910 resultados para Operational analytics


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An electronic load interface (ELI) for improving the operational margin of a photovoltaic (PV) dual-converter system under dynamic conditions is presented. The ELI - based on a modified buck-boost converter - interfaces the output of the converters and the load system. It improves the operational margin of the PV dual-converter system by extending the conditions under which the dual-converter system operates at the maximum power point. The ELI is activated as and when needed, so as minimise system losses. By employing the ELI, utilisation and efficiency of a PV dual-converter system increases. In general, the concept of the ELI can be applied to multi-converter PV systems - such as multi-converter inverters, and multi-converter DC-DC converter systems - for performance and efficiency improvement. © 2013 The Institution of Engineering and Technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The importance of properly exploiting a classifier's inherent geometric characteristics when developing a classification methodology is emphasized as a prerequisite to achieving near optimal performance when carrying out thematic mapping. When used properly, it is argued that the long-standing maximum likelihood approach and the more recent support vector machine can perform comparably. Both contain the flexibility to segment the spectral domain in such a manner as to match inherent class separations in the data, as do most reasonable classifiers. The choice of which classifier to use in practice is determined largely by preference and related considerations, such as ease of training, multiclass capabilities, and classification cost. © 1980-2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, optimization of operational conditions of a submerged membrane bioreactor treating municipal waste-water was studied. Mixed liquid suspended solid (MLSS), membrane flux (J(v)), aeration (Q), ratio of pumping, time to break time (t(p)/t(b)), and ratio of up flow area to down flow area (A Ad) were chosen as the easily manipulable parameters to study their effects on removal efficiency and membrane fouling. Totally, 16 different runs were designed to compare and select the best combination of the 5 parameters. The results showed that the optimal operational conditions were MLSS = 7g(.)L(-1), J(v) = 10L(.)m(-2.)h(-1), Q = 6 m(3.)h(-1), t(p)/t(b)= 4 min/1 min, and A(r)/A(d) = 1.7 m(2)/m(2). Under such conditions, the SMBR could achieve a double win of high removal efficiency and low membrane fouling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A detailed reaction-tran sport model was studied in a showerhead reactor for metal organic chemical vapor deposition of GaN film by using computational fluid dynamics simulation. It was found that flat flow lines without swirl are crucial to improve the uniformity of the film growth, and thin temperature gradient above the suscptor can increase the film deposition rate. By above-mentioned research, we can employ higher h (the distance from the susceptor to the inlet), P (operational pressure) and the rate of susceptor rotation to improve the film growth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, we analyzed the operational characteristics of a 1.2-MW rice husk gasification and power generation plant located in Changxing, Zhejiang province, China. The influences of gasification temperature, equivalence ratio (ER), feeding rate and rice husk water content on the gasification characteristics in a fluidized bed gasifier were investigated. The axial temperature profile in the dense phase of the gasifier showed that inadequate fluidization occurred inside the bed, and that the temperature was closely related to changes in ER and feeding rate. The bed temperature increased linearly with increasing ER when the feeding rate was kept constant, while a higher feeding rate corresponded to a lower bed temperature at fixed ER. The gas heating value decreased with increasing temperature, while the feeding rate had little effect. When the gasification temperature was 700-800C, the gas heating value ranged from 5450-6400kJ/Nm3. The water content of the rice husk had an obvious influence on the operation of the gasifier: increases in water content up to 15% resulted in increasing ER and gas yield, while water contents above 15% caused aberrant temperature fluctuations. The problems in this plant are discussed in the light of operational experience of MW-scale biomass gasification and power generation plants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to realize the common-emitter characteristics of the tris(8-hydroxyquinoline) aluminium (Alq(3))-based organic transistors, we used Au/Al double metal layer as the base, thus the vertical metal-base transistors with structure of Al/n-Si/Au/Al/Alq(3)/LiF/Al were constructed. It was found that the contact properties between the base and the organic semiconductors play an important role in the device performance. The utilization of Au/Al double layer metal base allows the devices to operate at high gain in the common-emitter and common-base mode at low operational voltage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate the suitability of N,N'-diphenyl-N,N'-bis(1-naphthylphenyl)-1,1'-biphenyl-4,4'-diamine (NPB), an organic semiconductor widely used in organic light-emitting diodes (OLEDs), for high-gain, low operational voltage nanostructured vertical-architecture transistors, which operate as permeable-base transistors. By introducing vanadium oxide (V2O5) between the injecting metal and NPB layer at the transistor emitter, we reduced the emitter operational voltage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electrical circuit designers seldom create really new topologies or use old ones in a novel way. Most designs are known combinations of common configurations tailored for the particular problem at hand. In this thesis I show that much of the behavior of a designer engaged in such ordinary design can be modelled by a clearly defined computational mechanism executing a set of stylized rules. Each of my rules embodies a particular piece of the designer's knowledge. A circuit is represented as a hierarchy of abstract objects, each of which is composed of other objects. The leaves of this tree represent the physical devices from which physical circuits are fabricated. By analogy with context-free languages, a class of circuits is generated by a phrase-structure grammar of which each rule describes how one type of abstract object can be expanded into a combination of more concrete parts. Circuits are designed by first postulating an abstract object which meets the particular design requirements. This object is then expanded into a concrete circuit by successive refinement using rules of my grammar. There are in general many rules which can be used to expand a given abstract component. Analysis must be done at each level of the expansion to constrain the search to a reasonable set. Thus the rule of my circuit grammar provide constraints which allow the approximate qualitative analysis of partially instantiated circuits. Later, more careful analysis in terms of more concrete components may lead to the rejection of a line of expansion which at first looked promising. I provide special failure rules to direct the repair in this case.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gilmore, A.; Gallagher, D.; and Henry, S. (2007). E-marketing and SMEs: Operational lessons for the future. European Business Review. 19(3), pp.234-247 RAE2008

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wind energy is predominantly a nonsynchronous generation source. Large-scale integration of wind generation with existing electricity systems, therefore, presents challenges in maintaining system frequency stability and local voltage stability. Transmission system operators have implemented system operational constraints (SOCs) in order to maintain stability with high wind generation, but imposition of these constraints results in higher operating costs. A mixed integer programming tool was used to simulate generator dispatch in order to assess the impact of various SOCs on generation costs. Interleaved day-ahead scheduling and real-time dispatch models were developed to allow accurate representation of forced outages and wind forecast errors, and were applied to the proposed Irish power system of 2020 with a wind penetration of 32%. Savings of at least 7.8% in generation costs and reductions in wind curtailment of 50% were identified when the most influential SOCs were relaxed. The results also illustrate the need to relax local SOCs together with the system-wide nonsynchronous penetration limit SOC, as savings from increasing the nonsynchronous limit beyond 70% were restricted without relaxation of local SOCs. The methodology and results allow for quantification of the costs of SOCs, allowing the optimal upgrade path for generation and transmission infrastructure to be determined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

info:eu-repo/semantics/nonPublished