948 resultados para Speckle tracking liver motion correction contrast-enhanced ultrasound
Resumo:
PURPOSE: To compare volume-targeted and whole-heart coronary magnetic resonance angiography (MRA) after the administration of an intravascular contrast agent. MATERIALS AND METHODS: Six healthy adult subjects underwent a navigator-gated and -corrected (NAV) free breathing volume-targeted cardiac-triggered inversion recovery (IR) 3D steady-state free precession (SSFP) coronary MRA sequence (t-CMRA) (spatial resolution = 1 x 1 x 3 mm(3)) and high spatial resolution IR 3D SSFP whole-heart coronary MRA (WH-CMRA) (spatial resolution = 1 x 1 x 2 mm(3)) after the administration of an intravascular contrast agent B-22956. Subjective and objective image quality parameters including maximal visible vessel length, vessel sharpness, and visibility of coronary side branches were evaluated for both t-CMRA and WH-CMRA. RESULTS: No significant differences (P = NS) in image quality were observed between contrast-enhanced t-CMRA and WH-CMRA. However, using an intravascular contrast agent, significantly longer vessel segments were measured on WH-CMRA vs. t-CMRA (right coronary artery [RCA] 13.5 +/- 0.7 cm vs. 12.5 +/- 0.2 cm; P < 0.05; and left circumflex coronary artery [LCX] 11.9 +/- 2.2 cm vs. 6.9 +/- 2.4 cm; P < 0.05). Significantly more side branches (13.3 +/- 1.2 vs. 8.7 +/- 1.2; P < 0.05) were visible for the left anterior descending coronary artery (LAD) on WH-CMRA vs. t-CMRA. Scanning time and navigator efficiency were similar for both techniques (t-CMRA: 6.05 min; 49% vs. WH-CMRA: 5.51 min; 54%, both P = NS). CONCLUSION: Both WH-CMRA and t-CMRA using SSFP are useful techniques for coronary MRA after the injection of an intravascular blood-pool agent. However, the vessel conspicuity for high spatial resolution WH-CMRA is not inferior to t-CMRA, while visible vessel length and the number of visible smaller-diameter vessels and side-branches are improved.
Resumo:
PURPOSE: To examine the impact of spatial resolution and respiratory motion on the ability to accurately measure atherosclerotic plaque burden and to visually identify atherosclerotic plaque composition. MATERIALS AND METHODS: Numerical simulations of the Bloch equations and vessel wall phantom studies were performed for different spatial resolutions by incrementally increasing the field of view. In addition, respiratory motion was simulated based on a measured physiologic breathing pattern. RESULTS: While a spatial resolution of > or = 6 pixels across the wall does not result in significant errors, a resolution of < or = 4 pixels across the wall leads to an overestimation of > 20%. Using a double-inversion T2-weighted turbo spin echo sequence, a resolution of 1 pixel across equally thick tissue layers (fibrous cap, lipid, smooth muscle) and a respiratory motion correction precision (gating window) of three times the thickness of the tissue layer allow for characterization of the different coronary wall components. CONCLUSIONS: We found that measurements in low-resolution black blood images tend to overestimate vessel wall area and underestimate lumen area.
Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction.
Resumo:
Respiratory motion is a major source of artifacts in cardiac magnetic resonance imaging (MRI). Free-breathing techniques with pencil-beam navigators efficiently suppress respiratory motion and minimize the need for patient cooperation. However, the correlation between the measured navigator position and the actual position of the heart may be adversely affected by hysteretic effects, navigator position, and temporal delays between the navigators and the image acquisition. In addition, irregular breathing patterns during navigator-gated scanning may result in low scan efficiency and prolonged scan time. The purpose of this study was to develop and implement a self-navigated, free-breathing, whole-heart 3D coronary MRI technique that would overcome these shortcomings and improve the ease-of-use of coronary MRI. A signal synchronous with respiration was extracted directly from the echoes acquired for imaging, and the motion information was used for retrospective, rigid-body, through-plane motion correction. The images obtained from the self-navigated reconstruction were compared with the results from conventional, prospective, pencil-beam navigator tracking. Image quality was improved in phantom studies using self-navigation, while equivalent results were obtained with both techniques in preliminary in vivo studies.
Resumo:
BACKGROUND: There is currently no consensus in the literature on which embolic agent induces the greatest degree of liver hypertrophy after portal vein embolization (PVE). Only experimental results in a pig model have demonstrated an advantage of n-butyl-cyanoacrylate (NBCA) over 3 other embolic materials (hydrophilic gel, small and large polyvinyl alcohol particles) for PVE. Therefore, the aim of this human study was to retrospectively compare the results of PVE using NBCA with those using spherical microparticles plus coils. METHODS: A total of 34 patients underwent PVE using either NBCA (n = 20), or spherical microparticles plus coils (n = 14). PVE was decided according to preoperative volumetry on the basis of contrast-enhanced CT. Groups were compared for age, sex, volume of the left lobe before PVE and future remnant liver ratio (FRL) (volume of the left lobe/total liver volume - tumor volume). The primary end point was the increase in left lobe volume 1 month after PVE. Secondary end points were procedure complications and biological tolerance. RESULTS: Both groups were similar in terms of age, sex ratio, left lobe volume, and FRL before PVE. NBCA induced a greater increase in volume after PVE than did microparticles plus coils (respectively, +74 ± 69 % and +23 ± 14 %, p < 0.05). The amount of contrast medium used for the procedure was significantly larger when microparticles and coils rather than NBCA were used (respectively, 264 ± 43 ml and 162 ± 34 ml, p < 0.01). The rate of PVE complications as well as the biological tolerance was similar in both groups. CONCLUSION: NBCA seems more effective than spherical microparticles plus coils to induce left-lobe hypertrophy.
Resumo:
Atherosclerosis is a chronic and progressive disease of the vasculature. Increasing coronary atherosclerosis can lead to obstructive coronary artery disease (CAD) or myocardial infarction. Computed tomography angiography (CTA) allows noninvasive assessment of coronary anatomy and quantitation of atherosclerotic burden. Myocardial blood flow (MBF) can be accurately measured in absolute terms (mL/g/min) by positron emission tomography (PET) with [15O] H O as a radiotracer. We studied the coronary microvascular dysfunction as a risk factor for future coronary calcification in healthy young men by measuring the coronary flow reserve (CFR) which is the ratio between resting and hyperemic MBF. Impaired vasodilator function was not linked with accelerated atherosclerosis 11 years later. Currently, there is a global interest in quantitative PET perfusion imaging. We established optimal thresholds of [15O] H O PET perfusion for diagnosis of CAD (hyperemic MBF of 2.3 mL/g/min and CFR of 2.5) in the first multicenter study of this type (Turku, Amsterdam and Uppsala). In myocardial bridging a segment of the coronary artery travels inside the myocardium and can be seen as intramural course (CTA) or systolic compression (invasive coronary angiography). Myocardial bridging is frequently linked with proximal atherosclerotic plaques. We used quantitative [15O] H O PET perfusion to evaluate the hemodynamic effects of myocardial bridging. Myocardial bridging was not associated with decreased absolute MBF or increased atherosclerotic burden. Speckle tracking allows quantitative echocardiographic imaging of myocardial deformation. Speckle tracking during dobutamine stress echocardiography was feasible and comparable to subjective wall motion analysis in the diagnosis of CAD. In addition, it correctly risk stratified patients with multivessel disease and extensive ischemia.
Resumo:
BACKGROUND/AIMS: It has been proposed that, in acute liver failure, skeletal muscle adapts to become the principle organ responsible for removal of blood-borne ammonia by increasing glutamine synthesis, a reaction that is catalyzed by the cytosolic ATP-dependent enzyme glutamine synthetase. To address this issue, glutamine synthetase expression and activities were measured in skeletal muscle of rats with acute liver failure resulting from hepatic devascularization. METHODS: Glutamine synthetase protein and gene expression were investigated using immunoblotting and semi-quantitative RT-PCR analysis. Glutamine synthetase activity and glutamine de novo synthesis were measured using, respectively, a standard enzymatic assay and [13C]-nuclear magnetic resonance spectroscopy. RESULTS: Glutamine synthetase protein (but not gene) expression and enzyme activities were significantly up-regulated leading to increased de novo synthesis of glutamine and increased skeletal muscle capacity for ammonia removal in acute liver failure. In contrast to skeletal muscle, expression and activities of glutamine synthetase in the brain were significantly decreased. CONCLUSIONS: These findings demonstrate that skeletal muscle adapts, through a rapid induction of glutamine synthetase, to increase its capacity for removal of blood-borne ammonia in acute liver failure. Maintenance of muscle mass together with the development of agents with the capacity to stimulate muscle glutamine synthetase could provide effective ammonia-lowering strategies in this disorder.
Resumo:
Introducción: La evaluación de la función miocárdica global y regional juega una papel crítico en el diagnóstico y manejo de los pacientes con enfermedad coronaria con importantes implicaciones pronosticas, las nuevas técnicas ecocardiográficas como la evaluación del STRAIN han sido validadas como una herramienta objetiva, comprehensiva y precisa para evaluar dichos parámetros. Objetivo: Determinar la capacidad del strain global longitudinal para la detección de estenosis coronaria significativa, número de territorios comprometidos y territorio anatómico del vaso culpable; en pacientes sin antecedentes de enfermedad coronaria previa con infarto agudo del miocardio. Diseño: estudio de pruebas diagnósticas retrospectivo en el que se utilizó como gold estándar la angiografía coronaria, se seleccionaron 64 pacientes con ecocardiograma transtorácico previo a la angiografía coronaria. Resultados: Se demostró una exactitud intermedia del strain global longitudinal para detectar estenosis coronaria por análisis de curvas ROC, con un área bajo la curva de 0,78 p= 0,000 (IC 0,6; 1,0), Una sensibilidad de 96.5% (91.7%, 101.3%), especificidad 40.0% (9.6%, 70.4%) y una prevalencia real del enfermedad coronaria de 85.1% (76.5%, 93.6%) Conclusiones: La medición de la función global y regional por medio del strain global longitudinal identifica pacientes con infarto agudo del miocardio que tienen estenosis coronaria significativa, número de territorios afectados, y la distribución anatómica de los posibles vasos culpables, sin embargo hay que tener precaución en su uso que sólo se limite a escenarios en donde pueda ser interpretado adecuadamente. Palabras clave: strain global bidimensional, detección de estenosis coronaria significativa, infarto del miocardio.
Resumo:
RESUMEN Introducción El papel de las nuevas técnicas ecocardiográficas para el diagnóstico de infarto agudo del miocardio se encuentra en desarrollo y la realización de mecánica ventricular izquierda podría sugerir la presencia de enfermedad coronaria hemodinámicamente significativa. Objetivos Determinar si en pacientes con infarto agudo del miocardio la medición de strain longitudinal global y regional sirve para predecir la presencia de enfermedad coronaria significativa. Métodos Es un estudio de pruebas diagnósticas en el que se evaluaron las características operativas de la mecánica ventricular izquierda para la detección de enfermedad coronaria significativa comparado contra el cateterismo cardiaco, considerado el patrón de oro. Se analizaron 54 pacientes con infarto agudo del miocardio llevados a cateterismo cardiaco, a quienes se les realizó un ecocardiograma transtorácico con medición de strain longitudinal global y regional. Resultados De los 54 pacientes analizados, el 83% tenía enfermedad coronaria significativa. El hallazgo de un strain longitudinal global < -17.5 tuvo una sensibilidad del 85% y una especificidad del 78% para predecir la presencia de enfermedad coronaria; para la arteria descendente anterior un strain longitudinal regional < – 17.4 tuvo una sensibilidad de 82% y una especificidad de 44%, para la arteria circunfleja una sensibilidad del 87% y una especificidad del 37% y para la arteria coronaria derecha una sensibilidad de 73% y una especificidad de 32%. Conclusiones La realización de ecocardiografía con mecánica ventricular en pacientes con infarto agudo del miocardio es útil para predecir la presencia de enfermedad coronaria hemodinámicamente significativa.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Pós-graduação em Medicina Veterinária - FCAV
Resumo:
Pós-graduação em Fisiopatologia em Clínica Médica - FMB
Resumo:
Pós-graduação em Fisiopatologia em Clínica Médica - FMB
Resumo:
Objectives: To integrate data from two-dimensional echocardiography (2D ECHO), three-dimensional echocardiography (3D ECHO), and tissue Doppler imaging (TDI) for prediction of left ventricular (LV) reverse remodeling (LVRR) after cardiac resynchronization therapy (CRT). It was also compared the evaluation of cardiac dyssynchrony by TDI and 3D ECHO. Methods: Twenty-four consecutive patients with heart failure, sinus rhythm, QRS = 120 msec, functional class III or IV and LV ejection fraction (LVEF) = 0.35 underwent CRT. 2D ECHO, 3D ECHO with systolic dyssynchrony index (SDI) analysis, and TDI were performed before, 3 and 6 months after CRT. Cardiac dyssynchrony analyses by TDI and SDI were compared with the Pearson's correlation test. Before CRT, a univariate analysis of baseline characteristics was performed for the construction of a logistic regression model to identify the best predictors of LVRR. Results: After 3 months of CRT, there was a moderate correlation between TDI and SDI (r = 0.52). At other time points, there was no strong correlation. Nine of twenty-four (38%) patients presented with LVRR 6 months after CRT. After logistic regression analysis, SDI (SDI > 11%) was the only independent factor in the prediction of LVRR 6 months of CRT (sensitivity = 0.89 and specificity = 0.73). After construction of receiver operator characteristic (ROC) curves, an equation was established to predict LVRR: LVRR =-0.4LVDD (mm) + 0.5LVEF (%) + 1.1SDI (%), with responders presenting values >0 (sensitivity = 0.67 and specificity = 0.87). Conclusions: In this study, there was no strong correlation between TDI and SDI. An equation is proposed for the prediction of LVRR after CRT. Although larger trials are needed to validate these findings, this equation may be useful to candidates for CRT. (Echocardiography 2012;29:678-687)
Resumo:
Background New potential hazards in the use of ultrasound (US) are implied in new diagnostic applications of US, such as contrast enhanced US. Aim To assess the level of awareness and knowledge on safety issues of clinical use of US among physicians who are members of the Italian National Society for Ultrasound (SIUMB) Materials and methods A questionnaire including 11 multiple choice quiz was sent by e-mail to members of SIUMB, who preliminarly agreed to participate in this initiative. The answers were received anonimously and statistically analyzed. Results The number of returned valid questionnaires was 97 (8 were considered not valid for less than 10 answers filled). Mean age of the responders was 44 years old, and the average time the physician has been performing ultrasound examinations was 13 years. The principal workplace (70%) was a public Hospital. Physicians seemed to know the general definitions of principal safety-parameters, but few of them knew the definition of specific indexes. There was a general knowledge about the safe use of ultrasound in obstetrics, but there was a poor knowledge of biological effects of US: only about 37% answered correctly to questions about damage of vasculature of lung by high Mechanical Index US investigation and about the increase of temperature under the probe, according to the thermal indexes. Conclusion In conclusion the present findings indicate that greater efforts of National Ultrasound Societies are warranted in disseminating knowledge about the bio-effects of diagnostic ultrasound modalities among their members to prevent possible hazards.