175 resultados para Tíbia
Resumo:
Titanium has proven its suitability as an implant material in surgery over many years. Excellent biocompatibility and corrosion resistance are outstanding features. Implant surfaces always causes concern and interest in scientific communities, due to its close relationship with the time required for osseointegration. Surface modification can be performed by several methods, being laser irradiation one of them. Titanium implants with two different surfaces were inserted in rabbits: Group I (G-I: machined surface, control group), and group II (G-II: laser irradiated, test group) being processed 30 and 60 days after surgery for histological analysis. Surface characterization was performed with SEM-EDS, contact angle measurement, and mean roughness (Ra) parameters. Surface analysis in the GII group showed a nanomorphology affected by melt and quick solidification zones following laser irradiation (SEM), as well as total wettability and Ra mean values significantly higher than in the G-I group. The laser treatment resulted in a homogenized, porous surface, with increased surface area and volume. Histological analysis of bone-implant contact linear extension (BIC) showed better results in G-II at 30 days (39.26 ± 18.23 and 68.41 ± 13.68 for G-I and G-II groups, respectively). Titanium implants modified by laser irradiation showed important features that may accelerate early osseointegration.
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
A guinea pig was presented with left pelvic limb lameness after unknown trauma. Radiographs revealed complete oblique diaphyseal fracture of the distal third of the left tibia and fibula. The guinea pig was treated surgically with an intramedullary pin. The day after surgery the guinea pig was using the limb comfortably (grade 1/5 lameness). Callus formation was obtained 21 days after surgery without complications.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Odontologia - FOA
Resumo:
The purpose of this study was to analyze the bone repair around commercially pure titanium implants with rough and porous surface, fabricated using powder metallurgy technique, after their insertion in tibiae of rabbits. Seven male rabbits were used. Each animal received 3 porous-surface implants in the left tibia and 3 rough-surface implants in the right tibia. The rabbits were sacrificed 4 weeks after surgery and fragments of the tibiae containing the implants were submitted to histological and histomorphometric analyses to evaluate new bone formation at the implant-bone interface. Means (%) of bone neoformation obtained in the histomorphometric analysis were compared by Student's t-test for paired samples at 5% significance level.. The results of the histological analysis showed that osseointegration occurred for both types of implants with similar quality of bone tissue. The histomorphometric analysis revealed means of new bone formation at implant-bone interface of 79.69 ± 1.00% and 65.05 ± 1.23% for the porous- and rough-surface implants, respectively. Statistically significant difference was observed between the two types of implants with respect to the amount new bone formation (p<0.05). In conclusion, the porous-surface implants contributed to the osseointegration because they provide a larger contact area at implant-bone interface.
Resumo:
Pós-graduação em Alimentos e Nutrição - FCFAR
Resumo:
Pós-graduação em Ciência Animal - FMVA
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The response of bone metabolism is directly related to hormonal factors and mechanical stimuli that the bone is exposed. The ultrasonic energy on bone healing have been shown to be crucial for the stimulation and improvement in quality of newly formed tissue. The aim of this study was to analyze the action of low intensity ultrasound on bone healing of tibial osteotomy in rats subjected to tail suspension, through histological analysis and histomorphometry. Eighteen Rattus norvegicus albinos, Wistar, adults were divided into three groups, arranged as follows: G1 (n = 6), who remained free for a period of 15 days, G2 (n = 5), suspended by the tail for a period of 15 days and G3 (n = 7), suspended by the tail for a period of 36 days. In all three groups, both tibias were subjected to mono-cortical bone injury 4X2 mm in the medial region of the diaphysis, and the left limb was used as control and the right limb undergoing treatment with ultrasound (U.S.). The right tibia was treated with pulsed ultrasound at a frequency of 1.5 MHz, duty cycle 1:4, 30mW/cm2, for 12 sessions of 20 minutes each. Samples of tibia were subjected to histological analysis, blindly, with light microscopy and histomorphometric analysis by specific software Image-Pro 6.1. The average percentage of new bone formation were subjected to analysis of variance in subdivided parcels and multiple comparison test "Student-Newman-Keuls (SNK), with a significance level of 5%. The average values and standard deviations of the percentage of newly formed bone for the groups showed the least amount of bone repair G1t (13.62% ± 4.88%) - G1c (8.68% ± 4.16%) compared G2t groups (27.17% ± 11.36%) - G2c (10.10% ± 7.90%) and G3t (23.19% ± 5.61%) - G3c (15.74% ± 7 08%). However, the mean values and standard deviations of the percentage of newly formed bone repair in the tibia treated G2t and G3t were significantly higher when compared to the repair of tibia in the control group (G2c and G3c). Consequently, we conclude that ultrasound has helped to accelerate bone repair in both the presence and absence of cargo.
Resumo:
Low-intensity laser has been used as a physical agent in various fields of medical sciences such as bone and tissue repair. Meanwhile little is known about its effects in adverse conditions such as abolition of load and osteopenic. With the assumption that the laser Ga-Al-As accelerates the process of bone consolidation, goal of this study was to evaluate bone mineral density (BMD) in incomplete transverse osteotomies of tibia in adult rats, treated with low power laser therapy in three different groups: G1 (n = 10), reference 15 days; G2 (n=10), suspended by the tail and, accordingly, treated with laser for 12 days; G3 (n = 10), suspended by the tail by 36 days and that after 21 days, there was laser treatment for 12 days. The right tibia treated with laser and left served as control. The laser was used to Ga-Al-As, DMC - Flash Lase® III, with wavelength 830nm, 100 mW, 4J, 140 J / cm ², 40s of application in 12 sessions. It was used densitometer-Lunar DPX®, with computer program for "small animals", and the analysis of BMD was made in the bone throughout the region and the osteotomy. The results showed no efficacy of laser therapy in the process of bone repair, both in animals of group 1, as in group 2 and 3. It follows that either the low-power laser was not an effective performance or the effects of laser therapy is not only manifested at the site of irradiation as well as the systemic level.
Resumo:
Background: The principles of tissue regeneration to repair alveolar bone defects are based on the fabrication of a biologic barrier with different biomaterials. Therefore, the present study aimed to investigate the guided bone regeneration (GBR) by using membrane of demineralized bovine bone matrix (DBBM) on experimental defects in tibia of dogs. Methods: Four dogs were used and after anesthesia, shaving and antisepsis, two standardized bone defects were created on the right tibia of each animal with trephine drill. In the Control Group, the defects were filled with blood coagulum, while in the Treated Group, a membrane of DBBM was used to cover the defects. After 90 days, animals were sacrificed. Results: In the Treated Group, 67.4% of new bone formation was observed and, in the Control Group, 32.6% of the bone tissue reabsorbed when compared with initial bone volume. The membrane remained intact and no inflammatory tissue was observed on membrane/ bone interface. Conclusion: It was concluded that the use of DBBM is an osteoconductive material, presents biocompatibility and may be promise option to repair bone defects.
Resumo:
Studies have reported that alcohol may lead to imbalance in bone formation and resorption, however, its effects on osseointegration of titanium implants continues to be an inconclusive subject. In this context, the aim of this study was to make a biomechanical evaluation of the effect of abusive alcohol consumption on the removal torque of osseointegrated titanium implants. Male Wistar rats (n=30) were divided into two experimental groups (15 each) receiving only water (Control) or 36% alcohol solution oral administration. Thirty days later, all animals were submitted to titanium implant (2.2 mm x 4 mm) placement in the right and left tibiae. The surgical alveoli were prepared with a 2 mm drill mounted in a counter-angle hand-piece (20:1 ratio, 35 Ncm torque at 1200 rpm) under abundant cooling. Five animals from each group were euthanized at 15, 30, and 60 days. Tibiae were submitted to reverse torque analysis. Data obtained were submitted to statistical analysis by the non-parametric Kruskal-Wallis and Dunn Tests (p < 0.05). Animals in the alcohol group presented lower removal torque values when compared with control group animals for all periods tested (p < 0.05). It can be concluded that abusive alcohol consumption can reduce the removal torque of titanium implants placed in rat tibiae, suggesting that alcohol may interfere in the osseointegration process of titanium implants.
Resumo:
Studies have reported that alcohol may lead to imbalance in bone formation and resorption, however, its effects on osseointegration of titanium implants continues to be an inconclusive subject. In this context, the aim of this study was to make a biomechanical evaluation of the effect of abusive alcohol consumption on the removal torque of osseointegrated titanium implants. Male Wistar rats (n=30) were divided into two experimental groups (15 each) receiving only water (Control) or 36% alcohol solution oral administration. Thirty days later, all animals were submitted to titanium implant (2.2 mm x 4 mm) placement in the right and left tibiae. The surgical alveoli were prepared with a 2 mm drill mounted in a counter-angle hand-piece (20:1 ratio, 35 Ncm torque at 1200 rpm) under abundant cooling. Five animals from each group were euthanized at 15, 30, and 60 days. Tibiae were submitted to reverse torque analysis. Data obtained were submitted to statistical analysis by the non-parametric Kruskal-Wallis and Dunn Tests (p < 0.05). Animals in the alcohol group presented lower removal torque values when compared with control group animals for all periods tested (p < 0.05). It can be concluded that abusive alcohol consumption can reduce the removal torque of titanium implants placed in rat tibiae, suggesting that alcohol may interfere in the osseointegration process of titanium implants.
Resumo:
Um equino macho, raça Manga Larga, de 20 dias de idade, pesando 55 kg foi atendido no Hospital Veterinário “Luiz Quintiliano de Oliveira” com histórico de queda no dia anterior, apresentando impotência funcional e desvio do eixo ósseo do membro pélvico esquerdo (MPE). Ao exame radiográfico, constatou-se uma fratura classificada como Salter- Harris tipo II, na região distal da tíbia esquerda, com indicação para osteossíntese. Ao exame físico geral, observou-se frequência cardíaca (FC) de 82 batimentos.min-1, frequência respiratória (f) de 60 movimentos.min-1, mucosas róseas, tempo de preenchimento capilar de dois segundos, temperatura retal (ToC) de 38,5oC e hidratação adequada. Como medicação pré-anestésica, administrou-se xilazina (0,5 mg.kg-1) IV. A indução foi realizada por meio da administração de midazolam (0,1mg.kg-1) e cetamina (2mg.kg-1) IV. Seguiu-se a intubação orotraqueal com sonda n o 12 conectando-se a um circuito anestésico com reinalação parcial de gases, e a manutenção foi realizada com isofluorano em fluxo diluente de oxigênio a 100%, sob ventilação espontânea. Realizou-se a técnica de anestesia peridural com o paciente em decúbito lateral direito, introduzindo uma agulha 30x8 percutaneamente até atingir o espaço peridural entre as vértebras L6 e S1, onde se administrou lidocaína a 2% (2,2mg.kg-1) com vasoconstritor, perfazendo um volume de 6 mLs. Adicionalmente foi realizado o bloqueio perineural dos nervos tibial e fibular do membro acometido, com administração de 5 mLs de lidocaína a 2% com vasoconstritor em cada ponto. A administração de anestésicos locais pela via peridural na região L6 – S1 não é rotineiramente usada em equinos, uma vez que provoca ataxia ou perda do tônus muscular, aumentando os riscos relacionados à intervenção anestésica. No entanto, a recuperação do potro nesse relato de caso foi rápida e isenta de complicações, provalvelmente proporcionando anestesia multimodal e consequentemente menor depressão cardiovascular. A associação da anestesia peridural e bloqueio dos nervos tibial e fibular à anestesia geral, pode ser uma alternativa para intervenções cirúrgicas em membros pélvicos de potros, uma vez que demonstrou ser efetiva e de fácil execução.