levels of PHMB that are taken up and released from individual solutions by the various contact lens materials. Methods: PHMB is a mixture of positively charged polymer units of varying molecular weight that has maximum absorbance wavelength of 236 nm. On the basis of these properties a range of assays including capillary electrophoresis, HPLC, a nickelnioxime colorimetric technique, mass spectrophotometry, UV spectroscopy and ion chromatography were assessed paying particular attention to each of their constraints and detection levels. Particular interest was focused on the relative advantage of contactless conductivity compared to UV and mass spectrometry detection in capillary electrophoresis (CE). This study provides an overview of the comparative performance of these techniques. Results: The UV absorbance of PHMB solutions, ranging from 0.0625 to 50 ppm was measured at 236 nm. Within this range the calibration curve appears to be linear however, absorption values below 1 ppm (0.0001%) were extremely difficult to reproduce. The concentration of PHMB in solutions is in the range of 0.0002–0.00005% and our investigations suggest that levels of PHMB below 0.0001% (levels encountered in uptake and release studies) can not be accurately estimated, in particular when analysing complex lens care solutions which can contain competitively absorbing, and thus interfering, species in the solution. The use of separative methodologies, such as CE using UV detection alone is similarly limited. Alternative techniques including contactless conductivity detection offer greater discrimination in complex solutions together with the opportunity for dual channel detection. Preliminary results achieved by TraceDec1 contactless conductivity detection, (Gain 150%, Offset 150) in conjunction with the Agilent capillary electrophoresis system using a bare fused silica capillary (extended light path, 50 mid, total length 64.5 cm, effective length 56 cm) and a cationic buffer at pH 3.2, exhibit great potential with reproducible PHMB split peaks. Conclusions: PHMB-based solutions are commonly associated with the potential to invoke corneal staining in combination with certain contact lens materials. However this terminology ‘PHMBbased solution’ is used primarily because PHMB itself has yet to be adequately implicated as the causative agent of the staining and compromised corneal cell integrity. The lack of well characterised adequately sensitive assays, coupled with the range of additional components that characterise individual care solutions pose a major barrier to the investigation of PHMB interactions in the lenswearing eye.
Resumo:
La circulation extracorporelle (CEC) est une technique utilisée en chirurgie cardiaque effectuée des milliers de fois chaque jour à travers le monde. L’instabilité hémodynamique associée au sevrage de la CEC difficile constitue la principale cause de mortalité en chirurgie cardiaque et l’hypertension pulmonaire (HP) a été identifiée comme un des facteurs de risque les plus importants. Récemment, une hypothèse a été émise suggérant que l'administration prophylactique (avant la CEC) de la milrinone par inhalation puisse avoir un effet préventif et faciliter le sevrage de la CEC chez les patients atteints d’HP. Toutefois, cette indication et voie d'administration pour la milrinone n'ont pas encore été approuvées par les organismes réglementaires. Jusqu'à présent, la recherche clinique sur la milrinone inhalée s’est principalement concentrée sur l’efficacité hémodynamique et l'innocuité chez les patients cardiaques, bien qu’aucun biomarqueur n’ait encore été établi. La dose la plus appropriée pour l’administration par nébulisation n'a pas été déterminée, de même que la caractérisation des profils pharmacocinétiques (PK) et pharmacodynamiques (PD) suite à l'inhalation. L'objectif de notre recherche consistait à caractériser la relation exposition-réponse de la milrinone inhalée administrée chez les patients subissant une chirurgie cardiaque sous CEC. Une méthode analytique par chromatographie liquide à haute performance couplée à un détecteur ultraviolet (HPLC-UV) a été optimisée et validée pour le dosage de la milrinone plasmatique suite à l’inhalation et s’est avérée sensible et précise. La limite de quantification (LLOQ) était de 1.25 ng/ml avec des valeurs de précision intra- et inter-dosage moyennes (CV%) <8%. Des patients souffrant d’HP pour lesquels une chirurgie cardiaque sous CEC était prévue ont d’abord été recrutés pour une étude pilote (n=12) et, par la suite, pour une étude à plus grande échelle (n=28) où la milrinone (5 mg) était administrée par inhalation pré-CEC. Dans l'étude pilote, nous avons comparé l'exposition systémique de la milrinone peu après son administration avec un nébuliseur pneumatique ou un nébuliseur à tamis vibrant. L’efficacité des nébuliseurs en termes de dose émise et dose inhalée a également été déterminée in vitro. Dans l'étude à plus grande échelle conduite en utilisant exclusivement le nébuliseur à tamis vibrant, la dose inhalée in vivo a été estimée et le profil pharmacocinétique de la milrinone inhalée a été pleinement caractérisé aux niveaux plasmatique et urinaire. Le ratio de la pression artérielle moyenne sur la pression artérielle pulmonaire moyenne (PAm/PAPm) a été choisi comme biomarqueur PD. La relation exposition-réponse de la milrinone a été caractérisée pendant la période d'inhalation en étudiant la relation entre l'aire sous la courbe de l’effet (ASCE) et l’aire sous la courbe des concentrations plasmatiques (ASC) de chacun des patients. Enfin, le ratio PAm/PAPm a été exploré comme un prédicteur potentiel de sortie de CEC difficile dans un modèle de régression logistique. Les expériences in vitro ont démontré que les doses émises étaient similaires pour les nébuliseurs pneumatique (64%) et à tamis vibrant (68%). Cependant, la dose inhalée était 2-3 fois supérieure (46% vs 17%) avec le nébuliseur à tamis vibrant, et ce, en accord avec les concentrations plasmatiques. Chez les patients, en raison des variations au niveau des facteurs liés au circuit et au ventilateur causant une plus grande dose expirée, la dose inhalée a été estimée inférieure (30%) et cela a été confirmé après récupération de la dose de milrinone dans l'urine 24 h (26%). Les concentrations plasmatiques maximales (Cmax: 41-189 ng/ml) et l'ampleur de la réponse maximale ΔRmax-R0 (0-65%) ont été observées à la fin de l'inhalation (10-30 min). Les données obtenues suite aux analyses PK sont en accord avec les données publiées pour la milrinone intraveineuse. Après la période d'inhalation, les ASCE individuelles étaient directement reliées aux ASC (P=0.045). Enfin, notre biomarqueur PD ainsi que la durée de CEC ont été identifiés comme des prédicteurs significatifs de la sortie de CEC difficile. La comparaison des ASC et ASCE correspondantes a fourni des données préliminaires supportant une preuve de concept pour l'utilisation du ratio PAm/PAPm comme biomarqueur PD prometteur et justifie de futures études PK/PD. Nous avons pu démontrer que la variation du ratio PAm/PAPm en réponse à la milrinone inhalée contribue à la prévention de la sortie de CEC difficile.
Resumo:
The thesis aims to exploit properties of thin films for applications such as spintronics, UV detection and gas sensing. Nanoscale thin films devices have myriad advantages and compatibility with Si-based integrated circuits processes. Two distinct classes of material systems are investigated, namely ferromagnetic thin films and semiconductor oxides. To aid the designing of devices, the surface properties of the thin films were investigated by using electron and photon characterization techniques including Auger electron spectroscopy (AES), X-ray photoelectron spectroscopy (XPS), grazing incidence X-ray diffraction (GIXRD), and energy-dispersive X-ray spectroscopy (EDS). These are complemented by nanometer resolved local proximal probes such as atomic force microscopy (AFM), magnetic force microscopy (MFM), electric force microscopy (EFM), and scanning tunneling microscopy to elucidate the interplay between stoichiometry, morphology, chemical states, crystallization, magnetism, optical transparency, and electronic properties. Specifically, I studied the effect of annealing on the surface stoichiometry of the CoFeB/Cu system by in-situ AES and discovered that magnetic nanoparticles with controllable areal density can be produced. This is a good alternative for producing nanoparticles using a maskless process. Additionally, I studied the behavior of magnetic domain walls of the low coercivity alloy CoFeB patterned nanowires. MFM measurement with the in-plane magnetic field showed that, compared to their permalloy counterparts, CoFeB nanowires require a much smaller magnetization switching field , making them promising for low-power-consumption domain wall motion based devices. With oxides, I studied CuO nanoparticles on SnO2 based UV photodetectors (PDs), and discovered that they promote the responsivity by facilitating charge transfer with the formed nanoheterojunctions. I also demonstrated UV PDs with spectrally tunable photoresponse with the bandgap engineered ZnMgO. The bandgap of the alloyed ZnMgO thin films was tailored by varying the Mg contents and AES was demonstrated as a surface scientific approach to assess the alloying of ZnMgO. With gas sensors, I discovered the rf-sputtered anatase-TiO2 thin films for a selective and sensitive NO2 detection at room temperature, under UV illumination. The implementation of UV enhances the responsivity, response and recovery rate of the TiO2 sensor towards NO2 significantly. Evident from the high resolution XPS and AFM studies, the surface contamination and morphology of the thin films degrade the gas sensing response. I also demonstrated that surface additive metal nanoparticles on thin films can improve the response and the selectivity of oxide based sensors. I employed nanometer-scale scanning probe microscopy to study a novel gas senor scheme consisting of gallium nitride (GaN) nanowires with functionalizing oxides layer. The results suggested that AFM together with EFM is capable of discriminating low-conductive materials at the nanoscale, providing a nondestructive method to quantitatively relate sensing response to the surface morphology.
Resumo:
La circulation extracorporelle (CEC) est une technique utilisée en chirurgie cardiaque effectuée des milliers de fois chaque jour à travers le monde. L’instabilité hémodynamique associée au sevrage de la CEC difficile constitue la principale cause de mortalité en chirurgie cardiaque et l’hypertension pulmonaire (HP) a été identifiée comme un des facteurs de risque les plus importants. Récemment, une hypothèse a été émise suggérant que l'administration prophylactique (avant la CEC) de la milrinone par inhalation puisse avoir un effet préventif et faciliter le sevrage de la CEC chez les patients atteints d’HP. Toutefois, cette indication et voie d'administration pour la milrinone n'ont pas encore été approuvées par les organismes réglementaires. Jusqu'à présent, la recherche clinique sur la milrinone inhalée s’est principalement concentrée sur l’efficacité hémodynamique et l'innocuité chez les patients cardiaques, bien qu’aucun biomarqueur n’ait encore été établi. La dose la plus appropriée pour l’administration par nébulisation n'a pas été déterminée, de même que la caractérisation des profils pharmacocinétiques (PK) et pharmacodynamiques (PD) suite à l'inhalation. L'objectif de notre recherche consistait à caractériser la relation exposition-réponse de la milrinone inhalée administrée chez les patients subissant une chirurgie cardiaque sous CEC. Une méthode analytique par chromatographie liquide à haute performance couplée à un détecteur ultraviolet (HPLC-UV) a été optimisée et validée pour le dosage de la milrinone plasmatique suite à l’inhalation et s’est avérée sensible et précise. La limite de quantification (LLOQ) était de 1.25 ng/ml avec des valeurs de précision intra- et inter-dosage moyennes (CV%) <8%. Des patients souffrant d’HP pour lesquels une chirurgie cardiaque sous CEC était prévue ont d’abord été recrutés pour une étude pilote (n=12) et, par la suite, pour une étude à plus grande échelle (n=28) où la milrinone (5 mg) était administrée par inhalation pré-CEC. Dans l'étude pilote, nous avons comparé l'exposition systémique de la milrinone peu après son administration avec un nébuliseur pneumatique ou un nébuliseur à tamis vibrant. L’efficacité des nébuliseurs en termes de dose émise et dose inhalée a également été déterminée in vitro. Dans l'étude à plus grande échelle conduite en utilisant exclusivement le nébuliseur à tamis vibrant, la dose inhalée in vivo a été estimée et le profil pharmacocinétique de la milrinone inhalée a été pleinement caractérisé aux niveaux plasmatique et urinaire. Le ratio de la pression artérielle moyenne sur la pression artérielle pulmonaire moyenne (PAm/PAPm) a été choisi comme biomarqueur PD. La relation exposition-réponse de la milrinone a été caractérisée pendant la période d'inhalation en étudiant la relation entre l'aire sous la courbe de l’effet (ASCE) et l’aire sous la courbe des concentrations plasmatiques (ASC) de chacun des patients. Enfin, le ratio PAm/PAPm a été exploré comme un prédicteur potentiel de sortie de CEC difficile dans un modèle de régression logistique. Les expériences in vitro ont démontré que les doses émises étaient similaires pour les nébuliseurs pneumatique (64%) et à tamis vibrant (68%). Cependant, la dose inhalée était 2-3 fois supérieure (46% vs 17%) avec le nébuliseur à tamis vibrant, et ce, en accord avec les concentrations plasmatiques. Chez les patients, en raison des variations au niveau des facteurs liés au circuit et au ventilateur causant une plus grande dose expirée, la dose inhalée a été estimée inférieure (30%) et cela a été confirmé après récupération de la dose de milrinone dans l'urine 24 h (26%). Les concentrations plasmatiques maximales (Cmax: 41-189 ng/ml) et l'ampleur de la réponse maximale ΔRmax-R0 (0-65%) ont été observées à la fin de l'inhalation (10-30 min). Les données obtenues suite aux analyses PK sont en accord avec les données publiées pour la milrinone intraveineuse. Après la période d'inhalation, les ASCE individuelles étaient directement reliées aux ASC (P=0.045). Enfin, notre biomarqueur PD ainsi que la durée de CEC ont été identifiés comme des prédicteurs significatifs de la sortie de CEC difficile. La comparaison des ASC et ASCE correspondantes a fourni des données préliminaires supportant une preuve de concept pour l'utilisation du ratio PAm/PAPm comme biomarqueur PD prometteur et justifie de futures études PK/PD. Nous avons pu démontrer que la variation du ratio PAm/PAPm en réponse à la milrinone inhalée contribue à la prévention de la sortie de CEC difficile.