1000 resultados para Tolerância a baixas temperaturas


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Os granodioritos Água Azul (GrdAA) e Água Limpa (GrdAL) afloram no extremo sul do Domínio Carajás como dois corpos alongados segundo o trend regional E-W, anteriormente inseridos no Complexo Xingu. O GrdAL é formado essencialmente por biotita-anfibólio granodioritos e muscovita-biotita granodioritos, além de anfibólio-biotita tonalitos subordinados; no GrdAA, epídoto-anfibólio-biotita granodioritos são dominantes, epídoto-anfibólio-biotita tonalitos e (anfibólio)-epídoto-biotita monzogranitos, subordinados. Essas rochas mostram assinaturas geoquímicas afins dos sanukitoides arqueanos. O estudo de suscetibilidade magnética (SM) mostrou valores relativamente baixos para o GrdAL (média de 17,54 × 10-4 SIv) e o GrdAA (média de 4,19 × 10-4 SIv). Os estudos dos minerais opacos mostram que a magnetita e a hematita são as fases comuns e que a ilmenita está ausente nessas rochas. O GrdAL contém titanita associada à magnetita, enquanto o GrdAA contém pirita, calcopirita e goethita. No GrdAL, a magnetita é mais abundante e desenvolvida que no GrdAA, justificando, assim, sua SM mais elevada. A martitização da magnetita e a oxidação dos sulfetos, gerando goethita, ocorreram a baixas temperaturas. A correlação positiva entre os valores de SM e os conteúdos modais de opacos, anfibólio, epídoto + allanita e quartzo + K-feldspato, assim como a correlação negativa de SM com biotita e máficos observadas nessas unidades, denunciam uma tendência no aumento de SM no sentido anfibólio tonalitos/anfibólio granodioritos à biotita granodioritos/biotita monzogranitos. Os dados geoquímicos corroboram esse comportamento, com correlação negativa entre os valores de SM e Fe2O3T, FeO e MgO, refletindo para as duas unidades uma tendência de aumento nos valores de SM paralelamente à diferenciação magmática. As afinidades geoquímicas e mineralógicas entre essas rochas e os sanukitoides do Domínio Rio Maria sugerem condições de fugacidade de oxigênio entre os tampões HM e FMQ para os granitoides estudados.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Ciências Biológicas (Botânica) - IBB

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The Tahiti lime appears very susceptible to attack by post-harvest diseases, primarily by the fungi Penicillium and Phomopsis, and also because of its high sensitivity to storage at low temperatures. In order to reduce such damage, the present study aimed to verify the efficiency of heat treatment and disinfection of pathogens in the prevention of post-harvest chilling injury of this cultivar and to compare this treatment with other products using the conventional fungicides. The heat treatments were studied with hot-water temperatures ranging between 48 and 56° C. Water at room temperature was used as a control treatment. After treatment, the fruits were kept under cold temperature at 10° C and RH 90% for about 45 days. For comparison, three other treatments were carried out simultaneously, one using imazalil, one with baking soda, and a third with sodium carbonate, these three products being applied by baths in cold water. Two groups of fruit were evaluated, one treated by immersion considering pathogens coming from the field and another by inoculation with spores of the previously isolated pathogens. For the evaluation of physical and chemical parameters of fruits, determinations were made of the skin color, texture, weight loss, size, juice yield, soluble solids, total acidity and vitamin C content. The determination of the sensitivity of the fruit to cold was made by their exposure at temperatures inducing cold damage. The design was a randomized block design with nine treatments, analyzed by the Statgraphics statistical package. Heat treatments, especially at 52° C, were shown to be more promising in the control of pathogenic fungi and cold damage, surpassing the conventional fungicides. No changes were found in the intrinsic and extrinsic parameters in relation to the application of the different treatments.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Agronomia (Genética e Melhoramento de Plantas) - FCAV

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia Animal - FEIS

Relevância:

80.00% 80.00%

Publicador:

Resumo:

On the grounds of the great advances achieved over recent years, the process HF/ERW (High-Frequency/Electric Resistance Welding)welded pipe have played an active role in the oil and gas industry for deep water applications, at high and extremely low temperatures, under high pressure and in highly corrosive environments, gradually replacing manufactured pipes by other processes. However, studies have shown that defects in the welded joints are a the leading causes of pipelines failures, which has required the determination of toughness values in this region, in compliance with the strict recommendations of the codes and standards with manufacturers and construction companies, on the oil and gas sector. As part of the validation process required toughness values, this research project focuses on a microstructural analysis in HF / ERW tubes microalloyed, steel grade API 5CT P110, designed to explore oil and gas in deep waters, the subject of strategic relevance to the country because of the recent discoveries in the Santos mega fields: Tupi and Libra (pre-salt). In this scientific work will be presented and discussed the results of mechanical tensile and Charpy, a few CTOD tests curves (showing the trend of toughness values to be obtained), and the microstructures of the base material obtained by optical microscopy, with special emphasis on the formation of nonmetallic inclusions in the welded joint

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In engineering, for correct designing the structural components required for cyclical stresses, it is necessary to determine a limit of resistance to fatigue, which is the maximum amplitude of the applied tension under which the fatigue failure does not occurs after a certain number cycles. The marine environment is hostile, not only by the high pressure, corrosion, but also by low temperatures. Petrol Production units, composed of the risers (pipelines connecting the oil well to the ship), are dimensioned to remain installed for periods of 20 up to 30 years, and must therefore be prepared to support various efforts, such as tidal, wind currents and everything that is related. This paper focuses on a study on the fatigue behavior of microalloyed steel, API 5L Grade X70, used to transport oil and gas by pipelines. For analysis, we obtained the curves S-N (stress vs. number of cycles) using laboratory data collected from cylindrical longitudinal and transverse specimens used in axial fatigue test in accordance with ASTM E466. The tensile tests and microhardness were performed to characterize the mechanical properties of the samples, and it was found that the values meet the specifications of the standard API 5L. To characterize microstructurally the material, it was also made a metallographic analysis of the steel under study, and the origin of the fatigue crack was investigated with the support of a scanning electron microscope (SEM).

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work aims to synthesize the manganese and zinc ferrite, by the polymeric precursor method, in order to obtain materials with appropriate characteristics for the application in medical diagnosis techniques. The manganese and zinc ferrite powders with the composition of Mn(1-x)ZnxFe2O4, where x=0,23, were prepared and calcined in air at different times and temperatures. The X-ray diffraction (XRD) data show that the sample calcined at 400°C crystallize as ferrite (monophase), but in an inverted spinel structure (high content of iron occupying manganese tetrahedral site and manganese occupying the iron octahedral site). The samples calcined at temperatures between 600°C and 900°C shows the secondary phase of hematite and the sample calcined at 1100oC shows to be monophase in ferrite with normal spinel structure. The monophase powders of ferrite showed a reduction in the surface area and an increasing in the pore size for higher calcination temperatures. The magnetic analysis show that the sample calcined at 400°C presents satisfactory magnetization at room temperature, however, it behaves as diamagnetic material at low temperatures (10K). The powder containing hematite, without the partial substitution of iron ions by manganese, showed to have low transition temperature, and consequently low magnetization at room temperature. The hematite, when partially substituted, provides materials with irregular magnetization at the saturation region. The powder calcined at 1100°C shows high magnetization either at room temperature or low temperature (10K)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The conservation of raw milk for long periods of time under refrigeration can result in the lost of its quality. This happens because bacterias, capable of developing in low temperatures, as psichrotrophics, in milk, associates with its enzymatic activities, are capable to degradate it. Although the pasteurization of milk sufficiently diminishes the transmission of the illnesses, that generally eliminates such microorganisms, is not a total efficient process because many enzymes produced for such bacterias are termostable, being able to resist the treatment and to remain active, leading to the loss of the quality of milk and its derivatives. The Normative Instruction 51 of 2002 established that milk must be cooled and stored in the production property, what resulted increasing the incidence of such bacteria in population destined milk. In some parts of the world contaminated milk is causing serious risks to the health of the population, assuming great importance in Public Health, mainly in relation to the hygienic-sanitary conditions of the product. ANVISA establishes, thus, maximum bacteriological concentration that must be evidenced before commercializing the product, guaranteeing the quality of milk as proper for consumption. Based on these aspects, the objective of this work is the microbiological analysis of 30 milk samples type C, collected in bakeries of the city Botucatu, in the state of São Paulo. Analysis were made to determinate the most likely number of termotolerants coliforms, as well the number of colony units of psichrotrophics bacterias, the presence of Salmonella and the enumeration of positive Staphylococcus aureus, at the moment of purchase and validity of the products

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

On the grounds of the great advances achieved over recent years, the process HF/ERW (High-Frequency/Electric Resistance Welding)welded pipe have played an active role in the oil and gas industry for deep water applications, at high and extremely low temperatures, under high pressure and in highly corrosive environments, gradually replacing manufactured pipes by other processes. However, studies have shown that defects in the welded joints are a the leading causes of pipelines failures, which has required the determination of toughness values in this region, in compliance with the strict recommendations of the codes and standards with manufacturers and construction companies, on the oil and gas sector. As part of the validation process required toughness values, this research project focuses on a microstructural analysis in HF / ERW tubes microalloyed, steel grade API 5CT N80, designed to explore oil and gas in deep waters, the subject of strategic relevance to the country because of the recent discoveries in the Santos mega fields: Tupi and Libra (pre-salt). In this scientific work will be presented and discussed the results of mechanical tensile and Charpy, a few CTOD tests curves (showing the trend of toughness values to be obtained), and the microstructures of the base material obtained by optical microscopy, with special emphasis on the formation of non-metallic inclusions in the welded joint

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This work focuses on a study on the fatigue behavior of a microalloyed steel API 5L X70, used in pipes lines to transport oil and gas. These types of steels have excellent mechanical resistance values and ductility and therefore increased their study driven by increased demand for oil and especially natural gas, which consequently raises the need to build new pipelines to transport these products. The oil extraction units, composed of the risers (pipelines connecting the oil well to the ship), are dimensioned to remain installed for periods of 20 to 30 years in the marine environment, a hostile environment for high pressure, corrosion, low temperatures and the stresses caused by the movement of water and tides. For analysis, the S-N (stress versus number of cycles) curves were obtained from data collected from bodies-of-proof cylindrical longitudinal, transverse and that one removed from the weld area of the pipe, tested in accordance with ASTM E466. Tensile tests were performed for characterizing the mechanical properties of the samples and welded joints, concluded that the values meet the specifications of the standard API 5L. To characterize microstructural material, also metallographic analysis was made of regions of the base metal and the HAZ. The results of fatigue tests demonstrated a higher life for the specimens removed from the longitudinal direction the pipe, followed by those in the transverse direction and, finally, the welded joint. The origins of the fatigue cracks were determined by scanning electron microscopy (SEM)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia Animal - FEIS