998 resultados para Scale mitigation
Resumo:
Introduction: Parkinson`s disease (PD) is a neurodegenerative disorder with prominent motor manifestations and many other non-motor symptoms that significantly decrease quality-of-life and are frequently under-recognized, for example depression. Objective: To study the validity of a Brazilian version of the Zung Self-rating Depression Scale (SDS) for the diagnosis of depression in patients with PD. Methods: We evaluated 78 consecutive non demented patients over the age of 40 with diagnosis of PD at a Movement Disorders Outpatient Clinic, who could read and understand questionnaires. They completed the SIDS and the Geriatric Depression Scale with 15 items (GDS-15). The diagnosis of depression was made after a structured clinical interview based on DSM-IV criteria for the diagnosis of major depression (SCID-CV). Results: The prevalence of major depression was 23.1%. Cronbach`s alpha was 0.73 and the area under the ROC curve was 0.93 for the SDS. The score index of 55 had a sensitivity of 88.9% and a specificity of 83.3% for the diagnosis of depression. The total scores of the SDS and GDS-15 were highly correlated (0.652, p < 0.0001) and correlated weakly with the scores of a motor scale. Discussion: The SIDS is a valid too] for screening depression in patients with PD since the specific SDS index of 55 is adopted. Two shortened versions could be used with good results. (C) 2009 Published by Elsevier Ltd.
Resumo:
Background: We aimed to validate three widely used scales in stroke research in a multiethnic Brazilian population. Methods: The National Institutes of Health Stroke Scale (NIHSS), modified Rankin Scale (mRS) and Barthel Index (BI) were translated, culturally adapted and applied by two independent investigators. The mRS was applied with or without a previously validated structured interview. Interobserver agreement (kappa statistics) and intraclass correlation coefficients were calculated. Results: 84 patients underwent mRS (56 with and 28 without a structured interview), 57 BI and 62 NIHSS scoring. Intraclass correlation coefficient was 0.902 for NIHSS and 0.967 for BI. For BI, interobserver agreement was good (kappa = 0.70). For mRS, the structured interview improved interobserver agreement (kappa = 0.34 without a structured interview; 0.75 with a structured interview). Conclusion: The NIHSS, BI and mRS show good validity when translated and culturally adapted. Using a structured interview for the mRS improves interobserver concordance rates. Copyright (C) 2008 S. Karger AG, Basel
Resumo:
Quality of life (QOL) has been extensively studied in clinical trials and in research on chronic degenerative diseases and dementia. The aim of this study was to assess the reliability and construct validity of the Brazilian version of the QOL scale in Alzheimer`s disease (AD; QOL-AD). The QOL-AD was administered to 60 patients with mild or moderate AD and to their caregivers. The construct validation was accomplished through correlations amongst total scores of patients` and caregivers` reports on patients` quality of life (PQOL and C-PQOL, respectively), and data related to cognitive impairment, depressive symptoms, functional performance, behavioral disturbances and a generic instrument of quality of life (WHOQOL-brief), as well as correlation of total score of caregivers` reports on their own quality of life (CQOL) with the measurements cited above, QOL-AD patient reports, and depressive symptoms. The reliability was high for PQOL, C-PQOL, and CQOL versions (Cronbach`s alpha = 0.80, 0.83, and 0.86, respectively). We observed significant correlations in the construct validity of all three versions regarding the variables associated with the disease and also with WHOQOL-brief. The scale took, on average, six min for each version. The results indicate reliability and construct validity of the Brazilian version of the QOL-AD in the studied sample.
Resumo:
Objective To evaluate the inter-rater reliability of the modified Oxford Grading Scale and the Peritron manometer. Design All participants were evaluated twice, first by one examiner and 30 days later by a second examiner. Measurements of vaginal squeeze pressure were compared with the results from the palpation test. Participants Nineteen women with a mean age of 23.7 years (range 21 to 28 years). Results Inter-rater reliability for vaginal palpation was fair (kappa = 0.33, 95% confidence interval 0.09 to 0.57). Using the Peritron manometer, the difference between examiners was less than 10 cmH(2)O in 11 of the 19 (58%) cases. The palpation test did not differentiate between weak, moderate, good and strong muscle contractions. This study found fair inter-rater reliability for the modified Oxford Grading Scale and moderate inter-rater reliability for the Peritron manometer. Conclusions The inter-rater reliability of vaginal squeeze pressure measurement using the Peritron manometer is acceptable and can be used in re-evaluations performed by different examiners in clinical practice. However, for research purposes, the ideal situation would be for a single examiner to assess and re-assess the subject. Vaginal palpation is important in the clinical assessment of correctness of a pelvic floor muscle contraction, but this study does not support the use of the modified Oxford Grading Scale as a reliable and valid method to measure and differentiate pelvic floor muscle strength. (C) 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Resumo:
Non-periodic structural variation has been found in the high T-c cuprates, YBa2Cu3O7-x and Hg0.67Pb0.33Ba2Ca2Cu3O8+delta, by image analysis of high resolution transmission electron microscope (HRTEM) images. We use two methods for analysis of the HRTEM images. The first method is a means for measuring the bending of lattice fringes at twin planes. The second method is a low-pass filter technique which enhances information contained by diffuse-scattered electrons and reveals what appears to be an interference effect between domains of differing lattice parameter in the top and bottom of the thin foil. We believe that these methods of image analysis could be usefully applied to the many thousands of HRTEM images that have been collected by other workers in the high temperature superconductor field. This work provides direct structural evidence for phase separation in high T-c cuprates, and gives support to recent stripes models that have been proposed to explain various angle resolved photoelectron spectroscopy and nuclear magnetic resonance data. We believe that the structural variation is a response to an opening of an electronic solubility gap where holes are not uniformly distributed in the material but are confined to metallic stripes. Optimum doping may occur as a consequence of the diffuse boundaries between stripes which arise from spinodal decomposition. Theoretical ideas about the high T-c cuprates which treat the cuprates as homogeneous may need to be modified in order to take account of this type of structural variation.
Resumo:
We shall examine a model, first studied by Brockwell et al. [Adv Appl Probab 14 (1982) 709.], which can be used to describe the longterm behaviour of populations that are subject to catastrophic mortality or emigration events. Populations can suffer dramatic declines when disease, such as an introduced virus, affects the population, or when food shortages occur, due to overgrazing or fluctuations in rainfall. However, perhaps surprisingly, such populations can survive for long periods and, although they may eventually become extinct, they can exhibit an apparently stationary regime. It is useful to be able to model this behaviour. This is particularly true of the ecological examples that motivated the present study, since, in order to properly manage these populations, it is necessary to be able to predict persistence times and to estimate the conditional probability distribution of population size. We shall see that although our model predicts eventual extinction, the time till extinction can be long and the stationary exhibited by these populations over any reasonable time scale can be explained using a quasistationary distribution. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
Previous genetic analyses of psychosis proneness have been limited by their small sample size. For the purposes of large-scale screening, a 12-item questionnaire was developed through a two-stage process of reduction from the full Chapman and Chapman scales. 3685 individuals (including 1438 complete twin pairs) aged 18–25 years and enrolled in the volunteer Australian Twin Registry returned a mail questionnaire which included this psychosis proneness scale and the Eysenck Personality Questionnaire. Despite the brevity of the questionnaire, item and factor analysis identified four unambiguous and essentially uncorrelated scales. There were (1) Perceptual Aberration – Magical Ideation; (2) Hypomania – Impulsivity/Nonconformity; (3) Social Anhedonia and (4) Physical Anhedonia. Model-fitting analyses showed additive genetic and specific environmental factors were sufficient for three of the four scales, with the Social Anhedonia scale requiring also a parameter for genetic dominance. There was no evidence for the previously hypothesised sex differences in the genetic determination of psychosis-proneness. The potential value of multivariate genetic analysis to examine the relationship between these four scales and dimensions of personality is discussed. The growing body of longitudinal evidence on psychosis-proneness suggests the value of incorporating this brief measure into developmental twin studies.
Resumo:
Bond's method for ball mill scale-up only gives the mill power draw for a given duty. This method is incompatible with computer modelling and simulation techniques. It might not be applicable for the design of fine grinding ball mills and ball mills preceded by autogenous and semi-autogenous grinding mills. Model-based ball mill scale-up methods have not been validated using a wide range of full-scale circuit data. Their accuracy is therefore questionable. Some of these methods also need expensive pilot testing. A new ball mill scale-up procedure is developed which does not have these limitations. This procedure uses data from two laboratory tests to determine the parameters of a ball mill model. A set of scale-up criteria then scales-up these parameters. The procedure uses the scaled-up parameters to simulate the steady state performance of full-scale mill circuits. At the end of the simulation, the scale-up procedure gives the size distribution, the volumetric flowrate and the mass flowrate of all the streams in the circuit, and the mill power draw.
Resumo:
A new ball mill scale-up procedure is developed which uses laboratory data to predict the performance of MI-scale ball mill circuits. This procedure contains two laboratory tests. These laboratory tests give the data for the determination of the parameters of a ball mill model. A set of scale-up criteria then scales-up these parameters. The procedure uses the scaled-up parameters to simulate the steady state performance of the full-scale mill circuit. At the end of the simulation, the scale-up procedure gives the size distribution, the volumetric flowrate and the mass flowrate of all the streams in the circuit, and the mill power draw. A worked example shows how the new ball mill scale-up procedure is executed. This worked example uses laboratory data to predict the performance of a full-scale re-grind mill circuit. This circuit consists of a ball mill in closed circuit with hydrocyclones. The MI-scale ball mill has a diameter (inside liners) of 1.85m. The scale-up procedure shows that the full-scale circuit produces a product (hydrocyclone overflow) that has an 80% passing size of 80 mum. The circuit has a recirculating load of 173%. The calculated power draw of the full-scale mill is 92kW (C) 2001 Elsevier Science Ltd. All rights reserved.
Model-based procedure for scale-up of wet, overflow ball mills - Part III: Validation and discussion
Resumo:
A new ball mill scale-up procedure is developed. This procedure has been validated using seven sets of Ml-scale ball mil data. The largest ball mills in these data have diameters (inside liners) of 6.58m. The procedure can predict the 80% passing size of the circuit product to within +/-6% of the measured value, with a precision of +/-11% (one standard deviation); the re-circulating load to within +/-33% of the mass-balanced value (this error margin is within the uncertainty associated with the determination of the re-circulating load); and the mill power to within +/-5% of the measured value. This procedure is applicable for the design of ball mills which are preceded by autogenous (AG) mills, semi-autogenous (SAG) mills, crushers and flotation circuits. The new procedure is more precise and more accurate than Bond's method for ball mill scale-up. This procedure contains no efficiency correction which relates to the mill diameter. This suggests that, within the range of mill diameter studied, milling efficiency does not vary with mill diameter. This is in contrast with Bond's equation-Bond claimed that milling efficiency increases with mill diameter. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
The Australian Coal Industry Research Laboratory (ACIRL) furnace is scaled to simulate slagging and fouling in operating boilers. This requires that the gas and target temperatures, the heat flux, and the flow pattern be the same as those in real boilers. The gas and target temperatures are maintained by insulating the wall and cooling the target respectively. The flow pattern of a small burner cannot be the same as a large furnace. However, this flow pattern is partially compensated for by placing the slagging panels in three vertical locations. The paper develops the models of radiant heat transfer from the flame to the deposits both in pilot-scale and full-scale furnaces. They are used to compare the effective radiant heat transfer of the pilot- and full-scale furnaces. The experimental data both from the pilot- and full-scale furnaces are used to verify the incident heat flux and temperature profiles in the pilot- and full-scale furnaces. The results showed that the thermal condition in the pilot-scale furnace meets the requirements for studying the slagging regarding the gas temperature and the incident heat flux, particularly for the panel #1. The gas temperature in the convective section also meets the requirement for studying the fouling.