276 resultados para TRANSARTERIAL EMBOLIZATION
Resumo:
INTRODUCTION Evidence-based recommendations can be made with respect to many aspects of the acute management of the bleeding trauma patient, which when implemented may lead to improved patient outcomes. METHODS The multidisciplinary Task Force for Advanced Bleeding Care in Trauma was formed in 2005 with the aim of developing guidelines for the management of bleeding following severe injury. Recommendations were formulated using a nominal group process and the GRADE (Grading of Recommendations Assessment, Development, and Evaluation) hierarchy of evidence and were based on a systematic review of published literature. RESULTS Key recommendations include the following: The time elapsed between injury and operation should be minimised for patients in need of urgent surgical bleeding control, and patients presenting with haemorrhagic shock and an identified source of bleeding should undergo immediate surgical bleeding control unless initial resuscitation measures are successful. A damage control surgical approach is essential in the severely injured patient. Pelvic ring disruptions should be closed and stabilised, followed by appropriate angiographic embolisation or surgical bleeding control, including packing. Patients presenting with haemorrhagic shock and an unidentified source of bleeding should undergo immediate further assessment as appropriate using focused sonography, computed tomography, serum lactate, and/or base deficit measurements. This guideline also reviews appropriate physiological targets and suggested use and dosing of blood products, pharmacological agents, and coagulation factor replacement in the bleeding trauma patient. CONCLUSION A multidisciplinary approach to the management of the bleeding trauma patient will help create circumstances in which optimal care can be provided. By their very nature, these guidelines reflect the current state-of-the-art and will need to be updated and revised as important new evidence becomes available.
Resumo:
Transapical aortic valve replacement through an apical aneurysm is traditionally contraindicated because of the risk of severe systemic embolization when thrombi are present. However, a chronic fibrotic aneurysm without apical thrombi carries a low risk of distal embolization and can be safely employed for a transapical transcatheter aortic valve replacement in case of absence of an alternative access site (severe vascular disease, small vascular sizes and diseased calcified aorta). We illustrate our experience with a 73-year-old patient suffering from symptomatic aortic valve stenosis, coronary artery disease with occluded left anterior descending artery, left ventricular apical aneurysm and severe peripheral vascular disease, who successfully underwent a transapical 26 mm Sapien? XT stent-valve implantation through the fibrotic thin akinetic apical wall.
Resumo:
BACKGROUND AND PURPOSE: Management of brain arteriovenous malformation (bAVM) is controversial. We have analyzed the largest surgical bAVM cohort for outcome. METHODS: Both operated and nonoperated cases were included for analysis. A total of 779 patients with bAVMs were consecutively enrolled between 1989 and 2014. Initial management recommendations were recorded before commencement of treatment. Surgical outcome was prospectively recorded and outcomes assigned at the last follow-up visit using modified Rankin Scale. First, a sensitivity analyses was performed to select a subset of the entire cohort for which the results of surgery could be generalized. Second, from this subset, variables were analyzed for risk of deficit or near miss (intraoperative hemorrhage requiring blood transfusion of ≥2.5 L, hemorrhage in resection bed requiring reoperation, and hemorrhage associated with either digital subtraction angiography or embolization). RESULTS: A total of 7.7% of patients with Spetzler-Ponce classes A and B bAVM had an adverse outcome from surgery leading to a modified Rankin Scale >1. Sensitivity analyses that demonstrated outcome results were not subject to selection bias for Spetzler-Ponce classes A and B bAVMs. Risk factors for adverse outcomes from surgery for these bAVMs include size, presence of deep venous drainage, and eloquent location. Preoperative embolization did not affect the risk of perioperative hemorrhage. CONCLUSIONS: Most of the ruptured and unruptured low and middle-grade bAVMs (Spetzler-Ponce A and B) can be surgically treated with a low risk of permanent morbidity and a high likelihood of preventing future hemorrhage. Our results do not apply to Spetzler-Ponce C bAVMs.
Resumo:
INTRODUCTION: Evidence-based recommendations are needed to guide the acute management of the bleeding trauma patient. When these recommendations are implemented patient outcomes may be improved. METHODS: The multidisciplinary Task Force for Advanced Bleeding Care in Trauma was formed in 2005 with the aim of developing a guideline for the management of bleeding following severe injury. This document represents an updated version of the guideline published by the group in 2007 and updated in 2010. Recommendations were formulated using a nominal group process, the Grading of Recommendations Assessment, Development and Evaluation (GRADE) hierarchy of evidence and based on a systematic review of published literature. RESULTS: Key changes encompassed in this version of the guideline include new recommendations on the appropriate use of vasopressors and inotropic agents, and reflect an awareness of the growing number of patients in the population at large treated with antiplatelet agents and/or oral anticoagulants. The current guideline also includes recommendations and a discussion of thromboprophylactic strategies for all patients following traumatic injury. The most significant addition is a new section that discusses the need for every institution to develop, implement and adhere to an evidence-based clinical protocol to manage traumatically injured patients. The remaining recommendations have been re-evaluated and graded based on literature published since the last edition of the guideline. Consideration was also given to changes in clinical practice that have taken place during this time period as a result of both new evidence and changes in the general availability of relevant agents and technologies. CONCLUSIONS: A comprehensive, multidisciplinary approach to trauma care and mechanisms with which to ensure that established protocols are consistently implemented will ensure a uniform and high standard of care across Europe and beyond.
Resumo:
Ophthalmoplegia associated with dural carotid-cavernous sinus fistula typically involves the third, fourth, and sixth cranial nerves. Occasionally, isolated palsy of the oculomotor or abducens nerve is noted. We report a patient with bilateral dural carotid-cavernous sinus fistulas who presented with an isolated trochlear nerve palsy.
Resumo:
Background: We demonstrated that DC Bead (Biocompatibles UK, Ltd) could be loaded with sunitinib and injected intra-arterially in the rabbit without unexpected toxicity. The purpose of this study is to evaluate the antitumoral effect of sunitinib eluting beads in the VX2 tumor model of liver cancer. Methods: VX2 tumors were implanted in the left liver lobe of New-Zealand white rabbits. Animals were assigned to 3 groups: Group 1 (n=6) received 1.5mg of sunitinib loaded in 0.05ml of 100-300um DC Bead, group 2 (n=5) received 0.05ml of 100-300um DC Bead, group 3 (n=5) received 0.05ml NaCl 0.9% in the left hepatic artery. One animal in each group was sacrificed at 24 hours and the others were followed for survival until day 15. Liver enzymes were measured daily. In group 1, plasmatic sunitinib concentration were measured daily by LC MS/MS tandem mass spectroscopy. At day 15 all living animals were sacrificed. After sacrifice, the livers were harvested for determination of the VEGF receptor tyrosine kinase activity by western blot and histopathological examination. Results: In group 1, no animals died during follow-up. In group 2, 2 animals died during follow-up on day x. In control group 3, 3 animals died during follow up on day x. In group 1 plasmatic sunitinib levels remained under therapeutic concentration throughout the experiment. Very high concentrations of sunitinib were measured in the liver tissue 24 and 15 days after embolization. Inhibition of the phosphorylation of the RTK was demonstrated at 24h and 15 days in groups 1. Sunitinib eluting beads seemed to penetrate in the tumor more effectively and there was more necrosis around the beads than their bland counterparts. Conclusions: Administration of sunitinib eluting beads in VX2 carrying rabbits resulted invery high drug concentrations at the site of embolization with minimal systemic passage. Despite the very high tissular sunitinib concentration we did not observe any additional toxicity with loaded beads. Sunitinib eluting beads inhibit the activation of RTK's triggered by ischemia and seem to prolong survival of the treated animals. Therefore we consider that local treatment with sunitinib may provide a promising approach for the treatment of liver cancer.
Resumo:
Arteriovenous malformations (AVMs) may be cured by injecting liquid embolic agents such as Onyx. Reflux, however, can sometimes be difficult to control and may jeopardize a complete embolization. The pressure cooker technique (PCT) was designed to create an anti-reflux plug by trapping the detachable part of an Onyx-compatible microcatheter with coils and glue in order to obtain wedge-flow conditions, thereby enabling a better understanding of macrofistulous AVMs and a more comprehensive, forceful and controlled Onyx embolization. The PCT might enlarge the range of AVMs amenable to endovascular cure. Three illustrative cases are presented.
Resumo:
OBJECTIVE. The purpose of our study was to evaluate hepatic, gastrointestinal, and cardiac toxicity after PRECISION transarterial chemoembolization (TACE) with drug-eluting beads (DEB) versus conventional TACE with doxorubicin in the treatment of intermediate-stage hepatocellular carcinoma (HCC).SUBJECTS AND METHODS. Two hundred twelve patients (185 men and 27 women; mean age, 67 years) were randomized to TACE with DEB or conventional TACE. The majority of patients (67% in both groups) presented in a more advanced stage. Safety was measured by rate of adverse events (Southwest Oncology Group criteria) and changes in laboratory parameters. Cardiotoxicity was assessed with left ventricular ejection fraction (LVEF) mainly on MRI or echocardiography.RESULTS. The mean maximum postchemoembolization alanine transaminase increase in the DEB group was 50% less than in the conventional TACE group (p < 0.001) and 41% less in respect to aspartate transaminase (p < 0.001). End-of-study values returned to approximately baseline levels but with greater variability in conventional TACE patients. Treatment-emergent adverse events in the hepatobiliary system organ class occurred in 16.1% of DEB group patients compared with 25% of conventional TACE patients. There were fewer liver toxicity events in the DEB group. There was a small but statistically significant difference in mean change from baseline in LVEF between the two groups of 4 percentage points for the conventional TACE group (95% CI, 0.71-7.3; p = 0.018).CONCLUSION. PRECISION TACE with DEB loaded with doxorubicin offers a safe therapy option for intermediate-stage HCC, even in patients with more advanced liver disease.
Resumo:
OBJECTIVE: To highlight the clinical presentation, investigation and treatment of haemorrhage into the pancreatic duct. DESIGN: Retrospective study and review of publications. SETTING: University hospital, Switzerland. SUBJECTS: All 4 cases from 1972 to 1993. INTERVENTIONS: 2 Whipple procedures, 1 resection of the pancreatic head, 1 exploratory laparotomy. Radiological embolisation in one case. MAIN OUTCOME MEASURES: Cessation of haemorrhage and survival. RESULTS: The diagnosis was made preoperatively in three cases by gastroduodenoscopy and arteriography. Operation was the primary treatment in all patients and was effective with low morbidity and no mortality in three of them. Embolisation stopped the haemorrhage in the fourth patient, who was alcoholic and died of progressive liver insufficiency and variceal haemorrhage. CONCLUSIONS: There is no specific indication for haemorrhage into the pancreatic duct. The diagnosis is suggested by endoscopy (absence of a more common cause, or blood in the second part of the duodenum). Arteriography is essential to confirm the site of the bleeding and to attempt embolization. Operation is usually the definitive treatment.
Resumo:
Background: Cardiac computed tomographic scans, coronary angiograms, and aortographies are routinely performed in transcatheter heart valve therapies. Consequently, all patients are exposed to multiple contrast injections with a following risk of nephrotoxicity and postoperative renal failure. The transapical aortic valve implantation without angiography can prevent contrast-related complications. Methods: Between November 2008 and November 2009, 30 consecutive high-risk patients (16 female, 53.3%) underwent transapical aortic valve implantation without angiography. The landmarks identification, the stent-valve positioning, and the postoperative control were routinely performed under transesophageal echocardiogram and fluoroscopic visualization without contrast injections. Results: Mean age was 80.1 +/- 8.7 years. Mean valve gradient, aortic orifice area, and ejection fraction were 60.3 +/- 20.9 mm Hg, 0.7 +/- 0.16 cm(2), and 0.526 +/- 0.128, respectively. Risk factors were pulmonary hypertension (60%), peripheral vascular disease (70%), chronic pulmonary disease (50%), previous cardiac surgery (13.3%), and chronic renal insufficiency (40%) (mean blood creatinine and urea levels: 96.8 +/- 54 mu g/dL and 8.45 +/- 5.15 mmol/L). Average European System for Cardiac Operative Risk Evaluation was 32.2 +/- 13.3%. Valve deployment in the ideal landing zone was 96.7% successful and valve embolization occurred once. Thirty-day mortality was 10% (3 patients). Causes of death were the following: intraoperative ventricular rupture (conversion to sternotomy), right ventricular failure, and bilateral pneumonia. Stroke occurred in one patient at postoperative day 9. Renal failure (postoperative mean blood creatinine and urea levels: 91.1 +/- 66.8 mu g/dL and 7.27 +/- 3.45 mmol/L), myocardial infarction, and atrioventricular block were not detected. Conclusions: Transapical aortic valve implantation without angiography requires a short learning curve and can be performed routinely by experienced teams. Our report confirms that this procedure is feasible and safe, and provides good results with low incidence of postoperative renal disorders. (Ann Thorac Surg 2010; 89: 1925-33) (C) 2010 by The Society of Thoracic Surgeons
Resumo:
OBJECTIVES: During open heart surgery, so-called atrial chatter, a phenomenon due to right atria and/or caval collapse, is frequently observed. Collapse of the cava axis during cardiopulmonary bypass (CPB) limits venous drainage and may result downstream in reduced pump flow on (lack of volume) and upstream in increased after-load (stagnation), which in turn may both result in reduced or even inadequate end-organ perfusion. The goal of this study was to reproduce venous collapse in the flow bench. METHODS: In accordance with literature for venous anatomy, a caval tree system is designed (polyethylene, thickness 0.061 mm), which receives venous inflow from nine afferent veins. With water as medium and a preload of 4.4 mmHg, the system has an outflow of 4500 ml/min (Scenario A). After the insertion of a percutaneous venous cannula (23-Fr), the venous model is continuously served by the afferent branches in a venous test bench and venous drainage is augmented with a centrifugal pump (Scenario B). RESULTS: With gravity drainage (siphon: A), spontaneously reversible atrial chatter can be generated in reproducible fashion. Slight reduction in the outflow diameter allows for generation of continuous flow. With augmentation (B), irreversible collapse of the artificial vena cava occurs in reproducible fashion at a given pump speed of 2300 ± 50 RPM and a pump inlet pressure of -112 mmHg. Furthermore, bubbles form at the cannula tip despite the fact that the entire system is immersed in water and air from the environment cannot enter the system. This phenomenon is also known as cavitation and should be avoided because of local damage of both formed blood elements and endothelium, as well embolization. CONCLUSIONS: This caval model provides a realistic picture for the limitations of flow due to spontaneously reversible atrial chatter vs irreversible venous collapse for a given negative pressure during CPB. Temporary interruption of negative pressure in the venous line can allow for recovery of venous drainage. This know-how can be used not only for testing different cannula designs, but also for further optimizing perfusion strategies.
Resumo:
Purpose To characterize in vitro the loadability, physical properties, and release of irinotecan and doxorubicin from two commercially available embolization microspheres. Materials and Methods DC Bead (500-700 μm) and Hepasphere (400-600 μm) microspheres were loaded with either doxorubicin or irinotecan solutions. Drug amount was quantified with spectrophotometry, bead elasticity was measured under compression, and bead size and loading homogeneity were assessed with microscopy image analysis. Drug release was measured over 1-week periods in saline by using a pharmacopeia flow-through method. Results Almost complete drug loading was obtained for both microsphere types and drugs. Doxorubicin-loaded DC Beads maintained their spherical shape throughout the release. In contrast, Hepaspheres showed less homogeneous doxorubicin loading and, after release, some fractured microspheres. Incomplete doxorubicin release was observed in saline over 1 week (27% ± 2 for DC beads and 18% ± 7 for Hepaspheres; P = .013). About 75% of this amount was released within 2.2 hours for both beads. For irinotecan, complete release was obtained for both types of beads, in a sustained manner over 2-3 hours for DC Beads, and in a significantly faster manner as a 7-minute burst for Hepaspheres. Conclusions The two drug-eluting microspheres could be efficiently loaded with both drugs. Incomplete doxorubicin release was attributed to strong drug-bead ionic interactions. Weaker interactions were observed with irinotecan, which led to faster drug release.
Resumo:
The prevalence of insulin-dependent diabetes mellitus (IDDM) in cystic fibrosis patients ranges from 2 to 8% and glucose intolerance up to 15%. In recent years, lung transplantation has helped to prolong life expectancy of cystic fibrosis patients and represents 10 to 30% of all indications for lung transplantation. The postoperative need for immunosuppressive therapy using diabetogenic agents has decompensatory effects on glucose regulation and will probably increase the number of insulin-dependent cystic fibrosis patients. We report the case of an insulin-dependent cystic fibrosis patient transplanted with a combined islet-lung allograft. The pre-transplantation C-peptide level was below 0.04 nmol/l and preoperative insulin requirement was some 100 U per day. A sequential bipulmonary lung transplantation was performed and, using the pancreas of the same donor, we isolated and purified the islets of Langerhans by a modified automated method. We obtained 232,200 islets equivalent, which were injected into the liver by portal embolization. The postoperative course was uncomplicated, the insulin requirement decreased to 50% of the preoperative need and the C-peptide value increased to normal values and remained with the normal range during a follow-up period of 15 months. In conclusion, we believe that, besides type I diabetic patients, insulin-dependent cystic fibrosis patients with a negative C-peptide value could also be good candidates for combined islet-lung allotransplantation.
Resumo:
Purpose: To study the pharmacokinetics and potential toxicity of sunitinib eluting beads in an animal modelMaterials: Healthy New-Zealand white rabbits were used. 8 animals received 0.2ml of DC Beads loaded with 6mg of sunitinb intra arterially in the hepatic artery (group 1) and 4 animals received 6mg of sunitinib administered orally (group 2). In group 1, animals were sacrificed 6 hours (n=4) and 24 hours (n=4) after embolization. In group 2, animals were sacrificed 6 hours (n=2) and 24 hours (n=2) after oral administration of sunitinib. Liver enzymes were measured at 0, 6 and 24 hours in both groups. Plasmatic sunitinib concentration was measured by LC MS/MS tandem mass spectroscopy at 0, 1, 2, 3, 4, 5, 6 and 24 hours. At sacrifice, the livers were harvested and sunitinib concentration in liver tissue was assessed by LC MS/MS tandem mass spectroscopy.Results: After embolization we observed an expected elevation of AST and ALT. Serial plasmatic measurments after embolization showed a very low sunitinib concentration (<50ng/ml). Measurment of sunitinib in the embolized liver tissue showed a very high concentration at 6 hours (3870ng/ml) and 24 hours (4741.7ng/ml).Conclusions: Sunitinib eluting beads are well tolerated by rabbits when administered intra-arterially in the hepatic artery. No unexpected toxicity was observed. Very high drug concentration canbe obtained at the site of embolization with minimal systemic passage.