884 resultados para Performance analysis


Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of this study was to compare time-motion indicators during judo matches performed by athletes from different age groups. The following age groups were analysed: Pre-Juvenile (13-14 years, n=522), Juvenile (15-16 years, n 353); Junior (19 years, n = 349) and Senior (>20 years, n = 587). The time-motion indicators included: Total Combat Time, Standing Combat Time, Displacement Without Contact, Gripping Time, Groundwork Combat Time and Pause Time. Analysis of variance (ANOVA) one-way and the Tukey test, as well as the Kruskal-Wallis test and Mann-Whitney (for non-parametric data), were conducted, using P < 0.05 as significance level. The results showed that all analysed groups obtained a median of 7 (first quantile - 3, third quantile - 12) sequences of combat/pause cycles. In total time of combat, the result was: for Total Combat Time, Standing Combat Time and Gripping Time: Pre-Juvenile and Senior were significantly longer than Juvenile and Junior. Considering Displacement Without Contact, Junior was significantly longer than all other age groups. For Groundwork Combat Time, Senior was significantly longer than all other age groups and Pre-Juvenile was longer than Junior. These results can be used to improve the physiological performance in intermittent practices, as well as technicaltactical training during judo sessions.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The study is aimed to calculate an innovative numerical index for bit performance evaluation called Bit Index (BI), applied on a new type of bit database named Formation Drillability Catalogue (FDC). A dedicated research programme (developed by Eni E&P and the University of Bologna) studied a drilling model for bit performance evaluation named BI, derived from data recorded while drilling (bit records, master log, wireline log, etc.) and dull bit evaluation. This index is calculated with data collected inside the FDC, a novel classification of Italian formations aimed to the geotechnical and geomechanical characterization and subdivisions of the formations, called Minimum Interval (MI). FDC was conceived and prepared at Eni E&P Div., and contains a large number of significant drilling parameters. Five wells have been identified inside the FDC and have been tested for bit performance evaluation. The values of BI are calculated for each bit run and are compared with the values of the cost per metre. The case study analyzes bits of the same type, diameters and run in the same formation. The BI methodology implemented on MI classification of FDC can improve consistently the bit performances evaluation, and it helps to identify the best performer bits. Moreover, FDC turned out to be functional to BI, since it discloses and organizes formation details that are not easily detectable or usable from bit records or master logs, allowing for targeted bit performance evaluations. At this stage of development, the BI methodology proved to be economic and reliable. The quality of bit performance analysis obtained with BI seems also more effective than the traditional “quick look” analysis, performed on bit records, or on the pure cost per metre evaluation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

[EN]A new parallel algorithm for simultaneous untangling and smoothing of tetrahedral meshes is proposed in this paper. We provide a detailed analysis of its performance on shared-memory many-core computer architectures. This performance analysis includes the evaluation of execution time, parallel scalability, load balancing, and parallelism bottlenecks. Additionally, we compare the impact of three previously published graph coloring procedures on the performance of our parallel algorithm. We use six benchmark meshes with a wide range of sizes. Using these experimental data sets, we describe the behavior of the parallel algorithm for different data sizes. We demonstrate that this algorithm is highly scalable when it runs on two different high-performance many-core computers with up to 128 processors...

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In such territories where food production is mostly scattered in several small / medium size or even domestic farms, a lot of heterogeneous residues are produced yearly, since farmers usually carry out different activities in their properties. The amount and composition of farm residues, therefore, widely change during year, according to the single production process periodically achieved. Coupling high efficiency micro-cogeneration energy units with easy handling biomass conversion equipments, suitable to treat different materials, would provide many important advantages to the farmers and to the community as well, so that the increase in feedstock flexibility of gasification units is nowadays seen as a further paramount step towards their wide spreading in rural areas and as a real necessity for their utilization at small scale. Two main research topics were thought to be of main concern at this purpose, and they were therefore discussed in this work: the investigation of fuels properties impact on gasification process development and the technical feasibility of small scale gasification units integration with cogeneration systems. According to these two main aspects, the present work was thus divided in two main parts. The first one is focused on the biomass gasification process, that was investigated in its theoretical aspects and then analytically modelled in order to simulate thermo-chemical conversion of different biomass fuels, such as wood (park waste wood and softwood), wheat straw, sewage sludge and refuse derived fuels. The main idea is to correlate the results of reactor design procedures with the physical properties of biomasses and the corresponding working conditions of gasifiers (temperature profile, above all), in order to point out the main differences which prevent the use of the same conversion unit for different materials. At this scope, a gasification kinetic free model was initially developed in Excel sheets, considering different values of air to biomass ratio and the downdraft gasification technology as particular examined application. The differences in syngas production and working conditions (process temperatures, above all) among the considered fuels were tried to be connected to some biomass properties, such elementary composition, ash and water contents. The novelty of this analytical approach was the use of kinetic constants ratio in order to determine oxygen distribution among the different oxidation reactions (regarding volatile matter only) while equilibrium of water gas shift reaction was considered in gasification zone, by which the energy and mass balances involved in the process algorithm were linked together, as well. Moreover, the main advantage of this analytical tool is the easiness by which the input data corresponding to the particular biomass materials can be inserted into the model, so that a rapid evaluation on their own thermo-chemical conversion properties is possible to be obtained, mainly based on their chemical composition A good conformity of the model results with the other literature and experimental data was detected for almost all the considered materials (except for refuse derived fuels, because of their unfitting chemical composition with the model assumptions). Successively, a dimensioning procedure for open core downdraft gasifiers was set up, by the analysis on the fundamental thermo-physical and thermo-chemical mechanisms which are supposed to regulate the main solid conversion steps involved in the gasification process. Gasification units were schematically subdivided in four reaction zones, respectively corresponding to biomass heating, solids drying, pyrolysis and char gasification processes, and the time required for the full development of each of these steps was correlated to the kinetics rates (for pyrolysis and char gasification processes only) and to the heat and mass transfer phenomena from gas to solid phase. On the basis of this analysis and according to the kinetic free model results and biomass physical properties (particles size, above all) it was achieved that for all the considered materials char gasification step is kinetically limited and therefore temperature is the main working parameter controlling this step. Solids drying is mainly regulated by heat transfer from bulk gas to the inner layers of particles and the corresponding time especially depends on particle size. Biomass heating is almost totally achieved by the radiative heat transfer from the hot walls of reactor to the bed of material. For pyrolysis, instead, working temperature, particles size and the same nature of biomass (through its own pyrolysis heat) have all comparable weights on the process development, so that the corresponding time can be differently depending on one of these factors according to the particular fuel is gasified and the particular conditions are established inside the gasifier. The same analysis also led to the estimation of reaction zone volumes for each biomass fuel, so as a comparison among the dimensions of the differently fed gasification units was finally accomplished. Each biomass material showed a different volumes distribution, so that any dimensioned gasification unit does not seem to be suitable for more than one biomass species. Nevertheless, since reactors diameters were found out quite similar for all the examined materials, it could be envisaged to design a single units for all of them by adopting the largest diameter and by combining together the maximum heights of each reaction zone, as they were calculated for the different biomasses. A total height of gasifier as around 2400mm would be obtained in this case. Besides, by arranging air injecting nozzles at different levels along the reactor, gasification zone could be properly set up according to the particular material is in turn gasified. Finally, since gasification and pyrolysis times were found to considerably change according to even short temperature variations, it could be also envisaged to regulate air feeding rate for each gasified material (which process temperatures depend on), so as the available reactor volumes would be suitable for the complete development of solid conversion in each case, without even changing fluid dynamics behaviour of the unit as well as air/biomass ratio in noticeable measure. The second part of this work dealt with the gas cleaning systems to be adopted downstream the gasifiers in order to run high efficiency CHP units (i.e. internal engines and micro-turbines). Especially in the case multi–fuel gasifiers are assumed to be used, weightier gas cleaning lines need to be envisaged in order to reach the standard gas quality degree required to fuel cogeneration units. Indeed, as the more heterogeneous feed to the gasification unit, several contaminant species can simultaneously be present in the exit gas stream and, as a consequence, suitable gas cleaning systems have to be designed. In this work, an overall study on gas cleaning lines assessment is carried out. Differently from the other research efforts carried out in the same field, the main scope is to define general arrangements for gas cleaning lines suitable to remove several contaminants from the gas stream, independently on the feedstock material and the energy plant size The gas contaminant species taken into account in this analysis were: particulate, tars, sulphur (in H2S form), alkali metals, nitrogen (in NH3 form) and acid gases (in HCl form). For each of these species, alternative cleaning devices were designed according to three different plant sizes, respectively corresponding with 8Nm3/h, 125Nm3/h and 350Nm3/h gas flows. Their performances were examined on the basis of their optimal working conditions (efficiency, temperature and pressure drops, above all) and their own consumption of energy and materials. Successively, the designed units were combined together in different overall gas cleaning line arrangements, paths, by following some technical constraints which were mainly determined from the same performance analysis on the cleaning units and from the presumable synergic effects by contaminants on the right working of some of them (filters clogging, catalysts deactivation, etc.). One of the main issues to be stated in paths design accomplishment was the tars removal from the gas stream, preventing filters plugging and/or line pipes clogging At this scope, a catalytic tars cracking unit was envisaged as the only solution to be adopted, and, therefore, a catalytic material which is able to work at relatively low temperatures was chosen. Nevertheless, a rapid drop in tars cracking efficiency was also estimated for this same material, so that an high frequency of catalysts regeneration and a consequent relevant air consumption for this operation were calculated in all of the cases. Other difficulties had to be overcome in the abatement of alkali metals, which condense at temperatures lower than tars, but they also need to be removed in the first sections of gas cleaning line in order to avoid corrosion of materials. In this case a dry scrubber technology was envisaged, by using the same fine particles filter units and by choosing for them corrosion resistant materials, like ceramic ones. Besides these two solutions which seem to be unavoidable in gas cleaning line design, high temperature gas cleaning lines were not possible to be achieved for the two larger plant sizes, as well. Indeed, as the use of temperature control devices was precluded in the adopted design procedure, ammonia partial oxidation units (as the only considered methods for the abatement of ammonia at high temperature) were not suitable for the large scale units, because of the high increase of reactors temperature by the exothermic reactions involved in the process. In spite of these limitations, yet, overall arrangements for each considered plant size were finally designed, so that the possibility to clean the gas up to the required standard degree was technically demonstrated, even in the case several contaminants are simultaneously present in the gas stream. Moreover, all the possible paths defined for the different plant sizes were compared each others on the basis of some defined operational parameters, among which total pressure drops, total energy losses, number of units and secondary materials consumption. On the basis of this analysis, dry gas cleaning methods proved preferable to the ones including water scrubber technology in al of the cases, especially because of the high water consumption provided by water scrubber units in ammonia adsorption process. This result is yet connected to the possibility to use activated carbon units for ammonia removal and Nahcolite adsorber for chloride acid. The very high efficiency of this latter material is also remarkable. Finally, as an estimation of the overall energy loss pertaining the gas cleaning process, the total enthalpy losses estimated for the three plant sizes were compared with the respective gas streams energy contents, these latter obtained on the basis of low heating value of gas only. This overall study on gas cleaning systems is thus proposed as an analytical tool by which different gas cleaning line configurations can be evaluated, according to the particular practical application they are adopted for and the size of cogeneration unit they are connected to.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Strategic control is defined as the use of qualitative and quantitative tools for the evaluation of strategic organizational performance. Most research in strategic planning has focused on strategy formulation and implementation, but little work has been done on strategic performance evaluation particularly in the area of cancer research. The objective of this study was to identify strategic control approaches and financial performance metrics used by major cancer centers in the country as an initial step in expanding the theory and practice behind strategic organizational performance. Focusing on hospitals which share similar mandate and resource constraints was expected to improve measurement precision. The results indicate that most cancer centers use a wide selection of evaluation tools, but sophisticated analytical approaches were less common. In addition, there was evidence that high-performing centers tend to invest a larger degree of resources in the area of strategic performance analysis than centers showing lower financial results. The conclusions point to the need for incorporating higher degree of analytical power in order to improve the tracking of strategic performance. This study is one of the first to concentrate in the area of strategic control.^

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Performance of football teams varies constantly due to the dynamic nature of this sport, whilst the typical performance and its spread can be represented by profiles combining different performance-related variables based on data from multiple matches. The current study aims to use a profiling technique to evaluate and compare match performance of football teams in the UEFA Champions League incorporating three situational variables (i.e. strength of team and opponent, match outcome and match location). Match statistics of 72 teams, 496 games across four seasons (2008-09 to 2012-13) of this competition were analysed. Sixteen performance-related events were included: shots, shots on target, shots from open play, shots from set piece, shots from counter attack, passes, pass accuracy (%), crosses, through balls, corners, dribbles, possession, aerial success (%), fouls, tackles, and yellow cards. Teams were classified into three levels of strength by a k-cluster analysis. Profiles of overall performance and profiles incorporating three situational variables for teams of all three levels of strength were set up by presenting the mean, standard deviation, median, lower and upper quartiles of the counts of each event to represent their typical performances and spreads. Means were compared by using one-way ANOVA and independent sample t test (for match location, home and away differences), and were plotted into the same radar charts after unifying all the event counts by standardised score. Established profiles can present straightforwardly typical performances of football teams of different levels playing in different situations, which could provide detailed references for coaches and analysts to evaluate performances of upcoming opposition and of their own.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of the study was to evaluate the match work-rate of Chinese field hockey players by analyzing the distance covered at different intensities pooled by specific positions during different periods of matches. Thirty-eight players from twenty-four male field hockey matches at the 11th Chinese National Games were filmed and analyzed.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The aim of the study was to evaluate the match work-rate of Chinese field hockey players by analyzing the distance covered at different intensities pooled by specific positions during different periods of matches. Thirty-eight players from twenty-four male field hockey matches at the 11th Chinese National Games were filmed and analyzed.mas

Relevância:

70.00% 70.00%

Publicador:

Resumo:

El MC en baloncesto es aquel fenómeno relacionado con el juego que presenta unas características particulares determinadas por la idiosincrasia de un equipo y puede afectar a los protagonistas y por ende al devenir del juego. En la presente Tesis se ha estudiado la incidencia del MC en Liga A.C.B. de baloncesto y para su desarrollo en profundidad se ha planteado dos investigaciones una cuantitativa y otra cualitativa cuya metodología se detalla a continuación: La investigación cuantitativa se ha basado en la técnica de estudio del “Performance analysis”, para ello se han estudiado cuatro temporadas de la Liga A.C.B. (del 2007/08 al 2010/11), tal y como refleja en la bibliografía consultada se han tomado como momentos críticos del juego a los últimos cinco minutos de partidos donde la diferencia de puntos fue de seis puntos y todos los Tiempos Extras disputados, de tal manera que se han estudiado 197 momentos críticos. La contextualización del estudio se ha hecho en función de la variables situacionales “game location” (local o visitante), “team quality” (mejores o peores clasificados) y “competition” (fases de LR y Playoff). Para la interpretación de los resultados se han realizado los siguientes análisis descriptivos: 1) Análisis Discriminante, 2) Regresión Lineal Múltiple; y 3) Análisis del Modelo Lineal General Multivariante. La investigación cualitativa se ha basado en la técnica de investigación de la entrevista semiestructurada. Se entrevistaron a 12 entrenadores que militaban en la Liga A.C.B. durante la temporada 2011/12, cuyo objetivo ha sido conocer el punto de vista que tiene el entrenador sobre el concepto del MC y que de esta forma pudiera dar un enfoque más práctico basado en su conocimiento y experiencia acerca de cómo actuar ante el MC en el baloncesto. Los resultados de ambas investigaciones coinciden en señalar la importancia del MC sobre el resultado final del juego. De igual forma, el concepto en sí entraña una gran complejidad por lo que se considera fundamental la visión científica de la observación del juego y la percepción subjetiva que presenta el entrenador ante el fenómeno, para la cual los aspectos psicológicos de sus protagonistas (jugadores y entrenadores) son determinantes. ABSTRACT The Critical Moment (CM) in basketball is a related phenomenon with the game that has particular features determined by the idiosyncrasies of a team and can affect the players and therefore the future of the game. In this Thesis we have studied the impact of CM in the A.C.B. League and from a profound development two investigations have been raised, quantitative and qualitative whose methodology is as follows: The quantitative research is based on the technique of study "Performance analysis", for this we have studied four seasons in the A.C.B. League (2007/08 to 2010/11), and as reflected in the literature the Critical Moments of the games were taken from the last five minutes of games where the point spread was six points and all overtimes disputed, such that 197 critical moments have been studied. The contextualization of the study has been based on the situational variables "game location" (home or away), "team quality" (better or lower classified) and "competition" (LR and Playoff phases). For the interpretation of the results the following descriptive analyzes were performed: 1) Discriminant Analysis, 2) Multiple Linear Regression Analysis; and 3) Analysis of Multivariate General Linear Model. Qualitative research is based on the technique of investigation of a semi-structured interview. 12 coaches who belonged to the A.C.B. League were interviewed in seasons 2011/12, which aimed to determine the point of view that the coach has on the CM concept and thus could give a more practical approach based on their knowledge and experience about how to deal with the CM in basketball. The results of both studies agree on the importance of the CM on the final outcome of the game. Similarly, the concept itself is highly complex so the scientific view of the observation of the game is considered essential as well as the subjective perception the coach presents before the phenomenon, for which the psychological aspects of their characters (players and coaches) are crucial.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

El propósito de esta tesis es presentar una metodología para realizar análisis de la dinámica en pequeña señal y el comportamiento de sistemas de alimentación distribuidos de corriente continua (CC), formados por módulos comerciales. Para ello se hace uso de un método sencillo que indica los márgenes de estabilidad menos conservadores posibles mediante un solo número. Este índice es calculado en cada una de las interfaces que componen el sistema y puede usarse para obtener un índice global que indica la estabilidad del sistema global. De esta manera se posibilita la comparación de sistemas de alimentación distribuidos en términos de robustez. La interconexión de convertidores CC-CC entre ellos y con los filtros EMI necesarios puede originar interacciones no deseadas que dan lugar a la degradación del comportamiento de los convertidores, haciendo el sistema más propenso a inestabilidades. Esta diferencia en el comportamiento se debe a interacciones entre las impedancias de los diversos elementos del sistema. En la mayoría de los casos, los sistemas de alimentación distribuida están formados por módulos comerciales cuya estructura interna es desconocida. Por ello los análisis presentados en esta tesis se basan en medidas de la respuesta en frecuencia del convertidor que pueden realizarse desde los terminales de entrada y salida del mismo. Utilizando las medidas de las impedancias de entrada y salida de los elementos del sistema, se puede construir una función de sensibilidad que proporciona los márgenes de estabilidad de las diferentes interfaces. En esta tesis se utiliza el concepto del valor máximo de la función de sensibilidad (MPC por sus siglas en inglés) para indicar los márgenes de estabilidad como un único número. Una vez que la estabilidad de todas las interfaces del sistema se han evaluado individualmente, los índices obtenidos pueden combinarse para obtener un único número con el que comparar la estabilidad de diferentes sistemas. Igualmente se han analizado las posibles interacciones en la entrada y la salida de los convertidores CC-CC, obteniéndose expresiones analíticas con las que describir en detalle los acoplamientos generados en el sistema. Los estudios analíticos realizados se han validado experimentalmente a lo largo de la tesis. El análisis presentado en esta tesis se culmina con la obtención de un índice que condensa los márgenes de estabilidad menos conservativos. También se demuestra que la robustez del sistema está asegurada si las impedancias utilizadas en la función de sensibilidad se obtienen justamente en la entrada o la salida del subsistema que está siendo analizado. Por otra parte, la tesis presenta un conjunto de parámetros internos asimilados a impedancias, junto con sus expresiones analíticas, que permiten una explicación detallada de las interacciones en el sistema. Dichas expresiones analíticas pueden obtenerse bien mediante las funciones de transferencia analíticas si se conoce la estructura interna, o utilizando medidas en frecuencia o identificación de las mismas a través de la respuesta temporal del convertidor. De acuerdo a las metodologías presentadas en esta tesis se puede predecir la estabilidad y el comportamiento de sistemas compuestos básicamente por convertidores CC-CC y filtros, cuya estructura interna es desconocida. La predicción se basa en un índice que condensa la información de los márgenes de estabilidad y que permite la obtención de un indicador de la estabilidad global de todo el sistema, permitiendo la comparación de la estabilidad de diferentes arquitecturas de sistemas de alimentación distribuidos. ABSTRACT The purpose of this thesis is to present dynamic small-signal stability and performance analysis methodology for dc-distributed systems consisting of commercial power modules. Furthermore, the objective is to introduce simple method to state the least conservative margins for robust stability as a single number. In addition, an index characterizing the overall system stability is obtained, based on which different dc-distributed systems can be compared in terms of robustness. The interconnected systems are prone to impedance-based interactions which might lead to transient-performance degradation or even instability. These systems typically are constructed using commercial converters with unknown internal structure. Therefore, the analysis presented throughout this thesis is based on frequency responses measurable from the input and output terminals. The stability margins are stated utilizing a concept of maximum peak criteria, derived from the behavior of impedance-based sensitivity function that provides a single number to state robust stability. Using this concept, the stability information at every system interface is combined to a meaningful number to state the average robustness of the system. In addition, theoretical formulas are extracted to assess source and load side interactions in order to describe detailed couplings within the system. The presented theoretical analysis methodologies are experimentally validated throughout the thesis. In this thesis, according to the presented analysis, the least conservative stability margins are provided as a single number guaranteeing robustness. It is also shown that within the interconnected system the robust stability is ensured only if the impedance-based minor-loop gain is determined at the very input or output of each subsystem. Moreover, a complete set of impedance-type internal parameters as well as the formulas according to which the interaction sensitivity can be fully explained and analyzed, is provided. The given formulation can be utilized equally either based on measured frequency responses, time-domain identified internal parameters or extracted analytic transfer functions. Based on the analysis methodologies presented in this thesis, the stability and performance of interconnected systems consisting of converters with unknown internal structure, can be predicted. Moreover, the provided concept to assess the least conservative stability margins enables to obtain an index to state the overall robust stability of distributed power architecture and thus to compare different systems in terms of stability.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This study has been developed for the European Beach Volleyball Championship in 2005. The video-recorded analysis was held using Sportcode Pro v.8.5.2 software. The aim of study was to determine the types of serve used, depending on the time of the set in which they occur. Quantitative analysis with a sample of 10 players that make up 5 teams with a total of four meetings with a total of 327 serves analyzed. The serves were classified depending on the period which they occurred, the period being 1 (items 1 to 7), period 2 (from point 8 to 14) and period 3 (point 15 to 21). he statistical analysis was conducted using the statistical software SPSS 19, Chi-square test established significant differences between the different types of serve for period 1 and 2 (p<0.05), but no significant differences were established in the period 3 to floating serve and power jump (p>0.05). The results showed a decrease of using a serve with jump power at period 1 (89.7%) compared to the period 3 (27.3%), while the floating and floating serve jump respectively increase at period 1 (6.3% -4%) in the period 3 (23.4% -49.4%).

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We demonstrate a portable process for developing a triple bottom line model to measure the knowledge production performance of individual research centres. For the first time, this study also empirically illustrates how a fully units-invariant model of Data Envelopment Analysis (DEA) can be used to measure the relative efficiency of research centres by capturing the interaction amongst a common set of multiple inputs and outputs. This study is particularly timely given the increasing transparency required by governments and industries that fund research activities. The process highlights the links between organisational objectives, desired outcomes and outputs while the emerging performance model represents an executive managerial view. This study brings consistency to current measures that often rely on ratios and univariate analyses that are not otherwise conducive to relative performance analysis.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The purpose of this work is to establish the application of a fully automated microfluidic chip based protein separation assay in tear analysis. It is rapid, requires small sample volumes and is vastly superior to, and more convenient than, comparable conventional gel electrophoresis assays. The protein sizing chip technology was applied to three specific fields of analysis. Firstly tear samples were collected regularly from subjects establishing the baseline effects of tear stimulation, tear state and patient health. Secondly tear samples were taken from lens wearing eyes and thirdly the use of microfluidic technology was assessed as a means to investigate a novel area of tear analysis, which we have termed the 'tear envelope'. Utilising the Agilent 2100 Bioanalyzer in combination with the Protein 200 Plus LabChip kit, these studies investigated tear proteins in the range of 14-200 kDa. Particular attention was paid to the relative concentrations of lysozyme, tear lipocalin, secretory IgA (sIgA), IgG and lactoferrin, together with the overall tear electropherogram 'fingerprint'. Furthermore, whilst lens-tear interaction studies are generally thought of as an investigation into the effects of tears components on the contact lens material, i.e. deposition studies, this report addresses the reverse phenomenon-the effect of the lens, and particularly the newly inserted lens, on the tear fluid composition and dynamics. The use of microfluidic technology provides a significant advance in tear studies and should prove invaluable in tear diagnostics and contact lens performance analysis.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Inverters play key roles in connecting sustainable energy (SE) sources to the local loads and the ac grid. Although there has been a rapid expansion in the use of renewable sources in recent years, fundamental research, on the design of inverters that are specialized for use in these systems, is still needed. Recent advances in power electronics have led to proposing new topologies and switching patterns for single-stage power conversion, which are appropriate for SE sources and energy storage devices. The current source inverter (CSI) topology, along with a newly proposed switching pattern, is capable of converting the low dc voltage to the line ac in only one stage. Simple implementation and high reliability, together with the potential advantages of higher efficiency and lower cost, turns the so-called, single-stage boost inverter (SSBI), into a viable competitor to the existing SE-based power conversion technologies.^ The dynamic model is one of the most essential requirements for performance analysis and control design of any engineering system. Thus, in order to have satisfactory operation, it is necessary to derive a dynamic model for the SSBI system. However, because of the switching behavior and nonlinear elements involved, analysis of the SSBI is a complicated task.^ This research applies the state-space averaging technique to the SSBI to develop the state-space-averaged model of the SSBI under stand-alone and grid-connected modes of operation. Then, a small-signal model is derived by means of the perturbation and linearization method. An experimental hardware set-up, including a laboratory-scaled prototype SSBI, is built and the validity of the obtained models is verified through simulation and experiments. Finally, an eigenvalue sensitivity analysis is performed to investigate the stability and dynamic behavior of the SSBI system over a typical range of operation. ^

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this thesis, tool support is addressed for the combined disciplines of Model-based testing and performance testing. Model-based testing (MBT) utilizes abstract behavioral models to automate test generation, thus decreasing time and cost of test creation. MBT is a functional testing technique, thereby focusing on output, behavior, and functionality. Performance testing, however, is non-functional and is concerned with responsiveness and stability under various load conditions. MBPeT (Model-Based Performance evaluation Tool) is one such tool which utilizes probabilistic models, representing dynamic real-world user behavior patterns, to generate synthetic workload against a System Under Test and in turn carry out performance analysis based on key performance indicators (KPI). Developed at Åbo Akademi University, the MBPeT tool is currently comprised of a downloadable command-line based tool as well as a graphical user interface. The goal of this thesis project is two-fold: 1) to extend the existing MBPeT tool by deploying it as a web-based application, thereby removing the requirement of local installation, and 2) to design a user interface for this web application which will add new user interaction paradigms to the existing feature set of the tool. All phases of the MBPeT process will be realized via this single web deployment location including probabilistic model creation, test configurations, test session execution against a SUT with real-time monitoring of user configurable metric, and final test report generation and display. This web application (MBPeT Dashboard) is implemented with the Java programming language on top of the Vaadin framework for rich internet application development. The Vaadin framework handles the complicated web communications processes and front-end technologies, freeing developers to implement the business logic as well as the user interface in pure Java. A number of experiments are run in a case study environment to validate the functionality of the newly developed Dashboard application as well as the scalability of the solution implemented in handling multiple concurrent users. The results support a successful solution with regards to the functional and performance criteria defined, while improvements and optimizations are suggested to increase both of these factors.