989 resultados para Peak Fit Parameters


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The standard highway assignment model in the Florida Standard Urban Transportation Modeling Structure (FSUTMS) is based on the equilibrium traffic assignment method. This method involves running several iterations of all-or-nothing capacity-restraint assignment with an adjustment of travel time to reflect delays encountered in the associated iteration. The iterative link time adjustment process is accomplished through the Bureau of Public Roads (BPR) volume-delay equation. Since FSUTMS' traffic assignment procedure outputs daily volumes, and the input capacities are given in hourly volumes, it is necessary to convert the hourly capacities to their daily equivalents when computing the volume-to-capacity ratios used in the BPR function. The conversion is accomplished by dividing the hourly capacity by a factor called the peak-to-daily ratio, or referred to as CONFAC in FSUTMS. The ratio is computed as the highest hourly volume of a day divided by the corresponding total daily volume. ^ While several studies have indicated that CONFAC is a decreasing function of the level of congestion, a constant value is used for each facility type in the current version of FSUTMS. This ignores the different congestion level associated with each roadway and is believed to be one of the culprits of traffic assignment errors. Traffic counts data from across the state of Florida were used to calibrate CONFACs as a function of a congestion measure using the weighted least squares method. The calibrated functions were then implemented in FSUTMS through a procedure that takes advantage of the iterative nature of FSUTMS' equilibrium assignment method. ^ The assignment results based on constant and variable CONFACs were then compared against the ground counts for three selected networks. It was found that the accuracy from the two assignments was not significantly different, that the hypothesized improvement in assignment results from the variable CONFAC model was not empirically evident. It was recognized that many other factors beyond the scope and control of this study could contribute to this finding. It was recommended that further studies focus on the use of the variable CONFAC model with recalibrated parameters for the BPR function and/or with other forms of volume-delay functions. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the aim of analyzing the complex physical and biogeochemical interactions at high temporal and spatial resolution in the complex estuarine waters of Alfacs Bay, a beam attenuation-based approach was used as optical proxy of different biogeochemical variables. Thus, the dataset contains the attenuation proxies as well as laboratory results from the analysis of water samples, which were used to validate our approach. In addition, the major physical forcing in the Bay was also measured.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atomisation of an aqueous solution for tablet film coating is a complex process with multiple factors determining droplet formation and properties. The importance of droplet size for an efficient process and a high quality final product has been noted in the literature, with smaller droplets reported to produce smoother, more homogenous coatings whilst simultaneously avoiding the risk of damage through over-wetting of the tablet core. In this work the effect of droplet size on tablet film coat characteristics was investigated using X-ray microcomputed tomography (XμCT) and confocal laser scanning microscopy (CLSM). A quality by design approach utilising design of experiments (DOE) was used to optimise the conditions necessary for production of droplets at a small (20 μm) and large (70 μm) droplet size. Droplet size distribution was measured using real-time laser diffraction and the volume median diameter taken as a response. DOE yielded information on the relationship three critical process parameters: pump rate, atomisation pressure and coating-polymer concentration, had upon droplet size. The model generated was robust, scoring highly for model fit (R2 = 0.977), predictability (Q2 = 0.837), validity and reproducibility. Modelling confirmed that all parameters had either a linear or quadratic effect on droplet size and revealed an interaction between pump rate and atomisation pressure. Fluidised bed coating of tablet cores was performed with either small or large droplets followed by CLSM and XμCT imaging. Addition of commonly used contrast materials to the coating solution improved visualisation of the coating by XμCT, showing the coat as a discrete section of the overall tablet. Imaging provided qualitative and quantitative evidence revealing that smaller droplets formed thinner, more uniform and less porous film coats.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Low pO2 values have been measured in the perivitelline fluids (PVF) of marine animal eggs on several occasions, especially towards the end of development, when embryonic oxygen consumption is at its peak and the egg case acts as a massive barrier to diffusion. Several authors have therefore suggested that oxygen availability is the key factor leading to hatching. However, there have been no measurements of PVF pCO2 so far. This is surprising, as elevated pCO2 could also constitute a major abiotic stressor for the developing embryo. As a first attempt to fill this gap in knowledge, we measured pO2, pCO2 and pH in the PVF of late cephalopod (Sepia officinalis) eggs. We found linear relationships between embryo wet mass and pO2, pCO2 and pH. pO2 declined from >12 kPa to less than 5 kPa, while pCO2 increased from 0.13 to 0.41 kPa. In the absence of active accumulation of bicarbonate in the PVF, pH decreased from 7.7 to 7.2. Our study supports the idea that oxygen becomes limiting in cephalopod eggs towards the end of development; however, pCO2 and pH shift to levels that have caused significant physiological disturbances in other marine ectothermic animals. Future research needs to address the physiological adaptations that enable the embryo to cope with the adverse abiotic conditions in their egg environment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Study of biogeochemical processes in waters and sediments of the Chukchi Sea in August 2004 revealed atypical maxima of biogenic element (N, P, and Si) concentrations and rate of microbial sulfate reduction in the surface layer (0-3 cm) of marine sediments. The C/N/P ratio in organic matter (OM) of this layer does not fit the Redfield-Richards stoichiometric model. Specific features of biogeochemical processes in the sea are likely related to the complex dynamics of water, high primary produc¬tivity (110-1400 mg C/m**2/day), low depth of the basin (<50 m for 60% of the water area), reduced food chain due to low population of zooplankton, high density of zoobenthos (up to 4230 g/m**2), and high activity of microbial processes. Drastic decrease in concentrations of biogenic elements, iodine, total alkalinity, and population of microorganisms beneath the 0-3 cm layer testify to large-scale OM decay at the water-seafloor barrier. Our original experimental data support high annual rate of OM mineralization at the bottom of the Chukchi Sea.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We present DES14X3taz, a new hydrogen-poor superluminous supernova (SLSN-I) discovered by the Dark Energy Survey (DES) supernova program, with additional photometric data provided by the Survey Using DECam for Superluminous Supernovae. Spectra obtained using Optical System for Imaging and low-Intermediate-Resolution Integrated Spectroscopy on the Gran Telescopio CANARIAS show DES14X3taz is an SLSN-I at z = 0.608. Multi-color photometry reveals a double-peaked light curve: a blue and relatively bright initial peak that fades rapidly prior to the slower rise of the main light curve. Our multi-color photometry allows us, for the first time, to show that the initial peak cools from 22,000 to 8000 K over 15 rest-frame days, and is faster and brighter than any published core-collapse supernova, reaching 30% of the bolometric luminosity of the main peak. No physical 56Ni-powered model can fit this initial peak. We show that a shock-cooling model followed by a magnetar driving the second phase of the light curve can adequately explain the entire light curve of DES14X3taz. Models involving the shock-cooling of extended circumstellar material at a distance of 400  are preferred over the cooling of shock-heated surface layers of a stellar envelope. We compare DES14X3taz to the few double-peaked SLSN-I events in the literature. Although the rise times and characteristics of these initial peaks differ, there exists the tantalizing possibility that they can be explained by one physical interpretation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the spirometry and respiratory static pressures in 17 young women, twice a week for three successive ovulatory menstrual cycles to determine if such variables changed across the menstrual, follicular, periovulatory, early-tomid luteal and late luteal phases. The factors phases of menstrual cycle and individual cycles had no significant effect on the spirometry variables except for peak expiratory flow (PEF) and respiratory static pressures. Significant weak positive correlations were found between the progesterone:estradiol ratio and PEF and between estrogen and tidal volume (r = 0.37), inspiratory time (r = 0.22), expiratory time (r = 0.19), maximal inspiratory pressure (r = 0.25) and maximal expiratory pressure (r = 0.20) and for progesterone and maximal inspiratory pressure (r = 0.32) during the early-to-mid luteal phase. Although most parameters of the spirometry results did not change during the menstrual cycle, the correlations observed between sexual hormones and respiratory control variables suggest a positive influence of sexual female hormones controlling the thoracic pump muscles in the luteal phase

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work presents a computational, called MOMENTS, code developed to be used in process control to determine a characteristic transfer function to industrial units when radiotracer techniques were been applied to study the unit´s performance. The methodology is based on the measuring the residence time distribution function (RTD) and calculate the first and second temporal moments of the tracer data obtained by two scintillators detectors NaI positioned to register a complete tracer movement inside the unit. Non linear regression technique has been used to fit various mathematical models and a statistical test was used to select the best result to the transfer function. Using the code MOMENTS, twelve different models can be used to fit a curve and calculate technical parameters to the unit.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluated the spirometry and respiratory static pressures in 17 young women, twice a week for three successive ovulatory menstrual cycles to determine if such variables changed across the menstrual, follicular, periovulatory, early-tomid luteal and late luteal phases. The factors phases of menstrual cycle and individual cycles had no significant effect on the spirometry variables except for peak expiratory flow (PEF) and respiratory static pressures. Significant weak positive correlations were found between the progesterone:estradiol ratio and PEF and between estrogen and tidal volume (r = 0.37), inspiratory time (r = 0.22), expiratory time (r = 0.19), maximal inspiratory pressure (r = 0.25) and maximal expiratory pressure (r = 0.20) and for progesterone and maximal inspiratory pressure (r = 0.32) during the early-to-mid luteal phase. Although most parameters of the spirometry results did not change during the menstrual cycle, the correlations observed between sexual hormones and respiratory control variables suggest a positive influence of sexual female hormones controlling the thoracic pump muscles in the luteal phase

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The flow rates of drying and nebulizing gas, heat block and desolvation line temperatures and interface voltage are potential electrospray ionization parameters as they may enhance sensitivity of the mass spectrometer. The conditions that give higher sensitivity of 13 pharmaceuticals were explored. First, Plackett-Burman design was implemented to screen significant factors, and it was concluded that interface voltage and nebulizing gas flow were the only factors that influence the intensity signal for all pharmaceuticals. This fractionated factorial design was projected to set a full 2(2) factorial design with center points. The lack-of-fit test proved to be significant. Then, a central composite face-centered design was conducted. Finally, a stepwise multiple linear regression and subsequently an optimization problem solving were carried out. Two main drug clusters were found concerning the signal intensities of all runs of the augmented factorial design. p-Aminophenol, salicylic acid, and nimesulide constitute one cluster as a result of showing much higher sensitivity than the remaining drugs. The other cluster is more homogeneous with some sub-clusters comprising one pharmaceutical and its respective metabolite. It was observed that instrumental signal increased when both significant factors increased with maximum signal occurring when both codified factors are set at level +1. It was also found that, for most of the pharmaceuticals, interface voltage influences the intensity of the instrument more than the nebulizing gas flowrate. The only exceptions refer to nimesulide where the relative importance of the factors is reversed and still salicylic acid where both factors equally influence the instrumental signal. Graphical Abstract ᅟ.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Au cours des vingt dernières années, l’anesthésie régionale est devenue, autant en médecine vétérinaire qu’humaine, un outil essentiel à l’élaboration de protocoles analgésiques péri-opératoires. Parmi l’éventail de techniques mises au point en anesthésie canine, le bloc paravertébral du plexus vertébral (PBPB) et sa version modifiée sont d’un grand intérêt pour toute procédure du membre thoracique, dans sa portion proximale. Toutefois, l’essentiel des données publiées à ce jour provient d’études colorimétriques, sans évaluation clinique, et peu d’information est disponible sur les techniques de localisation nerveuse envisageables à ce site. Notre étude visait à décrire une approche échoguidée du PBPB modifié, puis à caractériser ses paramètres pharmacocinétiques et pharmacodynamiques après administration de lidocaïne (LI) ou lidocaïne adrénalinée (LA). Huit chiens ont été inclus dans un protocole prospectif, randomisé, en aveugle et croisé, réparti sur trois périodes. L’impact pharmacodynamique du bloc effectué avec LI ou LA a été évalué régulièrement pour 180 min suivant son exécution. Le traitement à l’adrénaline n’a pas démontré d’impact significatif (P = 0,845) sur la durée du bloc sensitif, tel qu’évalué par un stimulus douloureux mécanique appliqué aux dermatomes ciblés. À l’opposé, l’atteinte proprioceptive évaluée par la démarche a été trouvée prolongée (P = 0,027) et le bloc moteur mesuré par le pic de force verticale (PVF) au trot sur la plaque de force s’est avéré plus marqué (PVF réduit; P = 0,007) sous LA. À l’arrêt comme au trot, le nadir de la courbe PVF-temps a été trouvé retardé (P < 0,005) et la pente ascendante de retour aux valeurs normales adoucie (P = 0,005). Parallèlement aux évaluations cliniques, des échantillons plasmatiques ont été collectés régulièrement afin de quantifier et décrire le devenir pharmacocinétique de la lidocaïne. Parmi les trois élaborés, un modèle bi-compartimental doté d’une double absorption asynchrone d’ordre zéro a finalement été sélectionné et appliqué aux données expérimentales. Sous LA, la Cmax a été trouvée significativement diminuée (P < 0,001), les phases d’absorption prolongées [P < 0,020 (Dur1) et P < 0,001 (Dur2)] et leurs constantes réduites [P = 0,046(k01) et P < 0,001 (k02)], le tout en concordance avec les effets proprioceptifs et moteurs rapportés. Bien que l’extrapolation du dosage soit maintenant théoriquement envisageable à partir du modèle mis en lumière ici, des études supplémentaires sont encore nécessaires afin d’établir un protocole de PBPB d’intérêt clinique. L’analyse sur plaque de force pourrait alors devenir un outil de choix pour évaluer l’efficacité du bloc dans un cadre expérimental.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Au cours des vingt dernières années, l’anesthésie régionale est devenue, autant en médecine vétérinaire qu’humaine, un outil essentiel à l’élaboration de protocoles analgésiques péri-opératoires. Parmi l’éventail de techniques mises au point en anesthésie canine, le bloc paravertébral du plexus vertébral (PBPB) et sa version modifiée sont d’un grand intérêt pour toute procédure du membre thoracique, dans sa portion proximale. Toutefois, l’essentiel des données publiées à ce jour provient d’études colorimétriques, sans évaluation clinique, et peu d’information est disponible sur les techniques de localisation nerveuse envisageables à ce site. Notre étude visait à décrire une approche échoguidée du PBPB modifié, puis à caractériser ses paramètres pharmacocinétiques et pharmacodynamiques après administration de lidocaïne (LI) ou lidocaïne adrénalinée (LA). Huit chiens ont été inclus dans un protocole prospectif, randomisé, en aveugle et croisé, réparti sur trois périodes. L’impact pharmacodynamique du bloc effectué avec LI ou LA a été évalué régulièrement pour 180 min suivant son exécution. Le traitement à l’adrénaline n’a pas démontré d’impact significatif (P = 0,845) sur la durée du bloc sensitif, tel qu’évalué par un stimulus douloureux mécanique appliqué aux dermatomes ciblés. À l’opposé, l’atteinte proprioceptive évaluée par la démarche a été trouvée prolongée (P = 0,027) et le bloc moteur mesuré par le pic de force verticale (PVF) au trot sur la plaque de force s’est avéré plus marqué (PVF réduit; P = 0,007) sous LA. À l’arrêt comme au trot, le nadir de la courbe PVF-temps a été trouvé retardé (P < 0,005) et la pente ascendante de retour aux valeurs normales adoucie (P = 0,005). Parallèlement aux évaluations cliniques, des échantillons plasmatiques ont été collectés régulièrement afin de quantifier et décrire le devenir pharmacocinétique de la lidocaïne. Parmi les trois élaborés, un modèle bi-compartimental doté d’une double absorption asynchrone d’ordre zéro a finalement été sélectionné et appliqué aux données expérimentales. Sous LA, la Cmax a été trouvée significativement diminuée (P < 0,001), les phases d’absorption prolongées [P < 0,020 (Dur1) et P < 0,001 (Dur2)] et leurs constantes réduites [P = 0,046(k01) et P < 0,001 (k02)], le tout en concordance avec les effets proprioceptifs et moteurs rapportés. Bien que l’extrapolation du dosage soit maintenant théoriquement envisageable à partir du modèle mis en lumière ici, des études supplémentaires sont encore nécessaires afin d’établir un protocole de PBPB d’intérêt clinique. L’analyse sur plaque de force pourrait alors devenir un outil de choix pour évaluer l’efficacité du bloc dans un cadre expérimental.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The paper states an introduction, description and implementation of a PV cell under the variation of parameters. Analysis and observation of a different parameters variation of a PV cell are discussed here. To obtain the model for the purpose of analyzing an equivalent circuit with the consisting parameters a photo current source, a series resistor, a shunt resistor and a diode is used. The fundamental equation of PV cell is used to study the model and to analyze and best fit observation data. The model can be used in measuring and understanding the behaviour of photovoltaic cells for certain changes in PV cell parameters. A numerical method is used to analyze the parameters sensitivity of the model to achieve the expected result and to understand the deviation of changes in different parameters situation at various conditions respectively. The ideal parameters are used to study the models behaviour. It is also compared the behaviour of current-voltage and power-voltage by comparing with produced maximum power point though it is a challenge to optimize the output with real time simulation. The whole working process is also discussed and an experimental work is also done to get the closure and insight about the produced model and to decide upon the validity of the discussed model.