972 resultados para Testing conditions
Resumo:
The interactions between outdoor bronzes and the environment, which lead to bronze corrosion, require a better understanding in order to design effective conservation strategies in the Cultural Heritage field. In the present work, investigations on real patinas of the outdoor monument to Vittorio Bottego (Parma, Italy) and laboratory studies on accelerated corrosion testing of inhibited (by silane-based films, with and without ceria nanoparticles) and non-inhibited quaternary bronzes are reported and discussed. In particular, a wet&dry ageing method was used both for testing the efficiency of the inhibitor and for patinating bronze coupons before applying the inhibitor. A wide range of spectroscopic techniques has been used, for characterizing the core metal (SEM+EDS, XRF, AAS), the corroded surfaces (SEM+EDS, portable XRF, micro-Raman, ATR-IR, Py-GC-MS) and the ageing solutions (AAS). The main conclusions were: 1. The investigations on the Bottego monument confirmed the differentiation of the corrosion products as a function of the exposure geometry, already observed in previous works, further highlighting the need to take into account the different surface features when selecting conservation procedures such as the application of inhibitors (i.e. the relative Sn enrichment in unsheltered areas requires inhibitors which effectively interact not only with Cu but also with Sn). 2. The ageing (pre-patination) cycle on coupons was able to reproduce the relative Sn enrichment that actually happens in real patinated surfaces, making the bronze specimens representative of the real support for bronze inhibitors. 3. The non-toxic silane-based inhibitors display a good protective efficiency towards pre-patinated surfaces, differently from other widely used inhibitors such as benzotriazole (BTA) and its derivatives. 4. The 3-mercapto-propyl-trimethoxy-silane (PropS-SH) additivated with CeO2 nanoparticles generally offered a better corrosion protection than PropS-SH.
Resumo:
The beta-decay of free neutrons is a strongly over-determined process in the Standard Model (SM) of Particle Physics and is described by a multitude of observables. Some of those observables are sensitive to physics beyond the SM. For example, the correlation coefficients of the involved particles belong to them. The spectrometer aSPECT was designed to measure precisely the shape of the proton energy spectrum and to extract from it the electron anti-neutrino angular correlation coefficient "a". A first test period (2005/ 2006) showed the “proof-of-principles”. The limiting influence of uncontrollable background conditions in the spectrometer made it impossible to extract a reliable value for the coefficient "a" (publication: Baessler et al., 2008, Europhys. Journ. A, 38, p.17-26). A second measurement cycle (2007/ 2008) aimed to under-run the relative accuracy of previous experiments (Stratowa et al. (1978), Byrne et al. (2002)) da/a =5%. I performed the analysis of the data taken there which is the emphasis of this doctoral thesis. A central point are background studies. The systematic impact of background on a was reduced to da/a(syst.)=0.61 %. The statistical accuracy of the analyzed measurements is da/a(stat.)=1.4 %. Besides, saturation effects of the detector electronics were investigated which were initially observed. These turned out not to be correctable on a sufficient level. An applicable idea how to avoid the saturation effects will be discussed in the last chapter.
Resumo:
Flow features inside centrifugal compressor stages are very complicated to simulate with numerical tools due to the highly complex geometry and varying gas conditions all across the machine. For this reason, a big effort is currently being made to increase the fidelity of the numerical models during the design and validation phases. Computational Fluid Dynamics (CFD) plays an increasing role in the assessment of the performance prediction of centrifugal compressor stages. Historically, CFD was considered reliable for performance prediction on a qualitatively level, whereas tests were necessary to predict compressors performance on a quantitatively basis. In fact "standard" CFD with only the flow-path and blades included into the computational domain is known to be weak in capturing efficiency level and operating range accurately due to the under-estimation of losses and the lack of secondary flows modeling. This research project aims to fill the gap in accuracy between "standard" CFD and tests data by including a high fidelity reproduction of the gas domain and the use of advanced numerical models and tools introduced in the author's OEM in-house CFD code. In other words, this thesis describes a methodology by which virtual tests can be conducted on single stages and multistage centrifugal compressors in a similar fashion to a typical rig test that guarantee end users to operate machines with a confidence level not achievable before. Furthermore, the new "high fidelity" approach allowed understanding flow phenomena not fully captured before, increasing aerodynamicists capability and confidence in designing high efficiency and high reliable centrifugal compressor stages.
Resumo:
In areas of seasonal frost, frost susceptibility composed by frost heaving during the winter and thaw softening during the spring is one of the most dangerous phenomenon for transportation, road and railway infrastructure. Therefore, the need for frost protection layer becomes imperative. The purpose of frost protection layer is to prevent frost from penetrating down through the pavement and into the sub-soils. Frost susceptible soils under the road can be cause damages on the roads or other structures due to frost heave or reduced capacity characteristics thaw period. "Frost heave" is the term given to the upwards displacement of the ground surface caused by the formation of ice within soils or aggregates (Rempel et al., 2004). Nowadays in Scandinavia the most common material used in frost protection layer in the pavement structure of roads and in the ballast of the railway tracks are coarse-grain crushed rocks aggregates. Based on the capillary rise, the mechanics of frost heave phenomenon is based on the interaction between aggregates and water, as suggested by Konrad and Lemieux in 2005 that said that the fraction of material below the 0.063 mm sieve for coarse-grained soils must be controlled so as to reduce the sensitivity to frost heave. The study conducted in this thesis project is divided in two parts: - the analysis of the coarse grained aggregates used in frost protection layer in Norway; - the analysis of the frost heave phenomenon in the laboratory under known boundary conditions, through the use of the most widely used method, the frost heave test, in” closed system” (without access of water).
Resumo:
Despite the many proposed advantages related to nanotechnology, there are increasing concerns as to the potential adverse human health and environmental effects that the production of, and subsequent exposure to nanoparticles (NPs) might pose. In regard to human health, these concerns are founded upon the plethora of knowledge gained from research relating to the effects observed following exposure to environmental air pollution. It is known that increased exposure to environmental air pollution can cause reduced respiratory health, as well as exacerbate pre-existing conditions such as cardiovascular disease and chronic obstructive pulmonary disease. Such disease states have also been associated with exposure to the NP component contained within environmental air pollution, raising concerns as to the effects of NP exposure. It is not only exposure to accidentally produced NPs however, which should be approached with caution. Over the past decades, NPs have been specifically engineered for a wide range of consumer, industrial and technological applications. Due to the inevitable exposure of NPs to humans, owing to their use in such applications, it is therefore imperative that an understanding of how NPs interact with the human body is gained. In vivo research poses a beneficial model for gaining immediate and direct knowledge of human exposure to such xenobiotics. This research outlook however, has numerous limitations. Increased research using in vitro models has therefore been performed, as these models provide an inexpensive and high-throughput alternative to in vivo research strategies. Despite such advantages, there are also various restrictions in regard to in vitro research. Therefore, the aim of this review, in addition to providing a short perspective upon the field of nanotoxicology, is to discuss (1) the advantages and disadvantages of in vitro research and (2) how in vitro research may provide essential information pertaining to the human health risks posed by NP exposure.
Resumo:
This meta-analysis investigated whether the association between researcher allegiance (RA) and the relative effect of two psychotherapies can be explained through the methodological weaknesses of the treatment comparisons. Seventy-nine comparisons of psychotherapies for depression or posttraumatic stress disorder (PTSD) were included. Methodological quality (MQ) was investigated as both a moderator and a mediator of the RA-outcome association. MQ included balanced nonspecific factors, balanced specific factors, conceptual quality, patients-per-therapist ratio, randomization to conditions and outcome assessment. The RA-outcome association was stronger when the MQ was low, suggesting a buffering effect of MQ. In addition, differences in the conceptual quality of treatments mediated the effect of RA on outcome. The results support the view that RA acts as a bias in treatment comparisons.
Resumo:
Background: Knowledge about HD in China is lacking in the international literature. We have therefore analyzed the Chinese literature to thoroughly explore the clinical characteristics of Huntington disease in China. Methods: A computer-based online search of China National Knowledge Infrastructure was performed to review case reports concerning HD published between January 1980 and April of 2011, and the clinical characteristics were extracted. Results: A total of 92 studies involving 279 patients (157 males and 122 females) were collected, 82.0% of which were from provinces of North China. Most of the cases (97.8%) had a family history of HD, and paternal inheritance (65.5%) was higher than maternal inheritance (34.5%). Onset age was 35.8 (± 11.8) years, death occurred with 45.6 (± 13.5) years after a course of 11.6 (± 5.6) years. Involuntary movements were the most frequent reported presentation (found in 52.3%, including 64.4% in the entire body, 19.8% in the upper limbs, and 13.7% in the head and face). Psychiatric symptoms at onset were reported in 16.1%, and cognitive impairment in 1.8%. With disease progression, 99.6% of patients had abnormal movements, 67.9% cognitive impairment, and 35.0% suffered psychiatric symptoms. Of the reported patients, only 22 underwent IT15 gene testing with positive results. Conclusion: HD is a well-reported entity in Chinese medical literature, however, only a small number of instances have been proven by molecular diagnosis. Most of the features resemble what is known in other countries. The highly predominant motor presentation, and the higher male prevalence as well as the apparent concentration in Northern China may be due to observational bias. There is therefore a need to prospectively examine cohorts of patients with appropriate comprehensive assessment tools including genetic testing.
Resumo:
OBJECTIVE: The objective of this study was to analyze the autonomic functions of patients with erythrophobia. METHODS: Forty patients with a diagnosis of erythrophobia (female/male ratio 18/22) without any other organic lesions and 20 healthy volunteers (female/male ratio 10/10) were assessed. Clinical evaluation was performed using a modified version of semistructured interviews. Autonomic testing was performed by means of spectral analysis of heart rate and continuous blood pressure by sparse discrete Fourier transformation at rest and under mental stress. RESULTS: There were no significant difference between the two samples in age, sex distribution, BMI, resting systolic, or diastolic blood pressure, nor was there a difference in autonomic baseline functioning between the 40 patients with erythrophobia and the control subjects. On the other hand, patients with erythrophobia consistently showed higher pulse rates (88 +/- 20 vs. 78 +/- 9 bpm, p <.05), higher total heart rate power values (8.40 +/- 0.63 vs. 8.07 +/- 1.02 p <.05), higher midfrequency spectral values (7.38 +/- 0.66 vs. 7.02 +/- 1.18, p <.01), higher high-frequency spectral values (6.89 +/- 0.86 vs. 6.48 +/- 1.44, p <.05), and lower baroreceptor sensitivity (8.62 +/- 8.16 vs. 11.65 +/- 4.42, p <.005) than the healthy subjects. ANOVA showed a significant group interaction (p <.0001) between the samples. CONCLUSIONS: This study provides evidence for abnormal autonomic functioning in patients with erythrophobia when under mental stress.
Resumo:
The GLAaS algorithm for pretreatment intensity modulation radiation therapy absolute dose verification based on the use of amorphous silicon detectors, as described in Nicolini et al. [G. Nicolini, A. Fogliata, E. Vanetti, A. Clivio, and L. Cozzi, Med. Phys. 33, 2839-2851 (2006)], was tested under a variety of experimental conditions to investigate its robustness, the possibility of using it in different clinics and its performance. GLAaS was therefore tested on a low-energy Varian Clinac (6 MV) equipped with an amorphous silicon Portal Vision PV-aS500 with electronic readout IAS2 and on a high-energy Clinac (6 and 15 MV) equipped with a PV-aS1000 and IAS3 electronics. Tests were performed for three calibration conditions: A: adding buildup on the top of the cassette such that SDD-SSD = d(max) and comparing measurements with corresponding doses computed at d(max), B: without adding any buildup on the top of the cassette and considering only the intrinsic water-equivalent thickness of the electronic portal imaging devices device (0.8 cm), and C: without adding any buildup on the top of the cassette but comparing measurements against doses computed at d(max). This procedure is similar to that usually applied when in vivo dosimetry is performed with solid state diodes without sufficient buildup material. Quantitatively, the gamma index (gamma), as described by Low et al. [D. A. Low, W. B. Harms, S. Mutic, and J. A. Purdy, Med. Phys. 25, 656-660 (1998)], was assessed. The gamma index was computed for a distance to agreement (DTA) of 3 mm. The dose difference deltaD was considered as 2%, 3%, and 4%. As a measure of the quality of results, the fraction of field area with gamma larger than 1 (%FA) was scored. Results over a set of 50 test samples (including fields from head and neck, breast, prostate, anal canal, and brain cases) and from the long-term routine usage, demonstrated the robustness and stability of GLAaS. In general, the mean values of %FA remain below 3% for deltaD equal or larger than 3%, while they are slightly larger for deltaD = 2% with %FA in the range from 3% to 8%. Since its introduction in routine practice, 1453 fields have been verified with GLAaS at the authors' institute (6 MV beam). Using a DTA of 3 mm and a deltaD of 4% the authors obtained %FA = 0.9 +/- 1.1 for the entire data set while, stratifying according to the dose calculation algorithm, they observed: %FA = 0.7 +/- 0.9 for fields computed with the analytical anisotropic algorithm and %FA = 2.4 +/- 1.3 for pencil-beam based fields with a statistically significant difference between the two groups. If data are stratified according to field splitting, they observed %FA = 0.8 +/- 1.0 for split fields and 1.0 +/- 1.2 for nonsplit fields without any significant difference.
Resumo:
Transformers are very important elements of any power system. Unfortunately, they are subjected to through-faults and abnormal operating conditions which can affect not only the transformer itself but also other equipment connected to the transformer. Thus, it is essential to provide sufficient protection for transformers as well as the best possible selectivity and sensitivity of the protection. Nowadays microprocessor-based relays are widely used to protect power equipment. Current differential and voltage protection strategies are used in transformer protection applications and provide fast and sensitive multi-level protection and monitoring. The elements responsible for detecting turn-to-turn and turn-to-ground faults are the negative-sequence percentage differential element and restricted earth-fault (REF) element, respectively. During severe internal faults current transformers can saturate and slow down the speed of relay operation which affects the degree of equipment damage. The scope of this work is to develop a modeling methodology to perform simulations and laboratory tests for internal faults such as turn-to-turn and turn-to-ground for two step-down power transformers with capacity ratings of 11.2 MVA and 290 MVA. The simulated current waveforms are injected to a microprocessor relay to check its sensitivity for these internal faults. Saturation of current transformers is also studied in this work. All simulations are performed with the Alternative Transients Program (ATP) utilizing the internal fault model for three-phase two-winding transformers. The tested microprocessor relay is the SEL-487E current differential and voltage protection relay. The results showed that the ATP internal fault model can be used for testing microprocessor relays for any percentage of turns involved in an internal fault. An interesting observation from the experiments was that the SEL-487E relay is more sensitive to turn-to-turn faults than advertized for the transformers studied. The sensitivity of the restricted earth-fault element was confirmed. CT saturation cases showed that low accuracy CTs can be saturated with a high percentage of turn-to-turn faults, where the CT burden will affect the extent of saturation. Recommendations for future work include more accurate simulation of internal faults, transformer energization inrush, and other scenarios involving core saturation, using the newest version of the internal fault model. The SEL-487E relay or other microprocessor relays should again be tested for performance. Also, application of a grounding bank to the delta-connected side of a transformer will increase the zone of protection and relay performance can be tested for internal ground faults on both sides of a transformer.
Resumo:
There is no accepted way of measuring prothrombin time without time loss for patients undergoing major surgery who are at risk of intraoperative dilution and consumption coagulopathy due to bleeding and volume replacement with crystalloids or colloids. Decisions to transfuse fresh frozen plasma and procoagulatory drugs have to rely on clinical judgment in these situations. Point-of-care devices are considerably faster than the standard laboratory methods. In this study we assessed the accuracy of a Point-of-care (PoC) device measuring prothrombin time compared to the standard laboratory method. Patients undergoing major surgery and intensive care unit patients were included. PoC prothrombin time was measured by CoaguChek XS Plus (Roche Diagnostics, Switzerland). PoC and reference tests were performed independently and interpreted under blinded conditions. Using a cut-off prothrombin time of 50%, we calculated diagnostic accuracy measures, plotted a receiver operating characteristic (ROC) curve and tested for equivalence between the two methods. PoC sensitivity and specificity were 95% (95% CI 77%, 100%) and 95% (95% CI 91%, 98%) respectively. The negative likelihood ratio was 0.05 (95% CI 0.01, 0.32). The positive likelihood ratio was 19.57 (95% CI 10.62, 36.06). The area under the ROC curve was 0.988. Equivalence between the two methods was confirmed. CoaguChek XS Plus is a rapid and highly accurate test compared with the reference test. These findings suggest that PoC testing will be useful for monitoring intraoperative prothrombin time when coagulopathy is suspected. It could lead to a more rational use of expensive and limited blood bank resources.
Resumo:
A tandem mass spectral database system consists of a library of reference spectra and a search program. State-of-the-art search programs show a high tolerance for variability in compound-specific fragmentation patterns produced by collision-induced decomposition and enable sensitive and specific 'identity search'. In this communication, performance characteristics of two search algorithms combined with the 'Wiley Registry of Tandem Mass Spectral Data, MSforID' (Wiley Registry MSMS, John Wiley and Sons, Hoboken, NJ, USA) were evaluated. The search algorithms tested were the MSMS search algorithm implemented in the NIST MS Search program 2.0g (NIST, Gaithersburg, MD, USA) and the MSforID algorithm (John Wiley and Sons, Hoboken, NJ, USA). Sample spectra were acquired on different instruments and, thus, covered a broad range of possible experimental conditions or were generated in silico. For each algorithm, more than 30,000 matches were performed. Statistical evaluation of the library search results revealed that principally both search algorithms can be combined with the Wiley Registry MSMS to create a reliable identification tool. It appears, however, that a higher degree of spectral similarity is necessary to obtain a correct match with the NIST MS Search program. This characteristic of the NIST MS Search program has a positive effect on specificity as it helps to avoid false positive matches (type I errors), but reduces sensitivity. Thus, particularly with sample spectra acquired on instruments differing in their Setup from tandem-in-space type fragmentation, a comparably higher number of false negative matches (type II errors) were observed by searching the Wiley Registry MSMS.
Resumo:
Due to widespread development of anthelmintic resistance in equine parasites, recommendations for their control are currently undergoing marked changes with a shift of emphasis toward more coprological surveillance and reduced treatment intensity. Denmark was the first nation to introduce prescription-only restrictions of anthelmintic drugs in 1999, but other European countries have implemented similar legislations over recent years. A questionnaire survey was performed in 2008 among Danish horse owners to provide a current status of practices and perceptions with relation to parasite control. Questions aimed at describing the current use of coprological surveillance and resulting anthelmintic treatment intensities, evaluating knowledge and perceptions about the importance of various attributes of parasite control, and assessing respondents' willingness to pay for advice and parasite surveillance services from their veterinarians. A total of 1060 respondents completed the questionnaire. A large majority of respondents (71.9%) were familiar with the concept of selective therapy. Results illustrated that the respondents' self-evaluation of their knowledge about parasites and their control associated significantly with their level of interest in the topic and their type of education (P<0.0001). The large majority of respondents either dewormed their horses twice a year and/or performed two fecal egg counts per horse per year. This approach was almost equally pronounced in foals, horses aged 1-3 years old, and adult horses. The respondents rated prevention of parasitic disease and prevention of drug resistance as the most important attributes, while cost and frequent fecal testing were rated least important. Respondents' actual spending on parasite control per horse in the previous year correlated significantly with the amount they declared themselves willing to spend (P<0.0001). However, 44.4% declared themselves willing to pay more than what they were spending. Altogether, results indicate that respondents were generally familiar with equine parasites and the concept of selective therapy, although there was some confusion over the terms small and large strongyles. They used a large degree of fecal surveillance in all age groups, with a majority of respondents sampling and/or treating around twice a year. Finally, respondents appeared willing to spend money on parasite control for their horses. It is of concern that the survey suggested that foals and young horses are treated in a manner very similar to adult horses, which is against current recommendations. Thus, the survey illustrates the importance of clear communication of guidelines for equine parasite control.
Resumo:
This study reports on a microfluidic platform on which single multicellular spheroids from malignant pleural mesothelioma (MPM), an aggressive tumor with poor prognosis, can be loaded, trapped and tested for chemotherapeutic drug response. A new method to detect the spheroid viability cultured on the microfluidic chip as a function of the drug concentration is presented. This approach is based on the evaluation of the caspase activity in the supernatant sampled from the chip and tested using a microplate reader. This simple and time-saving method does only require a minimum amount of manipulations and was established for very low numbers of cells. This feature is particularly important in view of personalised medicine applications for which the number of cells obtained from the patients is low. MPM spheroids were continuously perfused for 48 hours with cisplatin, one of the standard chemotherapeutic drugs used to treat MPM. The 50% growth inhibitory concentration of cisplatin in perfused MPM spheroids was found to be twice as high as in spheroids cultured under static conditions. This chemoresistance increase might be due to the continuous support of nutrients and oxygen to the perfused spheroids.
Resumo:
DNA testing is available for a growing number of hereditary diseases in neurology and other specialties. In addition to guiding breeding decisions, DNA tests are important tools in the diagnosis of diseases, particularly in conditions for which clinical signs are relatively nonspecific. DNA testing also can provide valuable insight into the risk of hereditary disease when decisions about treating comorbidities are being made. Advances in technology and bioinformatics will make broad screening for potential disease-causing mutations available soon. As DNA tests come into more common use, it is critical that clinicians understand the proper application and interpretation of these test results.