930 resultados para TRANSMISSION-LINES
Resumo:
With the recent progress and rapid increase in the field of communication, the designs of antennas for small mobile terminals with enhanced radiation characteristics are acquiring great importance. Compactness, efficiency, high data rate capacity etc. are the major criteria for the new generation antennas. The challenging task of the microwave scientists and engineers is to design a compact printed radiating structure having broadband behavior along with good efficiency and enhanced gain. Printed antenna technology has received popularity among antenna scientists after the introduction of planar transmission lines in mid-seventies. When we view the antenna through a transmission line concept, the mechanism behind any electromagnetic radiator is quite simple and interesting. Any electromagnetic system with a discontinuity is radiating electromagnetic energy. The size, shape and orientation of the discontinuities control the radiation characteristics of the system such as radiation pattern, gain, polarization etc. It can be either resonant or non-resonant. This thesis deals with antennas that are developed from a class of transmission lines known as coplanar strip-CPS, a planar analogy of parallel pair transmission line. The specialty of CPS is its symmetric structure compared to other transmission lines, which makes the antenna structures developed from CPS quite simple for design and fabrication. The structural modifications on either metallic strip of CPS results in different antennas. The first part of the thesis discusses a single band and dual band design derived from open ended slot lines which are very much suitable for 2.4 and 5.2 GHz WLAN applications. The second section of the study is vectored into the development of enhanced gain dipoles. A single band dipole and a wide band enhanced gain dipole suitable for 5.2/5.8 GHZ band and imaging applications are developed and discussed. Last part of the thesis discusses the development of directional UWBs. Three different types of ultra-compact UWBs are developed and almost all the frequency domain and time domain analysis of the structures are discussed.
Resumo:
Fault location has been studied deeply for transmission lines due to its importance in power systems. Nowadays the problem of fault location on distribution systems is receiving special attention mainly because of the power quality regulations. In this context, this paper presents an application software developed in Matlabtrade that automatically calculates the location of a fault in a distribution power system, starting from voltages and currents measured at the line terminal and the model of the distribution power system data. The application is based on a N-ary tree structure, which is suitable to be used in this application due to the highly branched and the non- homogeneity nature of the distribution systems, and has been developed for single-phase, two-phase, two-phase-to-ground, and three-phase faults. The implemented application is tested by using fault data in a real electrical distribution power system
Resumo:
As fundações empregadas para linhas de transmissão de alta tensão em depósitos de argilas moles saturadas são geralmente estacas. No Rio Grande do Sul, projetos alternativos com fundações superficiais foram empregados em forma experimental para torres de suspensão, as quais apresentaram bom desempenho com menor custo. Esta pesquisa visa apontar critérios racionais da mecânica dos solos que permitam projetar, a partir do conhecimento do perfil de resistência não drenada, fundações superficiais em depósitos de argilas moles saturadas com maior confiabilidade. Para a determinaçao do perfil de resistência não drenada foi desenvolvido um cone manual com leituras elétricas, o qual foi testado apresentando bons resultados. A vantagem do uso deste equipamento reside no fato de que pode ser transportado manualmente a locais de difícil acesso, onde são implantadas as torres de alta tensão. Os demais parâmetros de solos do local de estudo, situado no município de Canoas no Rio Grande do Sul, foram obtidos a partir de ensaios de compressão triaxial do tipo adensado isotropicamente não drenado (CIU) com medida de poro pressão e de ensaios de adensamento. Foram analisadas as fundações superficiais das torres de suspensão projetadas, empregando teorias analíticas convencionais, baseadas no conhecimento da resistência não drenada, e o método de elementos finitos. A partir deste estudo, é sugerida uma metodologia para projetos de fundações superficiais de torres de suspensão em argilas moles saturadas.
Resumo:
A presente tese engloba cinco trabalhos sobre dois setores brasileiros de infraestrutura: setor de energia e de transportes. No primeiro trabalho, modela-se o lance dos leilões de linhas de transmissão de energia, buscando compreender porque os lances ganhadores têm se situado em níveis abaixo do que se espera. No segundo paper, estima-se a demanda de energia do Brasil e as elasticidades preço e renda que os consumidores apresentem em relação a essa demanda, usando uma técnica ainda não aplicada na literatura e incluindo o período da Crise do Racionamento – a qual pode ter mudado o padrão de consumo dos agentes. No terceiro trabalho, estuda-se a evolução do mercado de gás natural liquefeito (GNL) ao redor do mundo. O GNL pode ser o link que faltava entre os mercados de gás natural e essa hipótese é testada por meio de análises de séries de tempo e de cópulas. O quarto paper discute a entrada do GNL no sistema energético brasileiro e suas eventuais consequências. Por fim, o quinto paper analisa a experiência de leilões de rodovias no Brasil. O trabalho levanta relevantes insights a respeito do modelo de leilão utilizado e dos detalhes contratuais dessas licitações.
Resumo:
Eventually, violations of voltage limits at buses or admissible loadings of transmission lines and/or power transformers may occur by the power system operation. If violations are detected in the supervision process, corrective measures may be carried out in order to eliminate them or to reduce their intensity. Loading restriction is an extreme solution and should only be adopted as the last control action. Previous researches have shown that it is possible to control constraints in electrical systems by changing the network topology, using the technique named Corrective Switching, which requires no additional costs. In previous works, the proposed calculations for verifying the ability of a switching variant in eliminating an overload in a specific branch were based on network reduction or heuristic analysis. The purpose of this work is to develop analytical derivation of linear equations to estimate current changes in a specific branch (due to switching measures) by means of few calculations. For bus-bar coupling, derivations will be based on short-circuit theory and Relief Function methodology. For bus-bar splitting, a Relief Function will be derived based on a technique of equivalent circuit. Although systems of linear equations are used to substantiate deductions, its formal solution for each variant, in real time does not become necessary. A priority list of promising variants is then assigned for final check by an exact load flow calculation and a transient analysis using ATP Alternative Transient Program. At last, results obtained by simulation in networks with different features will be presented
Resumo:
This work presents a theoretical and numerical analysis using the transverse resonance technique (TRT) and a proposed MTRT applied in the analysis of the dispersive characteristics of microstrip lines built on truncated isotropic and anisotropic dielectric substrates. The TRT uses the transmission lines model in the transversal section of the structure, allowing to analyze its dispersive behavior. The difference between TRT and MTRT consists basically of the resonance direction. While in the TRT the resonance is calculated in the same direction of the metallic strip normal axis, the MTRT considers the resonance in the metallic strip parallel plane. Although the application of the MTRT results in a more complex equivalent circuit, its use allows some added characterization, like longitudinal section electric mode (LSE) and longitudinal section magnetic mode (LSM), microstrips with truncated substrate, or structures with different dielectric regions. A computer program using TRT and MTRT proposed in this work is implemented for the characterization of microstrips on truncated isotropic and anisotropic substrates. In this analysis, propagating and evanescent modes are considered. Thus, it is possible to characterize both the dominant and higher order modes of the structure. Numerical results are presented for the effective permittivity, characteristic impedance and relative phase velocity for microstrip lines with different parameters and dimensions of the dielectric substrate. Agreement with the results obtained in the literature are shown, as well as experimental results. In some cases, the convergence analysis is also performed by considering the limiting conditions, like particular cases of isotropic materials or structures with dielectric of infinite size found in the literature. The numerical convergence of the formulation is also analyzed. Finally, conclusions and suggestions for the continuity of this work are presented
Resumo:
The Methods for compensation of harmonic currents and voltages have been widely used since these methods allow to reduce to acceptable levels the harmonic distortion in the voltages or currents in a power system, and also compensate reactive. The reduction of harmonics and reactive contributes to the reduction of losses in transmission lines and electrical machinery, increasing the power factor, reduce the occurrence of overvoltage and overcurrent. The active power filter is the most efficient method for compensation of harmonic currents and voltages. The active power filter is necessary to use current and voltage controllers loop. Conventionally, the current and voltage control loop of active filter has been done by proportional controllers integrative. This work, investigated the use of a robust adaptive control technique on the shunt active power filter current and voltage control loop to increase robustness and improve the performance of active filter to compensate for harmonics. The proposed control scheme is based on a combination of techniques for adaptive control pole placement and variable structure. The advantages of the proposed method over conventional ones are: lower total harmonic distortion, more flexibility, adaptability and robustness to the system. Moreover, the proposed control scheme improves the performance and improves the transient of active filter. The validation of the proposed technique was verified initially by a simulation program implemented in C++ language and then experimental results were obtained using a prototype three-phase active filter of 1 kVA
Resumo:
The electric energy is essential to the development of modern society and its increasing demand in recent years, effect from population and economic growth, becomes the companies more interested in the quality and continuity of supply, factors regulated by ANEEL (Agência Nacional de Energia Elétrica). These factors must be attended when a permanent fault occurs in the system, where the defect location that caused the power interruption should be identified quickly, which is not a simple assignment because the current systems complexity. An example of this occurs in multiple terminals transmission lines, which interconnect existing circuits to feed the demand. These transmission lines have been adopted as a feasible solution to suply loads of magnitudes that do not justify economically the construction of new substations. This paper presents a fault location algorithm for multiple terminals transmission lines - two and three terminals. The location method is based on the use of voltage and current fundamental phasors, as well as the representation of the line through its series impedance. The wavelet transform is an effective mathematical tool in signals analysis with discontinuities and, therefore, is used to synchronize voltage and current data. The Fourier transform is another tool used in this work for extract voltage and current fundamental phasors. Tests to validate the location algorithm applicability used data from faulty signals simulated in ATP (Alternative Transients Program) as well as real data obtained from oscillographic recorders installed on CHESF s lines.
Resumo:
This work presents a theoretical analysis and numerical and experimental results of the scattering characteristics of frequency selective surfaces, using elements of type patch perfectly conductor. The structures are composed of two frequency selective surfaces on isotropic dielectric substrates cascaded, separated by a layer of air. The analysis is performed using the method of equivalent transmission line in combination with the Galerkin method, to determine the transmission and reflection characteristics of the structures analyzed. Specifically, the analysis uses the impedance method, which models the structure by an equivalent circuit, and applies the theory of transmission lines to determine the dyadic Green's function for the cascade structure. This function relates the incident field and surface current densities. These fields are determined algebraically by means of potential incidents and the imposition of the continuity of the fields in the dielectric interfaces. The Galerkin method is applied to the numerical determination of the unknown weight coefficients and hence the unknown densities of surface currents, which are expanded in terms of known basis functions multiplied by these weight coefficients. From the determination of these functions, it becomes possible to obtain numerical scattered fields at the top and bottom of the structures and characteristics of transmission and reflection of these structures. At work, we present numerical and experimental results for the characteristics of transmission and reflection. Comparisons were made with other results presented in literature, and it was observed a good agreement in the cases presented suggestions continuity of the work are presented
Resumo:
Recently, an amazing development has been observed in telecommunication systems. Two good examples of this development are observed in mobile communication and aerospace systems. This impressive development is related to the increasing need for receiving and transmitting communication signals. Particularly, this development has required the study of new antennas and filters. This work presents a fullwave analysis of reflectarrays. The considered structures are composed by arrays of rectangular conducting patches printed on multilayer dieletric substrates, that are mounted on a ground plane. The analysis is developed in the spectral domain, using an equivalent transmission line method in combination with Galerkin method. Results for the reflection coefficient of these structures are presented and compared to those available in the literature. A good agreement was observed. Particularly, the developed analysis uses the transmission lines theory in combination with the incident potentials and the field continuity equations, at the structures interfaces, for obtaining the scattered field components expressions as function of the patch surface currents and of the incident field. Galerkin method is used to determine the unknown coefficients in the boundary value problem. Curves for the reflection coefficient of several reflectarray geometries are presented as function of frequency and of the structural parameters
Resumo:
In this work, the transmission line method is explored on the study of the propagation phenomenon in nonhomogeneous walls with finite thickness. It is evaluated the efficiency and applicability of the method, considering materials like gypsum, wood and brick, found in the composition of the structures of walls in question. The results obtained in this work are compared to those available in the literature, for several particular cases. A good agreement is observed, showing that the performed analysis is accurate and efficient in modeling, for instance, the wave propagation through building walls and integrated circuit layers in mobile communication and radar system applications. Later, simulations of resistive sheets devices such as Salisbury screens and Jaumann absorbers and of transmission lines made of metal-insulator-semiconductor (MIS) are made. Thereafter, it is described a study on frequency surface selective structures (FSS). It is proposed the development of devices and microwave integrated circuits (MIC) of such structures, for the accomplishment of experiments. Finally, future works are suggested, for instance, on the development of reflectarrays, frequency selective surfaces with dissimilar elements, and coupled frequency selective surfaces with elements located on different layers
Resumo:
This work presents in a simulated environment, to analyze the length of cable needed counterweight connected to ground rod, able to avoid the phenomenon of flashover return, back flashover, the insulator chains of transmission lines consisting of concrete structures when they are subjected to lightning standardized regarding certain resistivity values of some kinds of soil and geometric arrangements of disposal of grounding systems structures
Resumo:
This work proposes a new technique for phasor estimation applied in microprocessor numerical relays for distance protection of transmission lines, based on the recursive least squares method and called least squares modified random walking. The phasor estimation methods have compromised their performance, mainly due to the DC exponential decaying component present in fault currents. In order to reduce the influence of the DC component, a Morphological Filter (FM) was added to the method of least squares and previously applied to the process of phasor estimation. The presented method is implemented in MATLABr and its performance is compared to one-cycle Fourier technique and conventional phasor estimation, which was also based on least squares algorithm. The methods based on least squares technique used for comparison with the proposed method were: forgetting factor recursive, covariance resetting and random walking. The techniques performance analysis were carried out by means of signals synthetic and signals provided of simulations on the Alternative Transient Program (ATP). When compared to other phasor estimation methods, the proposed method showed satisfactory results, when it comes to the estimation speed, the steady state oscillation and the overshoot. Then, the presented method performance was analyzed by means of variations in the fault parameters (resistance, distance, angle of incidence and type of fault). Through this study, the results did not showed significant variations in method performance. Besides, the apparent impedance trajectory and estimated distance of the fault were analysed, and the presented method showed better results in comparison to one-cycle Fourier algorithm
Análise espectral de reflectarrays com substrato de duas camadas dielétricas anisotrópicas uniaxiais
Resumo:
Recently, an amazing development has been observed in telecommunication systems. Two good examples of this development are observed in mobile communication and aerospace systems. This impressive development is related to the increasing need for receiving and transmitting communication signals. Particularly, this development has required the study of new antennas and filters. This work presents a fullwave analysis of reflectarrays. The considered structures are composed by arrays of rectangular conducting patches printed on multilayer dieletric substrates, that are mounted on a ground plane. The analysis is developed in the spectral domain, using an equivalent transmission line method in combination with Galerkin method. Results for the reflection coefficient of these structures are presented and compared to those available in the literature. A good agreement was observed. Particularly, the developed analysis uses the transmission lines theory in combination with the incident potentials and the field continuity equations, at the structures interfaces, for obtaining the scattered field components expressions as function of the patch surface currents and of the incident field. Galerkin method is used to determine the unknown coefficients in the boundary value problem. Curves for the reflection coefficient of several reflectarray geometries are presented as function of frequency and of the structural parameters
Resumo:
The conventional Newton's method has been considered inadequate to obtain the maximum loading point (MLP) of power systems. It is due to the Jacobian matrix singularity at this point. However, the MLP can be efficiently computed through parameterization techniques of continuation methods. This paper presents and tests new parameterization schemes, namely the total power losses (real and reactive), the power at the slack bus (real or reactive), the reactive power at generation buses, the reactive power at shunts (capacitor or reactor), the transmission lines power losses (real and reactive), and transmission lines power (real and reactive). Besides their clear physical meaning, which makes easier the development and application of continuation methods for power systems analysis, the main advantage of some of the proposed parameters is that its not necessary to change the parameter in the vicinity of the MLP. Studies on the new parameterization schemes performed on the IEEE 118 buses system show that the ill-conditioning problems at and near the MLP are eliminated. So, the characteristics of the conventional Newton's method are not only preserved but also improved. (C) 2003 Elsevier B.V. B.V. All rights reserved.