847 resultados para Robotic manipulators


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The main objective is to develop methods that automatically generate kinematic models for the movements of biological and robotic systems. Two methods for the identification of the kinematics are presented. The first method requires the elimination of the displacement variables that cannot be measured while the second method attempts to estimate the changes in these variables. The methods were tested using a planar two-revolute-joint linkage. Results show that the model parameters obtained agree with the actual parameters to within 5%. Moreover, the methods were applied to model head and neck movements in the sagittal plane. The results indicate that these movements are well modeled by a two-revolute-joint system. A spatial three-revolute-joint model was also discussed and tested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increasingly socially intelligent agents (software or robotic) are used in education, rehabilitation and therapy. This paper discusses the role of interactive, mobile robots as social mediators in the particular domain of autism therapy. This research is part of the project AURORA that studies how mobile robots can be used to teach children with autism basic interaction skills that are important in social interactions among humans. Results from a particular series of trials involving pairs of two children and a mobile robot are described. The results show that the scenario with pairs of children and a robot creates a very interesting social context which gives rise to a variety of different social and non-social interaction patterns, demonstrating the specific problems but also abilities of children with autism in social interactions. Future work will include a closer analysis of interactional structure in human-human and robot-human interaction. We outline a particular framework that we are investigating.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ‘action observation network’ (AON), which is thought to translate observed actions into motor codes required for their execution, is biologically tuned: it responds more to observation of human, than non-human, movement. This biological specificity has been taken to support the hypothesis that the AON underlies various social functions, such as theory of mind and action understanding, and that, when it is active during observation of non-human agents like humanoid robots, it is a sign of ascription of human mental states to these agents. This review will outline evidence for biological tuning in the AON, examining the features which generate it, and concluding that there is evidence for tuning to both the form and kinematic profile of observed movements, and little evidence for tuning to belief about stimulus identity. It will propose that a likely reason for biological tuning is that human actions, relative to non-biological movements, have been observed more frequently while executing corresponding actions. If the associative hypothesis of the AON is correct, and the network indeed supports social functioning, sensorimotor experience with non-human agents may help us to predict, and therefore interpret, their movements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent research in cognitive neuroscience has found that observation of human actions activates the ‘mirror system’ and provokes automatic imitation to a greater extent than observation of non-biological movements. The present study investigated whether this human bias depends primarily on phylogenetic or ontogenetic factors by examining the effects of sensorimotor experience on automatic imitation of non-biological robotic, stimuli. Automatic imitation of human and robotic action stimuli was assessed before and after training. During these test sessions, participants were required to execute a pre-specified response (e.g. to open their hand) while observing a human or robotic hand making a compatible (opening) or incompatible (closing) movement. During training, participants executed opening and closing hand actions while observing compatible (group CT) or incompatible movements (group IT) of a robotic hand. Compatible, but not incompatible, training increased automatic imitation of robotic stimuli (speed of responding on compatible trials, compared with incompatible trials) and abolished the human bias observed at pre-test. These findings suggest that the development of the mirror system depends on sensorimotor experience, and that, in our species, it is biased in favour of human action stimuli because these are more abundant than non-biological action stimuli in typical developmental environments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Visual observation of human actions provokes more motor activation than observation of robotic actions. We investigated the extent to which this visuomotor priming effect is mediated by bottom-up or top-down processing. The bottom-up hypothesis suggests that robotic movements are less effective in activating the ‘mirror system’ via pathways from visual areas via the superior temporal sulcus to parietal and premotor cortices. The top-down hypothesis postulates that beliefs about the animacy of a movement stimulus modulate mirror system activity via descending pathways from areas such as the temporal pole and prefrontal cortex. In an automatic imitation task, subjects performed a prespecified movement (e.g. hand opening) on presentation of a human or robotic hand making a compatible (opening) or incompatible (closing) movement. The speed of responding on compatible trials, compared with incompatible trials, indexed visuomotor priming. In the first experiment, robotic stimuli were constructed by adding a metal and wire ‘wrist’ to a human hand. Questionnaire data indicated that subjects believed these movements to be less animate than those of the human stimuli but the visuomotor priming effects of the human and robotic stimuli did not differ. In the second experiment, when the robotic stimuli were more angular and symmetrical than the human stimuli, human movements elicited more visuomotor priming than the robotic movements. However, the subjects’ beliefs about the animacy of the stimuli did not affect their performance. These results suggest that bottom-up processing is primarily responsible for the visuomotor priming advantage of human stimuli.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent behavioural and neuroimaging studies have found that observation of human movement, but not of robotic movement, gives rise to visuomotor priming. This implies that the 'mirror neuron' or 'action observation–execution matching' system in the premotor and parietal cortices is entirely unresponsive to robotic movement. The present study investigated this hypothesis using an 'automatic imitation' stimulus–response compatibility procedure. Participants were required to perform a prespecified movement (e.g. opening their hand) on presentation of a human or robotic hand in the terminal posture of a compatible movement (opened) or an incompatible movement (closed). Both the human and the robotic stimuli elicited automatic imitation; the prespecified action was initiated faster when it was cued by the compatible movement stimulus than when it was cued by the incompatible movement stimulus. However, even when the human and robotic stimuli were of comparable size, colour and brightness, the human hand had a stronger effect on performance. These results suggest that effector shape is sufficient to allow the action observation–matching system to distinguish human from robotic movement. They also indicate, as one would expect if this system develops through learning, that to varying degrees both human and robotic action can be 'simulated' by the premotor and parietal cortices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this article is to identify the key factors that are associated with the adoption of a commercial robot in the home. This article is based on the development of the robot product Cybot by the University of Reading in conjunction with a publisher (Eaglemoss International Ltd.). The robots were distributed through a new part-work magazine series (Ultimate Real Robots) that had long-term customer usage and retention. A part-work is a serial publication that is issued periodically (e.g., every two weeks), usually in magazine format, and builds into a complete collection. This magazine focused on robotics and was accompanied by cover-mounted component parts that could be assembled, with instructions, by the user to build a working robot over the series. In total, the product contributed over half a million operational domestic robots to the world market, selling over 20 million robot part-work magazines across 18 countries, thereby providing a unique breadth of insight. Gaining a better understanding of the overall attitudes that customers of this product had toward robots in the home, their perception of what such devices could deliver and how they would wish to interact with them should provide results applicable to the domestic appliance, assistance/care, entertainment, and educational markets.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors address the problems in using a fiber-optic proximity sensor to detect robot end-effector positioning errors in performing a contact task when uncertainties about target position exist. An extended Kalman filter approach is employed to solve the nonlinear filtering problem. Some experimental results are given.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Spiking neural networks are usually limited in their applications due to their complex mathematical models and the lack of intuitive learning algorithms. In this paper, a simpler, novel neural network derived from a leaky integrate and fire neuron model, the ‘cavalcade’ neuron, is presented. A simulation for the neural network has been developed and two basic learning algorithms implemented within the environment. These algorithms successfully learn some basic temporal and instantaneous problems. Inspiration for neural network structures from these experiments are then taken and applied to process sensor information so as to successfully control a mobile robot.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to fabricate a biomimetic skin for an octopus inspired robot, a new process was developed based on mechanical properties measured from real octopus skin. Various knitted nylon textiles were tested and the one of 10-denier nylon was chosen as reinforcement. A combination of Ecoflex 0030 and 0010 silicone rubbers was used as matrix of the composite to obtain the right stiffness for the skin-analogue system. The open mould fabrication process developed allows air bubble to escape easily and the artificial skin produced was thin and waterproof. Material properties of the biomimetic skin were characterised using static tensile and instrumented scissors cutting tests. The Young’s moduli of the artificial skin are 0.08 MPa and 0.13 MPa in the longitudinal and transverse directions, which are much lower than those of the octopus skin. The strength and fracture toughness of the artificial skin, on the other hand are higher than those of real octopus skins. Conically-shaped skin prototypes to be used to cover the robotic arm unit were manufactured and tested. The biomimetic skin prototype was stiff enough to maintain it conical shape when filled with water. The driving force for elongation was reduced significantly compared with previous prototypes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ground-based Atmospheric Radiation Measurement Program (ARM) and NASA Aerosol Robotic Net- work (AERONET) routinely monitor clouds using zenith ra- diances at visible and near-infrared wavelengths. Using the transmittance calculated from such measurements, we have developed a new retrieval method for cloud effective droplet size and conducted extensive tests for non-precipitating liquid water clouds. The underlying principle is to combine a liquid-water-absorbing wavelength (i.e., 1640 nm) with a non-water-absorbing wavelength for acquiring information on cloud droplet size and optical depth. For simulated stratocumulus clouds with liquid water path less than 300 g m−2 and horizontal resolution of 201 m, the retrieval method underestimates the mean effective radius by 0.8μm, with a root-mean-squared error of 1.7 μm and a relative deviation of 13%. For actual observations with a liquid water path less than 450 g m−2 at the ARM Oklahoma site during 2007– 2008, our 1.5-min-averaged retrievals are generally larger by around 1 μm than those from combined ground-based cloud radar and microwave radiometer at a 5-min temporal resolution. We also compared our retrievals to those from combined shortwave flux and microwave observations for relatively homogeneous clouds, showing that the bias between these two retrieval sets is negligible, but the error of 2.6 μm and the relative deviation of 22 % are larger than those found in our simulation case. Finally, the transmittance-based cloud effective droplet radii agree to better than 11 % with satellite observations and have a negative bias of 1 μm. Overall, the retrieval method provides reasonable cloud effective radius estimates, which can enhance the cloud products of both ARM and AERONET.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Robotic multiwell planar patch-clamp has become common in drug development and safety programs because it enables efficient and systematic testing of compounds against ion channels during voltage-clamp. It has not, however, been adopted significantly in other important areas of ion channel research, where conventional patch-clamp remains the favored method. Here, we show the wider potential of the multiwell approach with the ability for efficient intracellular solution exchange, describing protocols and success rates for recording from a range of native and primary mammalian cells derived from blood vessels, arthritic joints and the immune and central nervous systems. The protocol involves preparing a suspension of single cells to be dispensed robotically into 4-8 microfluidic chambers each containing a glass chip with a small aperture. Under automated control, giga-seals and whole-cell access are achieved followed by preprogrammed routines of voltage paradigms and fast extracellular or intracellular solution exchange. Recording from 48 chambers usually takes 1-6 h depending on the experimental design and yields 16-33 cell recordings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stroke is a medical emergency and can cause a neurological damage, affecting the motor and sensory systems. Harnessing brain plasticity should make it possible to reconstruct the closed loop between the brain and the body, i.e., association of the generation of the motor command with the somatic sensory feedback might enhance motor recovery. In order to aid reconstruction of this loop with a robotic device it is necessary to assist the paretic side of the body at the right moment to achieve simultaneity between motor command and feedback signal to somatic sensory area in brain. To this end, we propose an integrated EEG-driven assistive robotic system for stroke rehabilitation. Depending on the level of motor recovery, it is important to provide adequate stimulation for upper limb motion. Thus, we propose an assist arm incorporating a Magnetic Levitation Joint that can generate a compliant motion due to its levitation and mechanical redundancy. This paper reports on a feasibility study carried out to verify the validity of the robot sensing and on EEG measurements conducted with healthy volunteers while performing a spontaneous arm flexion/extension movement. A characteristic feature was found in the temporal evolution of EEG signal in the single motion prior to executed motion which can aid in coordinating timing of the robotic arm assistance onset.