874 resultados para Percutaneous fracture fixation
Mitigating surgical risk in patients undergoing hip arthroplasty for fractures of the proximal femur
Resumo:
Recently the National Patient Safety Agency in the United Kingdom published a report entitled "Mitigating surgical risk in patients undergoing hip arthroplasty for fractures of the proximal femur". A total of 26 deaths had been reported to them when cement was used at hemiarthroplasty between October 2003 and October 2008. This paper considers the evidence for using cement fixation of a hemiarthroplasty in the treatment of hip fractures.
Resumo:
This study presented the characteristics of the loading impact on the residuum of a transfemoral amputee fitted with an osseointegrated fixation during a fall for the first time. The maximum force (1,145 N = 132 % of the body weight and moments (153 N.m) were applied on the long and medio-lateral axes, respectively, approximately 0.85 s after heel contact of the prosthesis.
Resumo:
The fracture healing process is modulated by the mechanical environment created by imposed loads and motion between the bone fragments. Contact between the fragments obviously results in a significantly different stress and strain environment to a uniform fracture gap containing only soft tissue (e.g. haematoma). The assumption of the latter in existing computational models of the healing process will hence exaggerate the inter-fragmentary strain in many clinically-relevant cases. To address this issue, we introduce the concept of a contact zone that represents a variable degree of contact between cortices by the relative proportions of bone and soft tissue present. This is introduced as an initial condition in a two-dimensional iterative finite element model of a healing tibial fracture, in which material properties are defined by the volume fractions of each tissue present. The algorithm governing the formation of cartilage and bone in the fracture callus uses fuzzy logic rules based on strain energy density resulting from axial compression. The model predicts that increasing the degree of initial bone contact reduces the amount of callus formed (periosteal callus thickness 3.1mm without contact, down to 0.5mm with 10% bone in contact zone). This is consistent with the greater effective stiffness in the contact zone and hence, a smaller inter-fragmentary strain. These results demonstrate that the contact zone strategy reasonably simulates the differences in the healing sequence resulting from the closeness of reduction.
Resumo:
Computer aided joint replacement surgery has become very popular during recent years and is being done in increasing numbers all over the world. The accuracy of the system depends to a major extent, on accurate registration and immobility of the tracker attachment devices to the bone. This study was designed to asses the forces needed to displace the tracker attachment devices in the bone simulators. Bone simulators were used to maintain the uniformity of the bone structure during the study. The fixation devices tested were 3mm diameter self drilling, self tapping threaded pin, 4mm diameter self tapping cortical threaded pin, 5mm diameter self tapping cancellous threaded pin and a triplanar fixation device ‘ortholock’ used with three 3mm pins. All the devices were tested for pull out, translational and rotational forces in unicortical and bicortical fixation modes. Also tested was the normal bang strength and forces generated by leaning on the devices. The forces required to produce translation increased with the increasing diameter of the pins. These were 105N, 185N, and 225N for the unicortical fixations and 130N, 200N, 225N for the bicortical fixations for 3mm, 4mm and 5mm diameter pins respectively. The forces required to pull out the pins were 1475N, 1650N, 2050N for the unicortical, 1020N, 3044N and 3042N for the bicortical fixated 3mm, 4mm and 5mm diameter pins. The ortholock translational and pull out strength was tested to 900N and 920N respectively and still it did not fail. Rotatory forces required to displace the tracker on pins was to the magnitude of 30N before failure. The ortholock device had rotational forces applied up to 135N and still did not fail. The manual leaning forces and the sudden bang forces generated were of the magnitude of 210N and 150N respectively. The strength of the fixation pins increases with increasing diameter from three to five mm for the translational forces. There is no significant difference in pull out forces of four mm and five mm diameter pins though it is more that the three mm diameter pins. This is because of the failure of material at that stage rather than the fixation device. The rotatory forces required to displace the tracker are very small and much less that that can be produced by the surgeon or assistants in single pins. Although the ortholock device was tested to 135N in rotation without failing, one has to be very careful not to put any forces during the operation on the tracker devices to ensure the accuracy of the procedure.
Resumo:
This study established that the core principle underlying categorisation of activities have the potential to provide more comprehensive outcomes than the recognition of activities because it takes into consideration activities other than directional locomotion.
Resumo:
Vertebrplasty involved injecting cement into a fractured vertebra to provide stabilisation. There is clinical evidence to suggest however that vertebroplasty may be assocated with a higher risk of adjacent vertebral fracture; which may be due to the change in material properties of the post-procedure vertebra modifying the transmission of mechanical stresses to adjacent vertebrae.
Resumo:
The purpose of this study was to characterise the functional outcome of 12 transfemoral amputees fitted with osseointegrated fixation using temporal gait characteristics. The objectives were (A) to present the cadence, duration of gait cycle, support and swing phases with an emphasis on the stride-to-stride and participant-to-participant variability, and (B) to compare these temporal variables with normative data extracted from the literature focusing on transfemoral amputees fitted with a socket and able-bodied participants. The temporal variables were extracted from the load applied on the residuum during straight level walking, which was collected at 200 Hz by a transducer. A total of 613 strides were assessed. The cadence (46±4 strides/min), the duration of the gait cycle (1.29±0.11 s), support (0.73±0.07 s, 57±3% of CG) and swing (0.56±0.07 s, 43±3% of GC) phases of the participants were 2% quicker, 3%, 6% shorter and 1% longer than transfemoral amputees using a socket as well as 11% slower, 9%, 6% and 13% longer than able-bodied, respectively. All combined, the results indicated that the fitting of an osseointegrated fixation has enabled this group of amputees to restore their locomotion with a highly functional level. Further longitudinal and cross-sectional studies would be required to confirm these outcomes. Nonetheless, the data presented can be used as benchmark for future comparisons. It can also be used as input in generic algorithms using templates of patterns of loading to recognise activities of daily living and to detect falls.
Resumo:
The purpose of this proof-of-concept study was to determine the relevance of direct measurements to monitor the load applied on the osseointegrated fixation of transfemoral amputees during static load bearing exercises. The objectives were (A) to introduce an apparatus using a three-dimensional load transducer, (B) to present a range of derived information relevant to clinicians, (C) to report on the outcomes of a pilot study and (D) to compare the measurements from the transducer with those from the current method using a weighing scale. One transfemoral amputee fitted with an osseointegrated implant was asked to apply 10 kg, 20 kg, 40 kg and 80 kg on the fixation, using self-monitoring with the weighing scale. The loading was directly measured with a portable kinetic system including a six-channel transducer, external interface circuitry and a laptop. As the load prescribed increased from 10 kg to 80 kg, the forces and moments applied on and around the antero-posterior axis increased by 4 fold anteriorly and 14 fold medially, respectively. The forces and moments applied on and around the medio-lateral axis increased by 9 fold laterally and 16 fold from anterior to posterior, respectively. The long axis of the fixation was overloaded and underloaded in 17 % and 83 % of the trials, respectively, by up to ±10 %. This proof-of-concept study presents an apparatus that can be used by clinicians facing the challenge of improving basic knowledge on osseointegration, for the design of equipment for load bearing exercises and for rehabilitation programs.
Resumo:
Falling represents a health risk for lower limb amputees fitted with an osseointegrated fixation mainly because of the potential damage to the fixation. The purpose of this study was to characterise a real forward fall that occurred inadvertently to a transfemoral amputee fitted with an osseointegrated fixation while attending a gait measurement session to assess the load applied on the residuum. The objective was to analyse the load applied on the fixation with an emphasis on the sequence of events, the pattern and the magnitude of the forces and moments. The load was measured directly at 200 Hz using a six-channel transducer. Complementary video footage was also studied. The fall was divided into four phases: loading (240 ms), descent (620 ms), impact (365 ms) and recovery (2495 ms). The main impact forces and moments occurred 870 ms and 915 ms after the heel contact, and corresponded to 133 %BW and 17 %BWm, or 1.2 and 11.2 times the maximum forces and moments applied during the previous steps of the participant, respectively. This study provided key information to engineers and clinicians facing the challenge to design equipment, and rehabilitation and exercise programs to restore safely the locomotion of lower limb amputees.
Resumo:
Background and purpose Our aim was to prove in an animal model that the use of HA paste at the cement-bone interface in the acetabulum would improve fixation. We examined, in sheep, the effect of interposing a layer of hydroxyapatite cement around the periphery of a polyethylene socket prior to fixing it using polymethylemethacrylate (PMMA). Methods We made a randomized study involving 22 sheep to test whether the application of BoneSource hydroxyapatite material to the surface of the ovine acetabulum prior to cementing a polyethylene cup at hip arthroplasty improved the fixation and the nature of the interface. We studied the gross radiographical appearance of the implant-bone interface and the histological appearance at the interface. Results There were more radiolucencies evident in the control group. Histologically, only sheep randomized into the BoneSource group exhibited a fully osseointegrated interface. Use of the hydroxyapatite material did not confer any detrimental effects. In some cases the material appeared to have been fully resorbed. When the material was evident on histological section, it was incorporated into an osseointegrated interface. There was no giant cell reaction present in any case. There was no evidence of migration of BoneSource to the articulation. Interpretation The application of HA material prior to cementation of a socket produced an improved interface. The technique may be useful in man with to extend the longevity of the cemented implant by protecting the socket interface from the effect of hydrodynamic fluid flow and particulate debris.
Resumo:
Fracture behavior of Cu-Ni laminate composites has been investigated by tensile testing. It was found that as the individual layer thickness decreases from 100 to 20nm, the resultant fracture angle of the Cu-Ni laminate changes from 72 degrees to 50 degrees. Cross-sectional observations reveal that the fracture of the Ni layers transforms from opening to shear mode as the layer thickness decreases while that of the Cu layers keeps shear mode. Competition mechanisms were proposed to understand the variation in fracture mode of the metallic laminate composites associated with length scale.
Resumo:
Background The purpose of this study was to provide a detailed evaluation of adherence to nutrition supplements by patients with a lower limb fracture. Methods These descriptive data are from 49 nutritionally“ at-risk” patients aged 70+ years admitted to the hospital after a fall-related lower limb fracture and allocated to receive supplementation as part of a randomized, controlled trial. Supplementation commenced on day 7 and continued for 42 days. Prescribed volumes aimed to meet 45% of individually estimated theoretical energy requirements to meet the shortfall between literature estimates of energy intake and requirements. The supplement was administered by nursing staff on medication rounds in the acute or residential care settings and supervised through thrice-weekly home visits postdischarge. Results Median daily percent of the prescribed volume of nutrition supplement consumed averaged over the 42 days was 67% (interquartile range [IQR], 31–89, n = 49). There was no difference in adherence for gender, accommodation, cognition, or whether the supplement was self-administered or supervised. Twenty-three participants took some supplement every day, and a further 12 missed <5 days. For these 35 “nonrefusers,” adherence was 82% (IQR, 65–93), and they lost on average 0.7% (SD, 4.0%) of baseline weight over the 6 weeks of supplementation compared with a loss of 5.5% (SD, 5.4%) in the “refusers” (n = 14, 29%), p = .003. Conclusions We achieved better volume and energy consumption than previous studies of hip fracture patients but still failed to meet target supplement volumes prescribed to meet 45% of theoretical energy requirements. Clinicians should consider alternative methods of feeding such as a nasogastric tube, particularly in those patients where adherence to oral nutrition supplements is poor and dietary intake alone is insufficient to meet estimated energy requirements.