977 resultados para PANORAMIC RADIOGRAPHS
Resumo:
We developed an object-oriented cross-platform program to perform three-dimensional (3D) analysis of hip joint morphology using two-dimensional (2D) anteroposterior (AP) pelvic radiographs. Landmarks extracted from 2D AP pelvic radiographs and optionally an additional lateral pelvic X-ray were combined with a cone beam projection model to reconstruct 3D hip joints. Since individual pelvic orientation can vary considerably, a method for standardizing pelvic orientation was implemented to determine the absolute tilt/rotation. The evaluation of anatomically morphologic differences was achieved by reconstructing the projected acetabular rim and the measured hip parameters as if obtained in a standardized neutral orientation. The program had been successfully used to interactively objectify acetabular version in hips with femoro-acetabular impingement or developmental dysplasia. Hip(2)Norm is written in object-oriented programming language C++ using cross-platform software Qt (TrollTech, Oslo, Norway) for graphical user interface (GUI) and is transportable to any platform.
Resumo:
Acetabular retroversion has been proposed to contribute to the development of osteoarthritis of the hip. For the diagnosis of this condition, conventional AP pelvic radiographs may represent a reliable, easily available diagnostic modality as they can be obtained with a reproducible technique allowing the anterior and posterior acetabular rims to be visible for assessment. This study was designed to: (i) determine cranial, central, and caudal anatomic acetabular version (AV) from cadaveric specimens; (ii) establish the validity and reliability of the radiographic measurements of central acetabular anteversion; and (iii) determine the validity and reliability of the radiographic "cross-over-sign" to detect acetabular retroversion. Using 43 desiccated pelvises (86 acetabuli) the anatomic AVs were measured at three different transverse planes (cranially, centrally, and caudally). From these pelvises, standardized AP pelvic radiographs were obtained. To directly measure central AV, a modified radiographic method is introduced for the use of AP pelvic radiographs. The validity and reliability of this radiographic method and of the radiographic cross-over-sign to detect cranial acetabular retroversion were determined. The mean central and caudal anatomic AVs were approximately 20 degrees , and the mean cranial AV was 8 degrees . Cranial retroversion (AV < 0 degrees ) was present in 19 of 86 hips (22%). A linear correlation was found between the central and cranial AV. Below 10 degrees of central AV, all acetabuli were cranially retroverted. Between 10 degrees and 20 degrees , 30% of the acetabuli were cranially retroverted, and above 20 degrees , only 1 of 45 acetabuli was cranially retroverted. The radiographic measurement of the central AV (20.3 +/- 6.5 degrees ) correlated strongly with the anatomic AV (20.1 +/- 6.4 degrees ). The sensitivity of the cross-over-sign to detect a cranial acetabular anteversion of less than 4 degrees was 96%, its specificity 95%, and the positive predictive and negative predictive values 90% and 98%, respectively. Both the modified radiographic anteversion measurements and the cross-over-sign demonstrated substantial inter- and intraobserver reliability. Retroversion is almost exclusively a problem of the cranial acetabulum. The cranial AV is on average 12 degrees lower than the central AV, with the latter directly measurable from AP pelvic radiographs. A central AV of less than 10 degrees was associated with cranial retroversion. The presence of a positive cross-over-sign is a highly reliable indicator of cranial AV of <4 degrees.
Resumo:
For CT scan planning, scan projection radiographs (SPR) are used. Tube tension and current for head SPR can be reduced to a minimum because of the small head diameter and because only high-contrast structures need to be visualized for planning. The goal of this study was to investigate SPR of the head in respect to effective doses, the influence of dose-reduction measures, and comparison with conventional x-ray.
Resumo:
OBJECTIVES: Bone attrition probably constitutes remodeling of the bone, resulting in flattening or depression of the articular surfaces. Defining bone attrition is challenging because it is an accentuation of the normal curvature of the tibial plateaus. We aimed to define bone attrition on magnetic resonance imaging (MRI) of the knee using information from both radiographs and MRIs, and to assess whether bone attrition is common prior to end stage disease osteoarthritis (OA) in the tibio-femoral joint. METHODS: All knees of participants in the community-based sample of the Framingham OA Study were evaluated for bone attrition in radiographs and MRIs. Radiographs were scored based on templates designed to outline the normal contours of the tibio-femoral joint. MRIs were analyzed using the semi-quantitative Whole-Organ Magnetic Resonance Imaging Scoring (WORMS) method. The prevalence of bone attrition was calculated using two different thresholds for MRI scores. RESULTS: Inter-observer agreement for identification of bone attrition was substantial for the radiographs (kappa=0.71, 95% CI 0.67-0.81) and moderate for MRI (kappa=0.56, 95% CI 0.40-0.72). Of 964 knees, 5.7% of the radiographs showed bone attrition. Of these, 91% of MRIs were also read as showing bone attrition. We selected a conservative threshold for bone attrition on MRI scoring (> or = 2 on a 0-3 scale) based on agreement with attrition on the radiograph or when bone attrition on MRI co-occurred with cartilage loss on OA. Using this threshold for bone attrition on MRI, bone attrition was common in knees with OA. For example, in knees with mild OA but no joint space narrowing, 13 of 88 MRIs (14.8%) showed bone attrition. CONCLUSIONS: Using MRI we found that many knees with mild OA without joint narrowing on radiographs had bone attrition, even using conservative definitions. The validity of our definition of bone attrition should be evaluated in further studies. Bone attrition may occur in milder OA and at earlier stages of disease than previously thought.
Resumo:
Femoroacetabular impingement (FAI) is a pathologic condition of the hip joint in young adults that, if untreated, leads to end-stage osteoarthritis. It is characterized by early pathologic contact between primary osseous prominences of the acetabular rim (so-called pincer FAI) and/or the femoral head-neck junction (cam FAI). Conventional radiographs are often considered normal because classic radiographic signs of osteoarthritis are not present initially. The physician should be aware of the radiographic features for both types of impingement to recognize subtle pathologies.
Resumo:
Asphericity of the femoral head-neck junction is one cause for femoroacetabular impingement of the hip. However, the asphericity often is underestimated on conventional radiographs. This study compares the presence of asphericity on conventional radiographs with its appearance on radial slices of magnetic resonance arthrography (MRA). We retrospectively reviewed 58 selected hips in 148 patients who underwent a surgical dislocation of the hip. To assess the circumference of the proximal femur, alpha angle and height of asphericity were measured in 14 positions using radial slices of MRA. The hips were assigned to one of four groups depending on the appearance of the head-neck junction on anteroposterior pelvic and lateral crosstable radiographs. Group I (n = 19) was circular on both planes, Group II (n = 19) was aspheric on the crosstable view, Group III (n = 4) was aspheric on the anteroposterior view, and Group IV (n = 13) was aspheric on both views. In all four groups, the highest alpha angle was found in the anterosuperior area of the head-neck junction. Even when conventional radiographs appeared normal, an increased alpha angle was present anterosuperiorly. Without the use of radial slices in MRA, the asphericity would be underestimated in these patients.
Resumo:
OBJECTIVES: To demonstrate the feasibility of panoramic image subtraction for implant assessment. STUDY DESIGN: Three titanium implants were inserted into a fresh pig mandible. One intraoral and 2 panoramic images were obtained at baseline and after each of 6 incremental (0.3, 0.6, 1.0, 1.5, 2.0, 2.5 mm) removals of bone. For each incremental removal of bone, the mandible was removed from and replaced in the holding device. Images representing incremental bone removals were registered by computer with the baseline images and subtracted. Assessment of the subtraction images was based on visual inspection and analysis of structured noise. RESULTS: Incremental bone removals were more visible in intraoral than in panoramic subtraction images; however, computer-based registration of panoramic images reduced the structured noise and enhanced the visibility of incremental removals. CONCLUSION: The feasibility of panoramic image subtraction for implant assessment was demonstrated.
Resumo:
The aim of this study was to evaluate whether measurements performed on conventional frontal radiographs are comparable to measurements performed on three-dimensional (3D) models of human skulls derived from cone beam computed tomography (CBCT) scans and if the latter can be used in longitudinal studies. Cone beam computed tomography scans and conventional frontal cephalometric radiographs were made of 40 dry human skulls. From the CBCT scan a 3D model was constructed. Standard cephalometric software was used to identify landmarks and to calculate ratios and angles. The same operator identified 10 landmarks on both types of cephalometric radiographs, and on all images, five times with a time interval of 1 wk. Intra-observer reliability was acceptable for all measurements. There was a statistically significant and clinically relevant difference between measurements performed on conventional frontal radiographs and on 3D CBCT-derived models of the same skull. There was a clinically relevant difference between angular measurements performed on conventional frontal cephalometric radiographs, compared with measurements performed on 3D models constructed from CBCT scans. We therefore recommend that 3D models should not be used for longitudinal research in cases where there are only two-dimensional (2D) records from the past.
Resumo:
This study evaluated whether measurements on conventional frontal radiographs are comparable with measurements on cone beam computed tomography (CBCT)-constructed frontal cephalometric radiographs taken from dry human skulls. CBCT scans and conventional frontal cephalometric radiographs were made of 40 dry skulls. With I-Cat Vision((R)) software, a cephalometric radiograph was constructed from the CBCT scan. Standard cephalometric software was used to identify landmarks and calculate ratios and angles. The same operator identified 10 landmarks on both types of cephalometric radiographs on all Images 5 times with a time-interval of 1 week. Intra-observer reliability was acceptable for all measurements. The reproducibility of the measurements on the frontal radiographs obtained from the CBCT scans was higher than those on conventional frontal radiographs. There is a statistically significant and clinically relevant difference between measurements on conventional and constructed frontal radiographs. There is a clinically relevant difference between angular measurements performed on conventional frontal cephalometric radiographs, compared with measurements on frontal cephalometric radiographs constructed from CBCT scans, owing to different positioning of patients in both devices. Positioning of the patient in the CBCT device appears to be an important factor in cases where a 2D projection of the 3D scan is made.
Resumo:
The purpose of this retrospective study was to intra-individually compare the image quality of computed radiography (CR) and low-dose linear-slit digital radiography (LSDR) for supine chest radiographs. A total of 90 patients (28 female, 62 male; mean age, 55.1 years) imaged with CR and LSDR within a mean time interval of 2.8 days +/- 3.0 were included in this study. Two independent readers evaluated the image quality of CR and LSDR based on modified European Guidelines for Quality Criteria for chest X-ray. The Wilcoxon test was used to analyse differences between the techniques. The overall image quality of LSDR was significantly better than the quality of CR (9.75 vs 8.16 of a maximum score of 10; p < 0.001). LSDR performed significantly better than CR for delineation of anatomical structures in the mediastinum and the retrocardiac lung (p < 0.001). CR was superior to LSDR for visually sharp delineation of the lung vessels and the thin linear structures in the lungs. We conclude that LSDR yields better image quality and may be more suitable for excluding significant pathological features of the chest in areas with high attenuation compared with CR.