774 resultados para Observers
Resumo:
PURPOSE: To assess the impact of axial traction during acquisition of direct magnetic resonance (MR) arthrography of the wrist with regard to joint space width and amount of contrast material between the opposing cartilage surfaces. MATERIALS AND METHODS: Fifteen consecutive patients (12 male, mean age 38.1 years) were included in this Institutional Review Board-approved prospective study. Three-compartment wrist MR arthrographies were performed between October and December 2009 on a 3 T unit using a fat-suppressed T1-weighted isotropic high-resolution volumetric interpolated breathhold examination (VIBE) sequence in the coronal plane, with and without axial traction (3 kg). Two radiologists measured radiocarpal (radioscaphoid, radiolunate) and midcarpal (lunocapitate, hamatolunate) joint space widths, with and without traction, and assessed the amount of contrast material between the opposing cartilage surfaces using a three-point scale: 0 = absence, 1 = partial, 2 = complete. RESULTS: With traction, joint space width increased significantly at the radioscaphoid (Delta = 0.78 mm, P < 0.01), radiolunate (Delta = 0.18 mm, P < 0.01), and lunocapitate (Delta = 0.45 mm, P < 0.01) spaces, and both observers detected significantly more contrast material between the cartilage surfaces. At the hamatolunate space, the differences in joint space width (Delta = 0.14 mm, P = 0.54) and amount of contrast material were not significant. CONCLUSION: Direct wrist MR arthrography with axial traction of 3 kg increases joint space width at the radiocarpal and lunocapitate spaces, and prompts better coverage of the articular cartilage by the contrast material. J. Magn. Reson. Imaging 2011;. (c) 2011 Wiley-Liss, Inc.
Resumo:
Bone-mounted robotic guidance for pedicle screw placement has been recently introduced, aiming at increasing accuracy. The aim of this prospective study was to compare this novel approach with the conventional fluoroscopy assisted freehand technique (not the two- or three-dimensional fluoroscopy-based navigation). Two groups were compared: 11 patients, constituting the robotical group, were instrumented with 64 pedicle screws; 23 other patients, constituting the fluoroscopic group, were also instrumented with 64 pedicle screws. Screw position was assessed by two independent observers on postoperative CT-scans using the Rampersaud A to D classification. No neurological complications were noted. Grade A (totally within pedicle margins) accounted for 79% of the screws in the robotically assisted and for 83% of the screws in the fluoroscopic group respectively (p = 0.8). Grade C and D screws, considered as misplacements, accounted for 4.7% of all robotically inserted screws and 7.8% of the fluoroscopically inserted screws (p = 0.71). The current study did not allow to state that robotically assisted screw placement supersedes the conventional fluoroscopy assisted technique, although the literature is more optimistic about the former.
Resumo:
An accurate sense of time contributes to functions ranging from the perception and anticipation of sensory events to the production of coordinated movements. However, accumulating evidence demonstrates that time perception is subject to strong illusory distortion. In two experiments, we investigated whether the subjective speed of temporal perception is dependent on our visual environment. By presenting human observers with speed-altered movies of a crowded street scene, we modulated performance on subsequent production of "20s" elapsed intervals. Our results indicate that one's visual environment significantly contributes to calibrating our sense of time, independently of any modulation of arousal. This plasticity generates an assay for the integrity of our sense of time and its rehabilitation in clinical pathologies.
Resumo:
This article presents a feasibility study with the objective of investigating the potential of multi-detector computed tomography (MDCT) to estimate the bone age and sex of deceased persons. To obtain virtual skeletons, the bodies of 22 deceased persons with known age at death were scanned by MDCT using a special protocol that consisted of high-resolution imaging of the skull, shoulder girdle (including the upper half of the humeri), the symphysis pubis and the upper halves of the femora. Bone and soft-tissue reconstructions were performed in two and three dimensions. The resulting data were investigated by three anthropologists with different professional experience. Sex was determined by investigating three-dimensional models of the skull and pelvis. As a basic orientation for the age estimation, the complex method according to Nemeskéri and co-workers was applied. The final estimation was effected using additional parameters like the state of dentition, degeneration of the spine, etc., which where chosen individually by the three observers according to their experience. The results of the study show that the estimation of sex and age is possible by the use of MDCT. Virtual skeletons present an ideal collection for anthropological studies, because they are obtained in a non-invasive way and can be investigated ad infinitum.
Resumo:
Purpose: Recently morphometric measurements of the ascending aorta have been done with ECG-gated MDCT to help the development of future endovascular therapies (TCT) [1]. However, the variability of these measurements remains unknown. It will be interesting to know the impact of CAD (computer aided diagnosis) with automated segmentation of the vessel and automatic measurements of diameter on the management of ascending aorta aneurysms. Methods and Materials: Thirty patients referred for ECG-gated CT thoracic angiography (64-row CT scanner) were evaluated. Measurements of the maximum and minimum ascending aorta diameters were obtained automatically with a commercially available CAD and semi-manually by two observers separately. The CAD algorithms segment the iv-enhanced lumen of the ascending aorta into perpendicular planes along the centreline. The CAD then determines the largest and the smallest diameters. Both observers repeated the automatic measurements and the semimanual measurements during a different session at least one month after the first measurements. The Bland and Altman method was used to study the inter/intraobserver variability. A Wilcoxon signed-rank test was also used to analyse differences between observers. Results: Interobserver variability for semi-manual measurements between the first and second observers was between 1.2 to 1.0 mm for maximal and minimal diameter, respectively. Intraobserver variability of each observer ranged from 0.8 to 1.2 mm, the lowest variability being produced by the more experienced observer. CAD variability could be as low as 0.3 mm, showing that it can perform better than human observers. However, when used in nonoptimal conditions (streak artefacts from contrast in the superior vena cava or weak lumen enhancement), CAD has a variability that can be as high as 0.9 mm, reaching variability of semi-manual measurements. Furthermore, there were significant differences between both observers for maximal and minimal diameter measurements (p<0.001). There was also a significant difference between the first observer and CAD for maximal diameter measurements with the former underestimating the diameter compared to the latter (p<0.001). As for minimal diameters, they were higher when measured by the second observer than when measured by CAD (p<0.001). Neither the difference of mean minimal diameter between the first observer and CAD nor the difference of mean maximal diameter between the second observer and CAD was significant (p=0.20 and 0.06, respectively). Conclusion: CAD algorithms can lessen the variability of diameter measurements in the follow-up of ascending aorta aneurysms. Nevertheless, in non-optimal conditions, it may be necessary to correct manually the measurements. Improvements of the algorithms will help to avoid such a situation.
Resumo:
What allows an armed group in a civil war to prevent desertion? This paper addresses this question with a focus on control in the rearguard. Most past studies focus on motivations for desertion. They explain desertion in terms of where soldiers stand in relation to the macro themes of the war, or in terms of an inability to provide positive incentives to overcome the collective action problem. However, since individuals decide whether and how to participate in civil wars for multiple reasons, responding to a variety of local conditions in an environment of threat and violence, a focus only on macro-level motivations is incomplete. The opportunities side of the ledger deserves more attention. I therefore turn my attention to how control by an armed group eliminates soldiers’ opportunities to desert. In particular, I consider the control that an armed group maintains over soldiers’ hometowns, treating geographic terrain as an important exogenous indicator of the ease of control. Rough terrain at home affords soldiers and their families and friends advantages in ease of hiding, the difficulty of using force, and local knowledge. Based on an original dataset of soldiers from Santander Province in the Spanish Civil War, gathered from archival sources, I find statistical evidence that the rougher the terrain in a soldier’s home municipality, the more likely he is to desert. I find complementary qualitative evidence indicating that soldiers from rough-terrain communities took active advantage of their greater opportunities for evasion. This finding has important implications for the way observers interpret different soldiers’ decisions to desert or remain fighting, for the prospect that structural factors may shape the cohesion of armed groups, and for the possibility that local knowledge may be a double-edged sword, making soldiers simultaneously good at fighting and good at deserting.
Resumo:
RATIONALE AND OBJECTIVES: To determine optimum spatial resolution when imaging peripheral arteries with magnetic resonance angiography (MRA). MATERIALS AND METHODS: Eight vessel diameters ranging from 1.0 to 8.0 mm were simulated in a vascular phantom. A total of 40 three-dimensional flash MRA sequences were acquired with incremental variations of fields of view, matrix size, and slice thickness. The accurately known eight diameters were combined pairwise to generate 22 "exact" degrees of stenosis ranging from 42% to 87%. Then, the diameters were measured in the MRA images by three independent observers and with quantitative angiography (QA) software and used to compute the degrees of stenosis corresponding to the 22 "exact" ones. The accuracy and reproducibility of vessel diameter measurements and stenosis calculations were assessed for vessel size ranging from 6 to 8 mm (iliac artery), 4 to 5 mm (femoro-popliteal arteries), and 1 to 3 mm (infrapopliteal arteries). Maximum pixel dimension and slice thickness to obtain a mean error in stenosis evaluation of less than 10% were determined by linear regression analysis. RESULTS: Mean errors on stenosis quantification were 8.8% +/- 6.3% for 6- to 8-mm vessels, 15.5% +/- 8.2% for 4- to 5-mm vessels, and 18.9% +/- 7.5% for 1- to 3-mm vessels. Mean errors on stenosis calculation were 12.3% +/- 8.2% for observers and 11.4% +/- 15.1% for QA software (P = .0342). To evaluate stenosis with a mean error of less than 10%, maximum pixel surface, the pixel size in the phase direction, and the slice thickness should be less than 1.56 mm2, 1.34 mm, 1.70 mm, respectively (voxel size 2.65 mm3) for 6- to 8-mm vessels; 1.31 mm2, 1.10 mm, 1.34 mm (voxel size 1.76 mm3), for 4- to 5-mm vessels; and 1.17 mm2, 0.90 mm, 0.9 mm (voxel size 1.05 mm3) for 1- to 3-mm vessels. CONCLUSION: Higher spatial resolution than currently used should be selected for imaging peripheral vessels.
Resumo:
This paper characterizes and evaluates the potential of three commercial CT iterative reconstruction methods (ASIR?, VEO? and iDose(4 ()?())) for dose reduction and image quality improvement. We measured CT number accuracy, standard deviation (SD), noise power spectrum (NPS) and modulation transfer function (MTF) metrics on Catphan phantom images while five human observers performed four-alternative forced-choice (4AFC) experiments to assess the detectability of low- and high-contrast objects embedded in two pediatric phantoms. Results show that 40% and 100% ASIR as well as iDose(4) levels 3 and 6 do not affect CT number and strongly decrease image noise with relative SD constant in a large range of dose. However, while ASIR produces a shift of the NPS curve apex, less change is observed with iDose(4) with respect to FBP methods. With second-generation iterative reconstruction VEO, physical metrics are even further improved: SD decreased to 70.4% at 0.5 mGy and spatial resolution improved to 37% (MTF(50%)). 4AFC experiments show that few improvements in detection task performance are obtained with ASIR and iDose(4), whereas VEO makes excellent detections possible even at an ultra-low-dose (0.3 mGy), leading to a potential dose reduction of a factor 3 to 7 (67%-86%). In spite of its longer reconstruction time and the fact that clinical studies are still required to complete these results, VEO clearly confirms the tremendous potential of iterative reconstructions for dose reduction in CT and appears to be an important tool for patient follow-up, especially for pediatric patients where cumulative lifetime dose still remains high.
Resumo:
We performed a pilot study to compare vertebral fracture assessments (VFA) and lateral X-rays in terms of inter- and intraobserver reliability and degree of correlation for the detection of syndesmophytes in ankylosing spondylitis (AS). We recruited 19 patients with AS and recent lumbar or cervical lateral X-rays with at least one syndesmophyte. Each patient underwent dual-energy X-ray absorptiometry with measurement of bone mineral density and dorso-lumbar VFA. Intra- and interreader reliability for VFA and X-rays were measured using 2 independent, blinded observers and Cohen's kappa values. An adapted modified Stoke Ankylosing Spondylitis Spinal Score (amSASSS) was generated with each method, and these 2 values correlated. For X-rays, intraobserver and interobserver agreement were 94.3% (κ = 0.83) and 98.6% (κ = 0.96), respectively; for VFA, corresponding values were 92.8% (κ = 0.79) and 93.8% (κ = 0.82). Overall agreement between the 2 techniques was 88.6% (κ = 0.72). The Pearson correlation coefficient for the 2 methods was 0.95 for the modified Stoke Ankylosing Spondylitis Spinal Score . Per dual-energy X-ray absorptiometry-generated bone mineral density, >50% of patients were osteopenic and 10% osteoporotic. In terms of reproducibility and correlation with X-rays, performing a VFA appears to be a candidate for assessing radiographic damage in AS, thought further research is necessary to justify this indication.
Resumo:
Background Despite use in clinical practice and trials of thrombolysis, a non-contrast CT is not sensitive for identifying penumbral tissue in acute stroke. This study evaluated how it compares with physiological imaging using CT perfusion.Methods 40 imaging datasets with non-contrast CT (NCCT) and perfusion CT (CTP) were retrospectively identified. 2 sets of observers (n¼6) and a neuroradiologist made a blind evaluation of the images. Inter-observer agreement was calculated for identifying ischaemic change on NCCT, and abnormalities on cerebral blood flow, time to peak and cerebral blood volume maps. A prospective cohort of 73 patients with anterior circulation cortical strokes were thrombolysed based on qualitative assessment of penumbral tissue on CTP within 3 h of stroke onset. Functional outcome was assessed at 3 months.Results Inter-rater agreement was moderate (k¼0.54) for early ischaemic change on NCCT. Perfusion maps improved this to substantial for deficit in cerebral blood volume (k¼0.67) and almost perfect for time to peak and cerebral blood flow (both k¼0.87). In the prospective arm, 58.9% of patients with cortical strokes were thrombolysed. There was no significant difference in attainment of complete recovery (p¼0.184) between the thrombolysed and nonthrombolysed group.Conclusions We demonstrate how perfusion CT aids clinical decision- making in acute stroke. Good functional outcomes from thrombolysis can be safely achieved using this physiologically informed approach.
Resumo:
The current study conceptualized observer reactions to uncivil behavior towards women as an ethical behavior and examined three factors (target reaction, actor motive, and actor-target relationship) that influence these reactions. Two vignette studies with women and men undergraduate and graduate students in western Switzerland were conducted. Study 1 (N=148) was a written vignette study that assessed how the reaction of female targets to incivility and the motives of actors influenced observer reactions. Results showed that a female target's reaction influenced observers' evaluations of the harm caused by an uncivil incident, and that an actor's motive affected observers' assessments of the necessity to intervene. Study 2 (N=81) was a video vignette study that assessed the effects of the reactions by female targets to incivility and the relationship between the target and the actor on observer reactions.We found that female targets' reactions influenced observers' evaluations of harm and the perceived necessity to intervene. Furthermore, the effect of a female target's reaction on observers' evaluations of harm was moderated by the relationship between the actor and the target: a female target who laughed at the uncivil behavior was perceived as less harmed, when she and the actor had a personal relationship than when they had a professional relationship. When the female target reacted hurt or neutrally, actor-target relationship did not affect observers' evaluations of harm. We conclude by discussing the implications of our findings for theory and practice.
Resumo:
Introduction: Clinical symptoms and degree of spinal stenosis based on cross sectional dural sac area correlate only weakly in lumbar spinal stenosis (LSS) patients. We conceived a four grade classification system (A, B, C & D) based on the morphology of the dural sac and its contents as seen on T2 axial MRI images. The categories take into account the rootlet/CSF ratio. We applied this grading to three patient groups: LSS scheduled for surgery; LSS following conservative treatment and patients with low back pain (LBP) without leg pain. Materials/Methods: A total of 346 T2 axial MRI images taken from LSS and LBP patients were included in this retroperspective study. 37 patients had decompressive surgery (132 MRI images), 31 conservative treatment (116 MRI images) and 27 patients had unspecific LBP (98 MRI images). Dural sac cross-sectional surface area and morphological grading of the canal were measured digitally both at disc and pedicle level. Intra- and inter-observer reliability were assessed (weighted Cohen's kappa statistics) from 50 MRI images taken from the surgery group. Results: At the most severe disc level, grade A (mild stenosis) was found in 3% of MRI images of the surgical group as opposed to 51% in the conservatively treated group and 85% in the LBP group. Grade B occurred in 8% of the surgical, 20% of the conservative and was negligible in LBP group (below 1%). Grade C and D (severe stenosis) was found in 89% of the surgical group, as opposed to 30% in conservative group and 11% in LBP group. The grades of all groups were comparable at the pedicle levels, exhibiting in 94% a grade A with a maximum at the A1 grade. Pedicle and disc level cross-sectional area were smallest in the surgery group and smaller in the conservative group as compared to the LBP group at the levels L2, L3 and L4. According to cross-sectional area measurements patients from the surgery group seems to have smaller vertebral canal although this was not related to smaller stature. Validation of grading: Average intra-and inter observer kappas were 0.76 and 0.69 respectively, for physicians working in the study originating institution. Combining all observers the kappa values were 0.57 +/- 0.19. and 0.44 +/- 0.19 respectively. Dural sac cross-sectional area measurements showed no statistically significant differences between observers. Conclusion: Since no specific measurement tools are needed the grading suits everyday clinical practice and favours communication of degree of stenosis between practising physicians. In our institution Grade A stenosis was less likely to require surgical treatment. This grading can therefore be an aid in surgical patient selection in teaching units.
Resumo:
Introduction: Coronary magnetic resonance angiography (MRA) is a medical imaging technique that involves collecting data from consecutive heartbeats, always at the same time in the cardiac cycle, in order to minimize heart motion artifacts. This technique relies on the assumption that coronary arteries always follow the same trajectory from heartbeat to heartbeat. Until now, choosing the acquisition window in the cardiac cycle was based exclusively on the position of minimal coronary motion. The goal of this study was to test the hypothesis that there are time intervals during the cardiac cycle when coronary beat-to-beat repositioning is optimal. The repositioning uncertainty values in these time intervals were then compared with the intervals of low coronary motion in order to propose an optimal acquisition window for coronary MRA. Methods: Cine breath-hold x-ray angiograms with synchronous ECG were collected from 11 patients who underwent elective routine diagnostic coronarography. Twenty-three bifurcations of the left coronary artery were selected as markers to evaluate repositioning uncertainty and velocity during cardiac cycle. Each bifurcation was tracked by two observers, with the help of a user-assisted algorithm implemented in Matlab (The Mathworks, Natick, MA, USA) that compared the trajectories of the markers coming from consecutive heartbeats and computed the coronary repositioning uncertainty with steps of 50ms until 650ms after the R-wave. Repositioning uncertainty was defined as the diameter of the smallest circle encompassing the points to be compared at the same time after the R-wave. Student's t-tests with a false discovery rate (FDR, q=0.1) correction for multiple comparison were applied to see whether coronary repositioning and velocity vary statistically during cardiac cycle. Bland-Altman plots and linear regression were used to assess intra- and inter-observer agreement. Results: The analysis of left coronary artery beat-to-beat repositioning uncertainty shows a tendency to have better repositioning in mid systole (less than 0.84±0.58mm) and mid diastole (less than 0.89±0.6mm) than in the rest of the cardiac cycle (highest value at 50ms=1.35±0.64mm). According to Student's t-tests with FDR correction for multiple comparison (q=0.1), two intervals, in mid systole (150-200ms) and mid diastole (550-600ms), provide statistically better repositioning in comparison with the early systole and the early diastole. Coronary velocity analysis reveals that left coronary artery moves more slowly in end systole (14.35±11.35mm/s at 225ms) and mid diastole (11.78±11.62mm/s at 625ms) than in the rest of the cardiac cycle (highest value at 25ms: 55.96±22.34mm/s). This was confirmed by Student's t-tests with FDR correction for multiple comparison (q=0.1, FDR-corrected p-value=0.054): coronary velocity values at 225, 575 and 625ms are not much different between them but they are statistically inferior to all others. Bland-Altman plots and linear regression show that intra-observer agreement (y=0.97x+0.02 with R²=0.93 at 150ms) is better than inter-observer (y=0.8x+0.11 with R²=0.67 at 150ms). Discussion: The present study has demonstrated that there are two time intervals in the cardiac cycle, one in mid systole and one in mid diastole, where left coronary artery repositioning uncertainty reaches points of local minima. It has also been calculated that the velocity is the lowest in end systole and mid diastole. Since systole is less influenced by heart rate variability than diastole, it was finally proposed to test an acquisition window between 150 and 200ms after the R-wave.
Resumo:
We validated the polymerase chain reaction (PCR) with a composite reference standard in 61 patients clinically suspected of having mucosal leishmaniasis, 36 of which were cases and 25 were non-cases according to this reference standard. Patient classification and test application were carried out independently by two blind observers. One pair of primers was used to amplify a fragment of 120 bp in the conserved region of kDNA and another pair was used to amplify the internal transcript spacers (ITS) rDNA. PCR showed 68.6% (95% CI 59.2-72.6) sensitivity and 92% (95% CI 78.9-97.7) specificity; positive likelihood ratio: 8.6 (95% CI 2.8-31.3) and negative likelihood ratio: 0.3 (95% CI 0.3-0.5), when kDNA molecular target was amplified. The test performed better on sensitivity using this target compared to the ITS rDNA molecular target which showed 40% (95% CI 31.5-42.3) sensitivity and 96% (95% CI 84.1-99.3) specificity; positive likelihood ratio: 10 (95% CI 2.0-58.8) and negative likelihood ratio: 0.6 (95% CI 0.6-0.8). The inter-observer agreement was excellent for both tests. Based upon results obtained and due to low performance of conventional methods for diagnosing mucosal leishmaniasis, we consider PCR with kDNA as molecular target is a useful diagnostic test and the ITS rDNA molecular target is useful when the aim is to identify species.
Resumo:
Aim: to find the Risk Assessment Scales (RAS) for pressure ulcers in children published in the literature. To determine which of them have been properly validated. Methods: a systematic review of the literature has been conducted searching in 14 Health Sciences databases. The inclusion criteria were: studies published between 1962 and 2009, with a prospective design, less than a 25 % lost to follow-up, and with data of validity, prognostic or reliability. No language restriction was applied. Methodological quality of the studies was assessed by the CASP guide. Results: seventeen studies were found. In these studies 11 RAS for children were identified. Most of them were developed for the critical care area, based on previous risk assessment scales for adult. There are only 3 scales with one validation study: NSRAS, Braden Q and Starkid Skin. Their sensibility and specificity figures are: Braden Q, sens = 88% and specif. 58%; NSRAS, 83% and 81%; and Starkid Skin, 17% and 98%. Although the NSRAS scale has good validity figures, the simple size of this study was too small, so these results need further validation. The Starkid scale has a sensibility too low. The Braden Q was the only scale with suitable validity and prognostic figures, though its inter-observers reliability has not been tested, so more research to confirm these results is needed. The assessment of pressure ulcers risk in children is recommended, although, with the available evidence, we can not recommend the use of any of these RAS over the others. More research about this topic is needed.