974 resultados para Thrust curve
Resumo:
Thin films of perovskite-type materials such as PbTiO3, BaTiO3, (Pb,La)TiO3, (Pb, La)(ZrTi)O-3, KNbO3, and Pb(Mg,Nb)03 have been attracting great interest for applications like non-volatile memories, ultrasonic sensors and optical devices. Thin film should be epitaxially grown or at least highly textured since the properties of this anisotropic material depend on the crystallographic orientation. For optical devices, in particular, an epitaxial thin film without defects are essential to reduce optical propagation losses. Pb1-xLaxTiO3 (PLT) where x=0, 13 and 27% thin films were prepared by a chemical method (polymeric precursors method), and deposited by the spin coating technique onto substrates of SrTiO3 (STO) and LaAlO3 (LAO). The films were then beat treated at 500 degrees C in a controlled atmosphere of 0,. The orientation degree of the thin films was obtained from rocking curve technique, by means of X-ray difftaction analysis. A microstructural study revealed that the films were crack-free, homogeneous and have low roughness. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
This paper shows a new manner to establish the thrust of a linear induction machine. A new factor is established, named ''Relation Factor, which provides conditions to establish the thrust and other important variables of the linear and sector induction machines.
Resumo:
The caprine oxyhemoglobin dissociation curve has not been previously defined. Blood from 10 healthy goats was equilibrated in a tonometer with calibrated gas mixtures of oxygen at concentrations of 95%, 21%, 13%, 12%, 10%, 9%, 8%, 5%, 4% and 2.5%, 5% carbon dioxide, balance nitrogen. The pH, partial pressure of oxygen (PO2), partial pressure of carbon dioxide (PCO2), total hemoglobin, oxyhemoglobin saturation, carboxyhemoglobin, methemoglobin, and oxygen content were measured. The PO2/oxyhemoglobin and the PO2/oxygen content relationships were graphed with curve-fitting software and a formula for calculating oxyhemoglobin from PO2 was generated. The maximum oxygen content per gram of hemoglobin was 1.29 ml of oxygen per gram of hemoglobin. The PO2 at which hemoglobin was 50% saturated (P-50) from the PO2/oxyhemoglobin relationship was 28.6 +/- 1.5 mmHg and that from the PO2/oxygen content relationships was 29.1 +/- 1.6 mmHg. The Hill coefficient for the PO2/oxyhemoglobin data was 3.0 +/- 0.4. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
The polymer surface degradation and/or modification evolution of Teflon FEP and Mylar C films caused by a low energy electron beam were analyzed using a new method that consists in measuring the second crossover energy shift in the electronic emission curve. Upon prolonged irradiation, the second crossover energy shifts irreversibly to lower values in Teflon FEP but to higher values in Mylar C, indicating distinct mechanisms of surface degradation for the two polymers. The method represents a relatively inexpensive way to monitor early stages of surface degradation since the secondary electron emission comes from a maximum depth below the geometric surface of 100 mn in insulators. (C) 2001 Elsevier B.V. Ltd. All rights reserved.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A 1000-kgf resistive strain-gauge load cell has been developed for quality testing of rocket propellant grain. A 7075-T6 aluminum alloy has been used for the elastic column, in which 8 uniaxial, 120-Ω strain gauges have been bonded and connected to form a full Wheatstone bridge to detect the strain. The chosen geometry makes the transducer insensitive to moments and, also, to the temperature. Experimental tests using a universal testing machine to imposed compression force to the load cell have demonstrated that its behavior is linear, with sensitivity of 2.90 μV/kgf ± 0.34%, and negligible hysteresis. The designed force transducer response to a dynamic test has been comparable to that of a commercial load cell. © 2005 IEEE.
Resumo:
Double-torsion tests were carried out on a commercial ceramic floor tile to verify whether this test is suitable for determining the R-curve of ceramics. The instantaneous crack length was obtained by means of compliance calibration, and it was found that the experimental compliance underestimates the real crack length. The load vs. displacement curves were also found to drop after maximum loading, causing the stress intensity factor to decline. The R-curves were calculated by two methods: linear elastic fracture mechanics and the energetic method. It was obtained that the average values of crack resistance, R, and the double of the work of fracture, 2 · γwof, did not depend on notch length, a0, which is a highly relevant finding, indicating that these parameters were less dependent on the test specimen's geometry. The proposal was to use small notches, which produce long stable crack propagation paths that in turn are particularly important in the case of coarse microstructures.
Resumo:
Objective: The aim of this study was to assess the existence of myofunctional alterations before and after first premolar extraction in Class II/1 malocclusion patients that could endanger the long-term dental arch stability. Materials and Methods: The study was performed by means of morphological, functional and electromyographic analyses in 17 Class II/1 malocclusion patients (group T) and 17 Class I malocclusion patients (group C), both groups with 12-30-year age range (mean age: 20.93 ± 4.94 years). Results: Data analyzed statistically by Student's t-test showed a significant decrease in the maxillary and mandibular dental arch perimeters after orthodontic treatment (p<0.05). The Kruskal-Wallis test analyzed data from tongue posture at rest and during swallowing, not showing significant differences after treatment (groups Tb and Ta) (p>0.05). However, group T differed significantly from group C (p<0.05). The electromyographic data showed that the anterior right and left suprahyoid muscles acted synergistically in both groups, while having a lower myoelectric activity in group T during swallowing. Conclusions: Myofunctional alterations observed after the orthodontic treatment in Class II/1 malocclusion seemed to jeopardize the long-term orthodontic stability, making recurrence possible. Further research should be conducted to compare electromyographic data before and after orthodontic treatment in order to corroborate the results of the present investigation.
Resumo:
The pCT deals with relatively thick targets like the human head or trunk. Thus, the fidelity of pCT as a tool for proton therapy planning depends on the accuracy of physical formulas used for proton interaction with thick absorbers. Although the actual overall accuracy of the proton stopping power in the Bethe-Bloch domain is about 1%, the analytical calculations and the Monte Carlo simulations with codes like TRIM/SRIM, MCNPX and GEANT4 do not agreed with each other. A tentative to validate the codes against experimental data for thick absorbers bring some difficulties: only a few data is available and the existing data sets have been acquired at different initial proton energies, and for different absorber materials. In this work we compare the results of our Monte Carlo simulations with existing experimental data in terms of reduced calibration curve, i.e. the range - energy dependence normalized on the range scale by the full projected CSDA range for given initial proton energy in a given material, taken from the NIST PSTAR database, and on the final proton energy scale - by the given initial energy of protons. This approach is almost energy and material independent. The results of our analysis are important for pCT development because the contradictions observed at arbitrary low initial proton energies could be easily scaled now to typical pCT energies. © 2010 American Institute of Physics.