Provides the number of reported nonconsensual eavesdropping devices used during 1996, including reports forwarded to the director by participating state's attorneys, the number of law enforcement personnel involved in the seizure of intercepts, and the total cost to the department of all activities relating to the seizure of intercepts. Also provided are the number of department personnel authorized to possess, install or operate nonconsensual eavesdropping devices and the total number of law enforcement officers trained by the Illinois State Police, Technical Investigation Section, to participate in nonconsensual wiretaps.
Resumo:
Description based on: 1982.
Resumo:
Cover title.
Resumo:
Protein molecular motors, which are natural nano-machines that convert the chemical energy into mechanical work for cellular motion, muscle contraction and cell division, have been integrated in the last decade in primitive nanodevices based on the motility of nano-biological objects in micro- and nano-fabricated structures. However, the motility of microorganisms powered by molecular motors has not been similarly exploited. Moreover, among the proposed devices based on molecular motors, i.e., nanosensors, nano-mechanical devices and nano-imaging devices, biocomputation devices are conspicuously missing. The present contribution discusses, based on the present state of the art nano- and micro-fabrication, the comparative advantages and disadvantages of using nano- and micro-biological objects in future computation devices. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
We analyze the steady-state propagation of optical pulses in fiber transmission systems with lumped nonlinear optical devices (NODs) placed periodically in the line. For the first time to our knowledge, a theoretical model is developed to describe the transmission regime with a quasilinear pulse evolution along the transmission line and the point action of NODs. We formulate the mapping problem for pulse propagation in a unit cell of the line and show that in the particular application to nonlinear optical loop mirrors, the steady-state pulse characteristics predicted by the theory accurately reproduce the results of direct numerical simulations.
Resumo:
We analyze the steady-state propagation of optical pulses in fiber transmission systems with lumped nonlinear optical devices (NODs) placed periodically in the line. For the first time to our knowledge, a theoretical model is developed to describe the transmission regime with a quasilinear pulse evolution along the transmission line and the point action of NODs. We formulate the mapping problem for pulse propagation in a unit cell of the line and show that in the particular application to nonlinear optical loop mirrors, the steady-state pulse characteristics predicted by the theory accurately reproduce the results of direct numerical simulations. © 2005 Springer Science+Business Media, Inc.
Resumo:
We study InGaAs QD laser operating simultaneously at ground (GS) and excited (ES) states under 30ns pulsed-pumping and distinguish three regimes of operation depending on the pump current and the carrier relaxation pathways. An increased current leads to an increase in ES intensity and to a decrease in GS intensity (or saturation) for low pump range, as typical for the cascade-like pathway. Both the GS and ES intensities are steadily increased for high current ranges, which prove the dominance of the direct capture pathway. The relaxation oscillations are not pronounced for these ranges. For the mediate currents, the interplay between the both pathways leads to the damped large amplitude relaxation oscillations with significant deviation of the relaxation oscillation frequency from the initial value during the pulse.
Resumo:
Insulated gate bipolar transistor (IGBT) modules are important safety critical components in electrical power systems. Bond wire lift-off, a plastic deformation between wire bond and adjacent layers of a device caused by repeated power/thermal cycles, is the most common failure mechanism in IGBT modules. For the early detection and characterization of such failures, it is important to constantly detect or monitor the health state of IGBT modules, and the state of bond wires in particular. This paper introduces eddy current pulsed thermography (ECPT), a nondestructive evaluation technique, for the state detection and characterization of bond wire lift-off in IGBT modules. After the introduction of the experimental ECPT system, numerical simulation work is reported. The presented simulations are based on the 3-D electromagnetic-thermal coupling finite-element method and analyze transient temperature distribution within the bond wires. This paper illustrates the thermal patterns of bond wires using inductive heating with different wire statuses (lifted-off or well bonded) under two excitation conditions: nonuniform and uniform magnetic field excitations. Experimental results show that uniform excitation of healthy bonding wires, using a Helmholtz coil, provides the same eddy currents on each, while different eddy currents are seen on faulty wires. Both experimental and numerical results show that ECPT can be used for the detection and characterization of bond wires in power semiconductors through the analysis of the transient heating patterns of the wires. The main impact of this paper is that it is the first time electromagnetic induction thermography, so-called ECPT, has been employed on power/electronic devices. Because of its capability of contactless inspection of multiple wires in a single pass, and as such it opens a wide field of investigation in power/electronic devices for failure detection, performance characterization, and health monitoring.
Resumo:
Right across Europe technology is playing a vital part in enhancing learning for an increasingly diverse population of learners. Learning is increasingly flexible, social and mobile and supported by high quality multi-media resources. Institutional VLEs are seeing a shift towards open source products and these core systems are supplemented by a range of social and collaborative learning tools based on web 2.0 technologies. Learners undertaking field studies and those in the workplace are coming to expect that these off-campus experiences will also be technology-rich whether supported by institutional or user-owned devices. As well as keeping European businesses competitive, learning is seen as a means of increasing social mobility and supporting an agenda of social justice. For a number of years the EUNIS E-Learning Task Force (ELTF) has conducted snapshot surveys of e-learning across member institutions, collected case studies of good practice in e-learning see (Hayes, et al., 2009) in references, supported a group looking at the future of e-learning, and showcased the best of innovation in its e-learning Award. Now for the first time the ELTF membership has come together to undertake an analysis of developments in the member states and to assess what this might mean for the future. The group applied the techniques of World Café conversation and Scenario Thinking to develop its thoughts. The analysis is unashamedly qualitative and draws on expertise from leading universities across eight of the EUNIS member states. What emerges is interesting in terms of the common trends in developments in all of the nations and similarities in hopes and concerns about the future development of learning.
Resumo:
This work looks at the effect on mid-gap interface state defect density estimates for In0.53Ga0.47As semiconductor capacitors when different AC voltage amplitudes are selected for a fixed voltage bias step size (100 mV) during room temperature only electrical characterization. Results are presented for Au/Ni/Al2O3/In0.53Ga0.47As/InP metal–oxide–semiconductor capacitors with (1) n-type and p-type semiconductors, (2) different Al2O3 thicknesses, (3) different In0.53Ga0.47As surface passivation concentrations of ammonium sulphide, and (4) different transfer times to the atomic layer deposition chamber after passivation treatment on the semiconductor surface—thereby demonstrating a cross-section of device characteristics. The authors set out to determine the importance of the AC voltage amplitude selection on the interface state defect density extractions and whether this selection has a combined effect with the oxide capacitance. These capacitors are prototypical of the type of gate oxide material stacks that could form equivalent metal–oxide–semiconductor field-effect transistors beyond the 32 nm technology node. The authors do not attempt to achieve the best scaled equivalent oxide thickness in this work, as our focus is on accurately extracting device properties that will allow the investigation and reduction of interface state defect densities at the high-k/III–V semiconductor interface. The operating voltage for future devices will be reduced, potentially leading to an associated reduction in the AC voltage amplitude, which will force a decrease in the signal-to-noise ratio of electrical responses and could therefore result in less accurate impedance measurements. A concern thus arises regarding the accuracy of the electrical property extractions using such impedance measurements for future devices, particularly in relation to the mid-gap interface state defect density estimated from the conductance method and from the combined high–low frequency capacitance–voltage method. The authors apply a fixed voltage step of 100 mV for all voltage sweep measurements at each AC frequency. Each of these measurements is repeated 15 times for the equidistant AC voltage amplitudes between 10 mV and 150 mV. This provides the desired AC voltage amplitude to step size ratios from 1:10 to 3:2. Our results indicate that, although the selection of the oxide capacitance is important both to the success and accuracy of the extraction method, the mid-gap interface state defect density extractions are not overly sensitive to the AC voltage amplitude employed regardless of what oxide capacitance is used in the extractions, particularly in the range from 50% below the voltage sweep step size to 50% above it. Therefore, the use of larger AC voltage amplitudes in this range to achieve a better signal-to-noise ratio during impedance measurements for future low operating voltage devices will not distort the extracted interface state defect density.
Resumo:
Nucleic Acid hairpins have been a subject of study for the last four decades. They are composed of single strand that is
hybridized to itself, and the central section forming an unhybridized loop. In nature, they stabilize single stranded RNA, serve as nucleation
sites for RNA folding, protein recognition signals, mRNA localization and regulation of mRNA degradation. On the other hand,
DNA hairpins in biological contexts have been studied with respect to forming cruciform structures that can regulate gene expression.
The use of DNA hairpins as fuel for synthetic molecular devices, including locomotion, was proposed and experimental demonstrated in 2003. They
were interesting because they bring to the table an on-demand energy/information supply mechanism.
The energy/information is hidden (from hybridization) in the hairpin’s loop, until required.
The energy/information is harnessed by opening the stem region, and exposing the single stranded loop section.
The loop region is now free for possible hybridization and help move the system into a thermodynamically favourable state.
The hidden energy and information coupled with
programmability provides another functionality, of selectively choosing what reactions to hide and
what reactions to allow to proceed, that helps develop a topological sequence of events.
Hairpins have been utilized as a source of fuel for many different DNA devices. In this thesis, we program four different
molecular devices using DNA hairpins, and experimentally validate them in the
laboratory. 1) The first device: A
novel enzyme-free autocatalytic self-replicating system composed entirely of DNA that operates isothermally. 2) The second
device: Time-Responsive Circuits using DNA have two properties: a) asynchronous: the final output is always correct
regardless of differences in the arrival time of different inputs.
b) renewable circuits which can be used multiple times without major degradation of the gate motifs
(so if the inputs change over time, the DNA-based circuit can re-compute the output correctly based on the new inputs).
3) The third device: Activatable tiles are a theoretical extension to the Tile assembly model that enhances
its robustness by protecting the sticky sides of tiles until a tile is partially incorporated into a growing assembly.
4) The fourth device: Controlled Amplification of DNA catalytic system: a device such that the amplification
of the system does not run uncontrollably until the system runs out of fuel, but instead achieves a finite
amount of gain.
Nucleic acid circuits with the ability
to perform complex logic operations have many potential practical applications, for example the ability to achieve point of care diagnostics.
We discuss the designs of our DNA Hairpin molecular devices, the results we have obtained, and the challenges we have overcome
to make these truly functional.
Resumo:
The goal of this research is to produce a system for powering medical implants to increase the lifetime of the implanted devices and reduce the battery size. The system consists of a number of elements – the piezoelectric material for generating power, the device design, the circuit for rectification and energy storage. The piezoelectric material is analysed and a process for producing a repeatable high quality piezoelectric material is described. A full width half maximum (FWHM) of the rocking curve X-Ray diffraction (XRD) scan of between ~1.5° to ~1.7° for test wafers was achieved. This is state of the art for AlN on silicon and means devices with good piezoelectric constants can be fabricated. Finite element modelling FEM) was used to design the structures for energy harvesting. The models developed in this work were established to have an accuracy better than 5% in terms of the difference between measured and modelled results. Devices made from this material were analysed for power harvesting ability as well as the effect that they have on the flow of liquid which is an important consideration for implantable devices. The FEM results are compared to experimental results from laser Doppler vibrometry (LDV), magnetic shaker and perfusion machine tests. The rectifying circuitry for the energy harvester was also investigated. The final solution uses multiple devices to provide the power to augment the battery and so this was a key feature to be considered. Many circuits were examined and a solution based on a fully autonomous circuit was advanced. This circuit was analysed for use with multiple low power inputs similar to the results from previous investigations into the energy harvesting devices. Polymer materials were also studied for use as a substitute for the piezoelectric material as well as the substrate because silicon is more brittle.