949 resultados para Occlusion Culling
Resumo:
BACKGROUND AND PURPOSE: Basilar artery occlusion (BAO) is an infrequent form of acute stroke, which invariably leads to death or long-term disability if not recanalized. A traditional recanalization approach based on historical controls and pathophysiological consideration is local intra-arterial thrombolysis (IAT) in eligible patients. This necessitates diagnostic evaluation and treatment in stroke centers equipped with an interventional neuroradiological service on a 24-hour basis, but its superiority to the technically simple intravenous thrombolysis (IVT) remains unproven. METHODS: We analyzed systematically published case series of substantial size reporting the outcome of BAO after IAT or IVT. RESULTS: In 420 BAO patients treated with IVT (76) and IAT (344), death or dependency were equally common: 78% (59 of 76) and 76% (260 of 344), respectively (P=0.82). Recanalization was achieved more frequently with IAT (225 of 344; 65%) than with IVT (40 of 76; 53%; P=0.05), but survival rates after IVT (38 of 76; 50%) and IAT (154 of 344; 45%) were equal (P=0.48). A total of 24% of patients treated with IAT and 22% treated with IVT reached good outcomes (P=0.82). Without recanalization, the likelihood of good outcome was close to nil (2%). CONCLUSIONS: Recanalization occurs in more than half of BAO patients treated with IAT or IVT, and 45% to 55% of survivors regain functional independence. Although improved therapy forms for BAO are necessary, hospitals not equipped for IAT may set up IVT protocols. The effect of IVT is probably not much different from the effect of IAT. IVT represents probably the best treatment that can be offered to victims of acute BAO in such hospitals.
Resumo:
BACKGROUND: Physiological data obtained with the pulmonary artery catheter (PAC) are susceptible to errors in measurement and interpretation. Little attention has been paid to the relevance of errors in hemodynamic measurements performed in the intensive care unit (ICU). The aim of this study was to assess the errors related to the technical aspects (zeroing and reference level) and actual measurement (curve interpretation) of the pulmonary artery occlusion pressure (PAOP). METHODS: Forty-seven participants in a special ICU training program and 22 ICU nurses were tested without pre-announcement. All participants had previously been exposed to the clinical use of the method. The first task was to set up a pressure measurement system for PAC (zeroing and reference level) and the second to measure the PAOP. RESULTS: The median difference from the reference mid-axillary zero level was - 3 cm (-8 to + 9 cm) for physicians and -1 cm (-5 to + 1 cm) for nurses. The median difference from the reference PAOP was 0 mmHg (-3 to 5 mmHg) for physicians and 1 mmHg (-1 to 15 mmHg) for nurses. When PAOP values were adjusted for the differences from the reference transducer level, the median differences from the reference PAOP values were 2 mmHg (-6 to 9 mmHg) for physicians and 2 mmHg (-6 to 16 mmHg) for nurses. CONCLUSIONS: Measurement of the PAOP is susceptible to substantial error as a result of practical mistakes. Comparison of results between ICUs or practitioners is therefore not possible.
Resumo:
The rehabilitation of a patient with advanced tooth wear by means of Procera ZrO2 ceramic crowns is described. A healthy, 60 year old patient complained about front teeth esthetics and impaired function due to reduced tooth height. He was aware of bruxism and wished full mouth rehabilitation. The clinical examination showed that tooth wear was generalized, but most teeth could be maintained in both jaws. A staged procedure was planned, starting with a splint therapy and a provisional fixed prosthesis to reestablish correct vertical dimension of occlusion (VDO) and stable occlusal contacts. The new ZrO2 material with the Procera technique was chosen to restore all teeth in both jaws, except the mandible front teeth. In the second treatment phase, crown lengthening of the maxillary front teeth was performed and one implant placed to replace a maxillary premolar. After final tooth preparation, impression taking and bite registration the ZrO2 crown-copings were scanned, processed and completed by veneering. A flat occlusal scheme with stable front teeth guidance was established. The advantage of the presented treatment is the esthetic result in combination with a material of high mechanical and biological quality.
Resumo:
PURPOSE: To evaluate the acute and midterm effectiveness of a novel vascular occlusion device for embolization of the internal iliac artery (IIA) before endovascular repair of aortoiliac aneurysms. MATERIALS AND METHODS: Between March 2005 and April 2006, nine men (mean age, 75 years +/- 5; range, 66-83 y) with aortoiliac aneurysms underwent bifurcated endovascular stent-graft procedures. All these patients were referred specifically for embolization. Pre- and perioperatively, eight patients underwent unilateral embolization and one underwent bilateral embolization of the IIA to prevent type II endoleak. Via a contralateral femoral approach with a 6-F or 8-F sheath, the embolization procedure was performed with an Amplatzer Vascular Plug, a self-expandable cylindrical device consisting of a nitinol-based wire mesh. Technical success, clinical outcome, and complications were evaluated. Follow-up at 3, 6, and 12 months was performed with clinical and radiologic examinations. RESULTS: IIA embolization was technically successful in all cases and no procedure-related complications occurred. Imaging at discharge and at 3-, 6-, or 12-month follow-up was accomplished in all nine patients. Control computed tomography and magnetic resonance angiography did not reveal retrograde perfusion of the aneurysmal sac, ie, type II endoleak. Three of nine patients (33.3%) reported symptoms of buttock claudication that did not resolve completely. Clinical symptoms such as bowel ischemia or sexual dysfunction were not observed. CONCLUSIONS: The midterm results of this study suggest that preoperative IIA embolization with a nitinol vascular occlusion plug during endovascular treatment of aortoiliac aneurysms is safe and effective.
Resumo:
AIMS: We investigated whether myeloid-related protein 8/14 complex (MRP8/14) expressed by infiltrating monocytes and granulocytes may represent a mediator and early biomarker of acute coronary syndromes (ACS). METHODS AND RESULTS: Immunohistochemistry of coronary thrombi was done in 41 ACS patients. Subsequently, levels of MRP8/14 were assessed systemically in 75 patients with ACS and culprit lesions, with stable coronary artery disease (CAD), or with normal coronary arteries. In a subset of patients, MRP8/14 was measured systemically and at the site of coronary occlusion. Macrophages and granulocytes, but not platelets stained positive for MRP8/14 in 76% of 41 thrombi patients. In ACS, local MRP8/14 levels [22.0 (16.2-41.5) mg/L] were increased when compared with systemic levels [13.4 (8.1-14.7) mg/L, P = 0.03]. Systemic levels of MRP8/14 were markedly elevated [15.1 (12.1-21.8) mg/L, P = 0.001] in ACS when compared with stable CAD [4.6 (3.5-7.1) mg/L] or normals [4.8 (4.0-6.3) mg/L]. Using a cut-off level of 8 mg/L, MRP8/14 but not myoglobin or troponin, identified ACS presenting within 3 h from symptom onset. CONCLUSION: In ACS, MRP8/14 is markedly expressed at the site of coronary occlusion by invading phagocytes. The occurrence of elevated MRP8/14 in the systemic circulation prior to markers of myocardial necrosis makes it a prime candidate for the detection of unstable plaques and management of ACS.
Resumo:
BACKGROUND AND PURPOSE: Recent studies have reported sex differences in recanalization and outcome after intravenous thrombolysis (IVT) in acute ischemic stroke. METHODS: We analyzed sex differences in outcome in consecutive patients with middle cerebral artery (MCA) M1 or M2 and internal carotid artery (ICA) occlusion treated with intra-arterial thrombolysis (IAT). Recanalization immediately after thrombolysis and outcome after 3 months were assessed. RESULTS: Two hundred five patients (111 men) with MCA and 43 (22 men) with ICA occlusion were identified. Baseline variables did not differ between the sexes except for a higher prevalence of smokers among men in the MCA group (31% vs 12%; P=0.001). Partial or complete recanalization (TIMI flow 2 or 3) of the MCA was observed in 71 (75%) women and 80 (72%) men (P=0.488). In the ICA group, 14 (67%) women and 11 men (50%) showed TIMI 2 or 3 recanalization (P=0.425). Favorable outcome (modified Rankin Scale score 0 to 2) was seen in 57 women (61%) and 63 men (57%) with MCA occlusion (P=0.512) and in 6 women (28%) and 4 men (18%) with ICA occlusion (P=0.656). After multiple-regression analyses, there was still no association between sex and outcome (P=0.763 for MCA and P=0.813 for ICA occlusion) or recanalization (P=0.488 for MCA and P=0.104 for ICA occlusion). CONCLUSIONS: There was no association between sex and recanalization or outcome after IAT. These findings are in contrast to previous studies reporting better recanalization and outcome after IVT in women and might have implications in the selection of patients for IAT or IVT.
Resumo:
We present a case of combined central retinal vein and cilioretinal artery occlusion which, due to the absence of the temporal branch retinal artery, was initially misdiagnosed as a combined central retinal vein occlusion and temporal branch retinal artery occlusion. Given that - in contrast to cases of combined central artery and central retinal vein occlusion - the prognosis for cilioretinal artery occlusion with central retinal vein occlusion is quite good, this case illustrates the importance of suspecting an unusual condition in the presence of a combined occlusion.
Resumo:
PURPOSE: The objective of this study was to investigate the feasibility, outcomes, and amount of small intestinal submucosa (SIS) material needed for embolization of jugular vein (JV) in a swine and sheep model. Our hypothesis was that SIS would cause vein occlusion. MATERIALS AND METHODS: The external JVs (EJV) in swine (n = 6) and JVs in sheep (n = 6) were occluded with SIS fan-folded compressed strips. After percutaneous puncture of the peripheral portion of the EJV or JV, a TIPS set was used to exit their lumen centrally through the skin. The SIS strips were delivered into the isolated venous segment with a pull-through technique via a 10-Fr sheath. Follow-up venograms were done immediately after placement and at the time of sacrifice at 1 or 3 months. Gross examinations focused on the EJV or JV and their surrounding structures. Specimens were evaluated by histology. RESULTS: SIS strip(s) placement was successful in all cases, with immediate vein occlusion seen in 23 of 24 veins (95.8%). All EJVs treated with two strips and all JVs treated with three or four strips remained closed on 1- and 3-month follow-up venograms. Two EJVs treated with one strip and one JV treated with two strips were partially patent on venograms at 1 and 3 months. There has been one skin inflammatory reaction. Necropsies revealed excluded EJV or JV segments with SIS incorporation into the vein wall. Histology demonstrated various stages of SIS remodeling with fibrocytes, fibroblasts, endothelial cells, capillaries, and inflammatory cells. CONCLUSION: We conclude that EJV and JV ablation with SIS strips using percutaneous exit catheterization is feasible and effective in animal models. Further exploration of SIS as vein ablation material is recommended.
Resumo:
BACKGROUND AND PURPOSE: Although mechanical thrombectomy (MT) has an encouragingly high recanalization rate in treating stroke, it is associated with severe complications of which the underlying factors have yet to be identified. Because MT is a mechanical approach, the mechanical properties of the thrombus might be crucial for its success. The present study assesses the effect of thrombus length on the in vivo effectiveness and complication rate of MT. MATERIALS AND METHODS: Angiography and embolization of 21 cranial vessels with radiopaque whole-blood thrombi 10, 20, and 40 mm in length (7 occlusions each) were performed in 7 swine. MT was carried out using a distal snarelike device (BCR Roadsaver) with proximal balloon occlusion. A total of 61 retrievals were attempted. RESULTS: In the group of 10-mm occlusions, 77.8% of the attempts achieved complete recanalisation. For longer occlusions, the success rates decreased significantly to 20% of attempts for 20-mm occlusions (odds ratio [OR], 14; 95% confidence interval [CI], 2.2-89.2) and 11.1% for 40-mm occlusions (OR, 28; 95% CI, 3.9-202.2; P < .005). The low success rates were largely due to complications associated with thrombus compaction during retrieval. Similarly, the rate of thromboembolic events increased from 0% in 10-mm occlusions to 14.8% in 40-mm occlusions. CONCLUSIONS: MT using a distal device proved to be a fast, effective, and safe procedure for recanalizing short (10-mm) occlusions in the animal model. However, occlusion length emerged as a crucial determinant for MT with a significant decrease in recanalization success per attempt and increased complication rates. These findings suggest limitations of MT in the clinical application.
Resumo:
BACKGROUND AND PURPOSE: For selected stroke patients, intra-arterial thrombolysis (IAT) has been shown to be an effective treatment option. However, knowledge of safety and efficacy of IAT in patients with acute stroke as a complication of arterial catheter interventions is limited. METHODS: We analyzed clinical radiological findings and functional outcomes in consecutive patients 3 months after treatment with IAT for peri-procedural strokes occurring during neuroendovascular or cardiac catheter interventions. To measure outcome, the modified Rankin scale score was used. RESULTS: Of a total of 432 patients treated with IAT, 12 (4 women and 8 men; mean age, 60 years) were treated because of an ischemic stroke after a neuro-endovascular procedure (n=6) or coronary angiography (n=6). The median baseline National Institutes of Health Stroke Scale score was 15. Recanalization was complete (thrombolysis in myocardial infarction grade 3) in 6, partial (thrombolysis in myocardial infarction 2) in 5, and minimal (thrombolysis in myocardial infarction 1) in 1. Nine patients (75%) had a favorable outcome (modified Rankin scale score, 0 to 2), and 3 had a poor outcome (modified Rankin scale score, 3 or 4). All patients with complete recanalization had a favorable outcome, whereas only 3 of 6 patients with partial or minimal recanalization (P=0.18) had a favorable outcome. Follow-up brain imaging was normal in 2 and showed new ischemic lesions in 10 patients. Two patients (17%) had a symptomatic intracerebral hemorrhage. CONCLUSIONS: In acute stroke attributable to arterial catheter interventions, IAT is feasible and has the potential to improve outcome in these patients. A high recanalization rate could be achieved.
Resumo:
INTRODUCTION: The use of vascular plug devices for the occlusion of high-flow lesions is a relatively new and successful procedure in peripheral and cardiopulmonary interventions. We report on the use and efficiency of the Amplatzer vascular plug in a small clinical series and discuss its potential for occlusion of large vessels and high-flow lesions in neurointerventions. METHODS: Between 2005 and 2007 four patients (mean age 38.5 years, range 16-62 years) were treated with the device, in three patients to achieve parent artery occlusion of the internal carotid artery, in one patient to occlude a high-flow arteriovenous fistula of the neck. The application, time to occlusion, and angiographic and clinical results and the follow-up were evaluated. RESULTS: Navigation, positioning and detachment of the device were satisfactory in all cases. No flow-related migration of the plug was seen. The cessation of flow was delayed by a mean of 10.5 min after deployment of the first device. In the procedures involving vessel sacrifice, two devices had to be deployed to achieve total occlusion. No patient experienced new neurological deficits; the 3-month follow-up revealed stable results. CONCLUSION: The Amplatzer vascular plug can be adapted for the treatment of high-flow lesions and parent artery occlusions in the head and neck. In this small series the use of the devices was uncomplicated and safe. The rigid and large delivery device and the delayed cessation of flow currently limit the device's use in neurointerventions.