923 resultados para Prior, Matthew
Resumo:
BACKGROUND AND AIM OF THE STUDY: Percutaneous coronary interventions (PCI) are frequently performed before coronary artery bypass graft (CABG) surgery. This study sought to evaluate postoperative outcomes, and incidence of recurrent target ischemia in vessels with prior PCI in patients who had PCI prior to CABG compared to only CABG patients. METHODS: A review included CABG patients operated from 2000 to 2012. PCI prior to CABG patients were compared with patients having had CABG on native coronary arteries. Demographic and risk factors, including hospital morbidity, mortality, and recurrent target vessel ischemia at follow-up (FU), were compared. Major end-points were statistical differences of postoperative morbidity and reintervention rates due to symptomatic graft failure or target vessel ischemia during FU. RESULTS: Twenty-four percent of 1669 isolated CABG patients had PCI prior to CABG, with an increasing percentage during recent years. Demographics, risk factors, comorbidities and mortality rates were similar. Incidence of postoperative hemorrhage (OR 1.9; 95% CI 1.1-3.2; p = 0.02), perioperative myocardial infarction rate (p = 0.02), neurological deficits (OR 3.5; 95% CI 1.2-9.7; p = 0.02) and re-intervention rate for symptomatic graft or target vessel occlusion were higher in pretreated patients (OR 1.8; 95% CI 1.1-3.0; p = 0.01). CONCLUSIONS: PCI prior to CABG increases the risk for postoperative morbidity. Increased postoperative hemorrhage could be attributed to ongoing double anti-platelet therapy. doi: 10.1111/jocs.12514 (J Card Surg 2015;30:313-318).
Resumo:
It is generally assumed that steroid hormones are carried in the blood free and/or bound to plasma proteins. We investigated whether blood cells were also able to bind/carry sex-related hormones: estrone, estradiol, DHEA and testosterone. Wistar male and female rats were fed a cafeteria diet for 30 days, which induced overweight. The rats were fed the standard rat diet for 15 additional days to minimize the immediate effects of excess ingested energy. Controls were always kept on standard diet. After the rats were killed, their blood was used for 1) measuring plasma hormone levels, 2) determining the binding of labeled hormones to washed red blood cells (RBC), 3) incubating whole blood with labeled hormones and determining the distribution of label between plasma and packed cells, discounting the trapped plasma volume, 4) determining free plasma hormone using labeled hormones, both through membrane ultrafiltration and dextrancharcoal removal. The results were computed individually for each rat. Cells retained up to 32% estrone, and down to 10% of testosterone, with marked differences due to sex and diet (the latter only for estrogens, not for DHEA and testosterone). Sex and diet also affected the concentrations of all hormones, with no significant diet effects for estradiol and DHEA, but with considerable interaction between both factors. Binding to RBC was non-specific for all hormones. Estrogen distribution in plasma compartments was affected by sex and diet. In conclusion: a) there is a large non-specific RBC-carried compartment for estrone, estradiol, DHEA and testosterone deeply affected by sex; b) Prior exposure to a cafeteria (hyperlipidic) diet induced hormone distribution changes, affected by sex, which hint at sex-related structural differences in RBC membranes; c) We postulate that the RBC compartment may contribute to maintain free (i.e., fully active) sex hormone levels in a way similar to plasma proteins non-specific binding.
Resumo:
BACKGROUND: The efficacy of first-generation protease inhibitor based triple-therapy against hepatitis C virus (HCV) infection is limited in HIV/HCV-coinfected patients with advanced liver fibrosis and non-response to previous peginterferon-ribavirin. These patients have a low chance of achieving a sustained virologic response (SVR) using first generation triple-therapy, with a success rate of only 20%. We investigated the efficacy and safety of lead-in therapy with intravenous silibinin followed by triple-therapy in this difficult-to-treat patient group. METHODOLOGY: Inclusion criteria were HIV/HCV coinfection with advanced liver fibrosis and documented previous treatment failure on peginterferon-ribavirin. The intervention was a lead-in therapy with intravenous silibinin 20 mg/kg/day for 14 days, followed by triple-therapy (peginterferon-ribavirin and telaprevir) for 12 weeks, and peginterferon-ribavirin alone for 36 weeks. Outcome measurements were HCV-RNA after silibinin lead-in and during triple-therapy, SVR data at week 12, and safety and tolerability of silibinin. RESULTS: We examined sixteen HIV/HCV-coinfected patients with previous peginterferon-ribavirin failure, of whom 14 had a fibrosis grade METAVIR ≥F3. All were on successful antiretroviral therapy. Median (IQR) HCV-RNA decline after silibinin therapy was 2.65 (2.1-2.8) log10 copies/mL. Fifteen of sixteen patients (94%) had undetectable HCV RNA at weeks 4 and 12, eleven patients (69%) showed end-of-treatment response (i.e., undetectable HCV-RNA at week 48), and ten patients (63%) reached SVR at week 12 (SVR 12). Six of the sixteen patients (37%) did not reach SVR 12: One patient had rapid virologic response (RVR) (i.e., undetectable HCV-RNA at week 4) but stopped treatment at week 8 due to major depression. Five patients had RVR, but experienced viral breakthroughs at week 21, 22, 25, or 32, or a relapse at week 52. The HIV RNA remained below the limit of detection in all patients during the complete treatment period. No serious adverse events and no significant drug-drug interactions were associated with silibinin. CONCLUSION: A lead-in with silibinin before triple-therapy was safe and highly effective in difficult-to-treat HIV/HCV coinfected patients, with a pronounced HCV-RNA decline during the lead-in phase, which translates into 63% SVR. An add-on of intravenous silibinin to standard of care HCV treatment is worth further exploration in selected difficult-to-treat patients. TRIAL REGISTRATION: ClinicalTrials.gov NCT01816490.
Resumo:
The recognition of prior experiential learning (RPEL) involves the assessment ofskills and knowledge acquired by an individual through previous experience, which isnot necessarily related to an academic context. RPEL practices are far from generalisedin higher education, and there is a lack of specific guidelines on how to implement RPLprograms in particular settings, such as management education or online programs. TheRPEL pilot program developed in a Spanish virtual university is used throughout thearticle as the basis for further reflection on the design and implementation of RPEL inonline postgraduate education in the business field. The role of competences as a centraltheoretical foundation for RPEL is explained, and the context and characteristics of theRPEL program described. Special attention is paid to the key elements of the program¿sdesign and to the practical aspects of its implementation. The results of the program areassessed and general conclusions and suggestions for further research are discussed.
Resumo:
r1951, Perpignan, Casals Festival.
Resumo:
r1946.
Resumo:
An efficient flotation method based on the combination of flame atomic absorption spectrometry (FAAS) and separation and preconcentration step for determination of Cr3+, Cu 2+, Co2+, Ni2+, Zn2+, Cd 2+, Fe3+ and Pb2+ ions in various real samples by the possibility of applying bis(2-hydroxyacetophenone)-1,4-butanediimine (BHABDI) as a new collector was studied. The influence of pH, amount of BHABDI as collector, sample matrix, type and amount of eluting agent, type and amount of surfactant as floating agent, ionic strength and air flow rates i.e. variables affecting the efficiency of the extraction system was evaluated. It is ascertained that metal ions such as iron can be separated simultaneously from matrix in the presence of 0.012 mM ligand, 0.025% (w/v) of CTAB to a test sample of 750 mL at pH 6.5. These ions can be eluted quantitatively with 6 mL of 1.0 mol L-1 HNO3 in methanol which lead to the enrichment factor of 125. The detection limits for analyte ions were in the range of 1.3-2.4 ng mL-1. The method has been successfully applied for determination of trace amounts of ions in various real samples.
Resumo:
A simple ion pair-dispersive liquid-liquid microextraction method was proposed for preconcentration trace amounts of rhodium. An ion association complex of RhCl4- and tetradecyldimetylbenzylamonium was extracted into cholorobenzene. The volume and the type of extractive and dispersive solvents, the extraction time and the pH of the aqueous solutions were optimized. The calibration curve was linear in the range of 0.6-500 ng mL-1 of rhodium. The limit of detection was 0.10 ng mL-1 in initial solution and preconcentration factor was 40. The proposed method was successfully applied to the extraction and determination of rhodium in road dust and water samples.
Resumo:
In the proposed method, carbon tetrachloride and ethanol were used as extraction and dispersive solvents. Several factors that may be affected on the extraction process, such as extraction solvent, disperser solvent, the volume of extraction and disperser solvent, pH of the aqueous solution and extraction time were optimized. Under the optimal conditions, linearity was maintained between 1.0 ng mL-1 to 1.5 mg mL-1 for zinc and 1.0 ng mL-1 to 0.4 mg mL-1 for cadmium. The proposed method has been applied for determination of trace amount of zinc and cadmium in standard and water samples with satisfactory results.
Resumo:
A dispersive liquid-liquid microextraction based on solidification of floating organic drop for simultaneous extraction of trace amounts of nickel, cobalt and copper followed by their determination with electrothermal atomic absorption spectrometry was developed. 300 µL of acetone and 1-undecanol was injected into an aqueous sample containing diethyldithiocarbamate complexes of metal ions. For a sample volume of 10 mL, enrichment factors of 277, 270 and 300 and detection limits of 1.2, 1.1 and 1 ng L-1 for nickel, cobalt and copper were obtained, respectively. The method was applied to the extraction and determination of these metals in different water samples.
Resumo:
In this study, a procedure is developed for cloud point extraction of Pd(II) and Rh(III) ions in aqueous solution using Span 80 (non-ionic surfactant) prior to their determination by flame atomic absorption spectroscopy. This method is based on the extraction of Pd(II) and Rh(III) ions at a pH of 10 using Span 80 with no chelating agent. We investigated the effect of various parameters on the recovery of the analyte ions, including pH, equilibration temperature and time, concentration of Span 80, and ionic strength. Under the best experimental conditions, the limits of detection based on 3Sb for Pd(II) and Rh(III) ions were 1.3 and 1.2 ng mL-1, respectively. Seven replicate determinations of a mixture of 0.5 µg mL-1 palladium and rhodium ions gave a mean absorbance of 0.058 and 0.053 with relative standard deviations of 1.8 and 1.6%, respectively. The developed method was successfully applied to the extraction and determination of the palladium and rhodium ions in road dust and standard samples and satisfactory results were obtained.
Resumo:
In the present work, a simple and rapid ligand-less, in situ, surfactant-based solid phase extraction for the preconcentration of copper in water samples was developed. In this method, a cationic surfactant (n-dodecyltrimethylammonium bromide) was dissolved in an aqueous sample followed by the addition of an appropriate ion-pairing agent (ClO4-). Due to the interaction between the surfactant and ion-pairing agent, solid particles were formed and subsequently used for the adsorption of Cu(OH)2 and CuI. After centrifugation, the sediment was dissolved in 1.0 mL of 1 mol L-1 HNO3 in ethanol and aspirated directly into the flame atomic absorption spectrometer. In order to obtain the optimum conditions, several parameters affecting the performance of the LL-ISS-SPE, including the volumes of DTAB, KClO4, and KI, pH, and potentially interfering ions, were optimized. It was found that KI and phosphate buffer solution (pH = 9) could extract more than 95% of copper ions. The amount of copper ions in the water samples varied from 3.2 to 4.8 ng mL-1, with relative standard deviations of 98.5%-103%. The determination of copper in water samples was linear over a concentration range of 0.5-200.0 ng mL-1. The limit of detection (3Sb/m) was 0.1 ng mL-1 with an enrichment factor of 38.7. The accuracy of the developed method was verified by the determination of copper in two certified reference materials, producing satisfactory results.
Resumo:
P. 143-158 are misnumbered 142-157.