Resumo:
The present study evaluated the effectiveness of electrotactile tongue biofeedback (BrainPort (R)) as a sensory substitute for the vestibular apparatus in patients with bilateral vestibular loss (BVL) who did not have a good response to conventional vestibular rehabilitation (VR). Seven patients with BVL were trained to use the device. Stimulation on the surface of the tongue was created by a dynamic pattern of electrical pulses and the patient was able to adjust the intensity of stimulation and spatially centralize the stimulus on the electrode array. Patients were directed to continuously adjust head orientation and to maintain the stimulus pattern at the center of the array. Postural tasks that present progressive difficulties were given during the use of the device. Pre- and post-treatment distribution of the sensory organization test (SOT) composite score showed an average value of 38.3 +/- 8.7 and 59.9 +/- 11.3, respectively, indicating a statistically significant improvement (p = 0.01). Electrotactile tongue biofeedback significantly improved the postural control of the study group, even if they had not improved with conventional VR. The electrotactile tongue biofeedback system was able to supply additional information about head position with respect to gravitational vertical orientation in the absence of vestibular input, improving postural control. Patients with BVL can integrate electrotactile information in their postural control in order to improve stability after conventional VR. These results were obtained and verified not only by the subjective questionnaire but also by the SOT composite score. The limitations of the study are the small sample size and short duration of the follow-up. The current findings show that the sensory substitution mediated by electrotactile tongue biofeedback may contribute to the improved balance experienced by these patients compared to VR. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Objectives. The aim of this study was to evaluate the effect of thermal and mechanical cycling alone or in combination, on the flexural strength of ceramic and metallic frameworks cast in gold alloy or titanium. Methods. Metallic frameworks (25 mm x 3 mm x 0.5 mm) (N = 96) cast in gold alloy or commercial pure titanium (Ti cp) were obtained using acrylic templates. They were airborne particle-abraded with 150 mu m aluminum oxide at the central area of the frameworks (8 mm x 3 mm). Bonding agent and opaque were applied on the particle-abraded surfaces and the corresponding ceramic for each metal was fired onto them. The thickness of the ceramic layer was standardized by positioning the frameworks in a metallic template (height: I mm). The specimens from each ceramic-metal combination (N = 96, n = 12 per group) were randomly assigned into four experimental fatigue conditions, namely water storage at 37 degrees C for 24 h (control group), thermal cycling (3000 cycles, between 4 and 55 degrees C, dwell time: 10 s), mechanical cycling (20,000 cycles under 10 N load, immersion in distilled water at 37 degrees C) and, thermal and mechanical cycling. A flexural strength test was performed in a universal testing machine (crosshead speed: 1.5 mm/min). Data were statistically analyzed using two-way ANOVA and Tukey`s test (alpha = 0.05). Results. The mean flexural strength values for the ceramic-gold alloy combination (55 +/- 7.2MPa) were significantly higher than those of the ceramic-Ti cp combination (32 +/- 6.7 MPa) regardless of the fatigue conditions performed (p < 0.05). Mechanical and thermo-mechanical fatigue decreased the flexural strength results significantly for both ceramic-gold alloy (52 +/- 6.6 and 53 +/- 5.6 MPa, respectively) and ceramic-Ti cp combinations (29 +/- 6.8 and 29 +/- 6.8 MPa, respectively) compared to the control group (58 +/- 7.8 and 39 SA MPa, for gold and Ti cp, respectively) (p < 0.05) (Tukey`s test). While ceramic-Ti cp combinations failed adhesively at the metal-opaque interface, gold alloy frameworks exhibited a residue of ceramic material on the surface in all experimental groups. Significance. Mechanical and thermo-mechanical fatigue conditions decreased the flexural strength values for both ceramic-gold alloy and ceramic-Ti cp combinations with the results being significantly lower for the latter in all experimental conditions. (C) 2007 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Central Nervous System disorders may cause important functional unbalance in the maintenance of balance and posture. There is no effective rehabilitation for these symptoms until now. Objective: The aim of this paper is to evaluate the use of tongue electrotactile stimulation on patients with central imbalance using BrainPort. Materials and Methods: This is a prospective case series study. We evaluated 8 patients with central imbalance, 6 men and 2 women, with mean age of 67.75 years. The patients were submitted to Computed Dynamic Posturography (CDP) and then received 18 sessions of electrotactile stimulation by BrainPort (R) device for 20 minutes, twice a day. Then they were submitted to a new CDP test and to a self-perception scale to assess symptom remission, partial improvement and no improvement at all. Results: 75% of the patients reported being more stable. There was no improvement in the balance control of the mass center in these patients. Conclusion: The patients were able to use the electrotactile stimulus to improve their balance control.
Resumo:
Because of the scarcity of information about the comparison of training to sedentarism beforehand immobilization and rehabilitation through muscle mechanical properties, the present work investigates this theme. Seventy rats were divided into 7 groups: 1-control (C); 2-trained (T); 3-sedentary (S); 4-trained and immobilized (TI); 5-sedentary and immobilized (SI); 6-trained, immobilized and rehabilitated (TIR); 7-sedentary, immobilized and rehabilitated (SIR). Interventions: Swimming training; Sedentarism (reduced size cages); Cast immobilization (pelvic limb) and water rehabilitation. Load at the limit of proportionality (LLP), maximum limit load (MLL) and stiffness (St) were the mechanical properties determined after a mechanical test of traction of the gastrocnemius. The training improved all mechanical properties when compared to sedentarism. After immobilization, LLP and MLL were reduced in TI and SI. However, there was no difference in St between C and TI. Additionally, TI showed improved MLL when compared to SI. The comparison of TI and TIR showed significant melioration in all properties after remobilization. SIR showed an improvement only in MLL when compared to SI. Significant melioration in LLP and St was observed in TIR compared to SIR. We demonstrated that the training before immobilization and rehabilitation had a positive effect on the muscle mechanical behavior compared to sedentarism. This analysis is of fundamental importance because it helps characterize the muscle tissue under different functional demands.
Resumo:
Purpose. aEuro integral Heart rate variability (HRV) decreases after an acute myocardial infarction (AMI) due to changes in cardiac autonomic balance. The purpose of the present study, therefore, was to evaluate the effects of a progressive exercise protocol used in phase I cardiac rehabilitation on the HRV of patients with post-AMI. Material and methods. aEuro integral Thirty-seven patients who had been admitted to hospital with their first non-complicated AMI were studied. The treated group (TG, n == 21, age == 52 +/-+/- 12 years) performed a 5-day programme of progressive exercise during phase I cardiac rehabilitation, while the control group (CG, n == 16, age == 54 +/-+/- 11 years) performed only respiratory exercises. Instantaneous heart rate (HR) and RR interval were acquired by a HR monitor (Polar (R) A (R) S810i). HRV was analysed by frequency domain methods. Power spectral density was expressed as normalised units (nu) at low (LF) and high (HF) frequencies, and as LF/HF. Results. aEuro integral After 5 days of progressive exercise, the TG showed an increase in HFnu (35.9 +/-+/- 19.5 to 65.19 +/-+/- 25.4) and a decrease in LFnu and LF/HF (58.9 +/-+/- 21.4 to 32.5 +/-+/- 24.1; 3.12 +/-+/- 4.0 to 1.0 +/-+/- 1.5, respectively) in the resting position (p < 0.05). No changes were observed in the CG. Conclusions. aEuro integral A progressive physiotherapeutic exercise programme carried out during phase I cardiac rehabilitation, as supplement to clinical treatment increased vagal and decreased sympathetic cardiac modulation in patients with post-AMI.