979 resultados para Thoracic computed tomography scan


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The frequency of CT procedures has registered a significant increase over the last decade, which led at the international level to an increasing concern on the radiological risk associated with the use of CT especially in paediatrics. This work aimed at investigating the use of computed tomography in Switzerland, following the evolution of CT frequency and dose data over a decade and comparing it to data reported in other countries. METHODS: The frequency and dose data related to CT are obtained by means of a nationwide survey. National frequencies were established by projecting the collected data, using the ratio of the number of CT units belonging to the respondents to the total number of CT units in the country. The effective doses per examination were collected during an auditing campaign. RESULTS: In 2008 about 0.8 Million CT procedures (~ 100 CT examinations / 1000 population) were performed in the country, leading to a collective effective dose of more than 6000 man.Sv (0.8 mSv/caput). In a decade the frequency of CT examinations averaged over the population and the associated average effective dose per caput increased by a factor of 2.2 and 2.9 respectively. CONCLUSIONS: Although the contribution of CT to the total medical X-rays is 6% in terms of the frequency, it represents 68% in terms of the collective effective dose. These results are comparable to those reported in a number of countries in Europe and America with similar health level.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aims Perfusion-cardiac magnetic resonance (CMR) has emerged as a potential alternative to single-photon emission computed tomography (SPECT) to assess myocardial ischaemia non-invasively. The goal was to compare the diagnostic performance of perfusion-CMR and SPECT for the detection of coronary artery disease (CAD) using conventional X-ray coronary angiography (CXA) as the reference standard. Methods and results In this multivendor trial, 533 patients, eligible for CXA or SPECT, were enrolled in 33 centres (USA and Europe) with 515 patients receiving MR contrast medium. Single-photon emission computed tomography and CXA were performed within 4 weeks before or after CMR in all patients. The prevalence of CAD in the sample was 49%. Drop-out rates for CMR and SPECT were 5.6 and 3.7%, respectively (P = 0.21). The primary endpoint was non-inferiority of CMR vs. SPECT for both sensitivity and specificity for the detection of CAD. Readers were blinded vs. clinical data, CXA, and imaging results. As a secondary endpoint, the safety profile of the CMR examination was evaluated. For CMR and SPECT, the sensitivity scores were 0.67 and 0.59, respectively, with the lower confidence level for the difference of +0.02, indicating superiority of CMR over SPECT. The specificity scores for CMR and SPECT were 0.61 and 0.72, respectively (lower confidence level for the difference: -0.17), indicating inferiority of CMR vs. SPECT. No severe adverse events occurred in the 515 patients. Conclusion In this large multicentre, multivendor study, the sensitivity of perfusion-CMR to detect CAD was superior to SPECT, while its specificity was inferior to SPECT. Cardiac magnetic resonance is a safe alternative to SPECT to detect perfusion deficits in CAD.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Changes in bone mineral density and bone strength following treatment with zoledronic acid (ZOL) were measured by quantitative computed analysis (QCT) or dual-energy X-ray absorptiometry (DXA). ZOL treatment increased spine and hip BMD vs placebo, assessed by QCT and DXA. Changes in trabecular bone resulted in increased bone strength. INTRODUCTION: To investigate bone mineral density (BMD) changes in trabecular and cortical bone, estimated by quantitative computed analysis (QCT) or dual-energy X-ray absorptiometry (DXA), and whether zoledronic acid 5 mg (ZOL) affects bone strength. METHODS: In 233 women from a randomized, controlled trial of once-yearly ZOL, lumbar spine, total hip, femoral neck, and trochanter were assessed by DXA and QCT (baseline, Month 36). Mean percentage changes from baseline and between-treatment differences (ZOL vs placebo, t-test) were evaluated. RESULTS: Mean between-treatment differences for lumbar spine BMD were significant by DXA (7.0%, p < 0.01) and QCT (5.7%, p < 0.0001). Between-treatment differences were significant for trabecular spine (p = 0.0017) [non-parametric test], trabecular trochanter (10.7%, p < 0.0001), total hip (10.8%, p < 0.0001), and compressive strength indices at femoral neck (8.6%, p = 0.0001), and trochanter (14.1%, p < 0.0001). CONCLUSIONS: Once-yearly ZOL increased hip and spine BMD vs placebo, assessed by QCT vs DXA. Changes in trabecular bone resulted in increased indices of compressive strength.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3 +/- 3.4, coronary sinus 34.2 +/- 4.1, sino-tubular junction 29.7 +/- 3.4 and mid ascending aorta 32.7 +/- 3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6 +/- 11.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1 +/- 3.7, and between both coronary ostia 7.2 +/- 3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 +/- 9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.6 +/- 3.3, CV 13-43%. Mean aortic valve area was 582.0 +/- 131.9 mm(2). The variation of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To compare image quality of a standard-dose (SD) and a low-dose (LD) cervical spine CT protocol using filtered back-projection (FBP) and iterative reconstruction (IR). MATERIALS AND METHODS: Forty patients investigated by cervical spine CT were prospectively randomised into two groups: SD (120 kVp, 275 mAs) and LD (120 kVp, 150 mAs), both applying automatic tube current modulation. Data were reconstructed using both FBP and sinogram-affirmed IR. Image noise, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were measured. Two radiologists independently and blindly assessed the following anatomical structures at C3-C4 and C6-C7 levels, using a four-point scale: intervertebral disc, content of neural foramina and dural sac, ligaments, soft tissues and vertebrae. They subsequently rated overall image quality using a ten-point scale. RESULTS: For both protocols and at each disc level, IR significantly decreased image noise and increased SNR and CNR, compared with FBP. SNR and CNR were statistically equivalent in LD-IR and SD-FBP protocols. Regardless of the dose and disc level, the qualitative scores with IR compared with FBP, and with LD-IR compared with SD-FBP, were significantly higher or not statistically different for intervertebral discs, neural foramina and ligaments, while significantly lower or not statistically different for soft tissues and vertebrae. The overall image quality scores were significantly higher with IR compared with FBP, and with LD-IR compared with SD-FBP. CONCLUSION: LD-IR cervical spine CT provides better image quality for intervertebral discs, neural foramina and ligaments, and worse image quality for soft tissues and vertebrae, compared with SD-FBP, while reducing radiation dose by approximately 40 %.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: To analyze available evidence on the incidence of anatomical variations or disease of the maxillary sinuses as identified by cone beam computed tomography (CBCT) in dentistry. MATERIALS AND METHODS: A focused question was developed to search the electronic databases MEDLINE, EMBASE, the Cochrane Oral Health Group Trials Register, and CENTRAL and identify all relevant papers published between 1980 and January 19, 2013. Unpublished literature at ClinicalTrials.gov, in the National Research Register, and in the Pro-Quest Dissertation Abstracts and Thesis database was also included. Studies were included irrespective of language. These results were supplemented by hand and gray literature searches. RESULTS: Twenty-two studies were identified. Twenty were retrospective cohort studies, one was a prospective cohort study, and one was a case control study. The main indication for CBCT was dental implant treatment planning, and the majority of studies used a small field of view for imaging. The most common anatomical variations included increased thickness of the sinus membrane, the presence of sinus septa, and pneumatization. Reported sinus disease frequency varied widely, ranging from 14.3% to 82%. There was a wide range in the reported prevalence of mucosal thickening related to apical pathology, the degree of lumenal opacification, features of sinusitis, and the presence of retention cysts and polyps. More pathologic findings in the maxillary sinus were reported in men than in women, and the medial wall and sinus floor were most frequently affected. CONCLUSION: CBCT is used primarily to evaluate bony anatomy and to screen for overt pathology of the maxillary sinuses prior to dental implant treatment. Differences in the classification of mucosal findings are problematic in the consistent and valid assessment of health and disease of the maxillary sinus.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

To evaluate the sensitivity of postmortem computed tomography (PMCT) in rib fracture detection validated against autopsy. Fifty-one forensic cases underwent a postmortem CT prior to forensic autopsy. Two image readers (radiologist and forensic pathologist) assessed high resolution CT data sets for rib fractures. Correct recognition rates (CRR), sensitivity and specificity values were calculated over all observations as well as individually for every rib and region. Additionally, for partial rib fractures the sensitivity of autopsy was calculated vice versa. 3876 entries in each study protocol (autopsy, PMCT radiologist and PMCT forensic pathologist) were investigated. A total of 690 fractures (autopsy), 491 (PMCT and radiologist) and 559 (PMCT and forensic pathologist) were detected. The CRR was 0.85. Sensitivity and specificity of PMCT for rib fracture detection were 0.63 (0.58 radiologist, 0.68 forensic pathologist) and 0.97 (both readers 0.97), respectively. Low CRR and sensitivity values were obtained for antero-lateral fractures. Partial rib fractures were better detected by PMCT. PMCT has a rather low sensitivity for rib fracture detection when validated against autopsy and indicates that clinical CT may also demonstrate a reasonable number of false negatives. Partial rib fractures often remain undetected at autopsy.