966 resultados para Plaque Purification
Resumo:
Rupture of vulnerable plaques is the main cause of acute cardiovascular events. However, mechanisms responsible for transforming a stable into a vulnerable plaque remain elusive. Angiotensin II, a key regulator of blood pressure homeostasis, has a potential role in atherosclerosis. To study the contribution of angiotensin II in plaque vulnerability, we generated hypertensive hypercholesterolemic ApoE-/- mice with either normal or endogenously increased angiotensin II production (renovascular hypertension models). Hypertensive high angiotensin II ApoE-/- mice developed unstable plaques, whereas in hypertensive normal angiotensin II ApoE-/- mice plaques showed a stable phenotype. Vulnerable plaques from high angiotensin II ApoE-/- mice had thinner fibrous cap (P<0.01), larger lipid core (P<0.01), and increased macrophage content (P<0.01) than even more hypertensive but normal angiotensin II ApoE-/- mice. Moreover, in mice with high angiotensin II, a skewed T helper type 1-like phenotype was observed. Splenocytes from high angiotensin II ApoE-/- mice produced significantly higher amounts of interferon (IFN)-gamma than those from ApoE-/- mice with normal angiotensin II; secretion of IL4 and IL10 was not different. In addition, we provide evidence for a direct stimulating effect of angiotensin II on lymphocyte IFN-gamma production. These findings suggest a new mechanism in plaque vulnerability demonstrating that angiotensin II, within the context of hypertension and hypercholesterolemia, independently from its hemodynamic effect behaves as a local modulator promoting the induction of vulnerable plaques probably via a T helper switch.
Resumo:
PURPOSE: To examine the impact of spatial resolution and respiratory motion on the ability to accurately measure atherosclerotic plaque burden and to visually identify atherosclerotic plaque composition. MATERIALS AND METHODS: Numerical simulations of the Bloch equations and vessel wall phantom studies were performed for different spatial resolutions by incrementally increasing the field of view. In addition, respiratory motion was simulated based on a measured physiologic breathing pattern. RESULTS: While a spatial resolution of > or = 6 pixels across the wall does not result in significant errors, a resolution of < or = 4 pixels across the wall leads to an overestimation of > 20%. Using a double-inversion T2-weighted turbo spin echo sequence, a resolution of 1 pixel across equally thick tissue layers (fibrous cap, lipid, smooth muscle) and a respiratory motion correction precision (gating window) of three times the thickness of the tissue layer allow for characterization of the different coronary wall components. CONCLUSIONS: We found that measurements in low-resolution black blood images tend to overestimate vessel wall area and underestimate lumen area.
Resumo:
Référence bibliographique : Rol, 56098
Resumo:
Purpose: Atheromatic plaque progression is affected, among others phenomena, by biomechanical, biochemical, and physiological factors. In this paper, the authors introduce a novel framework able to provide both morphological (vessel radius, plaque thickness, and type) and biomechanical (wall shear stress and Von Mises stress) indices of coronary arteries. Methods: First, the approach reconstructs the three-dimensional morphology of the vessel from intravascular ultrasound(IVUS) and Angiographic sequences, requiring minimal user interaction. Then, a computational pipeline allows to automatically assess fluid-dynamic and mechanical indices. Ten coronary arteries are analyzed illustrating the capabilities of the tool and confirming previous technical and clinical observations. Results: The relations between the arterial indices obtained by IVUS measurement and simulations have been quantitatively analyzed along the whole surface of the artery, extending the analysis of the coronary arteries shown in previous state of the art studies. Additionally, for the first time in the literature, the framework allows the computation of the membrane stresses using a simplified mechanical model of the arterial wall. Conclusions: Circumferentially (within a given frame), statistical analysis shows an inverse relation between the wall shear stress and the plaque thickness. At the global level (comparing a frame within the entire vessel), it is observed that heavy plaque accumulations are in general calcified and are located in the areas of the vessel having high wall shear stress. Finally, in their experiments the inverse proportionality between fluid and structural stresses is observed.
Resumo:
Nanotiltration is a membrane separation method known for its special characteristic of rejecting multivalent ions and passing monovalent ions. Thus, it is commonly applied with dilute aqueous solutions in partial salt removal, like in drinking water production. The possibilities of nanofiltration have been studied and the technique applied in a wide branch of industries, e.g. the pulp and paper, the textile and the chemical processing industry. However, most present applications and most of the potential applications studied involve dilute solutions, the permeating stream being generally water containing monovalent salts. In this study nanotiltration is investigated more as a fractionation method. A well-known application in the dairy industry is concentration and partial salt removal from whey. Concentration and partial demineralization is beneficial for futher processing of whey as whey concentrates are used e.g. in baby foods. In the experiments of this study nanotiltration effectively reduced the monovalent salts in the whey concentrate. The main concern in this application is lactose leakage into the permeate. With the nanofiltration membranes used the lactose retentions were practically ? 99%. Another dairy application studied was the purification and reuse of cleaning solutions. This is an environmentally driven application. An 80% COD reduction by nanofiltration was observed for alkaline cleaning-in-place solution. Nanofiltration is not as commonly applied in the sugar and sweeteners industry as in the dairy industry. In this study one potential application was investigated, namely xylose purification from hemicellulose hydrolyzate. Xylose is raw material for xylitol production. Xylose separation from glucose was initially studied with xylose-glucose model solutions. The ability of nanofiltration to partially separate xylose into the permeate from rather concentrated xylose-glucose solutions (10 w-% and 30 w-%) became evident. The difference in size between xylose and glucose molecules according to any size measure is small, e.g. the Stokes diameter of glucose is 0.73 nm compared to 0.65 nm for xylose. In further experiments, xylose was purified into nanoliltration permeate from a hemicellulose hydrolyzate solution. The xylose content in the total solids was increased by 1.4—1.7 fold depending on temperature, pressure and feed composition.
Resumo:
PURPOSE: To preliminarily test the hypothesis that fluorine 19 ((19)F) magnetic resonance (MR) imaging enables the noninvasive in vivo identification of plaque inflammation in a mouse model of atherosclerosis, with histologic findings as the reference standard. MATERIALS AND METHODS: The animal studies were approved by the local animal ethics committee. Perfluorocarbon (PFC) emulsions were injected intravenously in a mouse model of atherosclerosis (n = 13), after which (19)F and anatomic MR imaging were performed at the level of the thoracic aorta and its branches at 9.4 T. Four of these animals were imaged repeatedly (at 2-14 days) to determine the optimal detection time. Repeated-measures analysis of variance with a Tukey test was applied to determine if there was a significant change in (19)F signal-to-noise ratio (SNR) of the plaques and liver between the time points. Six animals were injected with a PFC emulsion that also contained a fluorophore. As a control against false-positive results, wild-type mice (n = 3) were injected with a PFC emulsion, and atherosclerotic mice were injected with a saline solution (n = 2). The animals were sacrificed after the last MR imaging examination, after which high-spatial-resolution ex vivo MR imaging and bright-field and immunofluorescent histologic examination were performed. RESULTS: (19)F MR signal was detected in vivo in plaques in the aortic arch and its branches. The SNR was found to significantly increase up to day 6 (P < .001), and the SNR of all mice at this time point was 13.4 ± 3.3. The presence of PFC and plaque in the excised vessels was then confirmed both through ex vivo (19)F MR imaging and histologic examination, while no signal was detected in the control animals. Immunofluorescent histologic findings confirmed the presence of PFC in plaque macrophages. CONCLUSION: (19)F MR imaging allows the noninvasive in vivo detection of inflammation in atherosclerotic plaques in a mouse model of atherosclerosis and opens up new avenues for both the early detection of vulnerable atherosclerosis and the elucidation of inflammation mechanisms in atherosclerosis.
Resumo:
Purpose: Atheromatic plaque progression is affected, among others phenomena, by biomechanical, biochemical, and physiological factors. In this paper, the authors introduce a novel framework able to provide both morphological (vessel radius, plaque thickness, and type) and biomechanical (wall shear stress and Von Mises stress) indices of coronary arteries. Methods: First, the approach reconstructs the three-dimensional morphology of the vessel from intravascular ultrasound(IVUS) and Angiographic sequences, requiring minimal user interaction. Then, a computational pipeline allows to automatically assess fluid-dynamic and mechanical indices. Ten coronary arteries are analyzed illustrating the capabilities of the tool and confirming previous technical and clinical observations. Results: The relations between the arterial indices obtained by IVUS measurement and simulations have been quantitatively analyzed along the whole surface of the artery, extending the analysis of the coronary arteries shown in previous state of the art studies. Additionally, for the first time in the literature, the framework allows the computation of the membrane stresses using a simplified mechanical model of the arterial wall. Conclusions: Circumferentially (within a given frame), statistical analysis shows an inverse relation between the wall shear stress and the plaque thickness. At the global level (comparing a frame within the entire vessel), it is observed that heavy plaque accumulations are in general calcified and are located in the areas of the vessel having high wall shear stress. Finally, in their experiments the inverse proportionality between fluid and structural stresses is observed.
Resumo:
Viime vuosien nopea kehitys on kiihdyttänyt uusien lääkkeiden kehittämisprosessia. Kombinatorinen kemia on tehnyt mahdolliseksi syntetisoida suuria kokoelmia rakenteeltaan toisistaan poikkeavia molekyylejä, nk. kombinatorisia kirjastoja, biologista seulontaa varten. Siinä molekyylien rakenteeseen liittyvä aktiivisuus tutkitaan useilla erilaisilla biologisilla testeillä mahdollisten "osumien" löytämiseksi, joista osasta saatetaan myöhemmin kehittää uusia lääkeaineita. Jotta biologisten tutkimusten tulokset olisivat luotettavia, on syntetisoitujen komponenttien oltava mahdollisimman puhtaita. Tämän vuoksi tarvitaan HTP-puhdistusta korkealaatuisten komponenttien ja luotettavan biologisen tiedon takaamiseksi. Jatkuvasti kasvavat tuotantovaatimukset ovat johtaneet näiden puhdistustekniikoiden automatisointiin ja rinnakkaistamiseen. Preparatiivinen LC/MS soveltuu kombinatoristen kirjastojen nopeaan ja tehokkaaseen puhdistamiseen. Monet tekijät, esimerkiksi erotuskolonnin ominaisuudet sekä virtausgradientti, vaikuttavat preparatiivisen LC/MS puhdistusprosessin tehokkuuteen. Nämä parametrit on optimoitava parhaan tuloksen saamiseksi. Tässä työssä tutkittiin emäksisiä komponentteja erilaisissa virtausolosuhteissa. Menetelmä kombinatoristen kirjastojen puhtaustason määrittämiseksi LC/MS-puhdistuksen jälkeen optimoitiin ja määritettiin puhtaus joillekin komponenteille eri kirjastoista ennen puhdistusta.
Resumo:
La fracture périprothétique du fémur (FPF) représente une complication sérieuse des arthroplasties de hanche. Différents matériels d'ostéosynthèse ont été utilisés pour l'ostéosynthèse des FPFs. Toutefois, aucune étude n'a rapporté les résultats obtenus avec une plaque anatomique non-verrouillée avec des trous excentrés. Les buts de ce travail étaient de présenter 1) le taux de consolidation des FPF traitées par cet implant, 2) les caractéristiques péri-opératoires 3) le taux de complications, et 4) les résultats en terme d'autonomie obtenus après le traitement des FPF du groupe B selon Vancouver avec une plaque anatomique à trous excentrés. Hypothèse L'utilisation de cette plaque permet d'obtenir un taux élevé de consolidation avec un minimum de complications mécaniques. Matériels et Méthodes Quarante-trois patients, d'âge moyen 79 ans ± 13 (41 - 98), qui ont été traités pour une ostéosynthèse d'une FPF de type B selon Vancouver avec cette plaque entre 2002 et 2007 ont été inclus. Les patients ont été classifiées selon les scores ASA et de Charnley. Le temps opératoire, les pertes sanguines chirurgicales, le nombre de transfusion, la durée d'hospitalisation, le délai de consolidation, le lieu de vie ainsi que l'autonomie (score de Parker) ont été évalués. Le taux de survie sans révision a été calculé par la méthode de Kaplan-Meier. Le recul moyen est de 42 mois ± 20 (min - max : 16 - 90). Résultats La consolidation a été obtenue chez tous les patients avec un délai moyen de 2,4 mois ± 0,6 (2-4). 1 patient avec un cal vicieux en varus était à déplorer. Le score de Parker a diminué de 5,93 ± 1,94 (2-9) à 4,93 ± 1,8 (1- 9) (p = 0.01). 2 révisions chirurgicales ont été nécessaires sur la série. Le taux de survie à 5 ans des prothèses après ostéosynthèse de la FPF était de 83,3 % ± 12,6 %. Conclusion Cette plaque anatomique avec trous excentrés permet le traitement des FPF du type B et garantit une consolidation de la fracture avec un faible taux de complications liés à l'ostéosynthèse. Toutefois, les FPF représentent une complication sérieuse des arthroplasties de hanche assortie d'un fort taux de morbidités et de mortalité.
Resumo:
The aim of this work is to obtain, purify and characterize biochemically a peroxidase from Copaifera langsdorffii leaves (COP). COP was obtained by acetone precipitation followed by ion-exchange chromatography. Purification yielded 3.5% of peroxidase with the purification factor of 46.86. The COP optimum pH is 6.0 and the temperature is 35 ºC. COP was stable in the pH range of 4.5 to 9.3 and at temperatures below 50.0 ºC. The apparent Michaelis-Menten constants (Km) for guaiacol and H2O2 were 0.04 mM and 0.39 mM respectively. Enzyme turnover was 0.075 s-1 for guaiacol and 0.28 s-1 for hydrogen peroxide. Copaifera langsdorffii leaves showed to be a rich source of active peroxidase (COP) during the whole year. COP could replace HRP, the most used peroxidase, in analytical determinations and treatment of industrial effluents at low cost.