978 resultados para PLANTAR PRESSURES


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent research seeking to elucidate the possible effects of different types of physical training on the morphological adaptations of skeletal muscle. Although it is relatively easy to study the effects of exercise training in humans, such research becomes limited due to the invasive nature of the biopsies and the risk inherent in the use of human subjects. Thus, the application of animal models of training has been considered an appropriate strategy for the study of muscular adaptations in response to exercise. Objective: This study used a rodent model to determine the possible effects of aerobic and strength training on the CSA of fibers of the plantaris muscle. Methods: 24 male Wistar rats (80 to 120 days, 250 to 400 g) were randomly divided into 3 groups: aerobic training (TA, n = 8), strength training (ST, n = 8) and control (CO, n = 8). The animals in groups TA and TF were subjected to 8 weeks of training, while the animals of group C remained without any stimulus from start to finish the training period. At the end of the experiment, the animals were sacrificed and right plantar muscles dissected and removed. For morphological and morphometric analysis of muscle fibers was performed staining was performed H.E. Results: There was no significant difference in initial body weight between experimental groups. After 8 weeks of training, the TA group showed a significant reduction in final body weight, compared to CO and TF groups. With respect to the CSA of fibers of the plantaris muscle, no significant difference between the groups CO and TA. On the other hand, the strength training promoted a significant increase in AST of the group TF in compared with the groups CO and TA. Conclusion: Strength training used in this study promoted an increase in CSA of fibers of the plantaris muscle. On the other hand, animals submitted to aerobic training showed no changes in the CSA of the fibers, however, there was reduction in PC animals. The data strongly suggest the use of animal model of strength training used in this study as an appropriate strategy for studying the hypertrophic response of skeletal muscle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Optimal levels of noise stimulation have been shown to enhance the detection and transmission of neural signals thereby improving the performance of sensory and motor systems. The first series of experiments in the present study aimed to investigate whether subsensory electrical noise stimulation applied over the triceps surae (TS) in seated subjects decreases torque variability during a force-matching task of isometric plantar flexion and whether the same electrical noise stimulation decreases postural sway during quiet stance. Correlation tests were applied to investigate whether the noise-induced postural sway decrease is linearly predicted by the noise-induced torque variability decrease. A second series of experiments was conducted to investigate whether there are differences in torque variability between conditions in which the subsensory electrical noise is applied only to the TS, only to the tibialis anterior (TA) and to both TS and TA, during the force-matching task with seated subjects. Noise stimulation applied over the TS muscles caused a significant reduction in force variability during the maintained isometric force paradigm and also decreased postural oscillations during quiet stance. Moreover, there was a significant correlation between the reduction in force fluctuation and the decrease in postural sway with the electrical noise stimulation. This last result indicates that changes in plantar flexion force variability in response to a given subsensory random stimulation of the TS may provide an estimate of the variations in postural sway caused by the same subsensory stimulation of the TS. We suggest that the decreases in force variability and postural sway found here are due to stochastic resonance that causes an improved transmission of proprioceptive information. In the second series of experiments, the reduction in force variability found when noise was applied to the TA muscle alone did not reach statistical significance, suggesting that TS proprioception gives a better feedback to reduce force fluctuation in isometric plantar flexion conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intravascular ultrasound (IVUS) phantoms are important to calibrate and evaluate many IVUS imaging processing tasks. However, phantom generation is never the primary focus of related works; hence, it cannot be well covered, and is usually based on more than one platform, which may not be accessible to investigators. Therefore, we present a framework for creating representative IVUS phantoms, for different intraluminal pressures, based on the finite element method and Field II. First, a coronary cross-section model is selected. Second, the coronary regions are identified to apply the properties. Third, the corresponding mesh is generated. Fourth, the intraluminal force is applied and the deformation computed. Finally, the speckle noise is incorporated. The framework was tested taking into account IVUS contrast, noise and strains. The outcomes are in line with related studies and expected values. Moreover, the framework toolbox is freely accessible and fully implemented in a single platform. (E-mail: fernando.okara@gmail.com) (c) 2012 World Federation for Ultrasound in Medicine & Biology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare individuals with and without hyperhidrosis in terms of the intensity of palmar and plantar sweating. Methods: We selected 50 patients clinically diagnosed with palmoplantar hyperhidrosis and 25 normal individuals as controls. We quantified sweating using a portable noninvasive electronic device that has relative humidity and temperature sensors to measure transepidermal water loss. All of the individuals had a body mass index of 20-25 kg/cm(2). Subjects remained at rest for 20-30 min before the measurements in order to reduce external interference. The measurements were carried out in a climate-controlled environment (21-24 degrees C). Measurements were carried out on the hypothenar region on both hands and on the medial plantar region on both feet. Results: In the palmoplantar hyperhidrosis group, the mean transepidermal water loss on the hands and feet was 133.6 +/- 51.0 g/m(2)/h and 71.8 +/- 40.3 g/m(2)/h, respectively, compared with 37.9 +/- 18.4 g/m(2)/h and 27.6 +/- 14.3 g/m(2)/h, respectively, in the control group. The differences between the groups were statistically significant (p < 0.001 for hands and feet). Conclusions: This method proved to be an accurate and reliable tool to quantify palmar and plantar sweating when performed by a trained and qualified professional.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Cardiac surgery (CC) determines systemic and pulmonary changes that require special care. What motivated several studies conducted in healthy subjects to assess muscle strength were the awareness of the importance of respiratory muscle dysfunction in the development of respiratory failure. These studies used maximal inspiratory pressure (MIP) and maximal expiratory pressure (MEP) values. This study examined the concordance between the values predicted by the equations proposed by Black & Hyatt and Neder, and the measured values in cardiac surgery (CS) patients. Methods: Data were collected from preoperative evaluation forms. The Lin coefficient and Bland-Altman plots were used for statistical concordance analysis. The multiple linear regression and analysis of variance (ANOVA) were used to produce new formulas. Results: There were weak correlations of 0.22 and 0.19 in the MIP analysis and of 0.10 and 0.32 in the MEP analysis, for the formulas of Black & Hyatt and Neder, respectively. The ANOVA for both MIP and MEP were significant (P <0.0001), and the following formulas were developed: MIP = 88.82 - (0.51 x age) + (19.86 x gender), and MEP = 91.36 -(030 x age) + (29.92 x gender). Conclusions: The Black and Hyatt and Neder formulas predict highly discrepant values of MIP and MEP and should not be used to identify muscle weakness in CS patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a new enrichment space to accommodate jumps in the pressure field at immersed interfaces in finite element formulations, is proposed. The new enrichment adds two degrees of freedom per element that can be eliminated by means of static condensation. The new space is tested and compared with the classical P1 space and to the space proposed by Ausas et al (Comp. Meth. Appl. Mech. Eng., Vol. 199, 10191031, 2010) in several problems involving jumps in the viscosity and/or the presence of singular forces at interfaces not conforming with the element edges. The combination of this enrichment space with another enrichment that accommodates discontinuities in the pressure gradient has also been explored, exhibiting excellent results in problems involving jumps in the density or the volume forces. Copyright (c) 2011 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: High-frequency trains of electrical stimulation applied over the human muscles can generate forces higher than would be expected by direct activation of motor axons, as evidenced by an unexpected relation between the stimuli and the evoked contractions, originating what has been called “extra forces”. This phenomenon has been thought to reflect nonlinear input/output neural properties such as plateau potential activation in motoneurons. However, more recent evidence has indicated that extra forces generated during electrical stimulation are mediated primarily, if not exclusively, by an intrinsic muscle property, and not from a central mechanism as previously thought. Given the inherent differences between electrical and vibratory stimuli, this study aimed to investigate: (a) whether the generation of vibration-induced muscle forces results in an unexpected relation between the stimuli and the evoked contractions (i.e. extra forces generation) and (b) whether these extra forces are accompanied by signs of a centrally-mediated mechanism or whether intrinsic muscle properties are the redominant mechanisms. Methods: Six subjects had their Achilles tendon stimulated by 100 Hz vibratory stimuli that linearly increased in amplitude (with a peak-to-peak displacement varying from 0 to 5 mm) for 10 seconds and then linearly decreased to zero for the next 10 seconds. As a measure of motoneuron excitability taken at different times during the vibratory stimulation, short-latency compound muscle action potentials (V/F-waves) were recorded in the soleus muscle in response to supramaximal nerve stimulation. Results: Plantar flexion torque and soleus V/F-wave amplitudes were increased in the second half of the stimulation in comparison with the first half. Conclusion: The present findings provide evidence that vibratory stimuli may trigger a centrally-mediated mechanism that contributes to the generation of extra torques. The vibration-induced increased motoneuron excitability (leading to increased torque generation) presumably activates spinal motoneurons following the size principle, which is a desirable feature for stimulation paradigms involved in rehabilitation programs and exercise training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Demonstrar os achados em ressonância magnética (RM) da tromboflebite plantar. MÉTODOS: Revisão retrospectiva de 20 pacientes com dor na região plantar nos quais os achados de ressonância magnética indicaram tromboflebite plantar. RESULTADOS: Foram avaliados 14 homens e seis mulheres, com idade média de 46,7 anos. Oito desses pacientes também foram submetidos à ultrassonografia com doppler, que confirmaram a tromboflebite. As imagens de ressonância magnética foram avaliadas em consenso por dois radiologistas com experiência em radiologia do sistema musculoesquelético (mais de 10 anos cada um), demonstrando edema perivascular em todos os 20 pacientes (100%) e edema muscular em 19 dos 20 pacientes (95%). Todos os 20 pacientes apresentavam intensidade de sinal intermediária intraluminal em T2 (100%) e ectasia venosa estava presente em 17 dos 20 casos (85%). Veias colaterais foram visualizadas em um dos 20 pacientes (5%). Todos os 14 casos (100%), nos quais o contraste intravenoso foi administrado, apresentavam realce dos tecidos perivenulares e defeito de enchimento intraluminal. Ectasia venosa, perda da compressibilidade e ausência de fluxo na ultrassonografia com doppler também foram observados em todos os oito casos examinados pelo método. CONCLUSÕES: A RM é um método sensível na avaliação de tromboflebite plantar em pacientes com dor plantar.