947 resultados para Test method


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Analysis methods for electrochemical etching baths consisting of various concentrations of hydrofluoric acid (HF) and an additional organic surface wetting agent are presented. These electrolytes are used for the formation of meso- and macroporous silicon. Monitoring the etching bath composition requires at least one method each for the determination of the HF concentration and the organic content of the bath. However, it is a precondition that the analysis equipment withstands the aggressive HF. Titration and a fluoride ion-selective electrode are used for the determination of the HF and a cuvette test method for the analysis of the organic content, respectively. The most suitable analysis method is identified depending on the components in the electrolyte with the focus on capability of resistance against the aggressive HF.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Se evalúa si una sola extracción, mediante la aplicación de un método de ensayo normalizado que simula condiciones extremas de uso, permite determinar el contenido total de plomo y cadmio presente en piezas de vajilla cerámica que entran en contacto con los alimentos y su implicación en el resultado analítico. Se aplicó el método de ensayo varias veces sobre materiales de referencia de cerámica con diferentes concentraciones iniciales de plomo y el cadmio para cuantificar la liberación sucesiva de ambos metales. El lixiviado en cada aplicación se analizó por absorción atómica. Los resultados mostraron que una sola aplicación del método de ensayo no extrae todo el plomo y el cadmio en la vajilla cerámica. Se observaron liberaciones posteriores para todas las piezas de cerámica a prueba con diferente concentración inicial. Para cadmio se registraron las siguientes variaciones en las extracciones: 40 a 95% en la primera extracción, de 0 a 28% en la segunda, de 0.2 hasta 21% en la tercera, y de 1 a 40% en la cuarta. Para el plomo, se registraron los subsiguientes valores en los lixiviados entre el 50 y el 93% en la primera prueba, entre el 2 y el 24% en la segunda, entre el 2 y el 18% en la tercera y entre el 2 y el 17% en la cuarta extracción. Los resultados revelan que la cantidad total de plomo y cadmio liberado en una sola prueba estándar no reflejan el contenido total de plomo y cadmio que las piezas de cerámica liberan a largo plazo después de su uso.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Antecedentes: El cáncer gástrico se diagnostica tardíamente. Sólo en países como Corea y Japón existen políticas de tamizaje, que se justificarían en cualquier país con alta prevalencia de cáncer gástrico como Colombia o Chile. El análisis del pepsinógeno sérico se ha propuesto para el diagnóstico de lesiones premalignas y malignas gástricas, por lo cual se pretende revisar sistemáticamente en la literatura el valor diagnóstico del cociente pepsinógeno I/II como marcador de lesiones premalignas y malignas gástricas. Metodología: Se revisó la literatura hasta septiembre del 2016 con palabras claves lesiones malignas, premalignas gástricas y pepsinógeno en las bases de datos PubMed, OVID, EMBASE, EBSCO, LILACS, OPENGRAY y Dialnet, artículos de prueba diagnóstica que evaluaran el cociente pepsinógeno I/II en relación con los hallazgos histológicos. Resultados: Se incluyeron 21 artículos conun total de 20601 pacientes, que demuestranuna sensibilidad entre13.7% - 91.2%, una especificidad entre 38.5% - 100%, un Valor Predictivo Positivo entre 6.3% - 100% y un Valor Predictivo Negativo entre 33.3% - 98.8%del cociente pepsinógeno I/II en relación con el diagnósticode lesiones premalignas y malignas gástricas. Conclusiones: Los valores del cociente pepsinógeno I/II disminuidos se relacionan con la presencia delesiones premalignas y malignas gástricas.Dado que tiene mejor especificidad que sensibilidad, en cuanto prueba para tamizaje, sería útil para la selección de pacientes que se beneficiaríande la EVDA. Se requieren más estudios de prueba diagnóstica para validar un punto de corte específico que pueda ser utilizado como valor estándar.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This research proposes a solution for integrating RFID - Radio Frequency Identification technology within a structure based on CFRPs - Carbon Fiber Reinforced Polymers. Therefore, the main objective is to use technology to monitor and track composite components during manufacturing and service life. The study can be divided into two macro-areas. The first portion of the research evaluates the impact of the composite materials used on transmitting the electromagnetic signal to and from the tag. RFID technology communicates through radio frequencies to to track and trace items associated with the tags. In the first instance, a feasibility study was carried out to assess using commercially available tags. Then, after evaluating different solutions, it was decided to incorporate the tags into coupons during production. The second portion of the research is focused on evaluating the impact on the composite material's resistance to tag embedding. It starts with designing tensile test specimens through the FEM model with different housing configurations. Subsequently, the best configuration was tested in the facilities of the In the Faculty of Aerospace Engineering at TU Delft, particularly in the Structure & Materials Laboratory, two tests were conducted: the first one based on ASTM D3039/D3039 - 14 - Standard Test Method for Tensile Properties of Polymer Matrix Composite Materials, the second one dividing the path to failure into failure intervals in a load-unload-reload. Both tests were accompanied by instruments such as DIC, AE, C-Scan and Optical Microscopes. The expected result of the inclusion of RFID tags in composite components is that it brings added value to the parts with which it is associated without affecting too much its mechanical properties. This comes first from the automatic identification of RFID during the production cycle and its useful life. As a result, improvements were made in the design of production facilities.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sales prediction plays a huge role in modern business strategies. One of it's many use cases revolves around estimating the effects of promotions. While promotions generally have a positive effect on sales of the promoted product, they can also have a negative effect on those of other products. This phenomenon is calles sales cannibalisation. Sales cannibalisation can pose a big problem to sales forcasting algorithms. A lot of times, these algorithms focus on sales over time of a single product in a single store (a couple). This research focusses on using knowledge of a product across multiple different stores. To achieve this, we applied transfer learning on a neural model developed by Kantar Consulting to demo an approach to estimating the effect of cannibalisation. Our results show a performance increase of between 10 and 14 percent. This is a very good and desired result, and Kantar will use the approach when integrating this test method into their actual systems.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Some Latin American countries have plans for total control and/or eradication of Chagas disease by the main vector (Triatoma infestans) and by blood transfusion. To achieve this, patients with Chagas disease must be identified. A Western blotting test, TESAcruzi, is described as a supplemental test for diagnosis of Chagas disease using samples collected from children <5 years living in different states of Brazil. Blood samples collected by finger prick on filter paper were sent to the test laboratory by a central laboratory to confirm results obtained previously. Ten percent of negative samples, all doubtful and all positive samples were received. Commercial reagents, IgG indirect immunofluorescence, enzyme immunoassay, and a recently introduced TESAcruzi test were used. From 8788 samples, 163 (1.85%) were reactive by IgG-ELISA and 312 (3.55%) by IgG IIF. From these, 77 (0.87%) were reactive in the TESAcruzi test. The results had high clinical value to identify those truly infected. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The pathogenesis of the renal lesion upon envenomation by snakebite has been related to myolysis, hemolysis, hypotension and/or direct venom nephrotoxicity caused by the venom. Both primary and continuous cell culture systems provide an in vitro alternative for quantitative evaluation of the toxicity of snake venoms. Crude Crotalus vegrandis venom was fractionated by molecular exclusion chromatography. The toxicity of C. vegrandis crude venom, hemorrhagic, and neurotoxic fractions were evaluated on mouse primary renal cells and a continuous cell line of Vero cells maintained in vitro. Cells were isolated from murine renal cortex and were grown in 96 well plates with Dulbecco's Modified Essential Medium (DMEM) and challenged with crude and venom fractions. The murine renal cortex cells exhibited epithelial morphology and the majority showed smooth muscle actin determined by immune-staining. The cytotoxicity was evaluated by the tetrazolium colorimetric method. Cell viability was less for crude venom, followed by the hemorrhagic and neurotoxic fractions with a CT50 of 4.93, 18.41 and 50.22 µg/mL, respectively. The Vero cell cultures seemed to be more sensitive with a CT50 of 2.9 and 1.4 µg/mL for crude venom and the hemorrhagic peak, respectively. The results of this study show the potential of using cell culture system to evaluate venom toxicity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Nucleic Acid Testing (NAT) as a tool for primary screening of blood donors became a reality in the end of the 1990 decade. We report here the development of an "in-house" RT-PCR method that allows the simultaneous (multiplex) detection of HCV and HIV-RNA in addition to an artificial RNA employed as an external control. This method detects all HIV group M subtypes, plus group N and O, with a detection threshold of 500 IU/mL. After validation, the method replaced p24 Ag testing, in use for blood donation screening since 1996 at our services. From July 2001 to February 2006, 102,469 donations were tested and 41 (0.04%) were found HIV-RNA reactive. One NAT-only reactive donation (antibody non-reactive) was observed, with subsequent seroconversion of the implied donor, giving a yield of 1:102,469. This rate is in contrast to the international experience that reports a detection of approximately 1:600,000 - 1:3,100,000 of isolated HIV-RNA donations.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The susceptibility patterns of 108 Campylobacter jejuni subsp. jejuni clinical strains, to six antimicrobial agents was determined by using the E-test and the double dilution agar methods. Using both metods, no strain was found to be resistant to ciprofloxacin, erythromycin and gentamicin, but two (1.8%) were resistant to tetracycline and all to aztreonam. Seven (6.5%) strains were resistant to ampicillin by the E-test and five (4.6%) by the double dilution agar method and by both meyhods. No great discrepancies were observed between both methods.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The aim of this study was to investigate the correlation between proportion method with mycobacteria growth indicator tube (MGIT) and E-test for Mycobacterium tuberculosis. Forty clinical isolates were tested. MGIT and E-test with the first line antituberculous drugs correlated with the proportion method. Our results suggested that MGIT and E-test methods can be routinely used instead of the proportion method.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Nowadays the used fuel variety in power boilers is widening and new boiler constructions and running models have to be developed. This research and development is done in small pilot plants where more faster analyse about the boiler mass and heat balance is needed to be able to find and do the right decisions already during the test run. The barrier on determining boiler balance during test runs is the long process of chemical analyses of collected input and outputmatter samples. The present work is concentrating on finding a way to determinethe boiler balance without chemical analyses and optimise the test rig to get the best possible accuracy for heat and mass balance of the boiler. The purpose of this work was to create an automatic boiler balance calculation method for 4 MW CFB/BFB pilot boiler of Kvaerner Pulping Oy located in Messukylä in Tampere. The calculation was created in the data management computer of pilot plants automation system. The calculation is made in Microsoft Excel environment, which gives a good base and functions for handling large databases and calculations without any delicate programming. The automation system in pilot plant was reconstructed und updated by Metso Automation Oy during year 2001 and the new system MetsoDNA has good data management properties, which is necessary for big calculations as boiler balance calculation. Two possible methods for calculating boiler balance during test run were found. Either the fuel flow is determined, which is usedto calculate the boiler's mass balance, or the unburned carbon loss is estimated and the mass balance of the boiler is calculated on the basis of boiler's heat balance. Both of the methods have their own weaknesses, so they were constructed parallel in the calculation and the decision of the used method was left to user. User also needs to define the used fuels and some solid mass flowsthat aren't measured automatically by the automation system. With sensitivity analysis was found that the most essential values for accurate boiler balance determination are flue gas oxygen content, the boiler's measured heat output and lower heating value of the fuel. The theoretical part of this work concentrates in the error management of these measurements and analyses and on measurement accuracy and boiler balance calculation in theory. The empirical part of this work concentrates on the creation of the balance calculation for the boiler in issue and on describing the work environment.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This work aimed the development and validation of a new dissolution test for ornidazole coated tablets. The dissolution conditions were determined after testing Sink conditions, dissolution medium, apparatus, stirring speed, 24 h stability and medium filtration influence. The best conditions were paddle at a stirring speed of 75 rpm and 900 mL of 0.1 M HCl. A new HPLC quantification method was developed and validated. The dissolution test and quantification method showed to be adequate for their purposes and could be applied for quality control of ornidazole coated tablets, since there is no official monograph.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A simple liquid chromatographic method was optimized for the quantitative determination of terbinafine in pharmaceutical hydroalcoholic solutions and tablets, and was also employed for a tablet dissolution test. The analysis was carried out using a RP-C18 (250 mm × 4.6 mm, 5 μm) Vertical® column, UV-Vis detection at 254 nm, and a methanol-water (95:5, v/v) mobile phase at a flow-rate of 1.2 mL min-1. Method validation investigated parameters such as linearity, precision, accuracy, robustness and specificity, which gave results within the acceptable range. The tablets dissolution was quite fast: 80% of the drug was dissolved within 15 min.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The objectives of the present study were 1) to compare results obtained by the traditional manual method of measuring heart rate (HR) and heart rate response (HRR) to the Valsalva maneuver, standing and deep breathing, with those obtained using a computerized data analysis system attached to a standard electrocardiograph machine; 2) to standardize the responses of healthy subjects to cardiovascular tests, and 3) to evaluate the response to these tests in a group of patients with diabetes mellitus (DM). In all subjects (97 healthy and 143 with DM) we evaluated HRR to deep breathing, HRR to standing, HRR to the Valsalva maneuver, and blood pressure response (BPR) to standing up and to a sustained handgrip. Since there was a strong positive correlation between the results obtained with the computerized method and the traditional method, we conclude that the new method can replace the traditional manual method for evaluating cardiovascular responses with the advantages of speed and objectivity. HRR and BPR of men and women did not differ. A correlation between age and HRR was observed for standing (r = -0.48, P<0.001) and deep breathing (r = -0.41, P<0.002). Abnormal BPR to standing was usually observed only in diabetic patients with definite and severe degrees of autonomic neuropathy.