844 resultados para Reliability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Some controversy remains about the potential applicability of cognitive potentials for evaluating the cerebral activity associated with cognitive capacity. A fundamental requirement is that these neurophysiological parameters show a high level of stability over time. Previous studies have shown that the reliability of diverse parameters of the P3 component (latency and amplitude) ranges between moderate and high. However, few studies have paid attention to the retest reliability of the P3 topography in groups or individuals. Considering that changes in P3 topography have been related to different pathologies and healthy aging, the main objective of this article was to evaluate in a longitudinal study (two sessions) the reliability of P3 topography in a group and at the individual level. RESULTS The correlation between sessions for P3 topography in the grand average of groups was high (r = 0.977, p<0.001). The within-subject correlation values ranged from 0.626 to 0.981 (mean: 0.888). In the between-subjects topography comparisons, the correlation was always lower for comparisons between different subjects than for within-subjects correlations in the first session but not in the second session. CONCLUSIONS The present study shows that P3 topography is highly reliable for group analysis (comprising the same subjects) in different sessions. The results also confirmed that retest reliability for individual P3 maps is suitable for follow-up studies for a particular subject. Moreover, P3 topography appears to be a specific marker considering that the between-subjects correlations were lower than the within-subject correlations. However, P3 topography appears more similar between subjects in the second session, demonstrating that is modulated by experience. Possible clinical applications of all these results are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims and objectives  This study aimed to determine the discriminant validity and the test-retest reliability of a questionnaire testing the impact of evidence-based medicine (EBM) training on doctors' knowledge and skills. Methods  Questionnaires were sent electronically to all doctors working as residents and chief residents in two French speaking hospital networks in Switzerland. Participants completed the questionnaire twice, within a 4-week interval. The discriminant validity was examined in comparing doctors' performance according to their reported EBM previous training. Proportion of agreement between both sessions of the questionnaire, Cohen's kappa and 'uniform kappa' determined its test-retest reliability. Results  The participation rate was 9.8%/7.1% to first/second session. Performance increased according to the level of doctors' previous training in EBM. The observed proportion of agreement between both sessions was over 70% for 14/19 questions, and the 'uniform kappa' was superior to 0.60 for 15/19 questions. Conclusion  The discriminant validity and test-retest reliability of the questionnaire were satisfying. The low participation rate did not prevent the study from achieving its aims.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Given the important role of the shoulder sensorimotor system in shoulder stability, its assessment appears of interest. Force platform monitoring of centre of pressure (CoP) in upper-limb weight-bearing positions is of interest as it allows integration of all aspects of shoulder sensorimotor control. This study aimed to determine the feasibility and reliability of shoulder sensorimotor control assessment by force platform. Forty-five healthy subjects performed two sessions of CoP measurement using Win-Posturo(®) Medicapteurs force platform in an upper-limb weight-bearing position with the lower limbs resting on a table to either the anterior superior iliac spines (P1) or upper patellar poles (P2). Four different conditions were tested in each position in random order: eyes open or eyes closed with trunk supported by both hands and eyes open with trunk supported on the dominant or non-dominant side. P1 reliability values were globally moderate to high for CoP length, CoP velocity and CoP standard deviation (SD), standard error of measurement ranged from 6·0% to 26·5%, except for CoP area. P2 reliability values were globally low and not clinically acceptable. Our results suggest that shoulder sensorimotor control assessment by force platform is feasible and has good reliability in upper-limb weight-bearing positions when the lower limbs are resting on a table to the anterior superior iliac spines. CoP length, CoP velocity and CoP SD velocity appear to be the most reliable variables.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 58 newborn infants a new iridium oxide sensor was evaluated for transcutaneous carbon dioxide (tcPCO2) monitoring at 42 degrees C with a prolonged fixation time of 24 hours. The correlation of tcPCO2 (y; mm Hg) v PaCO2 (x; mm Hg) for 586 paired values was: y = 4.6 + 1.45x; r = .89; syx = 6.1 mm Hg. The correlation was not influenced by the duration of fixation. The transcutaneous sensor detected hypocapnia (PaCO2 less than 35 mm Hg) in 74% and hypercapnia (PCO2 greater than 45 mm Hg) in 74% of all cases. After 24 hours, calibration shifts were less than 4 mm Hg in 90% of the measuring periods. In 86% of the infants, no skin changes were observed; in 12% of infants, there were transitional skin erythemas and in 2% a blister which disappeared without scarring. In newborn infants with normal BPs, continuous tcPCO2 monitoring at 42 degrees C can be extended for as many as 24 hours without loss of reliability or increased risk for skin burns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this paper is to describe the development and to test the reliability of a new method called INTERMED, for health service needs assessment. The INTERMED integrates the biopsychosocial aspects of disease and the relationship between patient and health care system in a comprehensive scheme and reflects an operationalized conceptual approach to case mix or case complexity. The method is developed to enhance interdisciplinary communication between (para-) medical specialists and to provide a method to describe case complexity for clinical, scientific, and educational purposes. First, a feasibility study (N = 21 patients) was conducted which included double scoring and discussion of the results. This led to a version of the instrument on which two interrater reliability studies were performed. In study 1, the INTERMED was double scored for 14 patients admitted to an internal ward by a psychiatrist and an internist on the basis of a joint interview conducted by both. In study 2, on the basis of medical charts, two clinicians separately double scored the INTERMED in 16 patients referred to the outpatient psychiatric consultation service. Averaged over both studies, in 94.2% of all ratings there was no important difference between the raters (more than 1 point difference). As a research interview, it takes about 20 minutes; as part of the whole process of history taking it takes about 15 minutes. In both studies, improvements were suggested by the results. Analyses of study 1 revealed that on most items there was considerable agreement; some items were improved. Also, the reference point for the prognoses was changed so that it reflected both short- and long-term prognoses. Analyses of study 2 showed that in this setting, less agreement between the raters was obtained due to the fact that the raters were less experienced and the scoring procedure was more susceptible to differences. Some improvements--mainly of the anchor points--were specified which may further enhance interrater reliability. The INTERMED proves to be a reliable method for classifying patients' care needs, especially when used by experienced raters scoring by patient interview. It can be a useful tool in assessing patients' care needs, as well as the level of needed adjustment between general and mental health service delivery. The INTERMED is easily applicable in the clinical setting at low time-costs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The Foot and Ankle Ability Measure (FAAM) is a self reported questionnaire for patients with foot and ankle disorders available in English, German, and Persian. This study plans to translate the FAAM from English to French (FAAM-F) and assess the validity and reliability of this new version.METHODS: The FAAM-F Activities of Daily Living (ADL) and sports subscales were completed by 105 French-speaking patients (average age 50.5 years) presenting various chronic foot and ankle disorders. Convergent and divergent validity was assessed by Pearson's correlation coefficients between the FAAM-F subscales and the SF-36 scales: Physical Functioning (PF), Physical Component Summary (PCS), Mental Health (MH) and Mental Component Summary (MCS). Internal consistency was calculated by Cronbach's Alpha (CA). To assess test re-test reliability, 22 patients filled out the questionnaire a second time to estimate minimal detectable changes (MDC) and intraclass correlation coefficients (ICC).RESULTS: Correlations for FAAM-F ADL subscale were 0.85 with PF, 0.81 with PCS, 0.26 with MH, 0.37 with MCS. Correlations for FAAM-F Sports subscale were 0.72 with PF, 0.72 with PCS, 0.21 with MH, 0.29 with MCS. CA estimates were 0.97 for both subscales. Respectively for the ADL and Sports subscales, ICC were 0.97 and 0.94, errors for a single measure were 8 and 10 points at 95% confidence and the MDC values at 95% confidence were 7 and 18 points.CONCLUSION: The FAAM-F is valid and reliable for the self-assessment of physical function in French-speaking patients with a wide range of chronic foot and ankle disorders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The COSMIN checklist is a tool for evaluating the methodological quality of studies on measurement properties of health-related patient-reported outcomes. The aim of this study is to determine the inter-rater agreement and reliability of each item score of the COSMIN checklist (n = 114). Methods: 75 articles evaluating measurement properties were randomly selected from the bibliographic database compiled by the Patient-Reported Outcome Measurement Group, Oxford, UK. Raters were asked to assess the methodological quality of three articles, using the COSMIN checklist. In a one-way design, percentage agreement and intraclass kappa coefficients or quadratic-weighted kappa coefficients were calculated for each item. Results: 88 raters participated. Of the 75 selected articles, 26 articles were rated by four to six participants, and 49 by two or three participants. Overall, percentage agreement was appropriate (68% was above 80% agreement), and the kappa coefficients for the COSMIN items were low (61% was below 0.40, 6% was above 0.75). Reasons for low inter-rater agreement were need for subjective judgement, and accustom to different standards, terminology and definitions.Conclusions: Results indicated that raters often choose the same response option, but that it is difficult on item level to distinguish between articles. When using the COSMIN checklist in a systematic review, we recommend getting some training and experience, completing it by two independent raters, and reaching consensus on one final rating. Instructions for using the checklist are improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Communication is an indispensable component of animal societies, yet many open questions remain regarding the factors affecting the evolution and reliability of signalling systems. A potentially important factor is the level of genetic relatedness between signallers and receivers. To quantitatively explore the role of relatedness in the evolution of reliable signals, we conducted artificial evolution over 500 generations in a system of foraging robots that can emit and perceive light signals. By devising a quantitative measure of signal reliability, and comparing independently evolving populations differing in within-group relatedness, we show a strong positive correlation between relatedness and reliability. Unrelated robots produced unreliable signals, whereas highly related robots produced signals that reliably indicated the location of the food source and thereby increased performance. Comparisons across populations also revealed that the frequency for signal production-which is often used as a proxy of signal reliability in empirical studies on animal communication-is a poor predictor of signal reliability and, accordingly, is not consistently correlated with group performance. This has important implications for our understanding of signal evolution and the empirical tools that are used to investigate communication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To conduct a cross-cultural adaptation of the Core Outcome Measures Index (COMI) into French according to established guidelines. METHODS: Seventy outpatients with chronic low back pain were recruited from six spine centres in Switzerland and France. They completed the newly translated COMI, and the Roland Morris disability (RMQ), Dallas Pain (DPQ), adjectival pain rating scale, WHO Quality of Life, and EuroQoL-5D questionnaires. After ~14 days RMQ and COMI were completed again to assess reproducibility; a transition question (7-point Likert scale; "very much worse" through "no change" to "very much better") indicated any change in status since the first questionnaire. RESULTS: COMI whole scores displayed no floor effects and just 1.5% ceiling effects. The scores for the individual COMI items correlated with their corresponding full-length reference questionnaire with varying strengths of correlation (0.33-0.84, P < 0.05). COMI whole scores showed a very good correlation with the "multidimensional" DPQ global score (Rho = 0.71). 55 patients (79%) returned a second questionnaire with no/minimal change in their back status. The reproducibility of individual COMI 5-point items was good, with test-retest differences within one grade ranging from 89% for 'social/work disability' to 98% for 'symptom-specific well-being'. The intraclass correlation coefficient for the COMI whole score was 0.85 (95% CI 0.76-0.91). CONCLUSIONS: In conclusion, the French version of this short, multidimensional questionnaire showed good psychometric properties, comparable to those reported for German and Spanish versions. The French COMI represents a valuable tool for future multicentre clinical studies and surgical registries (e.g. SSE Spine Tango) in French-speaking countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When facing age-related cerebral decline, older adults are unequally affected by cognitive impairment without us knowing why. To explore underlying mechanisms and find possible solutions to maintain life-space mobility, there is a need for a standardized behavioral test that relates to behaviors in natural environments. The aim of the project described in this paper was therefore to provide a free, reliable, transparent, computer-based instrument capable of detecting age-related changes on visual processing and cortical functions for the purposes of research into human behavior in computational transportation science. After obtaining content validity, exploring psychometric properties of the developed tasks, we derived (Study 1) the scoring method for measuring cerebral decline on 106 older drivers aged ≥70 years attending a driving refresher course organized by the Swiss Automobile Association to test the instrument's validity against on-road driving performance (106 older drivers). We then validated the derived method on a new sample of 182 drivers (Study 2). We then measured the instrument's reliability having 17 healthy, young volunteers repeat all tests included in the instrument five times (Study 3) and explored the instrument's psychophysical underlying functions on 47 older drivers (Study 4). Finally, we tested the instrument's responsiveness to alcohol and effects on performance on a driving simulator in a randomized, double-blinded, placebo, crossover, dose-response, validation trial including 20 healthy, young volunteers (Study 5). The developed instrument revealed good psychometric properties related to processing speed. It was reliable (ICC = 0.853) and showed reasonable association to driving performance (R (2) = 0.053), and responded to blood alcohol concentrations of 0.5 g/L (p = 0.008). Our results suggest that MedDrive is capable of detecting age-related changes that affect processing speed. These changes nevertheless do not necessarily affect driving behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study had as its objective to analyze the intraclass reliability of the Alberta Infant Motor Scale (AIMS), in the Brazilian version, in preterm and term infants. It was a methodological study, conducted from November 2009 to April 2010, with 50 children receiving care in two public institutions in Fortaleza, Ceará, Brazil. Children were grouped according to gestational age as preterm and term, and evaluated by three evaluators in the communication laboratory of a public institution or at home. The intraclass correlation indices for the categories prone, supine, sitting and standing ranged from 0.553 to 0.952; most remained above 0.800, except for the standing category of the third evaluator, in which the index was 0.553. As for the total score and percentile, rates ranged from 0.843 to 0.954. The scale proved to be a reliable instrument for assessing gross motor performance of Brazilian children, particularly in Ceará, regardless of gestational age at birth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using a sample of patients with coronary artery disease, this methodological study aimed to conduct a cross-cultural adaptation and validation of a questionnaire on knowledge of cardiovascular risk factors (Q-FARCS), lifestyle changes, and treatment adherence for use in Brazil. The questionnaire has three scales: general knowledge of risk factors (RFs); specific knowledge of these RFs; and lifestyle changes achieved. Cross-cultural adaptation included translation, synthesis, back-translation, expert committee review, and pretesting. Face and content validity, reliability, and construct validity were measured. Cronbach’s alpha for the total sample (n = 240) was 0.75. Assessment of psychometric properties revealed adequate face and content validity, and the construct revealed seven components. It was concluded that the Brazilian version of Q-FARCS had adequate reliability and validity for the assessment of knowledge of cardiovascular RFs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the acceptability, ceiling/floor effects, and the reliability of the instrument for measuring the Impact of the Disease on the Daily Life of Patients with Valvular Disease (IDCV) when applied to 135 patients with heart failure (HF). Acceptability was evaluated by the percentage of unanswered items and by the proportion of patients who responded to all items; the ceiling/floor effects by the percentage of patients who scored in the top of 10% best and worst results of the scale, respectively. Reliability was estimated by internal consistency (Cronbach's alpha coefficient) and stability of the measure (intraclass correlation coefficient - ICC). All patients responded to all items. Ceiling/floor effects evidenced were of moderate magnitude. The Cronbach's alpha was satisfactory for the majority of the domains and ICC> 0.90 in all the domains. The IDCV proved to be an easy to understand questionnaire, with evidence of reliability in patients with HF.