928 resultados para Robust Multivariable Controller Design


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article addresses the problem of obtaining reduced complexity models of multi-reach water delivery canals that are suitable for robust and linear parameter varying (LPV) control design. In the first stage, by applying a method known from the literature, a finite dimensional rational transfer function of a priori defined order is obtained for each canal reach by linearizing the Saint-Venant equations. Then, by using block diagrams algebra, these different models are combined with linearized gate models in order to obtain the overall canal model. In what concerns the control design objectives, this approach has the advantages of providing a model with prescribed order and to quantify the high frequency uncertainty due to model approximation. A case study with a 3-reach canal is presented, and the resulting model is compared with experimental data. © 2014 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An approach for the analysis of uncertainty propagation in reliability-based design optimization of composite laminate structures is presented. Using the Uniform Design Method (UDM), a set of design points is generated over a domain centered on the mean reference values of the random variables. A methodology based on inverse optimal design of composite structures to achieve a specified reliability level is proposed, and the corresponding maximum load is outlined as a function of ply angle. Using the generated UDM design points as input/output patterns, an Artificial Neural Network (ANN) is developed based on an evolutionary learning process. Then, a Monte Carlo simulation using ANN development is performed to simulate the behavior of the critical Tsai number, structural reliability index, and their relative sensitivities as a function of the ply angle of laminates. The results are generated for uniformly distributed random variables on a domain centered on mean values. The statistical analysis of the results enables the study of the variability of the reliability index and its sensitivity relative to the ply angle. Numerical examples showing the utility of the approach for robust design of angle-ply laminates are presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This article addresses the problem of obtaining reduced complexity models of multi-reach water delivery canals that are suitable for robust and linear parameter varying (LPV) control design. In the first stage, by applying a method known from the literature, a finite dimensional rational transfer function of a priori defined order is obtained for each canal reach by linearizing the Saint-Venant equations. Then, by using block diagrams algebra, these different models are combined with linearized gate models in order to obtain the overall canal model. In what concerns the control design objectives, this approach has the advantages of providing a model with prescribed order and to quantify the high frequency uncertainty due to model approximation. A case study with a 3-reach canal is presented, and the resulting model is compared with experimental data. © 2014 IEEE.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper proposes a multifunctional architecture to implement field-programmable gate array (FPGA) controllers for power converters and presents a prototype for a pulsed power generator based on a solid-state Marx topology. The massively parallel nature of reconfigurable hardware platforms provides very high processing power and fast response times allowing the implementation of many subsystems in the same device. The prototype includes the controller, a failure detection system, an interface with a safety/emergency subsystem, a graphical user interface, and a virtual oscilloscope to visualize the generated pulse waveforms, using a single FPGA. The proposed architecture employs a modular design that can be easily adapted to other power converter topologies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Prototype validation is a major concern in modern electronic product design and development. Simulation, structural test, functional and timing debug are all forming parts of the validation process, although very often addressed as dissociated tasks. In this paper we describe an integrated approach to board-level prototype validation, based on a set of mandatory/optional BST instructions and a built-in controller for debug and test, that addresses the late mentioned tasks as inherent parts of a whole process

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RESUMO: As concentrações circulantes de cálcio são notavelmente constantes a despeito das variações diárias na absorção intestinal e na eliminação renal deste elemento. A regulação da calcémia é um sistema complexo que compreende vários factores controladores (a calcémia, a fosforémia, as concentrações circulantes de paratormona (PTH) e calcitriol além de muitos outros factores como hormonas esteróides em geral, outros iões como o magnésio e outros factores hormonais) e vários órgãos alvo (glândulas paratiroideias, osso, rim e intestino). As respostas dos órgãos alvo também são muito variadas. No caso mais simples, a cristalização de sais de cálcio corresponde a uma mudança de fase em que participam moléculas orgânicas que a iniciam, aceleram ou inibem. Em geral a combinação de um factor controlador com o respectivo receptor de membrana (para polipeptídeos ou iões) ou intracelular (hormonas esteróides) é apenas o primeiro passo de uma cadeia bioquímica que introduz uma enorme amplificação na resposta. A esta variedade de mecanismos de resposta correspondem grandes diferenças nos tempos de resposta que podem ser de minutos a semanas. É hoje possível “observar” (medir) com apreciável rigor nos líquidos biológicos (sangue, urina, fezes, etc.) os factores mais importantes do sistema de regulação da calcémia (cálcio, fósforo, paratormona e calcitriol) assim como administrar estes factores em experiências agudas. Esta possibilidade reflecte – se na literatura neste campo que tem vindo a crescer. O advento das técnicas da biologia molecular tem permitido a caracterização molecular de algumas das disfunções da homeostase do cálcio e é de esperar um diagnóstico fisiopatológico cada vez mais rigoroso dessas disfunções. Com o avanço dos conhecimentos nesta área que não cessa de aumentar temos cada vez maiores capacidades para fazer diagnósticos e é cada vez mais difícil interpretar com rigor os correspondentes quadros metabólicos. A análise ou síntese de sistemas complexos é a actividade mais nobre dos engenheiros que lhes permite desenhar pontes, diques, barcos, aviões ou automóveis. Com o aparecimento de computadores de médio ou grande porte foi – lhes possível utilizar descrições matemáticas não só para desenhar sistemas como ainda para interpretar eventuais falhas na sua operação. Essas descrições matemáticas consistem numa sequência de operações realizadas num computador segundo um “programa informático” que receberam a designação genérica de modelos, por analogia com as famosas leis (equações) da física que foram deduzidas a partir de um certo número de postulados e que permitem representar matematicamente processos físicos. As famosas leis de Newton são talvez os exemplos mais famosos de “modelos” de sistemas físicos. A introdução de modelos matemáticos em biologia e particularmente em medicina só se deu recentemente.MÉTODOS No trabalho que aqui se apresenta construiu - se um modelo simplificado da homeostase do cálcio destinado ao cálculo de variáveis observáveis (concentrações de cálcio, fósforo, PTH e calcitriol) de modo a poderem comparar-se valores calculados com valores observados. A escolha dos componentes do modelo foi determinada pela nossa experiência clínica e pela informação fisiopatológica e clínica publicada. Houve a preocupação de construir o modelo de forma modular de modo a ser possível a sua expansão sem grandes transformações na descrição matemática (e informática) já existente. Na sua fase actual o modelo não pode ser usado como instrumento de diagnóstico. É antes uma ferramenta destinada a esclarecer “em princípio” mecanismos fisiopatológicos. Usou – se o modelo para simular um certo número de observações publicadas e para exemplificar a sua eventual aplicação clínica na simulação de situações hipotéticas e na análise de possíveis mecanismos fisiopatológicos responsáveis por situações de hipo ou hipercalcémias. Simultaneamente fez – se uma análise dos dados acumulados relativos a doentes vistos no Serviço de Endocrinologia do Instituto Português de Oncologia de Francisco Gentil – Centro Regional Oncológico de Lisboa, S.A. CONCLUSÕES Numa população de 894 doentes com patologias variadas do Instituto Português de Oncologia de Lisboa os valores da calcémia tiveram uma distribuição normal unimodal com uma média de 9.56 mg/dl, e um erro padrão de 0.41 mg/dl. Estas observações sugerem que a calcémia está sujeita a regulação. A partir dos resultados publicados em que o metabolismo do cálcio foi perturbado por infusões de cálcio, calcitriol ou PTH, de estudos bioquímicos e fisiológicos sobre os mecanismos de acção de factores controladores da calcémia e do estudo do comportamento de órgãos alvo (paratiroideias, intestino, osso e rim) foi possível construir um modelo matemático de parâmetros concentrados do sistema de regulação da calcémia. As expressões analíticas usadas foram baseadas na cinética enzimática de modo a que os seus parâmetros tivessem um significado físico ou fisiológico simples. O modelo revelou apreciável robustez e flexibilidade. É estável quando não perturbado e transita entre estados estacionários quando perturbado. Na sua forma actual gera simulações que reproduzem satisfatoriamente um número apreciável de dados experimentais colhidos em doentes. Isto não significa que possa ser usado como instrumento de diagnóstico aplicável a doentes individuais. O desenho do modelo comporta a adição posterior de novas relações quando surgirem situações para as quais se revele insuficiente. A utilização exaustiva do modelo permitiu explicitar aspectos do metabolismo do cálcio que ou não estão contidas na sua formulação actual – o aparecimento de hipertrofia ou de adenomas das paratiroideias e as alterações na estrutura óssea , a participação de outros factores controladores – magnésio, ou estão insuficientemente descritas – alterações do metabolismo do fósforo nos hipoparatiroidismos. A análise dos dados relativos aos doentes do Serviço de Endocrinologia do IPO permitiu o início da caracterização dos tipos de patologia que representam e de possíveis mecanismos fisiopatológicos subjacentes. Estas observações são o ponto de partida para análises futuras. São exemplos das relações encontradas: a distribuição dos doentes por dois grandes grupos conforme a calcémia é determinada pelas concentrações circulantes de PTH ou estas são determinadas pela calcémia; a distribuição sazonal das concentrações de Vit. D25. no sangue; a correlação negativa entre estas e as concentrações de PTH no sangue. Também foi possível extrair a cinética do controlo da PTH sobre a síntese de calcitriol. O estudo dos níveis circulantes de PTH no pós-operatório imediato de doentes paratiroidectomizados permitiu determinar as suas taxas de degradação metabólica. O modelo permitiu simular as relações Ca/PTH no sangue, Ca/Fracção excretada da carga tubular, Ca/P no sangue para valores normais ou altos de Ca. Foram feitas simulações de situações fisiopatológicas (em “doentes virtuais”): infusões crónicas de cálcio, PTH e calcitriol; alterações no comportamento de receptores. Estas simulações correspondem a experiências que não podem ser realizadas em humanos. São exemplos da utilização do modelo na exploração de possíveis mecanismos fisiopatológicos através da observação de resultados quantitativos inacessíveis à intuição. O modelo foi útil em duas fases do trabalho: Primeiro, durante a sua síntese implicou uma escolha criticamente selectiva de informação, sua análise quantitativa e processamento, uma explicitação rigorosa (analítica) das relações funcionais entre os controladores e as variáveis e da sua integração numa estrutura global; Segundo, a simulação de situações experimentais ou clínicas (dados do Serviço de Endocrinologia do IPO) em doentes obrigou a explicitar raciocínios fisiopatológicos habitualmente formulados em bases puramente intuitivas. Esta prática revelou comportamentos óbvios após as simulações – acção reduzida das infusões PTH (simulação de hiperparatiroidismos primários) enquanto não há inibição total da respectiva secreção, necessidade de aumento da massa secretora da paratiroideia nas insuficiências renais avançadas, etc. A síntese e utilização do modelo não implicaram uma preparação matemática avançada e foram possíveis mercê da disponibilidade de “software” interactivo especificamente desenhado para a simulação de sistemas dinâmicos em que os programas se escrevem em inglês usando a simbologia simples da álgebra elementar. A função nobre de modelos desta natureza é semelhante à dos modelos usados pelos físicos desde o século XVII: permitir explicações de carácter geral funcionando como uma ferramenta intelectual para manipulação de conceitos e para a realização de “experiências pensadas” (“thought experiments”) respeitando certos princípios físicos (princípios de conservação) que estabelecem as fronteiras da realidade. -------ABSTRACT: Calcium blood levels are remarkably constant despite great variations in calcium daily intake, intestinal absorption and renal excretion. The regulation of the calcium concentration in the blood is achieved by a complex system that includes several controller factors (mainly the serum levels of calcium, phosphorus, parathyroid hormone (PTH) and calcitriol but also of steroid hormones, ions such as magnesium and other hormonal factors) and several target organs (parathyroid glands, bone, kidney and intestine). The functional response to the controlling factors obeys a variety of kinetics. The precipitation of calcium salts is a simple phase transition in which organic molecules may provide nucleation centres or inhibit the process. The combination of a controller factor with its receptor located in the cell membrane (for peptides or ions) or in the nucleus (for steroid hormones) is only the first step of a biochemical chain that introduces a huge amplification in the response. To this great variability of response we have to add the times of response that vary from minutes to weeks. It is possible to “observe” (measure) with great accuracy in biological fluids (blood, urine, faeces, etc.) the most important factors intervening in the calcium regulation (calcium, phosphorus, PTH and calcitriol). The response of the system to acute infusions of the controlling factors has also been studied. Using molecular biology techniques it has been possible to characterize some calcium homeostasis dysfunctions and better physiopathological diagnosis are expected. With the increasingly new knowledge in this area we have better capacity to diagnose but it is harder to explain correctly the underlying metabolic mechanisms. The analysis or synthesis of complex systems is the noble activity of engineers that enables them to draw bridges, dams, boats, airplanes or cars. With the availability of medium-large frame computers it was possible to use mathematical descriptions not only to draw systems but also to explain flaws in its operations. These mathematical descriptions are generally known as models by analogy with the laws (equations) of physics that allow the mathematical description of physical processes. In practice it is not possible to find general solutions for the mathematical descriptions of complex systems but (numeric) computations for specific situations can be obtained with digital computers. The introduction of mathematical models in biology and particularly in medicine is a recent event. METHODS In this thesis a simplified model of calcium homeostasis was built that enables the computation of observable variables (concentrations of calcium, phosphorus, PTH and calcitriol) and allows the comparison between the simulation values and observed values. The choice of the model’s components was made according to our clinical experience and to the published clinical and physiopathological data. The model has a modular design that allows future expansions with minor alterations in its structure. In its present form the model cannot be used for diagnosis. It is a tool designed to enlighten physiopathological processes. To exemplify its possible clinical application in the simulation of hypothetical situations and in the analysis of possible mechanisms responsible for hypo or hypercalcemias the model was used to simulate a certain number of published observations. An analysis of clinical and laboratory data from the Endocrinology Department of the Portuguese Cancer Institute (I.P.O.F.G.-C.R.O.L.,S.A.) is also presented. CONCLUSIONS In a population of 188 patients without an identifiable disease of the calcium metabolism at the Portuguese Cancer Institute the calcemia levels had a unimodal distribution with an average of 9.56 mg/dL and a S.E.M of 0.41 mg/dL. This observation confirms that serum calcium is regulated. Using published data; in which calcium metabolism was disrupted by calcium, PTH or calcitriol infusions; from biochemical and physiological studies of the action of controller factors on the calcemia; in which the response of target organs (parathyroid glands, intestine, bone, kidney) was studied it was possible to build a mathematical model of concentrated parameters of the calcium homeostasis. Analytical expressions used were based on enzymatic kinetics. The model is flexible and robust. It is stable when not disturbed and changes between steady states when disturbed. In its present form it provides simulations that reproduce closely a number of experimental clinical data. This does not mean that it can be used as a diagnostic tool for individual patients. The exhaustive utilisation of the model revealed the need of future expansions to include aspects of the calcium metabolism not included in its present form –hypertrophy or adenomas of the parathyroid glands, bone structure changes, participation of other controller factors such as magnesium – or insufficiently described – phosphate metabolism in hypoparathyroidism. The analysis of the data collected from the I.P.O.’s Endocrinology Department allowed the initial characterization of the different pathologies represented and of their possible physiopathological mechanisms. These observations are a starting point for future analysis. As examples of the relations found were: the distribution of patients in two groups according to the dependency of calcium by PTH levels or PTH levels by calcium concentration; the seasonal distribution of the serum concentrations of D25; its negative correlation with PTH concentration. It was also possible to extract the kinetics of the control of the synthesis of calcitriol by PTH. The analysis of immediate post-surgical levels of PTH in parathyroidectomized patients allowed the determination of its metabolic clearance. The model also allowed the simulation of the relations between Ca/PTH in blood, serum Ca/Fraction of tubular load excreted and Ca/P in blood for normal and high values of calcium. Simulations were made of pathological situations (in “virtual patients”): chronic infusions of calcium, PTH and calcitriol; changes in the characteristics of receptors. These simulations are not possible in real persons. They are an example of the use of this model in exploring possible mechanisms of disease through the observation of quantitative results not accessible to simple intuition. This model was useful in two phases: Firstly, its construction required a careful choice of data, its quantitative analysis and processing, an analytical description of the relations between controller factors and variables and their integration in a global structure. Secondly, the simulation of experimental or clinical (I.P.O.’s Endocrinology Department) data implied testing physiopathological explanations that previously were based on intuition. The construction and utilisation of the model didn’t demand an advanced mathematical preparation since user-friendly interactive software was used. This software was specifically designed for the simulation of dynamic systems. The programs are written in English using elementary algebra symbols. The essential function of this type of models is identical to that of those used by physicists since the XVII century which describe quantitatively natural processes and are an intellectual tool for the manipulation of concepts and the performance of “thought experiments” based in certain physical principles (conservation principles) that are the frontiers of reality.------------------RESUMÉE: Les concentrations circulantes de calcium sont constantes même pendant des variations de l’absorption intestinale et de l’élimination rénale de cet élément. La régulation de la calcémie est un système complexe qui comprend plusieurs éléments contrôleurs (la calcémie, la phosphorémie, les concentrations circulantes de l’hormone parathyroïdienne (PTH) e du calcitriol et d’autres comme les hormones stéroïdes ou des ions comme le magnésium) et plusieurs organes (glandes parathyroïdiennes, l’os, le rein et l’intestin). Les réponses de ces organes sont variées. Dans le cas plus simple, la cristallisation des sels de calcium correspond à un changement de phase dans lequel y participent des molécules organiques que la débutent, l’accélèrent ou l’inhibent. Généralement la combinaison d’un élément contrôleur avec leur récepteur de membrane (pour les peptides ou les ions) ou intracellulaire (pour les hormones stéroïdes) n’est que le premier pas d’une chaîne biochimique qu’introduit une grande amplification de la réponse. A cette variété de réponses correspondent des grandes différences des temps de réponses qu’y vont des minuits a semaines. Il est possible « observer » (mesurer) dans les fluides biologiques (sang, urine, fèces, etc.) les éléments plus importants du système de régulation de la calcémie (calcium, phosphate, PTH et le calcitriol) et les administrer en expérimentes aigus. Cette possibilité est visible dans la littérature publiée dans ce domaine qui est en croissance permanente. L’avenir des techniques de biologie moléculaire a permis caractériser des nombreuses dysfonctions de la régulation de la calcémie et on attend un diagnostique physiopathologique de ces dysfonctions chaque fois plus rigoureuses. Les connaissances dans ce domaine s’agrandissent et on a de plus de capacités pour faire des diagnostiques et il est chaque fois plus difficile les interpréter. L’analyse ou synthèse de systèmes complexes est l’activité plus noble des ingénieurs qui les permit dessiner des ponts, bateaux, avions ou automobiles. Avec des ordinateurs de médium ou grand port il les est possible utiliser descriptions mathématiques pour dessiner les systèmes et interpréter des éventuelles fautes d’opération. Ces descriptions mathématiques sont une séquence d’opérations réalisées dans un ordinateur selon « un programme informatique » qui ont reçu la désignation générique de modèles, pour analogie avec les équations de la physique qui ont été déduits d’un nombre de postulées et qu’ont permit représenter des processus physiques en équations mathématiques. Les fameuses équations de Newton sont peut-être les exemples plus connus des systèmes physiques. L’introduction des modèles mathématiques en biologie et en particulier en médecine est un évènement récent. Dans ce travaille, on a construit un modèle simplifié de l’homéostasie du calcium pour calculer les variables observables (concentrations de calcium, phosphate, PTH et calcitriol) pour les comparer. Les choix des components a été déterminés par notre expérience clinique et par l’information physiopathologique et clinique publiée. Le modèle a été construit de façon modulaire ce que permit leur postérieur expansion sans des grandes altérations dans la description mathématique et informatique déjà existante. Dans cette forme le modèle ne peut être utilisé comme un instrument de diagnostique. Il est un outil pour éclairer la physiopathologie. Le modèle a été utilisé pour simuler un certain nombre d’observations publiées et pour exemplifier leur possible utilisation clinique dans la simulation des hypothèses et de la physiopathologie des situations d’hypo ou hypercalcémie. On a fait une analyse des éléments des procès cliniques des malades observées dans le Service d’Endocrinologie de l’IPOFG-CROL, SA. Dans une population de 894 malades avec des différentes pathologies les valeurs de calcémie on une distribution uni modale avec une Médie de 9.56 mg/dL et une erreur standard de 0.41 mg/dL. Ces observations suggèrent que la calcémie soit sujette de régulation. En utilisant des résultats de travaux publiés dans lesquels le métabolisme du calcium a été changé par des infusions de calcium, calcitriol ou PTH, des études biochimiques et physiologiques sur des mécanismes d’action des éléments contrôleurs de la calcémie et de l’étude du comportement des organes cible (parathyroïdes, intestin, rein, os), il a été possible de construire un modèle mathématique de paramètres concentrés du système de régulation de la calcémie. Les expressions analytiques utilisées ont été basées sur la cinétique enzymatique de façon à que les paramètres aient eu une signification physique ou biologique. Le modèle est stable quand il n’est pas perturbé et transit entre états stationnaires quand il est sujet a des perturbations. A ce moment il fait des simulations qui reproduisent de façon satisfaisant un nombre d’observations expérimentales. La construction du modèle permit l’addiction de nouvelles relations dans les cas ou il est insuffisant. L’utilisation exhaustive du modèle a permit expliciter des aspects du métabolisme du calcium qui y ne sont pas compris – l’hyperplasie ou la formation des adénomes des parathyroïdes, les altérations de la structure des os, la participation d’outres éléments régulateurs (magnésium), ou sont insuffisamment décrites – les altérations du métabolisme des phosphates dans l’hypoparathyroidism. L’analyse de l’information des malades du Service d’Endocrinologie a permit caractériser les pathologies représentées et leurs possibles mécanismes physiopathologiques. Ces observations sont le point de départ pour les analyses futures. Sont des exemples des relations trouvées: la distribution des malades par deux groupes: ceux dans lequel la calcémie est déterminée par la PTH ou ceux dans lesquels la PTH est déterminée par la calcémie; la distribution sazonale de la concentration de la vitamine D; la corrélation négative entre la vitamine D et la PTH. On a eu la possibilité de déduire la cinétique de control de la PTH sur la synthèse du calcitriol. L’étude des niveaux circulants de PTH sur des sujets parathyroidectomisées a permit déduire leur taux de dégradation métabolique. Le modèle a permit simuler les relations Ca/PTH dans le sang, Ca/fraction éliminée par le rein, Ca/P dans le sang pour des valeurs normales ou hautes de calcium. On a fait des simulations de situations physiopathologiques (dans “malades virtuelles”): Infusions chroniques de calcium, PTH ou calcitriol; altérations des récepteurs. Ces simulations ne peuvent pas être réalisées dans les humains. Sont des exemples d’utilisation du modèle dans l’exploration des possibles mécanismes de la physiopathologie en observant des résultats quantitatifs inaccessibles à l’intuition. Le modèle a été utile pendant deux étapes des travaux: La première, dans sa construction on a choisi l’information disponible, son analyse quantitative, l’explicitation rigoureuse (analytique) des relations fonctionnelles entre les contrôleurs et les variables et sa intégration dans une structure globale. La deuxième, la simulation de situations expérimentales ou cliniques (du Service d’Endocrinologie) a obligé d’expliciter des raisonnements physiopathologiques généralement formulés utilisant l’intuition. Cette pratique a montré des comportements – action réduite des infusions de PTH (jusqu’à l’inhibition totale de leur respective sécrétion), nécessité d’augmenter la masse sécréteuse de la parathyroïde dans les insuffisants rénales, etc. La synthèse et utilisation du modèle n’ont pas besoin d’une formation avancée en mathématique et sont possibles grâce à un programme interactif qui a été conçu pour la simulation des systèmes dynamiques dans lesquels le programme se construit en anglais en utilisant la symbolique élémentaire de l’algèbre. La fonction noble de ces modèles est semblable à celles des physiques du XVII siècle: Permettre établir explications générales en fonctionnant comme un outil intellectuel pour manipuler des concepts et pour la réalisation d’expérimentes pensées en respectant certains principes de la physique (principe de la conservation) qu’établissent les frontières de la réalité.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An adaptive control damping the forced vibration of a car while passing along a bumpy road is investigated. It is based on a simple kinematic description of the desired behavior of the damped system. A modified PID controller containing an approximation of Caputo’s fractional derivative suppresses the high-frequency components related to the bumps and dips, while the low frequency part of passing hills/valleys are strictly traced. Neither a complete dynamic model of the car nor ’a priori’ information on the surface of the road is needed. The adaptive control realizes this kinematic design in spite of the existence of dynamically coupled, excitable internal degrees of freedom. The method is investigated via Scicos-based simulation in the case of a paradigm. It was found that both adaptivity and fractional order derivatives are essential parts of the control that can keep the vibration of the load at bay without directly controlling its motion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Manipulator systems are rather complex and highly nonlinear which makes difficult their analysis and control. Classic system theory is veil known, however it is inadequate in the presence of strong nonlinear dynamics. Nonlinear controllers produce good results [1] and work has been done e. g. relating the manipulator nonlinear dynamics with frequency response [2–5]. Nevertheless, given the complexity of the problem, systematic methods which permit to draw conclusions about stability, imperfect modelling effects, compensation requirements, etc. are still lacking. In section 2 we start by analysing the variation of the poles and zeros of the descriptive transfer functions of a robot manipulator in order to motivate the development of more robust (and computationally efficient) control algorithms. Based on this analysis a new multirate controller which is an improvement of the well known “computed torque controller” [6] is announced in section 3. Some research in this area was done by Neuman [7,8] showing tbat better robustness is possible if the basic controller structure is modified. The present study stems from those ideas, and attempts to give a systematic treatment, which results in easy to use standard engineering tools. Finally, in section 4 conclusions are presented.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The potential of human adenovirus vectors as vehicles for gene transfer with clinical applications in vaccination, cancer treatment and in many monogenic and acquired diseases has been demonstrated in several studies and clinical trials. However, the clinical use of these vectors can be limited by pre-existing humoral and cellular anti-capsid immunity. One way to circumvent this bottleneck while keeping the advantages of using adenovirus vectors is using non-human viruses such as Canine Adenovirus type 2 (CAV-2). Moreover, CAV-2 vectors present attractive features to develop potential treatment of neurodegenerative and ocular disorders. While the interest in CAV-2 vectors increases, scalable and robust production processes are required to meet the need for preclinical and possibly clinical uses.(...)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The report addresses the question of what are the preferences of broadband consumers on the Portuguese telecommunication market. A triple play bundle is being investigated. The discrete choice analysis, adopted in the study, base on 110 responses, mainly from NOVA students. The data for the analysis was collected via manually designed on-line survey. The results show that the price attribute is relatively the most important one while the television attribute is being overlooked in the decision making process. Main effects examined in the research are robust. In addition, "extras" components are being tested in terms of users' preferences.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Failure to detect a species in an area where it is present is a major source of error in biological surveys. We assessed whether it is possible to optimize single-visit biological monitoring surveys of highly dynamic freshwater ecosystems by framing them a priori within a particular period of time. Alternatively, we also searched for the optimal number of visits and when they should be conducted. We developed single-species occupancy models to estimate the monthly probability of detection of pond-breeding amphibians during a four-year monitoring program. Our results revealed that detection probability was species-specific and changed among sampling visits within a breeding season and also among breeding seasons. Thereby, the optimization of biological surveys with minimal survey effort (a single visit) is not feasible as it proves impossible to select a priori an adequate sampling period that remains robust across years. Alternatively, a two-survey combination at the beginning of the sampling season yielded optimal results and constituted an acceptable compromise between sampling efficacy and survey effort. Our study provides evidence of the variability and uncertainty that likely affects the efficacy of monitoring surveys, highlighting the need of repeated sampling in both ecological studies and conservation management.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Immunotherapy is defined as the treatment of disease by inducing, enhancing, or suppressing an immune response, whereas preventive vaccination is intended to prevent the development of diseases in healthy subjects. Most successful prophylactic vaccines rely on the induction of high titers of neutralizing antibodies. It is generally thought that therapeutic vaccination requires induction of robust T-cell mediated immunity. The diverse array of potential or already in use immunotherapeutic and preventive agents all share the commonality of stimulating the immune system. Hence, measuring those vaccination-induced immune responses gives the earliest indication of vaccine take and its immune modulating effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective the present research is try to find some control design strategies, which must be effective and closed to the real operation conditions. As a novel contribution to structural control strategies, the theories of Interval Modal Arithmetic, Backstepping Control and QFT (Qualitative Feedback Theory) will be studied. The steps to follow are to develop first new controllers based on the above theories and then to implement the proposed control strategies to different kind of structures. The report is organized as follows. The Chapter 2 presents the state-of-the-art on structural control systems. The chapter 3 presents the most important open problems found in field of structural control. The exploratory work made by the author, research proposal and working plan are given in the Chapter 4

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Cobre Las Cruces is a renowned copper mining company located in Sevilla, with unexpected problems in wireless communications that have a direct affectation in production. Therefore, the main goals are to improve the WiFi infrastructure, to secure it and to detect and prevent from attacks and from the installation of rogue (and non-authorized) APs. All of that integrated with the current ICT infrastructure.This project has been divided into four phases, although only two of them have been included into the TFC; they are the analysis of the current situation and the design of a WLAN solution.Once the analysis part was finished, some weaknesses were detected. Subjects such as lack of connectivity and control, ignorance about installed WiFi devices and their localization and state and, by and large, the use of weak security mechanisms were some of the problems found. Additionally, due to the fact that the working area became larger and new WiFi infrastructures were added, the first phase took more time than expected.As a result of the detailed analysis, some goals were defined to solve and it was designed a centralized approach able to cope with them. A solution based on 802.11i and 802.1x protocols, digital certificates, a probe system running as IDS/IPS and ligthweight APs in conjunction with a Wireless LAN Controller are the main features.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Agent-based computational economics is becoming widely used in practice. This paperexplores the consistency of some of its standard techniques. We focus in particular on prevailingwholesale electricity trading simulation methods. We include different supply and demandrepresentations and propose the Experience-Weighted Attractions method to include severalbehavioural algorithms. We compare the results across assumptions and to economic theorypredictions. The match is good under best-response and reinforcement learning but not underfictitious play. The simulations perform well under flat and upward-slopping supply bidding,and also for plausible demand elasticity assumptions. Learning is influenced by the number ofbids per plant and the initial conditions. The overall conclusion is that agent-based simulationassumptions are far from innocuous. We link their performance to underlying features, andidentify those that are better suited to model wholesale electricity markets.