804 resultados para Refractive Errors
Resumo:
Wet-milling protocol was employed to produce pressed powder tablets with excellent cohesion and homogeneity suitable for laser ablation (LA) analysis of volatile and refractive elements in sediment. The influence of sample preparation on analytical performance was also investigated, including sample homogeneity, accuracy and limit of detection. Milling in volatile solvent for 40 min ensured sample is well mixed and could reasonably recover both volatile (Hg) and refractive (Zr) elements. With the exception of Cr (−52%) and Nb (+26%) major, minor and trace elements in STSD-1 and MESS-3 could be analysed within ±20% of the certified values. Comparison of the method with total digestion method using HF was tested by analysing 10 different sediment samples. The laser method recovers significantly higher amounts of analytes such as Ag, Cd, Sn and Sn than the total digestion method making it a more robust method for elements across the periodic table. LA-ICP-MS also eliminates the interferences from chemical reagents as well as the health and safety risks associated with digestion processes. Therefore, it can be considered as an enhanced method for the analysis of heterogeneous matrices such as river sediments.
Resumo:
A 'pseudo-Bayesian' interpretation of standard errors yields a natural induced smoothing of statistical estimating functions. When applied to rank estimation, the lack of smoothness which prevents standard error estimation is remedied. Efficiency and robustness are preserved, while the smoothed estimation has excellent computational properties. In particular, convergence of the iterative equation for standard error is fast, and standard error calculation becomes asymptotically a one-step procedure. This property also extends to covariance matrix calculation for rank estimates in multi-parameter problems. Examples, and some simple explanations, are given.
Resumo:
Purpose This study evaluated the impact of patient set-up errors on the probability of pulmonary and cardiac complications in the irradiation of left-sided breast cancer. Methods and Materials Using the CMS XiO Version 4.6 (CMS Inc., St Louis, MO) radiotherapy planning system's NTCP algorithm and the Lyman -Kutcher-Burman (LKB) model, we calculated the DVH indices for the ipsilateral lung and heart and the resultant normal tissue complication probabilities (NTCP) for radiation-induced pneumonitis and excess cardiac mortality in 12 left-sided breast cancer patients. Results Isocenter shifts in the posterior direction had the greatest effect on the lung V20, heart V25, mean and maximum doses to the lung and the heart. Dose volume histograms (DVH) results show that the ipsilateral lung V20 tolerance was exceeded in 58% of the patients after 1cm posterior shifts. Similarly, the heart V25 tolerance was exceeded after 1cm antero-posterior and left-right isocentric shifts in 70% of the patients. The baseline NTCPs for radiation-induced pneumonitis ranged from 0.73% - 3.4% with a mean value of 1.7%. The maximum reported NTCP for radiation-induced pneumonitis was 5.8% (mean 2.6%) after 1cm posterior isocentric shift. The NTCP for excess cardiac mortality were 0 % in 100% of the patients (n=12) before and after setup error simulations. Conclusions Set-up errors in left sided breast cancer patients have a statistically significant impact on the Lung NTCPs and DVH indices. However, with a central lung distance of 3cm or less (CLD <3cm), and a maximum heart distance of 1.5cm or less (MHD<1.5cm), the treatment plans could tolerate set-up errors of up to 1cm without any change in the NTCP to the heart.
Resumo:
Prequantization has been forwarded as a means to improve the performance of double phase holograms (DPHs). We show here that any improvement (even under the best of conditions) is not large enough to help the DPH to compete favourably with other holograms.
Resumo:
A 59-year-old man was mistakenly prescribed Slow-Na instead of Slow-K due to incorrect selection from a drop-down list in the prescribing software. This error was identified by a pharmacist during a home medicine review (HMR) before the patient began taking the supplement. The reported error emphasizes the need for vigilance due to the emergence of novel look-alike, sound-alike (LASA) drug pairings. This case highlights the important role of pharmacists in medication safety.
Resumo:
An empirical relation for temperature–independent molar polarization is suggested. When this relation was used, the thermal expansivity was estimated correctly from refractive index data.
Resumo:
Well into his ophthalmic journey of retinopexy, cryopexy, vitrectomy and IOL surgery, Professor Nathan Efron's pauses to undertake a forensic examination of his clinical records to identify the source of his refractive surprise.
Resumo:
Purpose: To compare lens dimensions and refractive index distributions in type 1 diabetes and age-matched control groups. Methods: There were 17 participants with type 1 diabetes, consisting of two subgroups (7 young [23 ± 4 years] and 10 older [54 ± 4 years] participants), with 23 controls (13 young, 24 ± 4 years; 10 older, 55 ± 4 years). For each participant, one eye was tested with relaxed accommodation. A 3T clinical magnetic resonance imaging scanner was used to image the eye, employing a multiple spin echo (MSE) sequence to determine lens dimensions and refractive index profiles along the equatorial and axial directions. Results: The diabetes group had significantly smaller lens equatorial diameters and larger lens axial thicknesses than the control group (diameter mean ± 95% confidence interval [CI]: diabetes group 8.65 ± 0.26 mm, control group 9.42 ± 0.18 mm; axial thickness: diabetes group 4.33 ± 0.30 mm, control group 3.80 ± 0.14 mm). These differences were also significant within each age group. The older group had significantly greater axial thickness than the young group (older group 4.35 ± 0.26 mm, young group 3.70 ± 0.25 mm). Center refractive indices of diabetes and control groups were not significantly different. There were some statistically significant differences between the refractive index fitting parameters of young and older groups, but not between diabetes and control groups of the same age. Conclusions: Smaller lens diameters occurred in the diabetes groups than in the age-matched control groups. Differences in refractive index distribution between persons with and without diabetes are too small to have important effects on instruments measuring axial thickness.
Resumo:
Non-invasive measurements of the age dependence of refractive index distribution in human eye lenses in vitro using a novel X-ray Talbot Interferometry method. In their paper, the authors make frequent reference to our own work in which we employed magnetic resonance imaging (MRI) to make similar non-invasive measurements of the refractive index distribution in the human eye lens [2, 3]. Prior to the current work, ours was the only method for making such measurements both non-invasively and without prior assumptions about the shape of the refractive index distribution. For this reason, the latest work is to be welcomed. However at several points in the paper, Pierscionek et al. [1] make statements about our technique which are factually incorrect...
Resumo:
A simple moire method for the direct measurement of refractive indices is presented. The change of magnification and/or distortion of the image of a linear grating when viewed through a refractive index field is amplified by means of moire fringes and is measured directly. Relations between the index of refraction and fringe spacing are derived and have been verified experimentally.
Resumo:
Conventional methods for determining the refractive index demand specimens of optical quality, the preparation of which is often very difficult. An indirect determination by matching the refractive indices of specimen and immersion liquid is a practical alternative for photoelastic specimen of nonoptical quality. An experimental arrangement used for this technique and observations made while matching the refractive indices of three different specimens are presented.
Resumo:
This thesis studies empirically whether measurement errors in aggregate production statistics affect sentiment and future output. Initial announcements of aggregate production are subject to measurement error, because many of the data required to compile the statistics are produced with a lag. This measurement error can be gauged as the difference between the latest revised statistic and its initial announcement. Assuming aggregate production statistics help forecast future aggregate production, these measurement errors are expected to affect macroeconomic forecasts. Assuming agents’ macroeconomic forecasts affect their production choices, these measurement errors should affect future output through sentiment. This thesis is primarily empirical, so the theoretical basis, strategic complementarity, is discussed quite briefly. However, it is a model in which higher aggregate production increases each agent’s incentive to produce. In this circumstance a statistical announcement which suggests aggregate production is high would increase each agent’s incentive to produce, thus resulting in higher aggregate production. In this way the existence of strategic complementarity provides the theoretical basis for output fluctuations caused by measurement mistakes in aggregate production statistics. Previous empirical studies suggest that measurement errors in gross national product affect future aggregate production in the United States. Additionally it has been demonstrated that measurement errors in the Index of Leading Indicators affect forecasts by professional economists as well as future industrial production in the United States. This thesis aims to verify the applicability of these findings to other countries, as well as study the link between measurement errors in gross domestic product and sentiment. This thesis explores the relationship between measurement errors in gross domestic production and sentiment and future output. Professional forecasts and consumer sentiment in the United States and Finland, as well as producer sentiment in Finland, are used as the measures of sentiment. Using statistical techniques it is found that measurement errors in gross domestic product affect forecasts and producer sentiment. The effect on consumer sentiment is ambiguous. The relationship between measurement errors and future output is explored using data from Finland, United States, United Kingdom, New Zealand and Sweden. It is found that measurement errors have affected aggregate production or investment in Finland, United States, United Kingdom and Sweden. Specifically, it was found that overly optimistic statistics announcements are associated with higher output and vice versa.
Resumo:
Background Medication safety is a pressing concern for residential aged care facilities (RACFs). Retrospective studies in RACF settings identify inadequate communication between RACFs, doctors, hospitals and community pharmacies as the major cause of medication errors. Existing literature offers limited insight about the gaps in the existing information exchange process that may lead to medication errors. The aim of this research was to explicate the cognitive distribution that underlies RACF medication ordering and delivery to identify gaps in medication-related information exchange which lead to medication errors in RACFs. Methods The study was undertaken in three RACFs in Sydney, Australia. Data were generated through ethnographic field work over a period of five months (May–September 2011). Triangulated analysis of data primarily focused on examining the transformation and exchange of information between different media across the process. Results The findings of this study highlight the extensive scope and intense nature of information exchange in RACF medication ordering and delivery. Rather than attributing error to individual care providers, the explication of distributed cognition processes enabled the identification of gaps in three information exchange dimensions which potentially contribute to the occurrence of medication errors namely: (1) design of medication charts which complicates order processing and record keeping (2) lack of coordination mechanisms between participants which results in misalignment of local practices (3) reliance on restricted communication bandwidth channels mainly telephone and fax which complicates the information processing requirements. The study demonstrates how the identification of these gaps enhances understanding of medication errors in RACFs. Conclusions Application of the theoretical lens of distributed cognition can assist in enhancing our understanding of medication errors in RACFs through identification of gaps in information exchange. Understanding the dynamics of the cognitive process can inform the design of interventions to manage errors and improve residents’ safety.
Resumo:
In anisometropia, the two eyes have unequal refractive power. Anisometropia is a risk factor for amblyopia. The visual deficiencies are thought to be irreversible after the first decade of life. There is, however, accumulating evidence that neural plasticity exists also in adult brains. The aim of this study was to investigate functional outcome of excimer laser refractive surgery in adult anisometropic and visually impaired patients. Additional goal was to examine changes in the primary visual cortex (V1) using multifocal functional magnetic resonance imaging (mffMRI) after laser refractive surgery. Study I comprised of 57 anisometropic patients (anisometropia of ≥3.25 diopters) and 174 isometropic myopic subjects formed the control group. A significant improvement in best-spectacle-corrected visual acuity (BSCVA) among myopic control subjects was evident 3 months postoperatively. The improvement in BSCVA was significantly slower for anisometropic patients and the improvement appeared to persist to the end of the follow-up (24 months). In study II we found that refractive surgery may be also successfully used for iathrogenic anisometropia. In Study III we evaluated mildly visually impaired adult patients after refractive surgery. There was a statistically significant improvement in BSCVA among visually impaired patients and the difference in the mean BSCVA between visually impaired patients and isometropic myopic control subjects diminished during follow-up. Study IV was a prospective follow-up trial examining the changes in the primary visual cortex after refractive surgery. Two anisometropic patients and two isometropic myopic patients were examined with a 61-region mffMRI before refractive surgery and at three, six, nine and twelve months postoperatively. In this study, a dramatic decrease in the number of active voxels in the fovea was found among anisometropic patients. The results presented in this thesis revealed that refractive surgery may be successfully used for the treatment of anisometropic adults with both congenital and iatrogenic anisometropia and for mildly visually impaired adults. The findings in conclusion strengthen our hypothesis of plastic changes in the visual cortex of adult anisometropic and mildly visually impaired patients after refractive surgery.