1000 resultados para Patient hygiene
Resumo:
Knowledge of differences in voice and speech characteristics between novice and professional broadcasters is essential for effective education of broadcast journalism students. Because newsreaders rely on optimal voice production, information pertaining to vocal hygiene is also important. The first aim of this study was to compare the voice and speech characteristics of professional newsreaders, student newsreaders and control participants. The second aim was to compare the awareness and use of vocal hygiene across these groups. Professional radio newsreaders, broadcast journalism students and two matched control groups were included in the study. Each participant recorded a news bulletin and completed a questionnaire on vocal hygiene. Data analysis of the recording included objective analysis and perceptual ratings by a panel of three judges. Significant student-professional differences were found. Compared to both the students and the control groups, the professional newsreaders had greater variation in speaking fundamental frequency, a faster rate of speech, fewer pronunciation errors and higher perceptual ratings on vocal quality, emphasis, continuity, phrasing and style of newsreading. Female professional newsreaders had a higher speaking fundamental frequency than both their control participants and the student newsreaders. Comparison of vocal hygiene awareness revealed few significant differences between any of the groups.
Resumo:
Although obesity is associated with increased risks of morbidity and death in the general population, a number of studies of patients undergoing hemodialysis have demonstrated that increasing body mass index (BMI) is correlated with decreased mortality risk. Whether this association holds true among patients treated with peritoneal dialysis (PD) has been less well studied. The aim of this investigation was to examine the association between BMI and outcomes among new PD patients in a large cohort, with long-term follow-up monitoring. Using data from the Australia and New Zealand Dialysis and Transplant Registry, an analysis of all new adult patients (n = 9679) who underwent an episode of PD treatment in Australia or New Zealand between April 1, 1991, and March 31, 2002, was performed. Patients were classified as obese (BMI of greater than or equal to30 kg/m(2)), overweight (BMI of 25.0 to 29.9 kg/m(2)), normal weight (BMI of 20 to 24.9 kg/m(2)), or underweight (BMI of
Resumo:
ZigBee-based Remote Patient Monitoring
Resumo:
AIM: This work presents detailed experimental performance results from tests executed in the hospital environment for Health Monitoring for All (HM4All), a remote vital signs monitoring system based on a ZigBee® (ZigBee Alliance, San Ramon, CA) body sensor network (BSN). MATERIALS AND METHODS: Tests involved the use of six electrocardiogram (ECG) sensors operating in two different modes: the ECG mode involved the transmission of ECG waveform data and heart rate (HR) values to the ZigBee coordinator, whereas the HR mode included only the transmission of HR values. In the absence of hidden nodes, a non-beacon-enabled star network composed of sensing devices working on ECG mode kept the delivery ratio (DR) at 100%. RESULTS: When the network topology was changed to a 2-hop tree, the performance degraded slightly, resulting in an average DR of 98.56%. Although these performance outcomes may seem satisfactory, further investigation demonstrated that individual sensing devices went through transitory periods with low DR. Other tests have shown that ZigBee BSNs are highly susceptible to collisions owing to hidden nodes. Nevertheless, these tests have also shown that these networks can achieve high reliability if the amount of traffic is kept low. Contrary to what is typically shown in scientific articles and in manufacturers' documentation, the test outcomes presented in this article include temporal graphs of the DR achieved by each wireless sensor device. CONCLUSIONS: The test procedure and the approach used to represent its outcomes, which allow the identification of undesirable transitory periods of low reliability due to contention between devices, constitute the main contribution of this work.
Resumo:
The success of dental implant-supported prosthesis is directly linked to the accuracy obtained during implant’s pose estimation (position and orientation). Although traditional impression techniques and recent digital acquisition methods are acceptably accurate, a simultaneously fast, accurate and operator-independent methodology is still lacking. Hereto, an image-based framework is proposed to estimate the patient-specific implant’s pose using cone-beam computed tomography (CBCT) and prior knowledge of implanted model. The pose estimation is accomplished in a threestep approach: (1) a region-of-interest is extracted from the CBCT data using 2 operator-defined points at the implant’s main axis; (2) a simulated CBCT volume of the known implanted model is generated through Feldkamp-Davis-Kress reconstruction and coarsely aligned to the defined axis; and (3) a voxel-based rigid registration is performed to optimally align both patient and simulated CBCT data, extracting the implant’s pose from the optimal transformation. Three experiments were performed to evaluate the framework: (1) an in silico study using 48 implants distributed through 12 tridimensional synthetic mandibular models; (2) an in vitro study using an artificial mandible with 2 dental implants acquired with an i-CAT system; and (3) two clinical case studies. The results shown positional errors of 67±34μm and 108μm, and angular misfits of 0.15±0.08º and 1.4º, for experiment 1 and 2, respectively. Moreover, in experiment 3, visual assessment of clinical data results shown a coherent alignment of the reference implant. Overall, a novel image-based framework for implants’ pose estimation from CBCT data was proposed, showing accurate results in agreement with dental prosthesis modelling requirements.
Resumo:
The relationship between the hygienic habits of children who had typhoid fever (TF) who had recently begun attending school and their family group, is assessed. It is supposed that children, independently of their SES, acquired TF because of inadequate habits which facilitated the oral-fecal cycle. The sample was formed of 40 child-mother dyads: 20 of low SES (group A) and 20 of high SES (group B), the child of each of which had had TF. Results showed that the hygienic habits of children with respect to the oral-fecal cycle, their perception of school toilet cleanliness as well as the mothers' explanation of their children's hygienic habits is very similar in the two groups. The importance of these results is that the SES is seem to be irrelevant in the case of TF but that the hygienic habits of the children are of importance. Public health policy should be modified to include the teaching of proper hygienic habits (oral-fecal cycle).
Resumo:
The relationship between asymptomatic shedding of bacterial enteropathogens and the hygiene habits of families who have had a child with typhoid fever (TF) are investigated. The sample was made up of 80 families: 40 families in which one child had had TF (Group A) and 40 in which no children or either of the parents had had a history of TF (Group B). In each group 20 families belonged to a low socieconomic status (SES) and 20 to a high SES. A structured interview was used to evaluate the SES and the hygiene habits of the child; observations were made to measure the hygiene habits of the family (toilet, kitchen and food preparation) and bacteriological studies (fecal samples and hand markers). Results show that carriers were more frequent in Group A than in Group B. The bacterial species found were significantly more numerous in Group A than in Group B (fecal samples: E. coli, the classic serotypes, Shigella ssp, and hand markers: E. coli). Families of Group A had higher carriage rates than those of Group B. Finally there exists a significantly higher association between inadequate hygiene habits and carrier families. These results show the need to teach specific habits of proper hygiene to the entire population, because the fact of belonging to the high SES does not in itself preclude inadequate hygiene habits.
Resumo:
Esta tese pretende contribuir para o estudo e análise dos factores relacionados com as técnicas de aquisição de imagens radiológicas digitais, a qualidade diagnóstica e a gestão da dose de radiação em sistema de radiologia digital. A metodologia encontra-se organizada em duas componentes. A componente observacional, baseada num desenho do estudo de natureza retrospectiva e transversal. Os dados recolhidos a partir de sistemas CR e DR permitiram a avaliação dos parâmetros técnicos de exposição utilizados em radiologia digital, a avaliação da dose absorvida e o índice de exposição no detector. No contexto desta classificação metodológica (retrospectiva e transversal), também foi possível desenvolver estudos da qualidade diagnóstica em sistemas digitais: estudos de observadores a partir de imagens arquivadas no sistema PACS. A componente experimental da tese baseou-se na realização de experiências em fantomas para avaliar a relação entre dose e qualidade de imagem. As experiências efectuadas permitiram caracterizar as propriedades físicas dos sistemas de radiologia digital, através da manipulação das variáveis relacionadas com os parâmetros de exposição e a avaliação da influência destas na dose e na qualidade da imagem. Utilizando um fantoma contraste de detalhe, fantomas antropomórficos e um fantoma de osso animal, foi possível objectivar medidas de quantificação da qualidade diagnóstica e medidas de detectabilidade de objectos. Da investigação efectuada, foi possível salientar algumas conclusões. As medidas quantitativas referentes à performance dos detectores são a base do processo de optimização, permitindo a medição e a determinação dos parâmetros físicos dos sistemas de radiologia digital. Os parâmetros de exposição utilizados na prática clínica mostram que a prática não está em conformidade com o referencial Europeu. Verifica-se a necessidade de avaliar, melhorar e implementar um padrão de referência para o processo de optimização, através de novos referenciais de boa prática ajustados aos sistemas digitais. Os parâmetros de exposição influenciam a dose no paciente, mas a percepção da qualidade de imagem digital não parece afectada com a variação da exposição. Os estudos que se realizaram envolvendo tanto imagens de fantomas como imagens de pacientes mostram que a sobreexposição é um risco potencial em radiologia digital. A avaliação da qualidade diagnóstica das imagens mostrou que com a variação da exposição não se observou degradação substancial da qualidade das imagens quando a redução de dose é efectuada. Propõe-se o estudo e a implementação de novos níveis de referência de diagnóstico ajustados aos sistemas de radiologia digital. Como contributo da tese, é proposto um modelo (STDI) para a optimização de sistemas de radiologia digital.
Resumo:
In the last decades, the value of research on neurological patients’ quality of life (QOL) has become unquestionable. In this context, most studies focus on the relationship between patients’ QOL and their sociodemographic and/or clinical and/or modifiable psychosocial characteristics. They give us information regarding the sociodemographic and clinical profile most prone to low QOL reports and also on ways to improve patients’ QOL (e.g., targeting their selfesteem). Nevertheless, little is known about the role nonmodifiable psychosocial variables can have on patients’ QOL perception. Consequently, the aim of the present study is to explore the relationship between QOL and personality in neurological patients.
Resumo:
The assessment of patient dose has gained increased attention, still being an issue of concern that arises from the use of digital systems. The development of digital technology offers the possibility for a reduction of radiation dose around 50% without loss in image quality when compared to a conventional screen–film system. Digital systems give an equivalent or superior diagnostic performance and also several other advantages, but the risk of overexposure with no adverse effect on image quality could be present. This chapter refers to the management of patient dose and provides an explanation of dose-related concepts. In this chapter, exposure influence in dose and image representation and the effects of radiation exposure are also discussed.
Resumo:
The post-surgical period is often critical for infection acquisition. The combination of patient injury and environmental exposure through breached skin add risk to pre-existing conditions such as drug or depressed immunity. Several factors such as the period of hospital staying after surgery, base disease, age, immune system condition, hygiene policies, careless prophylactic drug administration and physical conditions of the healthcare centre may contribute to the acquisition of a nosocomial infection. A purulent wound can become complicated whenever antimicrobial therapy becomes compromised. In this pilot study, we analysed Enterobacteriaceae strains, the most significant gram-negative rods that may occur in post-surgical skin and soft tissue infections (SSTI) presenting reduced β-lactam susceptibility and those presenting extended-spectrum β-lactamases (ESBL). There is little information in our country regarding the relationship between β-lactam susceptibility, ESBL and development of resistant strains of microorganisms in SSTI. Our main results indicate Escherichia coli and Klebsiella spp. are among the most frequent enterobacteria (46% and 30% respectively) with ESBL production in 72% of Enterobacteriaceae isolates from SSTI. Moreover, coinfection occurred extensively, mainly with Pseudomonas aeruginosa and Methicillin-resistant Staphylococcus aureus (18% and 13%, respectively). These results suggest future research to explore if and how these associations are involved in the development of antibiotic resistance.