419 resultados para Polarizing microscopes.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The morphology of a novel poly(aryl ether ketone) [PEDEKmK] was investigated via polarizing optical microscopy (POM), TEM, DSC, SAXS and electron diffraction (ED). A distinct change in lamellar thickness, orientation, and spherulitic morphology was observed due to crystal melting and recrystallization. However, the crystal packing mode is found to be identical before and after the recrystallization process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The miscibility and crystallization behaviour of the blends of poly(ether ether ketone) (PEEK) with two thermoplastic polyimides (PI), PEI-E and YS-30, prepared by solution blending were studied by the use of small-angle X-ray scattering (SAXS), differential scanning calorimetry (d.s.c.) and polarizing microscopy techniques. The results obtained show that PEEK/YS-30 is miscible, while PEEK/PEI-E is partially miscible only in the composition range with PEI-E content up to 20 wt%. The crystallization behaviour of PEEK in PEEK/PI blends depends on the crystallization condition of the blend sample as well as the chemical structure and the content of the PI added. Our SAXS results indicate that the segregation of PI molecular chains during crystallization of PEEK chains in the blends is interfibrillar for PEEK/PEI-E blends, but interlamellar for PEEK/YS-30 blends. The compatibility and the crystallization behaviour are discussed in terms of charge transfer interaction between PI and PI molecules and between PI and PEEK molecules.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The synthesis of three new series of chiral Schiffs bases containing benzilideneaniline and 2-hydroxybenzilideneaniline moieties as mesogenic cores is presented. Differential scanning calorimetry, optical polarizing microscopy and X-ray diffraction measurements were used to study the phase transition temperatures and behaviour. The results reveal that most of these materials show chiral smectic mesomorphism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new series of fully aromatic thermotropic liquid crystalline copolyesters were synthesized by thermal polycondensation of p-hydroxybenzoic acid (PHB), terephthalic acid (TPA), resorcinol (RES) and bis (4-hydroxyphenyl) methanone (BHP). The DSC traces of copolyesters exhibited two or three endotherms, the low temperature endotherm(Tm) of which indicated the transition from solid state to anisotropic phase. Observation under polarizing microscope and WAXD measurements suggested that the LC-phase formed immediately above Tm had a nematic character.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO: Existem vários métodos para avaliar o crescimento da vegetação e a taxa de cobertura do solo. Medidas precisas e rápidas podem ser obtidas do tratamento digital de imagens geradas de câmeras fotográficas ou de vídeo. Há disponível, no mercado, diversos processadores de imagens que apresentam funções básicas semelhantes, mas com certas particularidades que poderão trazer maior benefício para o usuário, dependendo da aplicação. O SPRING, desenvolvido pelo INPE, é de domínio público, sendo mais abrangente do que um processador de imagens, incluindo funções de geoprocessamento. O ENVI foi desenvolvido para a análise de imagens multiespectrais e hiperespectrais, podendo também ser utilizado para o processamento de imagens obtidas de câmeras de vídeo, por exemplo. O KS-300 é um conjunto de hardware e de software destinado ao processamento e à quantificação de imagens microscópicas, permitindo a captação direta das imagens geradas por meio de lupas, microscópios eletrônicos ou câmeras de vídeo. O SIARCS foi desenvolvido pela Embrapa Instrumentação Agropecuária para tornar mais ágil o processo de captação de dados de um sistema. Este trabalho apresenta os fundamentos teóricos básicos envolvidos na técnica de análise de imagens, com as principais características dos softwares citados acima e sua aplicação na quantificação da taxa de crescimento e da cobertura do solo por espécies vegetais. ABSTRACT: Several methods exist to evaluate the growth of the vegetation and the tax of covering of the soil. Necessary and fast measures can be obtained of the digital treatment of generated images of photographic cameras or of video. There is available, in the market, several processors of images that you/they present similar basic functions, but with certain particularities that can bring larger benefit for the user, depending on the application. SPRING, developed by INPE, it is public domain, being including than a processor of images, including functions. ENVI was developed for the analysis of images multiespectrais and hiperespectrais, could also be used for the processing of obtained images of video cameras, for instance. The KS-300 it is a hardware group and software destined to the processing and quantification of microscopic images, allowing the direct reception of the images generated through magnifying glasses, eletronic microscopes or video cameras. SIARCS was developed by Embrapa Agricultural Instrumentation to turn more agile the process of reception of data of a system. This work presents the basic theoretical foundations involved in the technique of analysis of images, with the main characteristics of the softwares mentioned above and his application in the quantification of the growth tax and of the covering of the soil for vegetable species.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dual-layer frequency-selective subwavelength grid polarizers on thin-film dielectric substrates are proposed for THz and sub-THz applications. The dual-layer grids possess enhanced (squared) polarizing efficiency at a sequence of discrete frequencies in reflection and within extended frequency bands in transmission as compared to conventional single grids.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electron microscopy (EM) has advanced in an exponential way since the first transmission electron microscope (TEM) was built in the 1930’s. The urge to ‘see’ things is an essential part of human nature (talk of ‘seeing is believing’) and apart from scanning tunnel microscopes which give information about the surface, EM is the only imaging technology capable of really visualising atomic structures in depth down to single atoms. With the development of nanotechnology the demand to image and analyse small things has become even greater and electron microscopes have found their way from highly delicate and sophisticated research grade instruments to key-turn and even bench-top instruments for everyday use in every materials research lab on the planet. The semiconductor industry is as dependent on the use of EM as life sciences and pharmaceutical industry. With this generalisation of use for imaging, the need to deploy advanced uses of EM has become more and more apparent. The combination of several coinciding beams (electron, ion and even light) to create DualBeam or TripleBeam instruments for instance enhances the usefulness from pure imaging to manipulating on the nanoscale. And when it comes to the analytic power of EM with the many ways the highly energetic electrons and ions interact with the matter in the specimen there is a plethora of niches which evolved during the last two decades, specialising in every kind of analysis that can be thought of and combined with EM. In the course of this study the emphasis was placed on the application of these advanced analytical EM techniques in the context of multiscale and multimodal microscopy – multiscale meaning across length scales from micrometres or larger to nanometres, multimodal meaning numerous techniques applied to the same sample volume in a correlative manner. In order to demonstrate the breadth and potential of the multiscale and multimodal concept an integration of it was attempted in two areas: I) Biocompatible materials using polycrystalline stainless steel and II) Semiconductors using thin multiferroic films. I) The motivation to use stainless steel (316L medical grade) comes from the potential modulation of endothelial cell growth which can have a big impact on the improvement of cardio-vascular stents – which are mainly made of 316L – through nano-texturing of the stent surface by focused ion beam (FIB) lithography. Patterning with FIB has never been reported before in connection with stents and cell growth and in order to gain a better understanding of the beam-substrate interaction during patterning a correlative microscopy approach was used to illuminate the patterning process from many possible angles. Electron backscattering diffraction (EBSD) was used to analyse the crystallographic structure, FIB was used for the patterning and simultaneously visualising the crystal structure as part of the monitoring process, scanning electron microscopy (SEM) and atomic force microscopy (AFM) were employed to analyse the topography and the final step being 3D visualisation through serial FIB/SEM sectioning. II) The motivation for the use of thin multiferroic films stems from the ever-growing demand for increased data storage at lesser and lesser energy consumption. The Aurivillius phase material used in this study has a high potential in this area. Yet it is necessary to show clearly that the film is really multiferroic and no second phase inclusions are present even at very low concentrations – ~0.1vol% could already be problematic. Thus, in this study a technique was developed to analyse ultra-low density inclusions in thin multiferroic films down to concentrations of 0.01%. The goal achieved was a complete structural and compositional analysis of the films which required identification of second phase inclusions (through elemental analysis EDX(Energy Dispersive X-ray)), localise them (employing 72 hour EDX mapping in the SEM), isolate them for the TEM (using FIB) and give an upper confidence limit of 99.5% to the influence of the inclusions on the magnetic behaviour of the main phase (statistical analysis).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Real time monitoring of oxygenation and respiration is on the cutting edge of bioanalysis, including studies of cell metabolism, bioenergetics, mitochondrial function and drug toxicity. This thesis presents the development and evaluation of new luminescent probes and techniques for intracellular O2 sensing and imaging. A new oxygen consumption rate (OCR) platform based on the commercial microfluidic perfusion channel μ-slides compatible with extra- and intracellular O2 sensitive probes, different cell lines and measurement conditions was developed. The design of semi-closed channels allowed cell treatments, multiplexing with other assays and two-fold higher sensitivity to compare with microtiter plate. We compared three common OCR platforms: hermetically sealed quartz cuvettes for absolute OCRs, partially sealed with mineral oil 96-WPs for relative OCRs, and open 96-WPs for local cell oxygenation. Both 96-WP platforms were calibrated against absolute OCR platform with MEF cell line, phosphorescent O2 probe MitoXpress-Intra and time-resolved fluorescence reader. Found correlations allow tracing of cell respiration over time in a high throughput format with the possibility of cell stimulation and of changing measurement conditions. A new multimodal intracellular O2 probe, based on the phosphorescent reporter dye PtTFPP, fluorescent FRET donor and two-photon antennae PFO and cationic nanoparticles RL-100 was described. This probe, called MM2, possesses high brightness, photo- and chemical stability, low toxicity, efficient cell staining and high-resolution intracellular O2 imaging with 2D and 3D cell cultures in intensity, ratiometric and lifetime-based modalities with luminescence readers and FLIM microscopes. Extended range of O2 sensitive probes was designed and studied in order to optimize their spectral characteristics and intracellular targeting, using different NPs materials, delivery vectors, ratiometric pairs and IR dyes. The presented improvements provide useful tool for high sensitive monitoring and imaging of intracellular O2 in different measurement formats with wide range of physiological applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The receptor deleted in colorectal cancer (DCC) directs dynamic polarizing activities in animals toward its extracellular ligand netrin. How DCC polarizes toward netrin is poorly understood. By performing live-cell imaging of the DCC orthologue UNC-40 during anchor cell invasion in Caenorhabditis elegans, we have found that UNC-40 clusters, recruits F-actin effectors, and generates F-actin in the absence of UNC-6 (netrin). Time-lapse analyses revealed that UNC-40 clusters assemble, disassemble, and reform at periodic intervals in different regions of the cell membrane. This oscillatory behavior indicates that UNC-40 clusters through a mechanism involving interlinked positive (formation) and negative (disassembly) feedback. We show that endogenous UNC-6 and ectopically provided UNC-6 orient and stabilize UNC-40 clustering. Furthermore, the UNC-40-binding protein MADD-2 (a TRIM family protein) promotes ligand-independent clustering and robust UNC-40 polarization toward UNC-6. Together, our data suggest that UNC-6 (netrin) directs polarized responses by stabilizing UNC-40 clustering. We propose that ligand-independent UNC-40 clustering provides a robust and adaptable mechanism to polarize toward netrin.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Probe-based scanning microscopes, such as the STM and the AFM, are used to obtain the topographical and electronic structure maps of material surfaces, and to modify their morphologies on nanoscopic scales. They have generated new areas of research in condensed matter physics and materials science. We will review some examples from the fields of experimental nano-mechanics, nano-electronics and nano-magnetism. These now form the basis of the emerging field of Nano-technology. A parallel development has been brought about in the field of Computational Nano-science, using quantum-mechanical techniques and computer-based numerical modelling, such as the Molecular Dynamics (MD) simulation method. We will report on the simulation of nucleation and growth of nano-phase films on supporting substrates. Furthermore, a theoretical modelling of the formation of STM images of metallic clusters on metallic substrates will also be discussed within the non-equilibrium Keldysh Green function method to study the effects of coherent tunnelling through different atomic orbitals in a tip-sample geometry.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This memoir recalls the instruments in the Electron Microscope Unit and the staff, students and visitors who used them. Accessory equipment is also described because much of it was innovative and built in the laboratory, also, much of the science would not have been possible without it. This publication includes 33 figures, 4 plates and 7 appendices. The appendices record that 54 MBA staff and 196 students and visitors have used the microscopes and that 413 titles have been published (to the end of 2006).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

New ionic liquid crystals (including ionic metallomesogens) based oil the pyrrolidinium core are presented. N-Methylpyrrolidine was quaternized with different mesogenic groups connected to a flexible, omega-bromosubstituted alkyl spacer. The length of the flexible alkyl spacer between the cationic head group and the rigid mesogenic group was varied. The substituted pyrrolidinium cations were combined with bromide, bis(trifluoromethylsulfonyl)imide, tetrakis (2-thenoyltrifluoroacetonato)europate(III), and tetrabromouranyl anions. The influence of the type of mesogenic unit, the lengths of the flexible spacer and terminal alkyl chain, the size of the mesogenic group, and the type of anion oil the thermotropic mesomorphic behavior was investigated. Furthermore, the phase behavior was thoroughly compared with the previously reported mesomorphism of N-alkyl-N-methylpyrrolidinium salts. Low-ordered smectic A phases of the de Vries type, smectic C phases, higher-ordered smectic F/I phases, as well its crystal smectic phases (E and G, J, H, or K) were observed and investigated by polarizing optical microscopy, differential scanning calorimetry, and powder X-ray diffraction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article presents a cascaded arrangement comprising a double-layer frequency selective surface circularly polarizing (CPFSS) and a second screen that can be switched between artificial magnetic conduction (AMC) or perfect electric conducting. (PEC) states. The CPFSS consists of two stacked aluminium sheets patterned with periodic split ring structures While the AMC is a PCB sheet patterned with metallic squares interconnected by links By either open or short circuiting these links it is shown that the cascade of screens can be made to twist, or not to twist, an incident 45 degrees linearly polirized signal through 90 degrees upon reflection from the assembly The system was designed and optimized using CST software and predictions were validated experimentally and measured monostatic reflection loss results (C) 2010 Wiley Periodicals, Inc Microwave Opt Technol Lett 52 577-580, 2010. Published online in Wiley InterScience (www.interscience.wiley.com) DOI 10.1002/mop.24979

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An electronically tunable reflection polarizer which exploits the dielectric anisotropy of nematic liquid crystals (LC) has been designed, fabricated and measured in a frequency band centered at 130 GHz. The phase agile polarizing mirror converts an incident slant 45° signal upon reflection to right hand circular (RHCP), orthogonal linear (-45 °) or left hand circular (LHCP) polarization depending on the value of the voltage biasing the LC mixture. In the experimental set-up this is achieved by applying a low frequency bias voltage of 0 V, 40 V and 89 V respectively, across the cavity containing the LC material.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pollen grains are microscopic so their identification and quantification has, for decades, depended upon human observers using light microscopes: a labour-intensive approach. Modern improvements in computing and imaging hardware and software now bring automation of pollen analyses within reach. In this paper, we provide the first review in over 15 yr of progress towards automation of the part of palynology concerned with counting and classifying pollen, bringing together literature published from a wide spectrum of sources. We
consider which attempts offer the most potential for an automated palynology system for universal application across all fields of research concerned with pollen classification and counting. We discuss what is required to make the datasets of these automated systems as acceptable as those produced by human palynologists, and present suggestions for how automation will generate novel approaches to counting and classifying pollen that have hitherto been unthinkable.