976 resultados para RADIATIVE CORRECTIONS
Resumo:
The radiative processes associated with fluorophores and other radiating systems can be profoundly modified by their interaction with nanoplasmonic structures. Extreme electromagnetic environments can be created in plasmonic nanostructures or nanocavities, such as within the nanoscale gap region between two plasmonic nanoparticles, where the illuminating optical fields and the density of radiating modes are dramatically enhanced relative to vacuum. Unraveling the various mechanisms present in such coupled systems, and their impact on spontaneous emission and other radiative phenomena, however, requires a suitably reliable and precise means of tuning the plasmon resonance of the nanostructure while simultaneously preserving the electromagnetic characteristics of the enhancement region. Here, we achieve this control using a plasmonic platform consisting of colloidally synthesized nanocubes electromagnetically coupled to a metallic film. Each nanocube resembles a nanoscale patch antenna (or nanopatch) whose plasmon resonance can be changed independent of its local field enhancement. By varying the size of the nanopatch, we tune the plasmonic resonance by ∼ 200 nm, encompassing the excitation, absorption, and emission spectra corresponding to Cy5 fluorophores embedded within the gap region between nanopatch and film. By sweeping the plasmon resonance but keeping the field enhancements roughly fixed, we demonstrate fluorescence enhancements exceeding a factor of 30,000 with detector-limited enhancements of the spontaneous emission rate by a factor of 74. The experiments are supported by finite-element simulations that reveal design rules for optimized fluorescence enhancement or large Purcell factors.
Resumo:
The equilibrium structure of acetylene (also named ethyne) has been reinvestigated to resolve the small discrepancies noted between different determinations. The size of the system as well as the large amount of available experimental data provides the quite unique opportunity to check the magnitude and relevance of various contributions to equilibrium structure as well as to verify the accuracy of experimental results. With respect to pure theoretical investigation, quantum-chemical calculations at the coupled-cluster level have been employed together with extrapolation to the basis set limit, consideration of higher excitations in the cluster operator, inclusion of core correlation effects as well as relativistic and diagonal Born-Oppenheimer corrections. In particular, it is found that the extrapolation to the complete basis set limit, the inclusion of higher excitations in the electronic-correlation treatment and the relativistic corrections are of the same order of magnitude. It also appears that a basis set as large as a core-valence quintuple-zeta set is required for accurately accounting for the inner-shell correlation contribution. From a pure experimental point of view, the equilibrium structure has been determined using very accurate rotational constants recently obtained by a global analysis (that is to say that all non-negligible interactions are explicitely included in the Hamiltonian matrix) of rovibrational spectra. Finally, a semi-experimental equilibrium structure (where the equilibrium rotational constants are obtained from the experimental ground state rotational constants and computed rovibrational corrections) has been obtained from the available experimental ground-state rotational constants for ten isotopic species corrected for computed vibrational corrections. Such a determination led to the revision of the ground-state rotational constants of two isotopologues, thus showing that structural determination is a good method to identify errors in experimental rotational constants. The three structures are found in a very good agreement, and our recommended values are rCC 120.2958(7) pm and rCH 106.164(1) pm. © 2011 American Institute of Physics.
Resumo:
The intensity and location of Sun glint in two Medium Resolution Imaging Spectrometer (MERIS) images was modeled using a radiative transfer model that includes elevation features as well as the slope of the sea surface. The results are compared to estimates made using glint flagging and correction approaches used within standard atmospheric correction processing code. The model estimate gives a glint pattern with a similar width but lower peak level than any current method, or than that estimated by a radiative transfer model with surfaces that include slope but not height. The MERIS third reprocessing recently adopted a new slope statistics model for Sun glint correction; the results show that this model is an outlier with respect to both the elevation model and other slope statistics models and we recommend that its adoption should be reviewed.
Resumo:
We present a technique for measuring the radiative lifetimes of metastable states of negative ions that involves the use of a heavy-ion storage ring. The method has been applied to investigate the radiative decay of the np3 2P1/2 levels of Te–(n=5) and Se–(n=4) and the 3p3 2D state of Si– for which the J=3/2 and 5/2 levels were unresolved. All of these states are metastable and decay primarily by emission of E2 and M1 radiation. Multi Configuration Dirac-Hartree-Fock calculations of rates for the transitions in Te– and Se– yielded lifetimes of 0.45 s and 4.7 s, respectively. The measured values agree well with these predicted values. In the case of the 2D state of Si–, however, our measurement was only able to set a lower limit on the lifetime. The upper limit of the lifetime that can be measured with our apparatus is set by how long the ions can be stored in the ring, a limit determined by the rate of collisional detachment. Our lower limit of 1 min for the lifetime of the 2D state is consistent with both the calculated lifetimes of 162 s for the 2D3/2 level and 27.3 h for the 2D5/2 level reported by O'Malley and Beck and 14.5 h and 12.5 h, respectively, from our Breit-Pauli calculations.
Resumo:
An analysis of radiative transfer effects present in the Fe XV ion stage of solar and stellar coronal plasmas provides a general explanation of line radiation intensity enhancement above the optically thin limit. Full linearization radiation transfer is compared with the escape factor method and found to be in good agreement at the lower column densities. An angular study of the enhancement shows that symmetry factors are of great importance. This gives a possible reason for the indeterminate status of opacity in relation to coronal lines of distant stellar sources, where only emission integrated across the whole surface is detected.
Resumo:
Radiative rates for electric dipole (E I), electric quadrupole (E2), magnetic dipole (M1), and magnetic quadrupole (M2) transitions among the lowest 60 fine-structure levels of the (1s(2)) 2S(2)2p(5), 2s2p(6), and 2S(2)2p(4)3l configurations of F-like Mo XXXIV have been calculated using the fully relativistic GRASP code. Additionally, collision strengths for transitions among these levels have been computed over a wide energy range below 3200Ry, using the Dirac Atomic R-matrix Code. Resonances have been resolved in a fine energy mesh in order to calculate the effective collision strengths. Results for radiative rates and excitation rates are presented for all transitions, and for collision strengths for transitions from the lowest three levels to the higher lying levels. The accuracy of the present data is assessed to be similar to 20%.
Resumo:
Energies of the 54 levels belonging to the (1s(2)2s(2)2p(6)) 3s(2)3p(5), 3s3p(6), 3s(2)3p(4)3d and 3s3p(5)3d configurations of Fe X have been calculated using the GRASP code of Dyall et al. (1989). Additionally, radiative rates, oscillator strengths, and line strengths are calculated for all electric dipole (E1), magnetic dipole (M1), electric quadrupole (E2), and magnetic quadrupole (M2) transitions among these levels. Comparisons are made with results available in the literature, and the accuracy of the data is assessed. Our energy levels are estimated to be accurate to better than 3%, whereas results for other parameters are probably accurate to better than 20%. Additionally, the agreement between measured and calculated lifetimes is better than 10%.
Resumo:
Energies of the lowest 157 levels belonging to the (1s(2)) 2s(2)2p(6), 2s(2)p(5)3l, 2s(2)2p(5)4l, 2s(2)2p(5)4l, 2s2p(5)5l, 2s2p(6)4l and 2s2p(6)5l configurations of Fe XVII have been calculated using the GRASP code of Dyall et al. (1989). Additionally, radiative rates, oscillator strengths, and line strengths are calculated for all electric dipole (E I), magnetic dipole (M I), electric quadrupole (E2), and magnetic quadrupole (M2) transitions among these levels. Comparisons are made with the results already available in the literature, and the accuracy of the data is assessed. Our energy levels are expected to be accurate to better than M whereas results for other parameters are probably accurate to better than 20%.
Resumo:
Energy levels and radiative rates for transitions among 107 fine-structure levels belonging to the (1s(2)2S(2)p(6)) 3S(2)3p(6)3d(10), 3S(2)3p(6)3d(9)4e. 3S(2)3p(5)3d(10)4e. and 3s3p(6)3d(10)4e configurations of Ni-like Gd XXXVII have been calculated using the fully relativistic GRASP code. Radiative rates and oscillator strengths are tabulated for all allowed transitions among these levels. Additionally. collision strengths for transitions among the lowest 59 levels have been computed using the Dirac Atomic R-matrix Code. Resonances in the threshold region have been delineated, but results for collision strengths are tabulated only at energies above thresholds in the range 120
Resumo:
Energy levels and radiative rates for fine-structure transitions in nickel ions (Ni XIII-XVI) have been calculated using the GRASP code. Configuration interaction and relativistic effects have been included, and comparisons are made with available data. Energy levels and radiative rates are tabulated for transitions among the 48, 43, 32, and 84 levels of Ni XIII, Ni XIV, Ni XV, and Ni XVI, respectively. The energy levels are assessed to be accurate to better than 5% for a majority of levels, while oscillator strengths for all strong transitions are accurate to better than 20%. (C) 2003 Published by Elsevier Inc.