999 resultados para Patient handling


Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: This work presents detailed experimental performance results from tests executed in the hospital environment for Health Monitoring for All (HM4All), a remote vital signs monitoring system based on a ZigBee® (ZigBee Alliance, San Ramon, CA) body sensor network (BSN). MATERIALS AND METHODS: Tests involved the use of six electrocardiogram (ECG) sensors operating in two different modes: the ECG mode involved the transmission of ECG waveform data and heart rate (HR) values to the ZigBee coordinator, whereas the HR mode included only the transmission of HR values. In the absence of hidden nodes, a non-beacon-enabled star network composed of sensing devices working on ECG mode kept the delivery ratio (DR) at 100%. RESULTS: When the network topology was changed to a 2-hop tree, the performance degraded slightly, resulting in an average DR of 98.56%. Although these performance outcomes may seem satisfactory, further investigation demonstrated that individual sensing devices went through transitory periods with low DR. Other tests have shown that ZigBee BSNs are highly susceptible to collisions owing to hidden nodes. Nevertheless, these tests have also shown that these networks can achieve high reliability if the amount of traffic is kept low. Contrary to what is typically shown in scientific articles and in manufacturers' documentation, the test outcomes presented in this article include temporal graphs of the DR achieved by each wireless sensor device. CONCLUSIONS: The test procedure and the approach used to represent its outcomes, which allow the identification of undesirable transitory periods of low reliability due to contention between devices, constitute the main contribution of this work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laparoscopic surgery (LS) has revolutionized traditional surgical techniques introducing minimally invasive procedures for diagnosis and local therapies. LSs have undeniable advantages, such as small patient incisions, reduced postoperative pain and faster recovery. On the other hand, restricted vision of the anatomical target, difficult handling of the surgical instruments, restricted mobility inside the human body, need of dexterity to hand-eye coordination and inadequate and non-ergonomic surgical instruments may restrict LS only to more specialized surgeons. To overcome the referred limitations, this work presents a new robotic surgical handheld system – the EndoRobot. The EndoRobot was designed to be used in clinical practice or even as a surgical simulator. It integrates an electromechanical system with 3 degrees of freedom. Each degree can be manipulated independently and combined with different levels of sensitivity allowing fast and slow movements. As other features, the EndoRobot has battery power or external power supply, enables the use of bipolar radiofrequency to prevent bleeding while cutting and allows plug-and-play of the laparoscopic forceps for rapid exchange. As a surgical simulator, the system was also instrumented to measure and transmit, in real time, its position and orientation for a training software able to monitor and assist the trainee’s surgical movements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The success of dental implant-supported prosthesis is directly linked to the accuracy obtained during implant’s pose estimation (position and orientation). Although traditional impression techniques and recent digital acquisition methods are acceptably accurate, a simultaneously fast, accurate and operator-independent methodology is still lacking. Hereto, an image-based framework is proposed to estimate the patient-specific implant’s pose using cone-beam computed tomography (CBCT) and prior knowledge of implanted model. The pose estimation is accomplished in a threestep approach: (1) a region-of-interest is extracted from the CBCT data using 2 operator-defined points at the implant’s main axis; (2) a simulated CBCT volume of the known implanted model is generated through Feldkamp-Davis-Kress reconstruction and coarsely aligned to the defined axis; and (3) a voxel-based rigid registration is performed to optimally align both patient and simulated CBCT data, extracting the implant’s pose from the optimal transformation. Three experiments were performed to evaluate the framework: (1) an in silico study using 48 implants distributed through 12 tridimensional synthetic mandibular models; (2) an in vitro study using an artificial mandible with 2 dental implants acquired with an i-CAT system; and (3) two clinical case studies. The results shown positional errors of 67±34μm and 108μm, and angular misfits of 0.15±0.08º and 1.4º, for experiment 1 and 2, respectively. Moreover, in experiment 3, visual assessment of clinical data results shown a coherent alignment of the reference implant. Overall, a novel image-based framework for implants’ pose estimation from CBCT data was proposed, showing accurate results in agreement with dental prosthesis modelling requirements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta tese pretende contribuir para o estudo e análise dos factores relacionados com as técnicas de aquisição de imagens radiológicas digitais, a qualidade diagnóstica e a gestão da dose de radiação em sistema de radiologia digital. A metodologia encontra-se organizada em duas componentes. A componente observacional, baseada num desenho do estudo de natureza retrospectiva e transversal. Os dados recolhidos a partir de sistemas CR e DR permitiram a avaliação dos parâmetros técnicos de exposição utilizados em radiologia digital, a avaliação da dose absorvida e o índice de exposição no detector. No contexto desta classificação metodológica (retrospectiva e transversal), também foi possível desenvolver estudos da qualidade diagnóstica em sistemas digitais: estudos de observadores a partir de imagens arquivadas no sistema PACS. A componente experimental da tese baseou-se na realização de experiências em fantomas para avaliar a relação entre dose e qualidade de imagem. As experiências efectuadas permitiram caracterizar as propriedades físicas dos sistemas de radiologia digital, através da manipulação das variáveis relacionadas com os parâmetros de exposição e a avaliação da influência destas na dose e na qualidade da imagem. Utilizando um fantoma contraste de detalhe, fantomas antropomórficos e um fantoma de osso animal, foi possível objectivar medidas de quantificação da qualidade diagnóstica e medidas de detectabilidade de objectos. Da investigação efectuada, foi possível salientar algumas conclusões. As medidas quantitativas referentes à performance dos detectores são a base do processo de optimização, permitindo a medição e a determinação dos parâmetros físicos dos sistemas de radiologia digital. Os parâmetros de exposição utilizados na prática clínica mostram que a prática não está em conformidade com o referencial Europeu. Verifica-se a necessidade de avaliar, melhorar e implementar um padrão de referência para o processo de optimização, através de novos referenciais de boa prática ajustados aos sistemas digitais. Os parâmetros de exposição influenciam a dose no paciente, mas a percepção da qualidade de imagem digital não parece afectada com a variação da exposição. Os estudos que se realizaram envolvendo tanto imagens de fantomas como imagens de pacientes mostram que a sobreexposição é um risco potencial em radiologia digital. A avaliação da qualidade diagnóstica das imagens mostrou que com a variação da exposição não se observou degradação substancial da qualidade das imagens quando a redução de dose é efectuada. Propõe-se o estudo e a implementação de novos níveis de referência de diagnóstico ajustados aos sistemas de radiologia digital. Como contributo da tese, é proposto um modelo (STDI) para a optimização de sistemas de radiologia digital.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the last decades, the value of research on neurological patients’ quality of life (QOL) has become unquestionable. In this context, most studies focus on the relationship between patients’ QOL and their sociodemographic and/or clinical and/or modifiable psychosocial characteristics. They give us information regarding the sociodemographic and clinical profile most prone to low QOL reports and also on ways to improve patients’ QOL (e.g., targeting their selfesteem). Nevertheless, little is known about the role nonmodifiable psychosocial variables can have on patients’ QOL perception. Consequently, the aim of the present study is to explore the relationship between QOL and personality in neurological patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The production of MVOC by fungi has been taken into account especially from the viewpoint of indoor pollution with microorganisms but the relevance of fungal metabolites in working environments has not been sufficiently studied. The purpose of this study was to assess exposure to MVOCs in a waste-handling unit. It was used Multirae equipment (RAE Systems) to measured MVOCs concentration with a 10.6 eV lamps. The measurements were done near workers nose and during the normal activities. All measurements were done continuously and had the duration of 5 minutes at least. It was consider the higher value obtained in each measurement. In addition, for knowing fungi contamination, five air samples of 50 litres were collected through impaction method at 140 L/minute, at one meter tall, on to malt extract agar with the antibiotic chloramphenicol (MEA). MVOCs results range between 4.7 ppm and 8.9 ppm in the 6 locations consider. These results are eight times higher than normally obtained in indoor settings. Considering fungi results, two species were identified in air, being the genera Penicillium found in all the samples in uncountable colonies and Rhizopus only in one sample (40 UFC/m3). These fungi are known as MVOCs producers, namely terpenoids, ketones, alcohols and others. Until now, there has been no evidence that MVOCs are toxicologically relevant, but further epidemiological research is necessary to elucidate their role on human’s health, particularly in occupational settings where microbiological contamination is common. Additionally, further research should concentrate on quantitative analyses of specific MVOCs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The assessment of patient dose has gained increased attention, still being an issue of concern that arises from the use of digital systems. The development of digital technology offers the possibility for a reduction of radiation dose around 50% without loss in image quality when compared to a conventional screen–film system. Digital systems give an equivalent or superior diagnostic performance and also several other advantages, but the risk of overexposure with no adverse effect on image quality could be present. This chapter refers to the management of patient dose and provides an explanation of dose-related concepts. In this chapter, exposure influence in dose and image representation and the effects of radiation exposure are also discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background - Being patient centered is a core value for nursing. Patient centered-care has been related to patient and health provider satisfaction, better health outcomes, higher quality of care and more efficient health care delivery. Objectives - The purpose was to assess the orientation adopted by nurses and students in patient care, using The Patient-Practitioner Orientation Scale, as well as to compare the results between resident nurses and students from different academic years. Settings - Public School of Nursing and a Central Hospital, in Lisbon (Portugal). Participants - Students in the first, second and fourth year of nursing school and nurses participated in the study. Methods - For data collection, we used The Patient-Practitioner Orientation Scale (European Portuguese version), an instrument designed to measure individual preferences toward the dimension of caring a sharing in health professional-patient relationship. Students and nurses also filled out two additional questions about their perception of competence in technical and communication skills. Additional demographic information was also collected, including gender, age, academic year and length of professional experience. Results - A total of 525 students (84.7% female) and 108 nurses (77.8% female) participated in this study. In general, caring sub-scores, measuring the preference of about attending to patient emotional aspects, were higher than sharing sub-scores, measuring beliefs about giving information and perceiving patient as a member of the health team. Students were significantly more patient-centered throughout their nursing education (p<0.001). Comparing to students in the second and fourth academic years (p<0.001) nurses' scores were significantly lower both in total PPOS and in caring and sharing subscales. Conclusions - These results reinforce the idea that patient centeredness may be developed in academic context. The scores obtained highlight the importance of studies that aim to identify factors that may explain the decrease of patient centeredness in professional practice.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose – Quantitative instruments to assess patient safety culture have been developed recently and a few review articles have been published. Measuring safety culture enables healthcare managers and staff to improve safety behaviours and outcomes for patients and staff. The study aims to determine the AHRQ Hospital Survey on Patient Safety Culture (HSPSC) Portuguese version's validity and reliability. Design/methodology/approach – A missing-value analysis and item analysis was performed to identify problematic items. Reliability analysis, inter-item correlations and inter-scale correlations were done to check internal consistency, composite scores. Inter-correlations were examined to assess construct validity. A confirmatory factor analysis was performed to investigate the observed data's fit to the dimensional structure proposed in the AHRQ HSPSC Portuguese version. To analyse differences between hospitals concerning composites scores, an ANOVA analysis and multiple comparisons were done. Findings – Eight of 12 dimensions had Cronbach's alphas higher than 0.7. The instrument as a whole achieved a high Cronbach's alpha (0.91). Inter-correlations showed that there is no dimension with redundant items, however dimension 10 increased its internal consistency when one item is removed. Originality/value – This study is the first to evaluate an American patient safety culture survey using Portuguese data. The survey has satisfactory reliability and construct validity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Actualmente, os smartphones e outros dispositivos móveis têm vindo a ser dotados com cada vez maior poder computacional, sendo capazes de executar um vasto conjunto de aplicações desde simples programas de para tirar notas até sofisticados programas de navegação. Porém, mesmo com a evolução do seu hardware, os actuais dispositivos móveis ainda não possuem as mesmas capacidades que os computadores de mesa ou portáteis. Uma possível solução para este problema é distribuir a aplicação, executando partes dela no dispositivo local e o resto em outros dispositivos ligados à rede. Adicionalmente, alguns tipos de aplicações como aplicações multimédia, jogos electrónicos ou aplicações de ambiente imersivos possuem requisitos em termos de Qualidade de Serviço, particularmente de tempo real. Ao longo desta tese é proposto um sistema de execução de código remota para sistemas distribuídos com restrições de tempo-real. A arquitectura proposta adapta-se a sistemas que necessitem de executar periodicamente e em paralelo mesmo conjunto de funções com garantias de tempo real, mesmo desconhecendo os tempos de execução das referidas funções. A plataforma proposta foi desenvolvida para sistemas móveis capazes de executar o Sistema Operativo Android.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Several antineoplastic drugs have been classified as carcinogens by the International Agency for Research on Cancer (IARC) on the basis of epidemiological findings, animal carcinogenicity data, and outcomes of in vitro genotoxicity studies. 5-Fluorouracil (5-FU), which is easily absorbed through the skin, is the most frequently used antineoplastic agent in Portuguese hospitals and therefore may be used as an indicator of surface contamination. The aims of the present investigation were to (1) examine surface contamination by 5-FU and (2) assess the genotoxic risk using cytokinesis-block micronucleus assay in nurses from two Portuguese hospitals. The study consisted of 2 groups: 27 nurses occupationally exposed to cytostatic agents (cases) and 111 unexposed individuals (controls). Peripheral blood lymphocytes (PBL) were collected in order to measure micronuclei (MN) in both groups. Hospital B showed a higher numerical level of contamination but not significantly different from Hospital A. However; Hospital A presented the highest value of contamination and also a higher proportion of contaminated samples. The mean frequency of MN was significantly higher in exposed workers compared with controls. No significant differences were found among MN levels between the two hospitals. The analysis of confounding factors showed that age is a significant variable in MN frequency occurrence. Data suggest that there is a potential genotoxic damage related to occupational exposure to cytostatic drugs in oncology nurses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective - To define a checklist that can be used to assess the performance of a department and evaluate the implementation of quality management (QM) activities across departments or pathways in acute care hospitals. Design - We developed and tested a checklist for the assessment of QM activities at department level in a cross-sectional study using on-site visits by trained external auditors. Setting and Participants - A sample of 292 hospital departments of 74 acute care hospitals across seven European countries. In every hospital, four departments for the conditions: acute myocardial infarction (AMI), stroke, hip fracture and deliveries participated. Main outcome measures - Four measures of QM activities were evaluated at care pathway level focusing on specialized expertise and responsibility (SER), evidence-based organization of pathways (EBOP), patient safety strategies and clinical review (CR). Results - Participating departments attained mean values on the various scales between 1.2 and 3.7. The theoretical range was 0-4. Three of the four QM measures are identical for the four conditions, whereas one scale (EBOP) has condition-specific items. Correlations showed that every factor was related, but also distinct, and added to the overall picture of QM at pathway level. Conclusion - The newly developed checklist can be used across various types of departments and pathways in acute care hospitals like AMI, deliveries, stroke and hip fracture. The anticipated users of the checklist are internal (e.g. peers within the hospital and hospital executive board) and external auditors (e.g. healthcare inspectorate, professional or patient organizations).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mobile applications are becoming increasingly more complex and making heavier demands on local system resources. Moreover, mobile systems are nowadays more open, allowing users to add more and more applications, including third-party developed ones. In this perspective, it is increasingly expected that users will want to execute in their devices applications which supersede currently available resources. It is therefore important to provide frameworks which allow applications to benefit from resources available on other nodes, capable of migrating some or all of its services to other nodes, depending on the user needs. These requirements are even more stringent when users want to execute Quality of Service (QoS) aware applications, such as voice or video. The required resources to guarantee the QoS levels demanded by an application can vary with time, and consequently, applications should be able to reconfigure themselves. This paper proposes a QoS-aware service-based framework able to support distributed, migration-capable, QoS-enabled applications on top of the Android Operating system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is an increasing demand for highly dynamic realtime systems where several independently developed applications with different timing requirements can coexist. This paper proposes a protocol to integrate shared resources and precedence constraints among tasks in such systems assuming no precise information on critical sections and computation times is available. The concept of bandwidth inheritance is combined with a capacity sharing and stealing mechanism to efficiently exchange bandwidth among needed tasks, minimising the cost of blocking.