954 resultados para Shoulder injuries


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Given the important role of the shoulder sensorimotor system in shoulder stability, its assessment appears of interest. Force platform monitoring of centre of pressure (CoP) in upper-limb weight-bearing positions is of interest as it allows integration of all aspects of shoulder sensorimotor control. This study aimed to determine the feasibility and reliability of shoulder sensorimotor control assessment by force platform. Forty-five healthy subjects performed two sessions of CoP measurement using Win-Posturo(®) Medicapteurs force platform in an upper-limb weight-bearing position with the lower limbs resting on a table to either the anterior superior iliac spines (P1) or upper patellar poles (P2). Four different conditions were tested in each position in random order: eyes open or eyes closed with trunk supported by both hands and eyes open with trunk supported on the dominant or non-dominant side. P1 reliability values were globally moderate to high for CoP length, CoP velocity and CoP standard deviation (SD), standard error of measurement ranged from 6·0% to 26·5%, except for CoP area. P2 reliability values were globally low and not clinically acceptable. Our results suggest that shoulder sensorimotor control assessment by force platform is feasible and has good reliability in upper-limb weight-bearing positions when the lower limbs are resting on a table to the anterior superior iliac spines. CoP length, CoP velocity and CoP SD velocity appear to be the most reliable variables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Under Iowa law, hospitals treating persons with a brain or spinal cord injury which results in a hospital admission, patient transfer, or death must report that injury to the Central Registry for Brain and Spinal Cord Injuries of the Iowa Department of Public Health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Several studies have reported significant alteration of the scapula-humeral rythm after total shoulder arthroplasty. However, the biomechanical and clinical effects, particularly on implants lifespan, are still unknown. The goal of this study was to evaluate the biomechanical consequences of an altered scapula-humeral rhythm. Methods: A numerical musculoskeletal model of the shoulder was used. The model included the scapula, the humerus and 6 scapulohumeral muscles: middle, anterior, and posterior deltoid, supraspinatus, subscapularis and infraspinatus combined with teres minor. Arm motion and joint stability were achieved by muscles. The reverse and anatomic Aequalis prostheses (Tornier Inc) were inserted. Two scapula-humeral rhythms were considered for each prosthesis: a normal 2:1 rhythm, and an altered 1:2 rhythm. For the 4 configurations, a movement of abduction in the scapular plane was simulated. The gleno-humeral force and contact pattern, but also the stress in the polyethylene and cement were evaluated. Results: With the anatomical prosthesis, the gleno-humeral force increased of 23% for the altered rhythm, with a more eccentric (posterior and superior) contact. The contact pressure, polyethylene stress, and cement stress increased respectively by 20%, 48% and 64%. With the reverse prosthesis, the gleno-humeral force increased of 11% for an altered rhythm. There was nearly no effect on the contact pattern on the polyethylene component surface. Conclusion: The present study showed that alteration oft the scapula-humeral rythm induced biomechanical consequences which could preclude the long term survival of the glenoid implant of anatomic prostheses. However,an altered scapula-humeral rhythm, even severe, should not be a contra indication for the use of a reverse prosthesis. 

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To describe osseous, chondral and tendinous lesions associated with fissures of the posterior labrum. To better understand the pathological processes leading to fissure of the posterior labrum. Materials and methods. Retrospective study of 43 CT arthrograms performed in 43 patients that showed a fissure of the posterior labrum. The following associated lesions were noted: osseous and chondral remodeling of the humeral head and/or glenoid and articular surface fissures of the rotator cuff. Based on type of associated lesions, patients were separated into one of four pathological subgroups: posterior instability, posterosuperior or internal impingement, anterior instability and isolated fissure of the posterior labrum. RESULTS: Sixteen patients (37.2%) of patients showed posterior instability, 12 (27.9%) showed lesions of internal impingement, and 11 (25.6%) showed lesions of anterior instability. Only 4 patients (9.3%) had an isolated fissure of the posterior labrum. CONCLUSION: Posterior instability, internal impingement and anterior instability are the main pathologies leading to fissure of the posterior labrum, which seldom occurs in isolation. Evaluation of these associated lesions allows understanding of the underlying pathological processes leading to fissure of the posterior labrum.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The value of providing paved shoulders adjacent to many higher volume roadways has been accepted in many states across the country. Iowa’s paved shoulder policy is considerably more conservative than neighboring states, particularly on rural four-lane and high-volume two-lane highways. The objectives of this research are to examine current design criteria for shoulders employed in Iowa and surrounding states, compare benefits and costs of alternative surface types and widths, and make recommendations based on this analysis for consideration in future design policies for primary highway in Iowa. The report finds that many safety and maintenance benefits would result from enhancing Iowa’s paved shoulder and rumble strip design practices for freeways, expressways, and Super 2 highway corridors. The benefits of paved shoulders include reduced numbers of certain crashes, higher capacity potentials, reduced maintenance, enhanced opportunities for other users such as bicyclists, and even possible increased longevity of pavements. Alternative paved shoulder policies and programming strategies are also offered, with detailed assessments of the benefits, costs, and budget impacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blunt chest traumas are a clinical challenge, both for diagnosis and treatment. The use ofCardiovascular Magnetic Resonance can play a major role in this setting. We present two cases: a12-year-old boy and 45-year-old man. Late gadolinium enhancement imaging enabled visualizationof myocardial damage resulting from the trauma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Reversed shoulder arthroplasty is an accepted treatment for glenohumeral arthritis associated to rotator cuff deficiency. For most reversed shoulder prostheses, the baseplate of the glenoid component is uncemented and its primary stability is provided by a central peg and peripheral screws. Because of the importance of the primary stability for a good osteo-integration of the baseplate, the optimal fixation of the screws is crucial. In particular, the amplitude of the tightening force of the nonlocking screws is clearly associated to this stability. Since this force is unknown, it is currently not accounted for in experimental or numerical analyses. Thus, the primary goal of this work is to measure this tightening force experimentally. In addition, the tightening torque was also measured, to estimate an optimal surgical value. METHODS: An experimental setup with an instrumented baseplate was developed to measure simultaneously the tightening force, tightening torque and screwing angle, of the nonlocking screws of the Aquealis reversed prosthesis. In addition, the amount of bone volume around each screw was measured with a micro-CT. Measurements were performed on 6 human cadaveric scapulae. FINDINGS: A statistically correlated relationship (p<0.05, R=0.83) was obtained between the maximal tightening force and the bone volume. The relationship between the tightening torque and the bone volume was not statistically significant. INTERPRETATION: The experimental relationship presented in this paper can be used in numerical analyses to improve the baseplate fixation in the glenoid bone.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Non-operative management (NOM) of blunt splenic injuries (BSI) is nowadays considered the standard treatment. The study aimed to determine the criteria applied for NOM and to identify risk factors for its failure. Methods: Review of all adult patients with BSI treated at the University Hospital Bern, Switzerland, between 2000 and 2008. Results: There were 206 patients (146 men, 70·9%) with a mean age of 38·2 ± 19·1 years and an Injury Severity Score of 30·9 ± 11·6. The American Association for the Surgery of Trauma classification of the splenic injury was: grade I, n=43 (20·9%); grade II, n=52 (25·2%); grade III, n=60 (29·1%); grade IV, n=42 (20·4%) and grade V, n=9 (4·4%). 47 patients (22·8%) required immediate surgery. Five or more units of red cell transfusions (P<0·001), Glasgow Coma Scale<11 (P=0·009) and age ≥55 years (P=0·038) were associated with primary operative management (OM). 159 patients (77·2%) qualified for NOM, which was successful in 89·9% (143/159). The overall splenic salvage rate was 69·4% (143/206). Multivariate analysis found age ≥40 years to be the only factor independently related to the failure of NOM (P=0·001). Conclusion: Advanced age is associated with an increased failure rate ofNOM in patients with BSI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Glenoid bone volume and bone quality can render the fixation of a reversed shoulder arthroplasty (RSA) basis plate hazardous. Cadaveric study at our institution has demonstrated that optimal baseplate fixation could be achieved with screws in three major columns. Our aim is to review our early rate of aseptic glenoid loosening in a series of baseplates fixed according to this principle. Methods: Between 2005 and 2008, 48 consecutive RSA (Reversed Aequalis) were implanted in 48 patients with an average age of 74.4 years (range, 56 to 86 years). There were 37 women and 11 men. Twenty-seven primary RSAs were performed for cuff tear arthropathy, 3 after failed rotator cuff surgery, 6 for failed arthroplasties, 7 for acute fractures and 5 after failed ORIF. All baseplate fixations were done using a nonlocking posterior screw in the scapular spine, a nonlocking anterior screw in the glenoid body, a locking superior screw in the coracoid and a locking inferior screw in the pillar. All patients were reviewed with standardized radiographs. We reported the positions of the screws in relation to the scapular spine and the coracoid process in two different views. We defined screw positions as totally, partially or out of the target. Finally, we reported aseptic glenoid loosening which was defined as implant subsidence. Results: Four patients were lost to follow-up. Thus 44 shoulders could be reviewed after a mean follow-up of 16 months (range, 9 to 32 months). Thirty-seven (84%) screws were either partially or totally in the spine. Thus, 7 (16%) scapular spine screws were out of the target. No coracoid screw was out of the target. At final follow-up control, we reported no glenoid loosening. Conclusion: Early glenoid loosening occurred before the two years follow-up and is most of time related to technical problems and/or insufficient glenoid bone stock and bone quality. Our study demonstrate that baseplate fixation of a RSA according to the three columns principle is a reproducible technique and a valuable way to prevent early glenoid loosening.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Complex foot and ankle fractures, such as calcaneum fractures or Lisfranc dislocations, are often associated with a poor outcome, especially in terms of gait capacity. Indeed, degenerative changes often lead to chronic pain and chronic functional limitations. Prescription footwear represents an important therapeutic tool during the rehabilitation process. Local Dynamic Stability (LDS) is the ability of locomotor system to maintain continuous walking by accommodating small perturbations that occur naturally during walking. Because it reflects the degree of control over the gait, LDS has been advocated as a relevant indicator for evaluating different conditions and pathologies. The aim of this study was to analyze changes in LDS induced by orthopaedic shoes in patients with persistent foot and ankle injuries. We hypothesised that footwear adaptation might help patients to improve gait control, which could lead to higher LDS: METHODS: Twenty-five middle-aged inpatients (5 females, 20 males) participated in the study. They were treated for chronic post-traumatic disabilities following ankle and/or foot fractures in a Swiss rehabilitation clinic. During their stay, included inpatients received orthopaedic shoes with custom-made orthoses (insoles). They performed two 30s walking trials with standard shoes and two 30s trials with orthopaedic shoes. A triaxial motion sensor recorded 3D accelerations at the lower back level. LDS was assessed by computing divergence exponents in the acceleration signals (maximal Lyapunov exponents). Pain was evaluated with Visual Analogue Scale (VAS). LDS and pain differences between the trials with standard shoes and the trials with orthopaedic shoes were assessed. RESULTS: Orthopaedic shoes significantly improved LDS in the three axes (medio-lateral: 10% relative change, paired t-test p < 0.001; vertical: 9%, p = 0.03; antero-posterior: 7%, p = 0.04). A significant decrease in pain level (VAS score -29%) was observed. CONCLUSIONS: Footwear adaptation led to pain relief and to improved foot & ankle proprioception. It is likely that that enhancement allows patients to better control foot placement. As a result, higher dynamic stability has been observed. LDS seems therefore a valuable index that could be used in early evaluation of footwear outcome in clinical settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Anatomical total shoulder arthroplasty (TSA) for glenohumeral osteoarthritis (OA) and severe posterior glenoid wear may entail early postoperative complications (recurrence of posterior subluxation, glenoid loosening). To avoid these mechanical problems, reverse shoulder arthroplasty (RSA) has recently been proposed, mainly for its intrinsic stability. Our purpose was to present the results of TSA and RSA in glenohumeral OA with posterior glenoid wear of at least 20°. HYPOTHESIS: By virtue of its constrained design, RSA could prevent recurrence of posterior subluxation and limit the occurrence of mechanical complications. MATERIALS AND METHODS: A consecutive series of 23 patients (27 shoulders) were treated for glenohumeral OA with total shoulder prostheses: 19 TSAs and 8 RSAs. Mean age was 70years (range, 47-85years), mean retroversion angle 28° (20°-50°) and mean subluxation index 74% (57-89%). Constant Score, Subjective Shoulder Value (SSV), QuickDASH and Simple Shoulder Test (SST) were measured, and radiological examinations were performed at a mean follow-up of 52months (24-95months). RESULTS: TSA and RSA patients respectively displayed Constant Scores of 65 and 65, SSV of 79% and 74%, QuickDASH of 16 and 27, and SST of 88 and 78. Two patients underwent surgical revision of TSA because of glenoid loosening; 52% of TSA patients presented complete radiolucent lines and 11% recurrence of posterior subluxation. CONCLUSION: Complications are frequently observed after shoulder arthroplasty for OA with severe glenoid retroversion. RSA could be an alternative to TSA for selected patients, independently of rotator cuff status. Studies on RSA in this specific indication with longer follow-up are now needed. LEVEL OF EVIDENCE: Level IV; retrospective case series.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed at analyzing nipple trauma resulted from breastfeeding based on dermatological approach. Two integrative reviews of literature were conducted, the first related to definitions, classification and evaluation methods of nipple trauma and another about validation studies related to this theme. In the first part were included 20 studies and only one third defined nipple trauma, more than half did not defined the nipple’s injuries reported, and each author showed a particular way to assess the injuries, without consensus. In the second integrative review, no validation study or algorithm related to nipple trauma resulted from breastfeeding was found. This fact demonstrated that the nipple’s injuries mentioned in the first review did not go through validation studies, justifying the lack of consensus identified as far as definition, classification and assessment methods of nipple trauma.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2003, the INTERMED, an instrument to assess biopsycho- social case complexity and to direct care, was introduced in daily clinical practice in the .Clinique romande de réadaptation suvaCare., a national rehabilitation hospital for traumatic injuries, located in the French speaking part of Switzerland. The introduction of the INTERMED was easy to realize and no major obstacles hampered its systematic implementation. Up to now, about 2,000 patients have been evaluated with the INTERMED and are followed for different outcomes. The INTERMED improved not only patients. assessment by including relevant psychosocial aspects of the clinical situation, it also favoured interdisciplinary communication, enhanced work satisfaction of the nursing staff and allowed early identification and adaptation of treatment for the injured patient showing a high degree of case complexity. Upon follow up, patients with a high degree of case-complexity showed a less favourable outcome, i.e. more health care utilization and lower rates of return to work. In conclusion, the systematic implementation of the INTERMED enabled the reorganization of medical rehabilitation, anchored it in a bio-psycho-social framework, improving interdisciplinary communication and collaboration and ameliorated treatment outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Granular shoulders are an important element of the transportation system and are constantly subjected to performance problems due to wind- and water-induced erosion, rutting, edge drop-off, and slope irregularities. Such problems can directly affect drivers’ safety and often require regular maintenance. The present research study was undertaken to investigate the factors contributing to these performance problems and to propose new ideas to design and maintain granular shoulders while keeping ownership costs low. This report includes observations made during a field reconnaissance study, findings from an effort to stabilize the granular and subgrade layer at six shoulder test sections, and the results of a laboratory box study where a shoulder section overlying a soft foundation layer was simulated. Based on the research described in this report, the following changes are proposed to the construction and maintenance methods for granular shoulders: • A minimum CBR value for the granular and subgrade layer should be selected to alleviate edge drop-off and rutting formation. • For those constructing new shoulder sections, the design charts provided in this report can be used as a rapid guide based on an allowable rut depth. The charts can also be used to predict the behavior of existing shoulders. • In the case of existing shoulder sections overlying soft foundations, the use of geogrid or fly ash stabilization proved to be an effective technique for mitigating shoulder rutting.