638 resultados para Titânio poroso
Resumo:
By means of tensile strength, NiCr total crowns were removed from machine-made conical abutments composed by an Ti-6Al-4V alloy. In a total of 20 abutments, 10 were used with it surface presenting high smoothness and 10 abutments had its surfaces modifi ed by laser both cemented with zinc phosphate. The mechanical test was performed at a MTS 810 universal machine adjusted to a speed of 0.5 mm/m. The statistical analysis was done by Levene’s test, which showed homogeneity of variances among groups (F =2.21; p < 0.1). “Student t test” showed that signifi cant differences were found between groups. The modifi cation of the abutment surface through laser caused an increase in pull-out resistance of crowns cemented with zinc phosphate from 430.66 N to 1.514,87 N.
Resumo:
In this work of tensile strength was evaluated the efficacy of 4 cements (S. S. White zinc phoshate, Ketac Cem Easymix glass ionomer, RelyX Luting 2 composite resin/glass ionomer and Panavia 21 TC special acrylic resin) used to fix NiCr crowns to usinated titanium alloy abutments. Were used 40 abutments distributed in groups of 10 elements, to each material. The mechanical essays were developed at a MTS 810 universal machine, adjusted to a 0.5 mm/m velocity. The ANOVA applied to data pointed out the existence of significant differences between groups; the subsequent Tukey´s test (p<0.05) also detected significant differences, except at comparisons of phosphate versus RelyX and phosphate versus Ketac Cem. The better performance was presented by Panavia 21 (1,127.996 N); RelyX (478.197 N) showed itself similar only to phosphate (430.662 N), wich had a performance similar to that of Ketac Cem (227.705 N).
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Pós-graduação em Engenharia Mecânica - FEIS
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
Pós-graduação em Ciência dos Materiais - FEIS
Resumo:
Neste trabalho investigou-se a modificação de superfície do titânio pela irradiação com feixe de Laser Nd:YAG. Os parâmetros do laser como a potência, o comprimento de onda, a frequência, a velocidade de varredura e a área de exposição foram mantidos constantes, exceto o espaçamento da matriz, o qual foi de 0,01 e 0,02 mm. A caracterização da superfície foi realizada por Microscopia Eletrônica de Varredura (MEV) e Difração de Raios X (DRX), sendo que os espectros foram refinados pelo método Rietveld. Pela análise de MEV, observou-se uma mudança na topografia, obtendo uma superfície rugosa produzida pelo fenômeno de ablação. As análises por Rietveld dos espectros de difração de raios X detectaram TiN, Ti2N, TiO2 (anatásio e rutilo), sendo que a amostra com espaçamento 0,01 mm apresentou uma maior quantidade de óxidos e nitretos. Isso pode ser devido à sobreposição do feixe, induzindo à formação de uma superfície com maior estabilidade termodinâmica. Os óxidos e nitretos obtidos são de grande importância, pois são responsáveis por produzir uma maior interação entre o osso-implante.
Resumo:
There is little information regarding bond strengths of polyglass to metal alloys. This study evaluated the influence of bonding system on shear bond strength of a composite resin (Artglass/Heraeus Kulzer) to cast titanium (Ti). Twenty metallic structures (4mm in diameter, 5mm thick) of titanium grade I were cast shaped and abraded with 250mm aluminum oxide and separated into two groups. For each group was applied one bonding system (Siloc or Retention Flow) before opaque and dentin polymer superposition. This procedure was managed using teflon matrices. They were manipulated and polymerized according to the manufacturer's recommendations. The samples were stored in distilled water for 24 hours at 37º and thermocycled (5º and 55ºC/500 cycles). Shear bond strength tests were performed by using an Instron Universal testing machine at a crosshead speed of 5mm/min. Results were analyzed statistically with one-way ANOVA (a=0,5) and they indicated that the Retention Flow system was statistically better than Siloc (20.74 MPa and 11.65 MPa , respectively). It was possible to conclude that the bonding agent influenced the adhesion between polymer and cast titanium.
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
Studies have reported that alcohol may lead to imbalance in bone formation and resorption, however, its effects on osseointegration of titanium implants continues to be an inconclusive subject. In this context, the aim of this study was to make a biomechanical evaluation of the effect of abusive alcohol consumption on the removal torque of osseointegrated titanium implants. Male Wistar rats (n=30) were divided into two experimental groups (15 each) receiving only water (Control) or 36% alcohol solution oral administration. Thirty days later, all animals were submitted to titanium implant (2.2 mm x 4 mm) placement in the right and left tibiae. The surgical alveoli were prepared with a 2 mm drill mounted in a counter-angle hand-piece (20:1 ratio, 35 Ncm torque at 1200 rpm) under abundant cooling. Five animals from each group were euthanized at 15, 30, and 60 days. Tibiae were submitted to reverse torque analysis. Data obtained were submitted to statistical analysis by the non-parametric Kruskal-Wallis and Dunn Tests (p < 0.05). Animals in the alcohol group presented lower removal torque values when compared with control group animals for all periods tested (p < 0.05). It can be concluded that abusive alcohol consumption can reduce the removal torque of titanium implants placed in rat tibiae, suggesting that alcohol may interfere in the osseointegration process of titanium implants.
Resumo:
Studies have reported that alcohol may lead to imbalance in bone formation and resorption, however, its effects on osseointegration of titanium implants continues to be an inconclusive subject. In this context, the aim of this study was to make a biomechanical evaluation of the effect of abusive alcohol consumption on the removal torque of osseointegrated titanium implants. Male Wistar rats (n=30) were divided into two experimental groups (15 each) receiving only water (Control) or 36% alcohol solution oral administration. Thirty days later, all animals were submitted to titanium implant (2.2 mm x 4 mm) placement in the right and left tibiae. The surgical alveoli were prepared with a 2 mm drill mounted in a counter-angle hand-piece (20:1 ratio, 35 Ncm torque at 1200 rpm) under abundant cooling. Five animals from each group were euthanized at 15, 30, and 60 days. Tibiae were submitted to reverse torque analysis. Data obtained were submitted to statistical analysis by the non-parametric Kruskal-Wallis and Dunn Tests (p < 0.05). Animals in the alcohol group presented lower removal torque values when compared with control group animals for all periods tested (p < 0.05). It can be concluded that abusive alcohol consumption can reduce the removal torque of titanium implants placed in rat tibiae, suggesting that alcohol may interfere in the osseointegration process of titanium implants.
Resumo:
Titanium dental implants have been common practice in the dental office, which can increases the number of allergic reactions to this material. Objectives: to alert dental surgeons and specialists of this possible phenomenon through a literature review. Material and methods: an electronic search at PubMed was performed with the keywords “dental implants”, “titanium”, and “allergy” from January 1990 to May 2013. Only articles published in the English language were included. Letters to editor were excluded. Results: from the 22 initially retrieved articles, only 7 were included, being 4 clinical case reports and 3 experimental studies. For clinical cases, the reactions included edema, erythema, exfoliative cheilitis, and eczema. Regarding experimental studies, skin rash and dermatitis were reported. A patch test was not used in two clinical reports. Only one study used histological analysis to attest the lack of allergic reactions. Conclusion: within the limits of the available literature, allergic reactions to titanium dental implants are extremely rare and seem to be related to the female gender. More controlled clinical studies are necessary to elucidate this question.
Resumo:
Introduction: As a new alternative in the complementary treatment lasers teem different systems were employed in the decontamination of dental surfaces implants however, some systems have caused significant changes in its surface. Purpose: Analyze by Scanning Electron Microscopy (SEM) the effects of laser irradiation of Er,Cr: YSGG on different surfaces of titanium. Material and method: Study of 20 titanium discs, and 10 Machined Surface (MS) and 10 surfaces treated with acid (AC). The 10 discs with the same treatment were divided into two groups with five units each, the irradiation was performed in powers of 1 W and 2 W. Result: Showed that the irradiation with 1 W of power resulted in no significant morphological changes in the MS-irradiated compared to non-irradiated surfaces. In MS surfaces, minor changes were observed in the increase of 1000× when compared to non-irradiated surface. With 2 W of power, there were no significant morphological changes in the MS, compared to non-irradiated areas. In AC some changes were observed in the increase of X 1000, showing areas of wear suggestive of treatment and some areas with melting point. Conclusion: Considering the results and the parameters used in this study it was concluded that the Er, Cr: YSGG irradiation can be used for the machined surfaces of implants, but in acid-treated surfaces irradiation parameters should be more controlled.
Resumo:
É descrita a invenção de um método de modificação da superfície 5 de ligas de titânio empregando a oxidação anódica em ligas de Ti- 30Ta e Ti-7,5Mo para a obtenção de nanotubos perpendiculares ao substrato com diâmetro de 80-120 nm e comprimento de 100 nm-500 nm.