956 resultados para Patient monitoring


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Visual results in treating neovascular age-related macular degeneration (AMD) using intravitreal injected anti-VEGF (IVT) clearly depend on injection frequency. Regarding to the European approval Ranibizumab has to be used only in cases of recurrent visual loss after the loading phase. In contrast monthly treatment--as also provided in the ANCHOR and MARINA studies--is generally allowed in Switzerland. However, it is commonly tried to reduce the injection frequency because of the particular cost situation in all health systems and of cause also due to the necessary strict monitoring and reinjection regimes, which raise management problems with increasing patient numbers. In this article the special treatment regimes of our University Eye Hospital is presented, in which a reduced injection frequency basically leads to the same increased and stable visual results as in ANCHOR and MARINA; however, needing significantly more injections as generally provided in other countries of Europe. The main focus for achieving this in a large number of patients is placed on re-structuring our outpatient flow for IVT patients with particular emphasis on patient separation and standardisation of treatment steps leading to significantly reduced time consumption per patient. Measurements of timing and patient satisfaction before and after restructuring underline its importance in order to be able to treat more patients at a high quality even in the future. The exceptional importance of spectral domain OCT measurements as the most important criterium for indicating re-treatment is illustrated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to compare tooth surface pH after drinking orange juice or water in 39 patients with dental erosion and in 17 controls. The following investigations were carried out: measurement of pH values on selected tooth surfaces after ingestion of orange juice followed by ingestion of water (acid clearance), measurement of salivary flow rate and buffering capacity. Compared with the controls, patients with erosion showed significantly greater decreases in pH after drinking orange juice, and the pH stayed lower for a longer period of time (p < 0.05). Saliva parameters showed no significant differences between the two patient groups except for a lower buffering capacity at pH 5.5 in the erosion group.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Indications for oral anticoagulation (OAC) have increased in recent years. OAC requires frequent monitoring of the prothrombin time to keep the intensity within the therapeutic range and to minimise the risk for complications. Patient self-management (PSM) has been found to improve the quality of OAC. The present study aimed to investigate the first 330 patients performing PSM in Switzerland. A questionnaire was sent to all patients who followed a teaching program for PSM of OAC between 1998 and 2003. Moreover, family physicians were contacted and/or discharge letters were obtained from the hospitals or the treating physicians. During the study period 13 patients died. Out of the 300 patients providing information 254 (85%) still perform PSM. At least one INR determination per two weeks was done by 74% of the patients and 25% performed at least one INR measurement every 15-30 days. The median time spent within the individual INR target range was 72%. No thromboembolic complications occurred, however, among the 13 patients who died, 1 had myocardial infarction and 6 died of heart failure. When counting these events as arterial thromboembolic complications the frequency was 0.6 (95% CI: 0.3-1.3) per 100 patient-years. The frequency of major bleeding was 0.6 (95% CI: 0.2-1.3) per 100 patient-years. We conclude from this study investigating a real-world patient collective that PSM is suitable and safe for the patients identified by their family physicians and successfully trained by our training centre.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To compare the effects on heart rate (HR), on left ventricular (LV) or arterial pressures, and the general safety of a non-ionic low-osmolar contrast medium (CM) and a non-ionic iso-osmolar CM in patients undergoing cardiac angiography (CA) or peripheral intra-arterial digital subtraction angiography (IA-DSA). MATERIALS AND METHODS: Two double-blind, randomized studies were conducted in 216 patients who underwent CA (n=120) or peripheral IA-DSA (n=96). Patients referred for CA received a low-osmolar monomeric CM (iomeprol-350, n=60) or an iso-osmolar dimeric CM (iodixanol-320; n=60). HR and LV peak systolic and end-diastolic pressures were determined before and after the first injection during left and right coronary arteriography and left ventriculography. Monitoring for all types of adverse event (AE) was performed for 24 h following the procedure. t-tests were performed to compare CM for effects on HR. Patients referred for IA-DSA received iomeprol-300 (n=49) or iodixanol-320 (n=47). HR and arterial blood pressure (BP) were evaluated before and after the first 4 injections. Monitoring for AE was performed for 4 h following the procedure. Repeated-measures ANOVA was used to compare mean HR changes across the first 4 injections, whereas changes after the first injection were compared using t-tests. RESULTS: No significant differences were noted between iomeprol and iodixanol in terms of mean changes in HR during left coronary arteriography (p=0.8), right coronary arteriography (p=0.9), and left ventriculography (p=0.8). In patients undergoing IA-DSA, no differences between CM were noted for effects on mean HR after the first injection (p=0.6) or across the first 4 injections (p=0.2). No significant differences (p>0.05) were noted in terms of effects on arterial BP in either study or on LV pressures in patients undergoing CA. Non-serious AE considered possibly CM-related (primarily headache and events affecting the cardiovascular and digestive systems) were reported more frequently by patients undergoing CA and more frequently after iodixanol (14/60 [23.3%] and 2/47 [4.3%]; CA and IA-DSA, respectively) than iomeprol (10/60 [16.7%] and 1/49 [2%], respectively). CONCLUSIONS: Iomeprol and iodixanol are safe and have equally negligible effects on HR and LV pressures or arterial BP during and after selective intra-cardiac injection and peripheral IA-DSA. CLINICAL APPLICATION: Iomeprol and iodixanol are safe and equally well tolerated with regard to cardiac rhythm and clinical preference should be based on diagnostic image quality alone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: The incidence of bloodstream infection (BSI) in extracorporeal life support (ECLS) is reported between 0.9 and 19.5%. In January 2006, the Extracorporeal Life Support Organization (ELSO) reported an overall incidence of 8.78% distributed as follows: respiratory: 6.5% (neonatal), 20.8% (pediatric); cardiac: 8.2% (neonatal) and 12.6% (pediatric). METHOD: At BC Children's Hospital (BCCH) daily surveillance blood cultures (BC) are performed and antibiotic prophylaxis is not routinely recommended. Positive BC (BC+) were reviewed, including resistance profiles, collection time of BC+, time to positivity and mortality. White blood cell count, absolute neutrophile count, immature/total ratio, platelet count, fibrinogen and lactate were analyzed 48, 24 and 0 h prior to BSI. A univariate linear regression analysis was performed. RESULTS: From 1999 to 2005, 89 patients underwent ECLS. After exclusion, 84 patients were reviewed. The attack rate was 22.6% (19 BSI) and 13.1% after exclusion of coagulase-negative staphylococci (n = 8). BSI patients were significantly longer on ECLS (157 h) compared to the no-BSI group (127 h, 95% CI: 106-148). Six BSI patients died on ECLS (35%; 4 congenital diaphragmatic hernias, 1 hypoplastic left heart syndrome and 1 after a tetralogy repair). BCCH survival on ECLS was 71 and 58% at discharge, which is comparable to previous reports. No patient died primarily because of BSI. No BSI predictor was identified, although lactate may show a decreasing trend before BSI (P = 0.102). CONCLUSION: Compared with ELSO, the studied BSI incidence was higher with a comparable mortality. We speculate that our BSI rate is explained by underreporting of "contaminants" in the literature, the use of broad-spectrum antibiotic prophylaxis and a higher yield with daily monitoring BC. We support daily surveillance blood cultures as an alternative to antibiotic prophylaxis in the management of patients on ECLS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gastro-oesophageal reflux disease (GERD) is a highly prevalent condition in Western countries leading to millions of outpatient visits per year. GERD symptoms including heartburn, regurgitation and chest pain are caused by reflux of gastric content in the oesophagus even in the absence of endoscopically visible mucosal lesions. Several procedures are used to identify gastro-oesophageal reflux, the clinically widely used are: conventional (catheter-based) pH monitoring, wireless oesophageal pH monitoring (Bravo), bilirubin monitoring (Bilitec), and combined multichannel intraluminal impedance-pH monitoring (MII-pH). Each technique has strengths and limitations of which clinicians and investigators should be aware when deciding which to choose in a particular patient. Important is the ability to quantify gastro-oesophageal reflux and evaluate the relationship between symptoms and reflux episodes. The present review summarises the technical aspects in performing and interpreting esophageal reflux monitoring procedures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. METHODS: ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP by manual assessment. Interobserver variability was determined. Manual dPP assessments were used for comparison with automated measurements. To estimate the importance of the PAW signal, RV(slim) measurements were compared with RV measurements. RESULTS: For the 24 patients, 174 measurements (6-10 per patient) were recorded. Six observers assessed dPP manually in the first 8 patients (10-min interval, 53 measurements); no interobserver variability occurred using a computer-assisted method. Bland-Altman analysis showed acceptable bias and limits of agreement of the 2 automated methods compared with the manual method (RV: -0.33% +/- 8.72% and RV(slim): -1.74% +/- 7.97%). The difference between RV measurements and RV(slim) measurements is small (bias -1.05%, limits of agreement 5.67%). CONCLUSIONS: Measurements of the automated device are comparable with measurements obtained by human observers, who use a computer-assisted method. The importance of the PAW signal is questionable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper is focused on the integration of state-of-the-art technologies in the fields of telecommunications, simulation algorithms, and data mining in order to develop a Type 1 diabetes patient's semi to fully-automated monitoring and management system. The main components of the system are a glucose measurement device, an insulin delivery system (insulin injection or insulin pumps), a mobile phone for the GPRS network, and a PDA or laptop for the Internet. In the medical environment, appropriate infrastructure for storage, analysis and visualizing of patients' data has been implemented to facilitate treatment design by health care experts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Premature babies require supplementation with calcium and phosphorus to prevent metabolic bone disease of prematurity. To guide mineral supplementation, two methods of monitoring urinary excretion of calcium and phosphorus are used: urinary calcium or phosphorus concentration and calcium/creatinine or phosphorus/creatinine ratios. We compare these two methods in regards to their agreement on the need for mineral supplementation. METHODS: Retrospective chart review of 230 premature babies with birthweight <1500 g, undergoing screening of urinary spot samples from day 21 of life and fortnightly thereafter. Hypothetical cut-off values for urine calcium or phosphorus concentration (1 mmol/l) and urine calcium/creatinine ratio (0.5 mol/mol) or phosphorus/creatinine ratio (4 mol/mol) were applied to the sample results. The agreement on whether or not to supplement the respective minerals based on the results with the two methods was compared. Multivariate general linear models sought to identify patient characteristic to predict disagreeing results. RESULTS: 24.8% of cases disagreed on the indication for calcium supplementation, 8.8% for phosphorus. Total daily calcium intake was the only patient characteristic associated with discordant results. CONCLUSIONS: With the intention to supplement the respective mineral, comparison of urinary mineral concentration with mineral/creatinine ratio is moderate for Calcium and good for Phosphorus. The results do not allow to identify superiority of either method on the decision which babies require calcium and/or phosphorus supplements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The development of a robust assay based on MEKC for cefepime in human serum and plasma with internal quality assurance is reported. Sample preparation comprises protein precipitation in the presence of SDS at pH 4.5. This is a gentle approach for which decomposition of cefepime during sample handling is negligible. After hydrodynamic sample injection of the supernatant, analysis occurs in a phosphate/borate buffer at pH 9.1 with 75 mM SDS using normal polarity and analyte detection at 257 nm. The MEKC run time interval and throughput are about 5 min and seven samples per hour, respectively. The calibration range for cefepime is 1-60 μg/mL, with 1 μg/mL being the LOQ. The performance of the assay with multilevel internal calibration was assessed with calibration and control samples. The assay is shown to be simple, inexpensive, reproducible, and robust. It was applied to determine cefepime levels in the sera of critically ill patients and to assess the instability of cefepime in patient and control samples. Our data revealed that serum containing cefepime can be stored at -20°C for a short time, whereas for long-term storage, samples have to be kept at -70°C.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pre-operative assessment and surgical management of patients with non-lesional extratemporal epilepsy remain challenging due to a lack of precise localisation of the epileptic zone. In most cases, invasive recording with depth or subdural electrodes is required. Here, we describe the case of 6.5-year-old girl who underwent comprehensive non-invasive phase I video-EEG investigation for drug-resistant epilepsy, including electric source and nuclear imaging. Left operculo-insular epilepsy was diagnosed. Post-operatively, she developed aphasia which resolved within one year, corroborating the notion of enhanced language plasticity in children. The patient remained seizure-free for more than three years.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report on oxygenation changes noninvasively recorded by multichannel continuous-wave near infrared spectroscopy (CW-NIRS) during endovascular neuroradiologic interventions requiring temporary balloon occlusion of arteries supplying the cerebral circulation. Digital subtraction angiography (DSA) provides reference data on the site, timing, and effectiveness of the flow stagnation as well as on the amount and direction of collateral circulation. This setting allows us to relate CW-NIRS findings to brain specific perfusion changes. We focused our analysis on the transition from normal perfusion to vessel occlusion, i.e., before hypoxia becomes clinically apparent. The localization of the maximal response correlated either with the core (occlusion of the middle cerebral artery) or with the watershed areas (occlusion of the internal carotid artery) of the respective vascular territories. In one patient with clinically and angiographically confirmed insufficient collateral flow during carotid artery occlusion, the total hemoglobin concentration became significantly asymmetric, with decreased values in the ipsilateral watershed area and contralaterally increased values. Multichannel CW-NIRS monitoring might serve as an objective and early predictive marker of critical perfusion changes during interventions-to prevent hypoxic damage of the brain. It also might provide valuable human reference data on oxygenation changes as they typically occur during acute stroke.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Quantitative imaging with 18F-FDG PET/CT has the potential to provide an in vivo assessment of response to radiotherapy (RT). However, comparing tissue tracer uptake in longitudinal studies is often confounded by variations in patient setup and potential treatment induced gross anatomic changes. These variations make true response monitoring for the same anatomic volume a challenge, not only for tumors, but also for normal organs-at-risk (OAR). The central hypothesis of this study is that more accurate image registration will lead to improved quantitation of tissue response to RT with 18F-FDG PET/CT. Employing an in-house developed “demons” based deformable image registration algorithm, pre-RT tumor and parotid gland volumes can be more accurately mapped to serial functional images. To test the hypothesis, specific aim 1 was designed to analyze whether deformably mapping tumor volumes rather than aligning to bony structures leads to superior tumor response assessment. We found that deformable mapping of the most metabolically avid regions improved response prediction (P<0.05). The positive predictive power for residual disease was 63% compared to 50% for contrast enhanced post-RT CT. Specific aim 2 was designed to use parotid gland standardized uptake value (SUV) as an objective imaging biomarker for salivary toxicity. We found that relative change in parotid gland SUV correlated strongly with salivary toxicity as defined by the RTOG/EORTC late effects analytic scale (Spearman’s ρ = -0.96, P<0.01). Finally, the goal of specific aim 3 was to create a phenomenological dose-SUV response model for the human parotid glands. Utilizing only baseline metabolic function and the planned dose distribution, predicting parotid SUV change or salivary toxicity, based upon specific aim 2, became possible. We found that the predicted and observed parotid SUV relative changes were significantly correlated (Spearman’s ρ = 0.94, P<0.01). The application of deformable image registration to quantitative treatment response monitoring with 18F-FDG PET/CT could have a profound impact on patient management. Accurate and early identification of residual disease may allow for more timely intervention, while the ability to quantify and predict toxicity of normal OAR might permit individualized refinement of radiation treatment plan designs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Chemotherapies of solid tumors commonly include 5-fluorouracil (5-FU). With standard doses of 5-FU, substantial inter-patient variability has been observed in exposure levels and treatment response. Recently, improved outcomes in colorectal cancer patients due to pharmacokinetically guided 5-FU dosing were reported. We aimed at establishing a rapid and sensitive method for monitoring 5-FU plasma levels in cancer patients in our routine clinical practice. METHODS: Performance of the Saladax My5-FU™ immunoassay was evaluated on the Roche Cobas® Integra 800 analyzer. Subsequently, 5-FU concentrations of 247 clinical plasma samples obtained with this assay were compared to the results obtained by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and other commonly used clinical analyzers (Olympus AU400, Roche Cobas c6000, and Thermo Fisher CDx90). RESULTS: The My-FU assay was successfully validated on the Cobas Integra 800 analyzer in terms of linearity, precision, accuracy, recovery, interference, sample carryover, and dilution integrity. Method comparison between the Cobas Integra 800 and LC-MS/MS revealed a proportional bias of 7% towards higher values measured with the My5-FU assay. However, when the Cobas Integra 800 was compared to three other clinical analyzers in addition to LC-MS/MS including 50 samples representing the typical clinical range of 5-FU plasma concentrations, only a small proportional bias (≤1.6%) and a constant bias below the limit of detection was observed. CONCLUSIONS: The My5-FU assay demonstrated robust and highly comparable performance on different analyzers. Therefore, the assay is suitable for monitoring 5-FU plasma levels in routine clinical practice and may contribute to improved efficacy and safety of commonly used 5-FU-based chemotherapies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The increased use of vancomycin in hospitals has resulted in a standard practice to monitor serum vancomycin levels because of possible nephrotoxicity. However, the routine monitoring of vancomycin serum concentration is under criticism and the cost effectiveness of such routine monitoring is in question because frequent monitoring neither results in increase efficacy nor decrease nephrotoxicity. The purpose of the present study is to determine factors that may place patients at increased risk of developing vancomycin induced nephrotoxicity and for whom monitoring may be most beneficial.^ From September to December 1992, 752 consecutive in patients at The University of Texas M. D. Anderson Cancer Center, Houston, were prospectively evaluated for nephrotoxicity in order to describe predictive risk factors for developing vancomycin related nephrotoxicity. Ninety-five patients (13 percent) developed nephrotoxicity. A total of 299 patients (40 percent) were considered monitored (vancomycin serum levels determined during the course of therapy), and 346 patients (46 percent) were receiving concurrent moderate to highly nephrotoxic drugs.^ Factors that were found to be significantly associated with nephrotoxicity in univariate analysis were: gender, base serum creatinine greater than 1.5mg/dl, monitor, leukemia, concurrent moderate to highly nephrotoxic drugs, and APACHE III scores of 40 or more. Significant factors in the univariate analysis were then entered into a stepwise logistic regression analysis to determine independent predictive risk factors for vancomycin induced nephrotoxicity.^ Factors, with their corresponding odds ratios and 95% confidence limits, selected by stepwise logistic regression analysis to be predictive of vancomycin induced nephrotoxicity were: Concurrent therapy with moderate to highly nephrotoxic drugs (2.89; 1.76-4.74), APACHE III scores of 40 or more (1.98; 1.16-3.38), and male gender (1.98; 1.04-2.71).^ Subgroup (monitor and non-monitor) analysis showed that male (OR = 1.87; 95% CI = 1.01, 3.45) and moderate to highly nephrotoxic drugs (OR = 4.58; 95% CI = 2.11, 9.94) were significant for nephrotoxicity in monitored patients. However, only APACHE III score (OR = 2.67; 95% CI = 1.13,6.29) was significant for nephrotoxicity in non-monitored patients.^ The conclusion drawn from this study is that not every patient receiving vancomycin therapy needs frequent monitoring of vancomycin serum levels. Such routine monitoring may be appropriate in patients with one or more of the identified risk factors and low risk patients do not need to be subjected to the discomfort and added cost of multiple blood sampling. Such prudent selection of patients to monitor may decrease cost to patients and hospital. ^